    "id": "opd_activity",
    "dept": "门诊",
    "name": "儿童活动室",
    "type": "activity",
    "priority": "P2",
    "summary": "儿童活动室审图重点包括空间独立与尺度、看护视线净距、门洞口净宽等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.2.6条第6款；《综合医院建设标准》第五条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/门诊/CAD/门诊平面_t3.dwg",
      "docs/materials/门诊/儿童活动室.png"
    ],
    "preview": "assets/img/previews/opd_activity.jpg",
    "rules": [
      "child",
      "infection",
      "accessible"
    ],
    "siteModel": "models/viewer.html?scene=opd-activity",
    "siteModelName": "3D交互信息模型（儿童活动室·新版）",
    "sceneInfo": {
      "thumb": "assets/img/scene-thumbs/opd-activity.jpg",
      "area": "4.20 × 5.60 m · 净高 3.0m（≈23.5㎡，按图 5600×4200）",
      "dims": {
        "def": [
          4.2,
          5.6,
          3
        ],
        "min": [
          3.6,
          4.8,
          2.8
        ],
        "sugg": [
          4.2,
          5.6,
          3
        ],
        "minLabel": "儿科最低",
        "suggLabel": "图则平面"
      },
      "stats": {
        "furn": 15,
        "markers": 9
      },
      "cost": "约 4.3–16.7 万元"
    },
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "空间独立与尺度",
        "requirement": "候诊区附近宜设置儿童活动区，功能划分应合理。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.2.6条第6款",
        "suggestion": "独立成区且使用面积≥12.0㎡。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "看护视线净距",
        "requirement": "建筑设计应充分考虑使用人群的生理与心理特点，注重环境改善。",
        "source": "《综合医院建设标准》第五条",
        "suggestion": "在活动区边缘规划家长专属靠背座椅（不使用移动长凳）。座椅与活动核心区之间留出≥1.5m的家长看护缓冲走道。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "门洞口净宽",
        "requirement": "门诊部公共用房的门洞口净宽不应小于0.90m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.2.4条第4款",
        "suggestion": "优化： 统一采用1200mm宽单扇平开大木门（配防夹手缓冲阻尼与双向自闭装置），严禁采用推拉门、弹簧门或狭窄的子母门，确保童车无障碍通行。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "高等级地面防滑",
        "requirement": "地面应选用防滑、易清洗的材料。",
        "source": "《综合医院建设标准》第三十九条第四款",
        "suggestion": "无缝同质透心防滑PVC地板或一体化防滑发泡软地垫，防滑等级严格执行≥R11，拒绝地砖分格网格。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "全圆弧防撞阳角",
        "requirement": "儿童可触及部位的阳角应做成圆弧。",
        "source": "《综合医院建设标准》第三十九条第七款",
        "suggestion": "室内所有固定构件、低位窗台、地台及玩具展示柜阳角，物理上必须做R≥20mm的圆弧或防撞橡胶全包覆。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "全立面阻燃软包",
        "requirement": "内墙墙体不应使用易裂、易燃、不耐碰撞的材料。",
        "source": "《综合医院建设标准》第三十九条第三款",
        "suggestion": "房间四周墙面1.2m（建议优化至1.5m）高度以下全部铺设B1级阻燃、柔和低饱和度色调防撞软包"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "装修材料性能",
        "requirement": "建筑内人员密集的场所，其内部装修材料的燃烧性能均应为A级（顶棚、墙面）和不低于B1级（地面）。",
        "source": "《建筑防火通用规范》GB 55037-2022 第6.5.6条",
        "suggestion": "图纸技术说明中明示：活动室顶棚、基层墙面均采用A级不燃材料，地面及防撞软包材料不低于B1级阻燃。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "独立机械排烟",
        "requirement": "建筑的疏散走道、人员密集的场所应依法设置防烟与排烟设施。",
        "source": "《建筑防火通用规范》GB 55037-2022 第8.2.1条",
        "suggestion": "活动室属于儿童密集公共场所，无自然通风条件时吊顶内必须配置独立机械排烟风管点位，排风量≥80m³/h。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "疏散门开启方向",
        "requirement": "民用建筑内各房间疏散门的开启方向：应向疏散方向开启。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.4条",
        "suggestion": "活动室平开门必须向外侧疏散走廊方向开启（顺疏散方向）。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "疏散净宽底线",
        "requirement": "疏散走道、疏散门的净宽度均不应小于1.1m。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.4条第3款",
        "suggestion": "确保活动室大门开启后，不得占用或减少外侧候诊走廊的通行有效净宽（单侧候诊净宽≥2.4m，双侧≥3.0m）。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "疏散路径畅通",
        "requirement": "建筑内的安全出口和疏散门应分散布置，严禁占用。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.1条",
        "suggestion": "室内最远点至安全出口直线距离≤15m。大门开启的1.4m扇形有效区域内属于绝对安全净空，严禁堆放任何移动玩具箱。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "专属手卫生点位",
        "requirement": "诊疗区域附近应设置手卫生设施。儿科区域卫生间应设置儿童专用洁具。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第6.2.5条；《综合医院建设标准》第三十九条第六款",
        "suggestion": "出入口及活动室内直通线上刚性配置双高度非接触式感应洗手池（儿童0.55m，成人0.80m），水嘴做防喷溅工艺深化。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "易消毒接触界面",
        "requirement": "医疗业务用房应符合医院感染预防与控制的基本原则，易于冲洗、消毒。",
        "source": "《儿童医院建设标准》建标174-2016 第三十四条",
        "suggestion": "固定玩具柜、墙面软包面层应选用耐高浓度医用消毒剂擦洗的环保无缝材质。中文简体粗体标签（如：玩具柜、感应洗手池）100%内置于线框内。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "隐藏式废弃物收集",
        "requirement": "废弃物的集中收集存放应封闭处理。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第4.2.1条",
        "suggestion": "室内角落规划嵌壁式隐藏废物收集箱，配置触控或感应掀盖，与儿童直接游戏路径物理隔离。"
      }
    ],
    "docFacts": [
      "空间独立与尺度：候诊区附近宜设置儿童活动区，功能划分应合理。",
      "看护视线净距：建筑设计应充分考虑使用人群的生理与心理特点，注重环境改善。",
      "门洞口净宽：门诊部公共用房的门洞口净宽不应小于0.90m。",
      "高等级地面防滑：地面应选用防滑、易清洗的材料。",
      "全圆弧防撞阳角：儿童可触及部位的阳角应做成圆弧。",
      "全立面阻燃软包：内墙墙体不应使用易裂、易燃、不耐碰撞的材料。"
    ],
    "docReview": [
      "空间模数与净空 / 空间独立与尺度：独立成区且使用面积≥12.0㎡。",
      "空间模数与净空 / 看护视线净距：在活动区边缘规划家长专属靠背座椅（不使用移动长凳）。座椅与活动核心区之间留出≥1.5m的家长看护缓冲走道。",
      "空间模数与净空 / 门洞口净宽：优化： 统一采用1200mm宽单扇平开大木门（配防夹手缓冲阻尼与双向自闭装置），严禁采用推拉门、弹簧门或狭窄的子母门，确保童车无障碍通行。",
      "室内装修与防护 / 高等级地面防滑：无缝同质透心防滑PVC地板或一体化防滑发泡软地垫，防滑等级严格执行≥R11，拒绝地砖分格网格。",
      "室内装修与防护 / 全圆弧防撞阳角：室内所有固定构件、低位窗台、地台及玩具展示柜阳角，物理上必须做R≥20mm的圆弧或防撞橡胶全包覆。",
      "室内装修与防护 / 全立面阻燃软包：房间四周墙面1.2m（建议优化至1.5m）高度以下全部铺设B1级阻燃、柔和低饱和度色调防撞软包",
      "建筑防火与疏散 / 装修材料性能：图纸技术说明中明示：活动室顶棚、基层墙面均采用A级不燃材料，地面及防撞软包材料不低于B1级阻燃。",
      "建筑防火与疏散 / 独立机械排烟：活动室属于儿童密集公共场所，无自然通风条件时吊顶内必须配置独立机械排烟风管点位，排风量≥80m³/h。"
    ],
    "docBrief": "儿童活动室审图重点包括空间独立与尺度、看护视线净距、门洞口净宽等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.2.6条第6款；《综合医院建设标准》第五条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 3,
      "priority": "P2",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 5,
      "finalStatus": "部分完成",
      "finalRequirement": "沙发和游戏构件避开门扇两侧；补儿童游戏、洗手支持及人物使用位。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "opd_assessment",
    "dept": "门诊",
    "name": "儿童智力筛查室",
    "type": "clinic",
    "priority": "P3",
    "summary": "儿童智力筛查室审图重点包括空间分隔与面积、视听干扰防护、门洞口通行净宽等内容；依据《综合医院建筑设计标准》GB 51039-2014 第3.2.6条；《综合医院建设标准》第三十九条第八款；《综合医院建设标准》第五条、第三十九条第七款复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/门诊/轴测/智力筛查室.png",
      "docs/materials/2026.7.6/门诊/CAD/门诊平面_t3.dwg"
    ],
    "preview": "assets/img/previews/opd_assessment.jpg",
    "rules": [
      "privacy",
      "child",
      "area"
    ],
    "siteModel": "models/viewer.html?scene=opd-assessment",
    "siteModelName": "3D交互信息模型（儿童智力筛查室·新版）",
    "sceneInfo": {
      "thumb": "assets/img/scene-thumbs/opd-assessment.jpg",
      "area": "2.80 × 4.60 m · 净高 2.9m（≈12.9㎡，按图 4600×2800）",
      "dims": {
        "def": [
          2.8,
          4.6,
          2.9
        ],
        "min": [
          2.6,
          4.2,
          2.7
        ],
        "sugg": [
          2.8,
          4.6,
          2.9
        ],
        "minLabel": "评估室最低",
        "suggLabel": "图则平面"
      },
      "stats": {
        "furn": 10,
        "markers": 9
      },
      "cost": "约 3.4–12.1 万元"
    },
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "空间分隔与面积",
        "requirement": "各个功能用房空间尺寸应符合医疗操作规范。检查、治疗用房应满足使用人群的隐私要求。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第3.2.6条；《综合医院建设标准》第三十九条第八款",
        "suggestion": "基于模块化网格，整体净面积优化为≥15.0㎡（建议采用4200mm×4200mm模块）。图纸中须明确划定医生筛查评估区与家长陪护等候线。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "视听干扰防护",
        "requirement": "诊疗区域的门窗、家具和楼地面等应采取必要的安全保护措施。充分考虑使用人群的生理与心理特点。",
        "source": "《综合医院建设标准》第五条、第三十九条第七款",
        "suggestion": "测试桌椅应背对出入口，面向无窗素色内墙。全面取消图纸上的透视投影、地面面砖分格线及阴影，防止线条干扰视线。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "门洞口通行净宽",
        "requirement": "门诊部用房的门洞口净宽不应小于0.90m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.2.4条第4款",
        "suggestion": "统一采用1000mm宽单扇平开医疗隔音门（配置防夹手圆角胶条及高阶阻尼自闭器），严禁采用子母门或双开门，确保声学气密性。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "非接触手卫生",
        "requirement": "诊室、治疗室等房间的洗手盆应采用非手动开关，并应采取防止污水外溅的措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第6.2.5条第4款",
        "suggestion": "洗手盆必须刚性配置于诊室入口死角处，避免其洗手水流声在测试过程中干扰患儿。水嘴采用非接触感应式。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "界面防磕碰阳角",
        "requirement": "儿童诊疗区域的门窗、家具和楼地面等应采取必要的安全保护措施。",
        "source": "《综合医院建设标准》第三十九条第七款",
        "suggestion": "室内所有固定筛查柜、测试桌及墙体阳角物理上做R≥20mm的圆弧或全包覆软包，彻底消除棱角。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "低饱和防撞软包",
        "requirement": "内墙墙体不应使用易裂、易燃、不耐碰撞的材料。",
        "source": "《综合医院建设标准》第三十九条第三款",
        "suggestion": "墙面1.2m以下设置B1级阻燃、低饱和度色调（如素白、浅米黄）防撞软包，严禁使用高饱和度多色卡通拼图，以防干扰测试。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "疏散门开启方向",
        "requirement": "民用建筑内各房间疏散门的开启方向：应向疏散方向开启。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.4条",
        "suggestion": "平面图纸中智力筛查室平开门必须向疏散走廊方向开启（顺疏散方向）。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "疏散路径畅通",
        "requirement": "建筑内的安全出口和疏散门应分散布置，严禁占用。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.1条",
        "suggestion": "房间内最远点至疏散门直线距离≤15m。门扇后方1.4m安全疏散半径内严禁堆放移动教具、儿童拼图地垫或移动车。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "装修材料性能",
        "requirement": "内部装修材料的燃烧性能均应为A级（顶棚、墙面）和不低于B1级（地面）。",
        "source": "《建筑防火通用规范》GB 55037-2022 第6.5.6条",
        "suggestion": "图纸技术说明中明示：顶棚、墙面均采用A级不燃吸音材料，地面及防撞软包面层不低于B1级阻燃。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "空间分隔与面积",
        "requirement": "各个功能用房空间尺寸应符合医疗操作规范。检查、治疗用房应满足使用人群的隐私要求。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第3.2.6条；《综合医院建设标准》第三十九条第八款",
        "suggestion": "基于模块化网格，整体净面积优化为≥15.0㎡（建议采用4200mm×4200mm模块）。图纸中须明确划定医生筛查评估区与家长陪护等候线。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "高频接触耐消毒",
        "requirement": "阳角及高频接触面应易清洁消毒。台面均应采用易洁净、耐腐蚀、可冲洗的面层。",
        "source": "《综合医院建设标准》第三十九条第六款、第五款",
        "suggestion": "筛查测试桌采用抗菌无缝实体面材（圆弧边）。2D图面上所有中文简体粗体标签（如：筛查桌、测听仪）100%内置于线框内。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "隐藏式医疗废物",
        "requirement": "医疗业务用房应符合医院感染预防与控制的基本原则。",
        "source": "《儿童医院建设标准》建标174-2016 第三十四条",
        "suggestion": "医疗废物与生活垃圾容器采用嵌壁隐蔽式设计，必须完全收纳在固定柜体内部，严禁暴露在儿童视线内而分散其注意力。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "环境隔声与降噪",
        "requirement": "建筑内各种设备用房、其产生的噪声与振动不应传至有安静要求的区域……医疗用房的隔声、隔振设计应达标。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.12条、第10.4.1条",
        "suggestion": "筛查室四周墙体隔声量刚性执行强制性要求：RW＋Ctr≥45dB，室内允许噪声级不应大于35dB(A)。天花与墙面设高效吸音板。"
      }
    ],
    "docFacts": [
      "空间分隔与面积：各个功能用房空间尺寸应符合医疗操作规范。检查、治疗用房应满足使用人群的隐私要求。",
      "视听干扰防护：诊疗区域的门窗、家具和楼地面等应采取必要的安全保护措施。充分考虑使用人群的生理与心理特点。",
      "门洞口通行净宽：门诊部用房的门洞口净宽不应小于0.90m。",
      "非接触手卫生：诊室、治疗室等房间的洗手盆应采用非手动开关，并应采取防止污水外溅的措施。",
      "界面防磕碰阳角：儿童诊疗区域的门窗、家具和楼地面等应采取必要的安全保护措施。",
      "低饱和防撞软包：内墙墙体不应使用易裂、易燃、不耐碰撞的材料。"
    ],
    "docReview": [
      "空间模数与净空 / 空间分隔与面积：基于模块化网格，整体净面积优化为≥15.0㎡（建议采用4200mm×4200mm模块）。图纸中须明确划定医生筛查评估区与家长陪护等候线。",
      "空间模数与净空 / 视听干扰防护：测试桌椅应背对出入口，面向无窗素色内墙。全面取消图纸上的透视投影、地面面砖分格线及阴影，防止线条干扰视线。",
      "空间模数与净空 / 门洞口通行净宽：统一采用1000mm宽单扇平开医疗隔音门（配置防夹手圆角胶条及高阶阻尼自闭器），严禁采用子母门或双开门，确保声学气密性。",
      "空间模数与净空 / 非接触手卫生：洗手盆必须刚性配置于诊室入口死角处，避免其洗手水流声在测试过程中干扰患儿。水嘴采用非接触感应式。",
      "室内装修与防护 / 界面防磕碰阳角：室内所有固定筛查柜、测试桌及墙体阳角物理上做R≥20mm的圆弧或全包覆软包，彻底消除棱角。",
      "室内装修与防护 / 低饱和防撞软包：墙面1.2m以下设置B1级阻燃、低饱和度色调（如素白、浅米黄）防撞软包，严禁使用高饱和度多色卡通拼图，以防干扰测试。",
      "建筑防火与疏散 / 疏散门开启方向：平面图纸中智力筛查室平开门必须向疏散走廊方向开启（顺疏散方向）。",
      "建筑防火与疏散 / 疏散路径畅通：房间内最远点至疏散门直线距离≤15m。门扇后方1.4m安全疏散半径内严禁堆放移动教具、儿童拼图地垫或移动车。"
    ],
    "docBrief": "儿童智力筛查室审图重点包括空间分隔与面积、视听干扰防护、门洞口通行净宽等内容；依据《综合医院建筑设计标准》GB 51039-2014 第3.2.6条；《综合医院建设标准》第三十九条第八款；《综合医院建设标准》第五条、第三十九条第七款复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 4,
      "priority": "P3",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 6,
      "finalStatus": "已完成",
      "finalRequirement": "保留现状并锁定构件锚点。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "opd_child",
    "dept": "门诊",
    "name": "小儿诊室",
    "type": "clinic",
    "priority": "P2",
    "summary": "小儿诊室审图重点包括房间净面积、房间短边净宽、诊查床侧净距等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.2.4条第1款、第5.1.9条第1款；《综合医院建筑设计标准》GB 51039-2014 第5.2.4条第2款复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/门诊/轴测/小儿诊室.png",
      "docs/materials/2026.7.6/门诊/CAD/门诊平面_t3.dwg"
    ],
    "preview": "assets/img/previews/opd_child.jpg",
    "rules": [
      "area",
      "handwash",
      "privacy",
      "child"
    ],
    "siteModel": "models/viewer.html?scene=opd-child",
    "siteModelName": "3D交互信息模型（小儿诊室·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "小儿诊室审图重点包括房间净面积、房间短边净宽、诊查床侧净距等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.2.4条第1款、第5.1.9条第1款；《综合医院建筑设计标准》GB 51039-2014 第5.2.4条第2款复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "房间净面积：单人诊查室的使用面积不应小于8.00㎡。诊查室的室内净高不宜低于2.60m。",
      "房间短边净宽：双人诊查室的开间净尺寸不应小于3.00m，单人诊查室的开间净尺寸不应小于2.50m。",
      "诊查床侧净距：各个功能用房空间尺寸应符合医疗操作规范和防护等相关要求，合理测算医疗行为空间尺度。",
      "门洞口净宽：诊室门净宽不应小于0.90m。",
      "地面防滑：地面应选用防滑、易清洗的材料。",
      "阳角圆弧：儿童诊疗区域的门窗、家具和楼地面等应采取必要的安全保护措施。"
    ],
    "docReview": [
      "空间模数与净空 / 房间净面积：基于4200mm或8400mm标准柱网模块设计，图纸净面积优化为≥12.0㎡，内部预留≥1.5m×1.5m平车与轮椅无障碍回转边界线。",
      "空间模数与净空 / 房间短边净宽：诊室短边（轴线开间）净宽统一执行≥3.0m。图面取消一切透视阴影，确保婴儿车平滑通过。",
      "空间模数与净空 / 诊查床侧净距：诊查桌与诊查床连体布置，去除移动推车。诊查床外侧操作面预留净宽≥0.9m的医护/抱婴家长复合通道。",
      "空间模数与净空 / 门洞口净宽：修正： 淘汰易产生防夹手死角且不便儿童防护的子母门，统一优化为1000mm宽单扇平开木门",
      "室内装修与防护 / 地面防滑：2D平面图纸中设计无缝同质透心PVC地板，防滑等级严格执行≥R11，不画任何背景分格网格线。",
      "室内装修与防护 / 阳角圆弧：室内所有固定家具体、墙体阳角物理上做R≥20mm的圆弧或软包覆，全面消除尖锐棱角。",
      "室内装修与防护 / 墙面防撞软包：诊室及儿童活动区域墙面1.2m以下设置B1级阻燃防撞软包，耐受耐酸碱消毒剂高频擦洗。",
      "建筑防火与疏散 / 装修材料性能：图纸技术说明中明示：顶棚、墙面均采用A级不燃材料，地面与防撞软包材料不低于B1级。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "房间净面积",
        "requirement": "单人诊查室的使用面积不应小于8.00㎡。诊查室的室内净高不宜低于2.60m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.2.4条第1款、第5.1.9条第1款",
        "suggestion": "基于4200mm或8400mm标准柱网模块设计，图纸净面积优化为≥12.0㎡，内部预留≥1.5m×1.5m平车与轮椅无障碍回转边界线。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "房间短边净宽",
        "requirement": "双人诊查室的开间净尺寸不应小于3.00m，单人诊查室的开间净尺寸不应小于2.50m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.2.4条第2款",
        "suggestion": "诊室短边（轴线开间）净宽统一执行≥3.0m。图面取消一切透视阴影，确保婴儿车平滑通过。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "诊查床侧净距",
        "requirement": "各个功能用房空间尺寸应符合医疗操作规范和防护等相关要求，合理测算医疗行为空间尺度。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第3.2.6条第2款",
        "suggestion": "诊查桌与诊查床连体布置，去除移动推车。诊查床外侧操作面预留净宽≥0.9m的医护/抱婴家长复合通道。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "门洞口净宽",
        "requirement": "诊室门净宽不应小于0.90m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.2.4条第4款",
        "suggestion": "修正： 淘汰易产生防夹手死角且不便儿童防护的子母门，统一优化为1000mm宽单扇平开木门"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "地面防滑",
        "requirement": "地面应选用防滑、易清洗的材料。",
        "source": "《综合医院建设标准》第三十九条第四款",
        "suggestion": "2D平面图纸中设计无缝同质透心PVC地板，防滑等级严格执行≥R11，不画任何背景分格网格线。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "阳角圆弧",
        "requirement": "儿童诊疗区域的门窗、家具和楼地面等应采取必要的安全保护措施。",
        "source": "《综合医院建设标准》第三十九条第七款",
        "suggestion": "室内所有固定家具体、墙体阳角物理上做R≥20mm的圆弧或软包覆，全面消除尖锐棱角。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "墙面防撞软包",
        "requirement": "内墙墙体不应使用易裂、易燃、不耐碰撞的材料。",
        "source": "《综合医院建设标准》第三十九条第三款",
        "suggestion": "诊室及儿童活动区域墙面1.2m以下设置B1级阻燃防撞软包，耐受耐酸碱消毒剂高频擦洗。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "装修材料性能",
        "requirement": "医疗建筑内的诊疗室，其内部装修材料的燃烧性能均应为A级（顶棚、墙面）和不低于B1级（地面）。",
        "source": "《建筑防火通用规范》GB 55037-2022 第6.5.6条",
        "suggestion": "图纸技术说明中明示：顶棚、墙面均采用A级不燃材料，地面与防撞软包材料不低于B1级。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "排烟设施",
        "requirement": "建筑的疏散走道、人员密集的场所应依法设置防烟与排烟设施。",
        "source": "《建筑防火通用规范》GB 55037-2022 第8.2.1条",
        "suggestion": "无自然通风条件时，诊室必须规划吊顶内机械排烟风管点位，保障其独立防烟性能。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "疏散门方向",
        "requirement": "民用建筑内各房间疏散门的开启方向：应向疏散方向开启。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.4条",
        "suggestion": "平面图纸中诊室平开门必须向疏散走廊方向开启。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "疏散门净宽",
        "requirement": "疏散走道、疏散门的净宽度均不应小于1.1m（注：此处指公共通道，诊室单扇门通行宽度执行医疗工艺1.0m标准）。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.4条第3款",
        "suggestion": "确保诊室门开启后不应减少走廊的有效疏散净宽（走廊单侧候诊需维持≥2.4m，两侧≥3.0m）。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "双高度手卫生",
        "requirement": "诊室、检验科等房间的洗手盆应采用非手动开关，并应采取防止污水外溅的措施。儿科等区域卫生间应设置儿童专用洁具。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第6.2.5条第4款；《综合医院建设标准》第三十九条第六款",
        "suggestion": "诊室入口直通线上刚性配置非接触式感应洗手盆。可采用多级高度台面（儿童0.55m，成人0.80m），盆体做防喷溅工艺优化。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "高频接触面",
        "requirement": "阳角及高频接触面应易清洁消毒。台面、操作台等台面均应采用易洁净、耐腐蚀、可冲洗的面层。",
        "source": "《综合医院建设标准》第三十九条第六款、第五款",
        "suggestion": "采用整体抗菌无缝实体面材台面。中文简体粗体标签（如：洗手盆、诊查床）一律100%内置于几何线框内，取消外引线。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "医疗废物收集",
        "requirement": "医疗业务用房应符合医院感染预防与控制的基本原则，易于冲洗、消毒。",
        "source": "《儿童医院建设标准》建标174-2016 第三十四条",
        "suggestion": "诊室尽端隐蔽处设置独立有盖医疗废物收集容器点位，严禁摆放在公共视线与儿童易触碰区域。"
      }
    ],
    "glbModel": "glb/opd-child.glb",
    "glbModelDisabled": true,
    "glbModelStatus": "逐房间复核标记为尺度/游离构件异常，待重新归零导出后启用",
    "legacySiteModel": "models/external/儿童诊室3D模型_独立版.html",
    "sceneInfo": {
      "thumb": "assets/img/scene-thumbs/opd-child.jpg",
      "area": "3.30 × 4.80 m · 净高 2.80m（≈15.8㎡，可参数化）",
      "dims": {
        "def": [
          3.3,
          4.8,
          2.8
        ],
        "min": [
          3,
          3.7,
          2.7
        ],
        "sugg": [
          3.6,
          5.1,
          2.9
        ],
        "minLabel": "建标174 最低",
        "suggLabel": "图则建议"
      },
      "stats": {
        "furn": 13,
        "markers": 8
      },
      "cost": "约 0.9–4.5 万元"
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 12,
      "priority": "P2",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 14,
      "finalStatus": "部分完成",
      "finalRequirement": "洗手盆与检查床分离；陪护椅和体重秤退出门区；复核量测表与 GLB。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）",
    "glbModelDisabledReason": "2026-07-13 GLB 包围核查发现尺度、原点或游离构件异常；程序场景保留，清理并统一米制重导前禁用实景切换。",
    "glbAuditStatus": "隔离待重导"
  },
  {
    "id": "opd_dental",
    "dept": "门诊",
    "name": "口腔科诊室",
    "type": "clinic",
    "priority": "P0",
    "summary": "口腔科诊室审图重点包括房间净面积、牙椅侧操作净距、清洗区面积等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.2.22条；《综合医院建筑设计标准》GB 51039-2014 第3.2.6条第2款复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/门诊/行为示意图/口腔诊室.png",
      "docs/materials/2026.7.6/门诊/轴测/口腔诊室.png",
      "docs/materials/2026.7.6/门诊/CAD/门诊平面_t3.dwg"
    ],
    "rules": [
      "area",
      "handwash",
      "privacy",
      "child"
    ],
    "siteModel": "models/viewer.html?scene=opd-dental",
    "siteModelName": "3D交互信息模型（口腔科诊室·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "口腔科诊室审图重点包括房间净面积、牙椅侧操作净距、清洗区面积等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.2.22条；《综合医院建筑设计标准》GB 51039-2014 第3.2.6条第2款复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "房间净面积：口腔科诊疗单元每椅中距不应小于1.80m，椅中心距墙不应小于1.20m；诊疗单元的尽端净宽不不应小于2.50m",
      "牙椅侧操作净距：医疗业务用房设计应合理测算医疗行为及设备工位空间尺度。",
      "清洗区面积：相关的洗涤池和排水管亦应采用耐腐蚀的材料。",
      "门洞口净宽：门诊部用房的门洞口净宽不应小于0.90m。",
      "地面防滑与洁净：地面应选用防滑、易清洗的材料。",
      "界面防磕碰阳角：儿童诊疗区域的门窗、家具和楼地面等应采取必要的安全保护措施。"
    ],
    "docReview": [
      "空间模数与净空 / 房间净面积：独立诊室净面积优化为≥15.0㎡（含家长陪护专属区）。",
      "空间模数与净空 / 牙椅侧操作净距：牙椅两侧及尾端预留操作净距≥1.0m。地坪内部须精准规划牙椅专用的上下水、负压吸引、压缩空气及强弱电的暗埋管网交汇点。",
      "空间模数与净空 / 清洗区面积：诊室内清洗区净面积≥2.0㎡。台面、洗涤池、排水管均需采用耐酸碱腐蚀的特种不锈钢材质，台面做防溢水沿。",
      "空间模数与净空 / 门洞口净宽：淘汰易夹手、影响气密的双开门或子母门。优化为1100mm 宽单扇平开医疗木门（配自闭装置、门禁与双向防夹手软护条），确保牙科综合治疗机及轮椅顺利通过。",
      "室内装修与防护 / 地面防滑与洁净：设计无缝同质透心防滑 PVC 地板，防滑等级严格执行 ≥R11，踢脚线处做 R≥30mm 墙地一体化上墙上翻 150mm，不画地砖分格线。",
      "室内装修与防护 / 界面防磕碰阳角：室内所有固定技术柜体、清洗台、墙体及隔断阳角物理上做R≥20mm 的圆弧或全软包覆，彻底消除棱角。",
      "室内装修与防护 / 抗菌防污墙裙：诊室内 100% 设置 1.5m 高抗菌防污一体化墙裙（如抗菌树脂板），高频耐受口腔喷溅物及医用消毒剂擦洗。",
      "建筑防火与疏散 / 装修材料性能：图纸技术说明中明示：顶棚、墙面均采用 A 级不燃材料，地面及固定家具材料不低于B1 级阻燃。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "房间净面积",
        "requirement": "口腔科诊疗单元每椅中距不应小于1.80m，椅中心距墙不应小于1.20m；诊疗单元的尽端净宽不不应小于2.50m",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.2.22条",
        "suggestion": "独立诊室净面积优化为≥15.0㎡（含家长陪护专属区）。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "牙椅侧操作净距",
        "requirement": "医疗业务用房设计应合理测算医疗行为及设备工位空间尺度。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第3.2.6条第2款",
        "suggestion": "牙椅两侧及尾端预留操作净距≥1.0m。地坪内部须精准规划牙椅专用的上下水、负压吸引、压缩空气及强弱电的暗埋管网交汇点。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "清洗区面积",
        "requirement": "相关的洗涤池和排水管亦应采用耐腐蚀的材料。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.12条第3款",
        "suggestion": "诊室内清洗区净面积≥2.0㎡。台面、洗涤池、排水管均需采用耐酸碱腐蚀的特种不锈钢材质，台面做防溢水沿。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "门洞口净宽",
        "requirement": "门诊部用房的门洞口净宽不应小于0.90m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.2.4条第4款",
        "suggestion": "淘汰易夹手、影响气密的双开门或子母门。优化为1100mm 宽单扇平开医疗木门（配自闭装置、门禁与双向防夹手软护条），确保牙科综合治疗机及轮椅顺利通过。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "地面防滑与洁净",
        "requirement": "地面应选用防滑、易清洗的材料。",
        "source": "《综合医院建设标准》第三十九条第四款",
        "suggestion": "设计无缝同质透心防滑 PVC 地板，防滑等级严格执行 ≥R11，踢脚线处做 R≥30mm 墙地一体化上墙上翻 150mm，不画地砖分格线。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "界面防磕碰阳角",
        "requirement": "儿童诊疗区域的门窗、家具和楼地面等应采取必要的安全保护措施。",
        "source": "《综合医院建设标准》第三十九条第七款",
        "suggestion": "室内所有固定技术柜体、清洗台、墙体及隔断阳角物理上做R≥20mm 的圆弧或全软包覆，彻底消除棱角。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "抗菌防污墙裙",
        "requirement": "内墙墙体不应使用不耐碰撞、不易吊挂的材料。",
        "source": "《综合医院建设标准》第三十九条第三款",
        "suggestion": "诊室内 100% 设置 1.5m 高抗菌防污一体化墙裙（如抗菌树脂板），高频耐受口腔喷溅物及医用消毒剂擦洗。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "装修材料性能",
        "requirement": "医疗建筑内的诊疗室、治疗室等，其内部装修材料的燃烧性能均应为A级（顶棚、墙面）和不低于 B1 级（地面）。",
        "source": "《建筑防火通用规范》GB 55037-2022 第6.5.6条",
        "suggestion": "图纸技术说明中明示：顶棚、墙面均采用 A 级不燃材料，地面及固定家具材料不低于B1 级阻燃。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "局部机械排烟",
        "requirement": "建筑的疏散走道、人员密集的场所应依法设置防烟与排烟设施。",
        "source": "《建筑防火通用规范》GB 55037-2022 第8.2.1条",
        "suggestion": "无自然通风条件时，必须规划吊顶内机械排烟风管点位，排风量严格执行 ≥30m³/h/椅，确保快速排除洁治、备牙时产生的气溶胶。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "疏散门开启方向",
        "requirement": "民用建筑内各房间疏散门的开启方向：应向疏散方向开启。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.4条",
        "suggestion": "平面图纸中诊室平开门必须向疏散走廊方向开启（顺疏散方向）。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "疏散有效宽度",
        "requirement": "疏散走道、疏散门的净宽度均不应小于1.1m。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.4条第3款",
        "suggestion": "确保口腔诊室门开启后，不应减少外侧疏散走廊的有效有效净宽（走廊单侧候诊需维持 ≥2.4m，两侧 ≥3.0m）。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "疏散路径畅通",
        "requirement": "建筑内的安全出口和疏散门应分散布置，严禁占用。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.1条",
        "suggestion": "房间内最远点至疏散门直线距离≤15m。门扇后方 1.4m 安全疏散半径内严禁堆放任何牙科移动柜、推车或家属候诊凳。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "非接触手卫生",
        "requirement": "诊室、治疗室等房间的洗手盆应采用非手动开关，并应采取防止污水外溅的措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第6.2.5条第4款",
        "suggestion": "诊室入口及清洗区分别刚性配置非接触式感应洗手盆（流线无绕行），盆体加深做防喷溅优化。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "洁污防交叉污染",
        "requirement": "医疗业务用房应符合医院感染预防与控制的基本原则，洁污流线组织清晰。",
        "source": "《儿童医院建设标准》建标 174-2016 第三十四条、第二十三条",
        "suggestion": "清洗区与诊疗区间设置物理玻璃隔断或设置独立器械净化间，并通过双扉互锁式不锈钢传递窗连接。简体中文粗体标签100%内置于图面线框内。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "独立医废收集",
        "requirement": "医疗业务用房废弃物应封闭处理。",
        "source": "《儿童医院建设标准》建标 174-2016 第三十四条",
        "suggestion": "牙椅尾端隐蔽处及清洗区分别规划嵌壁隐藏式、带盖密封式分类医疗废物（特别是涉及锐器及唾液污染废物）收集点位。"
      }
    ],
    "preview": "assets/img/previews/opd_dental.jpg",
    "sceneInfo": {
      "thumb": "assets/img/scene-thumbs/opd-dental.jpg",
      "area": "2.80 × 4.60 m · 净高 2.9m（≈12.9㎡，按图 4600×2800）",
      "dims": {
        "def": [
          2.8,
          4.6,
          2.9
        ],
        "min": [
          2.6,
          4.2,
          2.7
        ],
        "sugg": [
          2.8,
          4.6,
          2.9
        ],
        "minLabel": "口腔室最低",
        "suggLabel": "图则平面"
      },
      "stats": {
        "furn": 11,
        "markers": 9
      },
      "cost": "约 2.6–15.6 万元"
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 6,
      "priority": "P0",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 8,
      "finalStatus": "部分完成",
      "finalRequirement": "工作台贴东墙；牙椅设备外廓独立；补衣帽挂点及牙椅工作/停泊状态。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "opd_double",
    "dept": "门诊",
    "name": "双人诊室",
    "type": "clinic",
    "priority": "P3",
    "summary": "双人诊室审图重点包括房间净面积、诊疗位之间净距、诊查床侧操作净距等内容；依据《综合医院建筑设计规范》GB 51039-2014；《医疗机构感染预防与控制基本准则》GB/T 39498-2020复核规范要求，并结合儿童医院陪护、感控、净距和设备接口进行优化。",
    "assets": [
      "docs/materials/门诊/门诊平面_t3.dwg"
    ],
    "rules": [
      "area",
      "handwash",
      "privacy",
      "child"
    ],
    "siteModel": "models/viewer.html?scene=opd-double",
    "siteModelName": "3D交互信息模型（双人诊室·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "双人诊室审图重点包括房间净面积、诊疗位之间净距、诊查床侧操作净距等内容；依据《综合医院建筑设计规范》GB 51039-2014；《医疗机构感染预防与控制基本准则》GB/T 39498-2020复核规范要求，并结合儿童医院陪护、感控、净距和设备接口进行优化。",
    "docFacts": [
      "房间净面积：净面积≥16㎡",
      "诊疗位之间净距：诊疗位之间净距≥1.2m",
      "诊查床侧操作净距：诊查床侧操作净距≥0.75m",
      "门洞口净宽：门洞口净宽≥0.9m",
      "手卫生设施：每个诊疗单元附近应设置手卫生设施"
    ],
    "docReview": [
      "空间模数与净空 / 房间净面积：净面积≥18㎡，预留双诊疗位独立操作空间",
      "空间模数与净空 / 诊疗位之间净距：诊疗位之间净距≥1.5m，设置隔音隔断",
      "空间模数与净空 / 诊查床侧操作净距：诊查床侧操作净距≥0.9m，满足双诊疗位同时操作",
      "空间模数与净空 / 门洞口净宽：门洞口净宽≥1.2m，采用双开门，便于设备通行",
      "感控要求与设施 / 手卫生设施：两诊疗位各设置独立非接触式洗手池"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "房间净面积",
        "requirement": "净面积≥16㎡",
        "source": "《综合医院建筑设计规范》GB 51039-2014",
        "suggestion": "净面积≥18㎡，预留双诊疗位独立操作空间"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "诊疗位之间净距",
        "requirement": "诊疗位之间净距≥1.2m",
        "source": "《综合医院建筑设计规范》GB 51039-2014",
        "suggestion": "诊疗位之间净距≥1.5m，设置隔音隔断"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "诊查床侧操作净距",
        "requirement": "诊查床侧操作净距≥0.75m",
        "source": "《综合医院建筑设计规范》GB 51039-2014",
        "suggestion": "诊查床侧操作净距≥0.9m，满足双诊疗位同时操作"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "门洞口净宽",
        "requirement": "门洞口净宽≥0.9m",
        "source": "《综合医院建筑设计规范》GB 51039-2014",
        "suggestion": "门洞口净宽≥1.2m，采用双开门，便于设备通行"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "手卫生设施",
        "requirement": "每个诊疗单元附近应设置手卫生设施",
        "source": "《医疗机构感染预防与控制基本准则》GB/T 39498-2020",
        "suggestion": "两诊疗位各设置独立非接触式洗手池"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "疗位间防污隔断",
        "requirement": "诊疗位之间应设置防污、隔音隔断",
        "source": "《医疗机构感染预防与控制基本准则》GB/T 39498-2020",
        "suggestion": "设置1.5m高不透明防污隔断，避免交叉污染"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "独立医疗废物收集点",
        "requirement": "诊疗区应设置独立医疗废物收集容器",
        "source": "《医疗机构感染预防与控制基本准则》GB/T 39498-2020",
        "suggestion": "配置双分类垃圾桶，分别服务两个诊疗位"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "地面防滑等级是否达标",
        "requirement": "地面防滑等级≥R10",
        "source": "《儿童医院建设标准》建标174-2016",
        "suggestion": "采用同质透心防滑PVC地板，防滑等级≥R11"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "阳角圆弧处理",
        "requirement": "儿童可触及部位阳角应做成圆弧",
        "source": "《儿童医院建设标准》建标174-2016",
        "suggestion": "所有阳角R≥20mm，避免磕碰伤害"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "隔断防撞处理",
        "requirement": "诊疗位隔断应设置防撞处理",
        "source": "《儿童医院建设标准》建标174-2016",
        "suggestion": "隔断边缘做圆角处理，设置防撞条"
      },
      {
        "dimension": "安全出口与疏散门",
        "focus": "疏散门开启方向是",
        "requirement": "疏散门应向疏散方向开启",
        "source": "《建筑设计防火规范》GB 50016-2014（2018版）",
        "suggestion": "采用自闭式门体，平时保持关闭状态"
      },
      {
        "dimension": "安全出口与疏散门",
        "focus": "疏散门净宽",
        "requirement": "疏散门净宽≥0.9m",
        "source": "《建筑设计防火规范》GB 50016-2014（2018版）",
        "suggestion": "采用双开门，净宽≥1.2m，便于多人同时疏散"
      },
      {
        "dimension": "安全出口与疏散门",
        "focus": "疏散路径",
        "requirement": "房间内最远点至门的距离≤15m",
        "source": "《建筑设计防火规范》GB 50016-2014（2018版）",
        "suggestion": "两诊疗位布置不遮挡疏散路径，门后1.4m无障碍物"
      },
      {
        "dimension": "装修材料与防火",
        "focus": "室内装修材料燃烧性能",
        "requirement": "医疗建筑室内装修材料燃烧性能≥B1级",
        "source": "《建筑设计防火规范》GB 50016-2014（2018版）",
        "suggestion": "顶棚、墙面、地面采用A级不燃材料，隔断为B1级阻燃"
      },
      {
        "dimension": "装修材料与防火",
        "focus": "排烟设施",
        "requirement": "无自然排烟条件时应设置机械排烟",
        "source": "《建筑设计防火规范》GB 50016-2014（2018版）",
        "suggestion": "配置双诊疗位独立排烟，总排风量≥120m³/h"
      },
      {
        "dimension": "装修材料与防火",
        "focus": "应急照明",
        "requirement": "疏散照明地面照度≥1.0lx，持续供电≥0.5h",
        "source": "《建筑设计防火规范》GB 50016-2014（2018版）",
        "suggestion": "应急照明覆盖两个诊疗位，无照明死角"
      }
    ],
    "preview": "assets/img/previews/opd_double.jpg",
    "sceneInfo": {
      "thumb": "assets/img/scene-thumbs/opd-double.jpg",
      "area": "4.20 × 5.40 m · 净高 2.9m（≈22.7㎡，推测补全）",
      "dims": {
        "def": [
          4.2,
          5.4,
          2.9
        ],
        "min": [
          3,
          4.8,
          2.7
        ],
        "sugg": [
          4.4,
          5.6,
          3
        ],
        "minLabel": "GB 51039 双人最低",
        "suggLabel": "图则建议"
      },
      "stats": {
        "furn": 14,
        "markers": 9
      },
      "cost": "约 0.5–2.1 万元"
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 10,
      "priority": "P3",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 12,
      "finalStatus": "已完成",
      "finalRequirement": "陪护人员与诊床补 supportId 绑定。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "opd_injection",
    "dept": "门诊",
    "name": "注射室",
    "type": "treatment",
    "priority": "P3",
    "summary": "注射室审图重点包括空间分隔与面积、注射位操作净距、门洞口净宽等内容；依据《综合医院建筑设计标准》GB 51039-2014 第3.2.6条、第5.2.14条；《综合医院建筑设计标准》GB 51039-2014 第3.2.6条第2款复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/门诊/行为示意图/注射室.png",
      "docs/materials/2026.7.6/门诊/轴测/注射室.png",
      "docs/materials/2026.7.6/门诊/CAD/门诊平面_t3.dwg"
    ],
    "preview": "assets/img/previews/opd_injection.jpg",
    "rules": [
      "infection",
      "handwash",
      "nursing"
    ],
    "siteModel": "models/viewer.html?scene=opd-injection",
    "siteModelName": "3D交互信息模型（注射室·新版）",
    "sceneInfo": {
      "thumb": "assets/img/scene-thumbs/opd-injection.jpg",
      "area": "3.60 × 4.80 m · 净高 2.80m（≈17.3㎡，可参数化）",
      "dims": {
        "def": [
          3.6,
          4.8,
          2.8
        ],
        "min": [
          2.8,
          3.6,
          2.7
        ],
        "sugg": [
          3.9,
          5.2,
          2.9
        ],
        "minLabel": "GB 51039 最低",
        "suggLabel": "图则建议"
      },
      "stats": {
        "furn": 11,
        "markers": 9
      },
      "cost": "约 1.1–4.5 万元"
    },
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "空间分隔与面积",
        "requirement": "各个功能用房空间尺寸应符合医疗操作规范。注射室应设配药操作区和注射区。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第3.2.6条、第5.2.14条",
        "suggestion": "基于8400mm或4200mm标准柱网，设置物理玻璃隔断区分配药准备区与儿科注射区。整体净面积建议≥20.0㎡。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "注射位操作净距",
        "requirement": "医疗业务用房设计应合理测算医疗行为及设备工位空间尺度。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第3.2.6条第2款",
        "suggestion": "注射台单侧或双侧配制家长陪护抱娃空间。单座位工艺包边界≥1.2m×1.2m，注射桌与药柜连体布置，取消移动车。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "门洞口净宽",
        "requirement": "门诊部用房的门洞口净宽不应小于0.90m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.2.4条第4款",
        "suggestion": "优化： 统一采用1100mm宽单扇平开医疗木门（配闭门器、门禁及双向防夹手软护条），保障推车与抱娃家长快速通过，严禁使用子母门。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "非接触手卫生",
        "requirement": "诊室、治疗室等房间的洗手盆应采用非手动开关，并应采取防止污水外溅的措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第6.2.5条第4款",
        "suggestion": "配药区与注射区分别刚性配置非接触式感应洗手盆（或感应速干手消点）。洗手盆做凹陷防喷溅设计，避免幼儿溅水。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "界面防磕碰阳角",
        "requirement": "儿童诊疗区域的门窗、家具和楼地面等应采取必要的安全保护措施。",
        "source": "《综合医院建设标准》第三十九条第七款",
        "suggestion": "室内所有固定配药柜体、注射台、隔断外露阳角物理上做R≥20mm的圆弧或防撞包覆，消除任何尖锐棱角。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "阻燃墙面软包",
        "requirement": "内墙墙体不应使用易裂、易燃、不耐碰撞的材料。",
        "source": "《综合医院建设标准》第三十九条第三款",
        "suggestion": "注射位靠墙处1.2m以下设置B1级阻燃防撞软包，避免患儿因抗拒注射挣扎碰撞，面层须耐受高浓度消毒剂高频擦洗。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "疏散门开启方向",
        "requirement": "民用建筑内各房间疏散门的开启方向：应向疏散方向开启。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.4条",
        "suggestion": "平面图纸中注射室平开门必须向疏散走廊方向开启（顺疏散方向）。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "独立排烟与通风",
        "requirement": "建筑的疏散走道、人员密集的场所应依法设置防烟与排烟设施。",
        "source": "《建筑防火通用规范》GB 55037-2022 第8.2.1条",
        "suggestion": "无自然通风条件时，注射室吊顶内必须规划机械排烟风管点位，排风量≥80m³/h，保障空间独立防烟性能。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "空间分隔与面积",
        "requirement": "各个功能用房空间尺寸应符合医疗操作规范。注射室应设配药操作区和注射区。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第3.2.6条、第5.2.14条",
        "suggestion": "基于8400mm或4200mm标准柱网，设置物理玻璃隔断区分配药准备区与儿科注射区。整体净面积建议≥20.0㎡。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "疏散有效宽度",
        "requirement": "疏散走道、疏散门的净宽度均不应小于1.1m。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.4条第3款",
        "suggestion": "确保注射室大门开启后，不应减少外侧疏散走廊的有效净宽（走廊单侧候诊需维持≥2.4m，两侧≥3.0m）。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "疏散路径畅通",
        "requirement": "建筑内的安全出口和疏散门应分散布置，严禁占用。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.1条",
        "suggestion": "房间内最远点至疏散门直线距离≤15m。门扇后方1.4m安全疏散半径内严禁堆放移动垃圾桶或移动药车。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "装修材料性能",
        "requirement": "医疗建筑内的治疗室、配药室等，其内部装修材料的燃烧性能均应为A级（顶棚、墙面）和不低于B1级（地面）。",
        "source": "《建筑防火通用规范》GB 55037-2022 第6.5.6条",
        "suggestion": "图纸技术说明中明示：顶棚、墙面均采用A级不燃材料，地面及防撞软包装饰材料不低于B1级阻燃。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "空气与接触感控",
        "requirement": "医疗业务用房应符合医院感染预防与控制的基本原则。台面均应采用易洁净、耐腐蚀、可冲洗的面层。",
        "source": "《儿童医院建设标准》建标174-2016 第三十四条；《综合医院建设标准》第三十九条",
        "suggestion": "配药台采用抗菌无缝整体实体面材（不锈钢或人造石）。2D图面上所有中文简体粗体标签（如：配药台、洗手盆）100%内置于线框内。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "医废与锐器收集",
        "requirement": "医疗业务用房应易于冲洗、消毒，废弃物封闭处理。",
        "source": "《儿童医院建设标准》建标174-2016 第三十四条",
        "suggestion": "每个注射位台面下方隐蔽处刚性预留利器盒与医疗垃圾桶固定点位，严禁暴露在儿童可触及的视线范围内。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "地面防滑与洁净",
        "requirement": "地面应选用防滑、易清洗的材料。",
        "source": "《综合医院建设标准》第三十九条第四款",
        "suggestion": "2D平面中设计无缝同质透心防滑PVC地板，防滑等级严格执行≥R11，不画任何多余的背景分格线条与阴影。"
      }
    ],
    "docFacts": [
      "空间分隔与面积：各个功能用房空间尺寸应符合医疗操作规范。注射室应设配药操作区和注射区。",
      "注射位操作净距：医疗业务用房设计应合理测算医疗行为及设备工位空间尺度。",
      "门洞口净宽：门诊部用房的门洞口净宽不应小于0.90m。",
      "非接触手卫生：诊室、治疗室等房间的洗手盆应采用非手动开关，并应采取防止污水外溅的措施。",
      "界面防磕碰阳角：儿童诊疗区域的门窗、家具和楼地面等应采取必要的安全保护措施。",
      "阻燃墙面软包：内墙墙体不应使用易裂、易燃、不耐碰撞的材料。"
    ],
    "docReview": [
      "空间模数与净空 / 空间分隔与面积：基于8400mm或4200mm标准柱网，设置物理玻璃隔断区分配药准备区与儿科注射区。整体净面积建议≥20.0㎡。",
      "空间模数与净空 / 注射位操作净距：注射台单侧或双侧配制家长陪护抱娃空间。单座位工艺包边界≥1.2m×1.2m，注射桌与药柜连体布置，取消移动车。",
      "空间模数与净空 / 门洞口净宽：优化： 统一采用1100mm宽单扇平开医疗木门（配闭门器、门禁及双向防夹手软护条），保障推车与抱娃家长快速通过，严禁使用子母门。",
      "空间模数与净空 / 非接触手卫生：配药区与注射区分别刚性配置非接触式感应洗手盆（或感应速干手消点）。洗手盆做凹陷防喷溅设计，避免幼儿溅水。",
      "室内装修与防护 / 界面防磕碰阳角：室内所有固定配药柜体、注射台、隔断外露阳角物理上做R≥20mm的圆弧或防撞包覆，消除任何尖锐棱角。",
      "室内装修与防护 / 阻燃墙面软包：注射位靠墙处1.2m以下设置B1级阻燃防撞软包，避免患儿因抗拒注射挣扎碰撞，面层须耐受高浓度消毒剂高频擦洗。",
      "室内装修与防护 / 疏散门开启方向：平面图纸中注射室平开门必须向疏散走廊方向开启（顺疏散方向）。",
      "建筑防火与疏散 / 独立排烟与通风：无自然通风条件时，注射室吊顶内必须规划机械排烟风管点位，排风量≥80m³/h，保障空间独立防烟性能。"
    ],
    "docBrief": "注射室审图重点包括空间分隔与面积、注射位操作净距、门洞口净宽等内容；依据《综合医院建筑设计标准》GB 51039-2014 第3.2.6条、第5.2.14条；《综合医院建筑设计标准》GB 51039-2014 第3.2.6条第2款复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 14,
      "priority": "P3",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 16,
      "finalStatus": "部分完成",
      "finalRequirement": "移除门区座椅，保持连续通行；补人物 support/workTarget。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "opd_mother",
    "dept": "门诊",
    "name": "母婴室",
    "type": "toilet",
    "priority": "P2",
    "summary": "面向哺乳、换尿布、短暂停留和清洁需求的亲子支持空间。",
    "assets": [
      "docs/materials/门诊/门诊平面_t3.dwg",
      "docs/materials/门诊/母婴室.png"
    ],
    "preview": "assets/img/previews/opd_mother.jpg",
    "rules": [
      "accessible",
      "child",
      "handwash"
    ],
    "siteModel": "models/viewer.html?scene=opd-mother",
    "siteModelName": "3D交互信息模型（母婴室·新版）",
    "sceneInfo": {
      "thumb": "assets/img/scene-thumbs/opd-mother.jpg",
      "area": "4.20 × 4.20 m · 净高 2.9m（≈17.6㎡，按图 4200×4200）",
      "dims": {
        "def": [
          4.2,
          4.2,
          2.9
        ],
        "min": [
          3,
          4.2,
          2.7
        ],
        "sugg": [
          4.2,
          4.2,
          2.9
        ],
        "minLabel": "母婴室最低",
        "suggLabel": "图则平面"
      },
      "stats": {
        "furn": 8,
        "markers": 9
      },
      "cost": "约 1.0–4.1 万元"
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 8,
      "priority": "P2",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 10,
      "finalStatus": "部分完成",
      "finalRequirement": "第三座椅与婴儿床分离；隔帘闭合完整；护理台退出门区；补第三人物承托。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "opd_neonatal_observe",
    "dept": "门诊",
    "name": "新生儿观察室",
    "type": "clinic",
    "priority": "P1",
    "summary": "新生儿观察室审图重点包括房间净面积、暖箱/观察床侧操作净距、家长操作区面积等内容；依据《儿童医院建设标准》建标174-2016；《医疗机构感染预防与控制基本准则》GB/T 39498-2020复核规范要求，并结合儿童医院陪护、感控、净距和设备接口进行优化。",
    "assets": [
      "docs/materials/门诊/门诊平面_t3.dwg"
    ],
    "rules": [
      "area",
      "handwash",
      "privacy",
      "child"
    ],
    "siteModel": "models/viewer.html?scene=opd-neonatal",
    "siteModelName": "3D交互信息模型（新生儿观察室·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "新生儿观察室审图重点包括房间净面积、暖箱/观察床侧操作净距、家长操作区面积等内容；依据《儿童医院建设标准》建标174-2016；《医疗机构感染预防与控制基本准则》GB/T 39498-2020复核规范要求，并结合儿童医院陪护、感控、净距和设备接口进行优化。",
    "docFacts": [
      "房间净面积：净面积≥12㎡",
      "暖箱/观察床侧操作净距：操作净距≥0.8m",
      "家长操作区面积：家长操作区面积≥2㎡",
      "门洞口净宽：门洞口净宽≥0.9m",
      "诊疗区手卫生设施：诊疗单元附近应设置手卫生设施"
    ],
    "docReview": [
      "空间模数与净空 / 房间净面积：净面积≥14㎡，分为观察区与护理区",
      "空间模数与净空 / 暖箱/观察床侧操作净距：操作净距≥1.0m，便于医护与家属同时护理",
      "空间模数与净空 / 家长操作区面积：家长操作区面积≥3㎡，便于指导喂养、护理",
      "空间模数与净空 / 门洞口净宽：门洞口净宽≥1.1m，采用子母门，便于暖箱与平车通行",
      "感控要求与设施 / 诊疗区手卫生设施：洗手池设置在入口处，进入前必须手卫生"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "房间净面积",
        "requirement": "净面积≥12㎡",
        "source": "《儿童医院建设标准》建标174-2016",
        "suggestion": "净面积≥14㎡，分为观察区与护理区"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "暖箱/观察床侧操作净距",
        "requirement": "操作净距≥0.8m",
        "source": "《儿童医院建设标准》建标174-2016",
        "suggestion": "操作净距≥1.0m，便于医护与家属同时护理"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "家长操作区面积",
        "requirement": "家长操作区面积≥2㎡",
        "source": "《儿童医院建设标准》建标174-2016",
        "suggestion": "家长操作区面积≥3㎡，便于指导喂养、护理"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "门洞口净宽",
        "requirement": "门洞口净宽≥0.9m",
        "source": "《儿童医院建设标准》建标174-2016",
        "suggestion": "门洞口净宽≥1.1m，采用子母门，便于暖箱与平车通行"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "诊疗区手卫生设施",
        "requirement": "诊疗单元附近应设置手卫生设施",
        "source": "《医疗机构感染预防与控制基本准则》GB/T 39498-2020",
        "suggestion": "洗手池设置在入口处，进入前必须手卫生"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "高频接触面耐消毒",
        "requirement": "台面、地面等高频接触面应采用耐消毒材料",
        "source": "《医疗机构感染预防与控制基本准则》GB/T 39498-2020",
        "suggestion": "采用整体抗菌台面与无缝墙裙，便于冲洗消毒"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "独立医疗废物收集点",
        "requirement": "诊疗区应设置独立医疗废物收集容器",
        "source": "《医疗机构感染预防与控制基本准则》GB/T 39498-2020",
        "suggestion": "配置带盖密封式分类垃圾桶，避免污染"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "地面防滑等级",
        "requirement": "地面防滑等级≥R10",
        "source": "《儿童医院建设标准》建标174-2016",
        "suggestion": "采用同质透心防滑PVC地板，防滑等级≥R11"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "阳角圆弧处理",
        "requirement": "儿童可触及部位阳角应做成圆弧",
        "source": "《儿童医院建设标准》建标174-2016",
        "suggestion": "所有阳角R≥20mm，避免磕碰伤害"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "墙面防撞软包",
        "requirement": "新生儿活动区域应设置防撞软包",
        "source": "《儿童医院建设标准》建标174-2016",
        "suggestion": "墙面1.2m以下设置阻燃防撞软包"
      },
      {
        "dimension": "安全出口与疏1.9厘米散门",
        "focus": "疏散门开启方向",
        "requirement": "疏散门应向疏散方向开启",
        "source": "《建筑设计防火规范》GB 50016-2014（2018版）",
        "suggestion": "采用自闭式门体，平时保持关闭状态"
      },
      {
        "dimension": "安全出口与疏1.9厘米散门",
        "focus": "疏散门净宽",
        "requirement": "疏散门净宽≥0.9m",
        "source": "《建筑设计防火规范》GB 50016-2014（2018版）",
        "suggestion": "采用子母门，净宽≥1.1m，便于暖箱与平车疏散"
      },
      {
        "dimension": "安全出口与疏1.9厘米散门",
        "focus": "疏散路径",
        "requirement": "房间内最远点至门的距离≤15m",
        "source": "《建筑设计防火规范》GB 50016-2014（2018版）",
        "suggestion": "暖箱布置不遮挡疏散路径，门后1.4m无障碍物"
      },
      {
        "dimension": "装修材料与防火",
        "focus": "室内装修材料燃烧性能",
        "requirement": "医疗建筑室内装修材料燃烧性能≥B1级",
        "source": "《建筑设计防火规范》GB 50016-2014（2018版）",
        "suggestion": "顶棚、墙面、地面采用A级不燃材料，软包为B1级阻燃"
      },
      {
        "dimension": "装修材料与防火",
        "focus": "排烟设施",
        "requirement": "无自然排烟条件时应设置机械排烟",
        "source": "《建筑设计防火规范》GB 50016-2014（2018版）",
        "suggestion": "配置低噪音独立机械排烟，排风量≥60m³/h"
      },
      {
        "dimension": "装修材料与防火",
        "focus": "应急照明",
        "requirement": "疏散照明地面照度≥1.0lx，持续供电≥0.5h",
        "source": "《建筑设计防火规范》GB 50016-2014（2018版）",
        "suggestion": "采用柔光型应急照明，避免强光刺激新生儿"
      }
    ],
    "preview": "assets/img/previews/opd_neonatal_observe.jpg",
    "sceneInfo": {
      "thumb": "assets/img/scene-thumbs/opd-neonatal.jpg",
      "area": "3.90 × 5.10 m · 净高 2.9m（≈19.9㎡，推测补全）",
      "dims": {
        "def": [
          3.9,
          5.1,
          2.9
        ],
        "min": [
          3.3,
          4.5,
          2.7
        ],
        "sugg": [
          4.2,
          5.4,
          3
        ],
        "minLabel": "观察室最低",
        "suggLabel": "图则建议"
      },
      "stats": {
        "furn": 8,
        "markers": 9
      },
      "cost": "约 5.2–36.2 万元"
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 13,
      "priority": "P1",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 15,
      "finalStatus": "部分完成",
      "finalRequirement": "锐器盒回治疗侧；补清洁、污物与抢救停靠位。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "opd_registration",
    "dept": "门诊",
    "name": "收费挂号室",
    "type": "waiting",
    "priority": "P3",
    "summary": "收费挂号室审图重点包括房间净面积、窗口前操作净距、窗口间距等内容；依据《综合医院建筑设计规范》GB 51039-2014；《医疗机构感染预防与控制基本准则》GB/T 39498-2020复核规范要求，并结合儿童医院陪护、感控、净距和设备接口进行优化。",
    "assets": [
      "docs/materials/门诊/门诊平面_t3.dwg"
    ],
    "rules": [
      "area",
      "handwash",
      "privacy",
      "child"
    ],
    "siteModel": "models/viewer.html?scene=opd-registration",
    "siteModelName": "3D交互信息模型（收费挂号室·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "收费挂号室审图重点包括房间净面积、窗口前操作净距、窗口间距等内容；依据《综合医院建筑设计规范》GB 51039-2014；《医疗机构感染预防与控制基本准则》GB/T 39498-2020复核规范要求，并结合儿童医院陪护、感控、净距和设备接口进行优化。",
    "docFacts": [
      "房间净面积：净面积≥10㎡",
      "窗口前操作净距：窗口前操作净距≥1.2m",
      "窗口间距：窗口间距≥1.2m",
      "手卫生设施：服务窗口附近应设置手卫生设施",
      "医疗废物收集点：服务区域应设置分类医疗废物收集容器"
    ],
    "docReview": [
      "空间模数与净空 / 房间净面积：净面积≥12㎡，预留服务与等候空间",
      "空间模数与净空 / 窗口前操作净距：窗口前操作净距≥1.5m，便于轮椅停靠",
      "空间模数与净空 / 窗口间距：窗口间距≥1.5m，避免排队拥挤",
      "感控要求与设施 / 手卫生设施：窗口旁设置非接触式手消设施，便于工作人员使用",
      "感控要求与设施 / 医疗废物收集点：设置带盖分类垃圾桶，便于票据等废弃物收集"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "房间净面积",
        "requirement": "净面积≥10㎡",
        "source": "《综合医院建筑设计规范》GB 51039-2014",
        "suggestion": "净面积≥12㎡，预留服务与等候空间"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "窗口前操作净距",
        "requirement": "窗口前操作净距≥1.2m",
        "source": "《综合医院建筑设计规范》GB 51039-2014",
        "suggestion": "窗口前操作净距≥1.5m，便于轮椅停靠"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "窗口间距",
        "requirement": "窗口间距≥1.2m",
        "source": "《综合医院建筑设计规范》GB 51039-2014",
        "suggestion": "窗口间距≥1.5m，避免排队拥挤"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "手卫生设施",
        "requirement": "服务窗口附近应设置手卫生设施",
        "source": "《医疗机构感染预防与控制基本准则》GB/T 39498-2020",
        "suggestion": "窗口旁设置非接触式手消设施，便于工作人员使用"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "医疗废物收集点",
        "requirement": "服务区域应设置分类医疗废物收集容器",
        "source": "《医疗机构感染预防与控制基本准则》GB/T 39498-2020",
        "suggestion": "设置带盖分类垃圾桶，便于票据等废弃物收集"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "高频接触面耐消毒",
        "requirement": "窗口台面等高频接触面应采用耐消毒材料",
        "source": "《医疗机构感染预防与控制基本准则》GB/T 39498-2020",
        "suggestion": "窗口台面采用抗菌材料，便于擦拭消毒"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "地面防滑等级",
        "requirement": "地面防滑等级≥R10",
        "source": "《儿童医院建设标准》建标174-2016",
        "suggestion": "采用同质透心防滑PVC地板，防滑等级≥R11"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "阳角圆弧处理",
        "requirement": "儿童可触及部位阳角应做成圆弧",
        "source": "《儿童医院建设标准》建标174-2016",
        "suggestion": "所有阳角R≥20mm，避免磕碰伤害"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "窗口防撞处理",
        "requirement": "窗口玻璃应设置防撞处理",
        "source": "《儿童医院建设标准》建标174-2016",
        "suggestion": "窗口玻璃设置防撞条，避免儿童碰撞"
      },
      {
        "dimension": "安全出口与疏散门",
        "focus": "疏散门开启方向",
        "requirement": "疏散门应向疏散方向开启",
        "source": "《建筑设计防火规范》GB 50016-2014（2018版）",
        "suggestion": "采用自闭式门体，平时保持关闭状态"
      },
      {
        "dimension": "安全出口与疏散门",
        "focus": "疏散门净宽",
        "requirement": "疏散门净宽≥0.9m",
        "source": "《建筑设计防火规范》GB 50016-2014（2018版）",
        "suggestion": "采用子母门，净宽≥1.1m，便于轮椅与人员疏散"
      },
      {
        "dimension": "安全出口与疏散门",
        "focus": "疏散路径",
        "requirement": "房间内最远点至门的距离≤15m",
        "source": "《建筑设计防火规范》GB 50016-2014（2018版）",
        "suggestion": "服务台布置不遮挡疏散路径，门后1.4m无障碍物"
      },
      {
        "dimension": "装修材料与防火",
        "focus": "室内装修材料燃烧性能",
        "requirement": "医疗建筑室内装修材料燃烧性能≥B1级",
        "source": "《建筑设计防火规范》GB 50016-2014（2018版）",
        "suggestion": "顶棚、墙面、地面采用A级不燃材料"
      },
      {
        "dimension": "装修材料与防火",
        "focus": "排烟设施",
        "requirement": "无自然排烟条件时应设置机械排烟",
        "source": "《建筑设计防火规范》GB 50016-2014（2018版）",
        "suggestion": "配置独立机械排烟，排风量≥60m³/h"
      },
      {
        "dimension": "装修材料与防火",
        "focus": "应急照明",
        "requirement": "疏散照明地面照度≥1.0lx，持续供电≥0.5h",
        "source": "《建筑设计防火规范》GB 50016-2014（2018版）",
        "suggestion": "应急照明覆盖窗口与操作区，无照明死角"
      }
    ],
    "preview": "assets/img/previews/opd_registration.jpg",
    "sceneInfo": {
      "thumb": "assets/img/scene-thumbs/opd-registration.jpg",
      "area": "4.80 × 6.00 m · 净高 3.0m（≈28.8㎡，推测补全）",
      "dims": {
        "def": [
          4.8,
          6,
          3
        ],
        "min": [
          3.6,
          4.8,
          2.7
        ],
        "sugg": [
          4.8,
          6,
          3
        ],
        "minLabel": "docFacts 最低",
        "suggLabel": "图则建议"
      },
      "stats": {
        "furn": 11,
        "markers": 9
      },
      "cost": "约 3.2–12.6 万元"
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 9,
      "priority": "P3",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 11,
      "finalStatus": "已完成",
      "finalRequirement": "为两名收费人员补 supportId/workTarget 绑定。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "opd_single",
    "dept": "门诊",
    "name": "单人诊室",
    "type": "clinic",
    "priority": "P1",
    "summary": "单人诊室审图重点包括房间净面积、诊查床侧净距、门洞口净宽等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.2.4条第1款、第5.1.9条第1款；《综合医院建筑设计标准》GB 51039-2014 第3.2.6条第2款复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/门诊/轴测/单人诊室.png",
      "docs/materials/2026.7.6/门诊/轴测/单人诊室(双门).png",
      "docs/materials/2026.7.6/门诊/CAD/门诊平面_t3.dwg",
      "docs/materials/2026.7.6/门诊/模型/门诊平面.skp"
    ],
    "preview": "assets/img/previews/opd_single.jpg",
    "rules": [
      "area",
      "handwash",
      "privacy",
      "child"
    ],
    "siteModel": "models/viewer.html?scene=opd-single",
    "siteModelName": "3D交互信息模型（单人诊室·新版）",
    "legacySiteModel": "models/site/model-clinic.html",
    "docBrief": "单人诊室审图重点包括房间净面积、诊查床侧净距、门洞口净宽等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.2.4条第1款、第5.1.9条第1款；《综合医院建筑设计标准》GB 51039-2014 第3.2.6条第2款复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "房间净面积：单人诊查室的使用面积不应小于8.00㎡。诊查室的室内净高不宜低于2.60m。",
      "诊查床侧净距：各个功能用房空间尺寸应符合医疗操作规范和防护等相关要求，合理测算医疗行为空间尺度。",
      "门洞口净宽：诊室门净宽不应小于0.90m。",
      "装修材料性能：医疗建筑内的诊疗室，其内部装修材料的燃烧性能均应为A级（顶棚、墙面）和不低于B1级（地面）。",
      "排烟设施：建筑的疏散走道、人员密集的场所应依法设置防烟与排烟设施。",
      "疏散门方向：民用建筑内各房间疏散门的开启方向：应向疏散方向开启。"
    ],
    "docBehaviors": [
      "医生近门核对信息、询问病史并安抚患儿",
      "患儿在诊查床接受听诊、触诊和发育评估",
      "医护诊疗前后使用感应洗手池完成手消毒",
      "移动工作站或壁挂电脑完成病历、处方和检查申请"
    ],
    "docReview": [
      "空间模数与净空 / 房间净面积：考虑儿童“一患多陪”及童车平车周转，图纸净面积优化为≥10.0㎡（采用4200mm或8400mm模数柱网），内部预留直观的≥1.2m×1.2m无障碍回转边界。",
      "空间模数与净空 / 诊查床侧净距：审图中要求诊查桌与诊查床连体布置，去除移动推车。诊查床外侧（操作面）靠走道预留净宽≥0.9m的医护/家长复合操作通道。",
      "空间模数与净空 / 门洞口净宽：修正： 淘汰原表子母门（易产生防夹手死角且不便儿童防护），统一优化为1000mm宽单扇平开木门（带闭门器，边角防夹手圆弧）。",
      "建筑防火与疏散 / 装修材料性能：图纸技术说明中明示：顶棚、墙面均采用A级不燃材料，地面采用不低于B1级（如不燃/阻燃PVC）。",
      "建筑防火与疏散 / 排烟设施：无自然通风条件时，诊室必须规划吊顶内机械排烟风管点位，保障其独立防烟性能。",
      "建筑防火与疏散 / 疏散门方向：平面图纸中诊室平开门必须向疏散走廊方向开启。",
      "建筑防火与疏散 / 疏散门净宽：确保诊室门开启后不应减少走廊的有效疏散净宽（走廊单侧候诊需维持≥2.4m，两侧≥3.0m）。",
      "室内装修与防护 / 地面防滑：2D平面图纸中设计无缝同质透心PVC地板，防滑等级严格执行≥R11，不画任何背景分格网格线。"
    ],
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "房间净面积",
        "requirement": "单人诊查室的使用面积不应小于8.00㎡。诊查室的室内净高不宜低于2.60m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.2.4条第1款、第5.1.9条第1款",
        "suggestion": "考虑儿童“一患多陪”及童车平车周转，图纸净面积优化为≥10.0㎡（采用4200mm或8400mm模数柱网），内部预留直观的≥1.2m×1.2m无障碍回转边界。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "诊查床侧净距",
        "requirement": "各个功能用房空间尺寸应符合医疗操作规范和防护等相关要求，合理测算医疗行为空间尺度。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第3.2.6条第2款",
        "suggestion": "审图中要求诊查桌与诊查床连体布置，去除移动推车。诊查床外侧（操作面）靠走道预留净宽≥0.9m的医护/家长复合操作通道。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "门洞口净宽",
        "requirement": "诊室门净宽不应小于0.90m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.2.4条第4款",
        "suggestion": "修正： 淘汰原表子母门（易产生防夹手死角且不便儿童防护），统一优化为1000mm宽单扇平开木门（带闭门器，边角防夹手圆弧）。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "装修材料性能",
        "requirement": "医疗建筑内的诊疗室，其内部装修材料的燃烧性能均应为A级（顶棚、墙面）和不低于B1级（地面）。",
        "source": "《建筑防火通用规范》GB 55037-2022 第6.5.6条",
        "suggestion": "图纸技术说明中明示：顶棚、墙面均采用A级不燃材料，地面采用不低于B1级（如不燃/阻燃PVC）。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "排烟设施",
        "requirement": "建筑的疏散走道、人员密集的场所应依法设置防烟与排烟设施。",
        "source": "《建筑防火通用规范》GB 55037-2022 第8.2.1条",
        "suggestion": "无自然通风条件时，诊室必须规划吊顶内机械排烟风管点位，保障其独立防烟性能。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "疏散门方向",
        "requirement": "民用建筑内各房间疏散门的开启方向：应向疏散方向开启。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.4条",
        "suggestion": "平面图纸中诊室平开门必须向疏散走廊方向开启。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "疏散门净宽",
        "requirement": "疏散走道、疏散门的净宽度均不应小于1.1m（注：此处指公共通道，诊室单扇门通行宽度执行医疗工艺1.0m标准）。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.4条第3款",
        "suggestion": "确保诊室门开启后不应减少走廊的有效疏散净宽（走廊单侧候诊需维持≥2.4m，两侧≥3.0m）。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "地面防滑",
        "requirement": "地面应选用防滑、易清洗的材料。",
        "source": "《综合医院建设标准》第三十九条第四款",
        "suggestion": "2D平面图纸中设计无缝同质透心PVC地板，防滑等级严格执行≥R11，不画任何背景分格网格线。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "阳角圆弧",
        "requirement": "儿童诊疗区域的门窗、家具和楼地面等应采取必要的安全保护措施。",
        "source": "《综合医院建设标准》第三十九条第七款",
        "suggestion": "室内所有固定家具体、墙体阳角物理上做R≥20mm的圆弧或软包覆，全面消除尖锐棱角。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "防污墙裙",
        "requirement": "内墙墙体不应使用不耐碰撞、不易吊挂的材料。",
        "source": "《综合医院建设标准》第三十九条第三款",
        "suggestion": "诊室内部100%设置1.5m高抗菌防污一体化墙裙（或抗菌树脂板），耐受耐酸碱消毒剂高频擦洗。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "手卫生设施",
        "requirement": "诊室、检验科等房间的洗手盆应采用非手动开关，并应采取防止污水外溅的措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第6.2.5条第4款",
        "suggestion": "诊室入口处刚性配置非接触式感应洗手盆（诊疗前后无绕行），水嘴出水弧度与盆体需做针对儿童防喷溅凹陷的工艺深化。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "高频接触面",
        "requirement": "阳角及高频接触面应易清洁消毒。台面均应采用易洁净、耐腐蚀、可冲洗的面层。",
        "source": "《综合医院建设标准》第三十九条第六款",
        "suggestion": "采用整体抗菌无缝实体面材台面。所有中文简体粗体标签（如：洗手盆、诊查床）一律100%内置于家具几何线框内，取消外引线。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "医疗废物收集",
        "requirement": "医疗业务用房应符合医院感染预防与控制的基本原则，易于冲洗、消毒。",
        "source": "《儿童医院建设标准》建标174-2016 第三十四条",
        "suggestion": "诊室尽端隐蔽处设置独立有盖医疗废物收集容器点位，严禁摆放在公共视线与儿童易触碰区域。"
      }
    ],
    "glbModel": "glb/opd-single.glb",
    "glbModelName": "实景模型（SketchUp 导出）",
    "sceneInfo": {
      "thumb": "assets/img/scene-thumbs/opd-single.jpg",
      "area": "3.0 × 4.8 m · 净高 2.9m（≈14.4㎡，可参数化）",
      "dims": {
        "def": [
          3,
          4.8,
          2.9
        ],
        "min": [
          2.8,
          4.6,
          2.7
        ],
        "sugg": [
          3.3,
          5.1,
          3
        ],
        "minLabel": "GB 51039 最低",
        "suggLabel": "图则建议"
      },
      "stats": {
        "furn": 13,
        "markers": 10
      },
      "cost": "约 0.6–3.1 万元"
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 2,
      "priority": "P1",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 4,
      "finalStatus": "部分完成",
      "finalRequirement": "锐器盒移至洗手/治疗车侧并避开门区；保存修正后的诊桌；检查灯增加停泊与工作状态。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）",
    "glbModelDisabled": true,
    "glbModelDisabledReason": "2026-07-13 GLB 包围核查发现尺度、原点或游离构件异常；程序场景保留，清理并统一米制重导前禁用实景切换。",
    "glbAuditStatus": "隔离待重导"
  },
  {
    "id": "opd_special",
    "dept": "门诊",
    "name": "特需诊室",
    "type": "clinic",
    "priority": "P2",
    "summary": "特需诊室审图重点包括房间净面积、诊疗陪护净距、诊查床侧净距等内容；依据《综合医院建筑设计标准》GB 51039-2014 第3.2.6条、第5.1.9条；《综合医院建设标准》第五条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/门诊/行为示意图/特需诊室.png",
      "docs/materials/2026.7.6/门诊/轴测/特需诊室.png",
      "docs/materials/2026.7.6/门诊/CAD/门诊平面_t3.dwg"
    ],
    "rules": [
      "area",
      "handwash",
      "privacy",
      "child"
    ],
    "siteModel": "models/viewer.html?scene=opd-special",
    "siteModelName": "3D交互信息模型（特需诊室·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "特需诊室审图重点包括房间净面积、诊疗陪护净距、诊查床侧净距等内容；依据《综合医院建筑设计标准》GB 51039-2014 第3.2.6条、第5.1.9条；《综合医院建设标准》第五条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "房间净面积：各个功能用房空间尺寸应符合医疗操作规范。诊查室的室内净高不宜低于2.60m。",
      "诊疗陪护净距：建筑应充分考虑使用人群的生理特点及心理，合理组织空间尺度。",
      "诊查床侧净距：医疗业务用房设计应合理测算医疗行为及设备工位空间尺度。",
      "门洞口净宽：诊室门净宽不应小于0.90m。",
      "地面防滑：地面应选用防滑、易清洗的材料。",
      "阳角圆弧：儿童诊疗区域的门窗、家具和楼地面等应采取必要的安全保护措施。"
    ],
    "docReview": [
      "空间模数与净空 / 房间净面积：基于模块化柱网模块设计，图纸净面积优化为≥18.0㎡（建议4200mm×4500mm或以上）。2D图面上需明确划定诊疗区与高端家属陪护区的软质空间分隔界线。",
      "空间模数与净空 / 诊疗陪护净距：诊疗核心区与家属陪护椅之间活动净距≥1.5m。不设置多余吊顶投影或背景网格，维持空间的纯净与高开敞感。",
      "空间模数与净空 / 诊查床侧净距：诊查桌与诊查床连体化无缝设计，取消移动推车。诊查床外侧操作通道净宽优化为**≥1.0m**，保障医生、护士操作与家属陪护同时站位。",
      "空间模数与净空 / 门洞口净宽：修正： 淘汰原表中易产生防夹手死角的子母门。优化为1100mm宽单扇平开高端医疗木门（配静音自闭装置与圆边防防夹手护条），保障轮椅、童车平滑通行。",
      "室内装修与防护 / 地面防滑：2D平面图纸中设计无缝同质透心吸音防滑PVC地板，防滑等级严格执行≥R11，不画任何背景地砖网格线。",
      "室内装修与防护 / 阳角圆弧：室内所有固定家具体、装饰墙体、隔断阳角物理上做R≥20mm的圆弧或软包覆，全面消除尖锐棱角。",
      "室内装修与防护 / 墙面防撞软包：诊室墙面1.2m以下高频触及区设置B1级阻燃防撞软包，面层需耐受高浓度医用消毒剂擦洗。",
      "建筑防火与疏散 / 装修材料性能：图纸技术说明中明示：顶棚、墙面均采用A级不燃材料，地面与防撞软包、家属沙发等内部软装不低于B1级阻燃。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "房间净面积",
        "requirement": "各个功能用房空间尺寸应符合医疗操作规范。诊查室的室内净高不宜低于2.60m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第3.2.6条、第5.1.9条",
        "suggestion": "基于模块化柱网模块设计，图纸净面积优化为≥18.0㎡（建议4200mm×4500mm或以上）。2D图面上需明确划定诊疗区与高端家属陪护区的软质空间分隔界线。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "诊疗陪护净距",
        "requirement": "建筑应充分考虑使用人群的生理特点及心理，合理组织空间尺度。",
        "source": "《综合医院建设标准》第五条",
        "suggestion": "诊疗核心区与家属陪护椅之间活动净距≥1.5m。不设置多余吊顶投影或背景网格，维持空间的纯净与高开敞感。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "诊查床侧净距",
        "requirement": "医疗业务用房设计应合理测算医疗行为及设备工位空间尺度。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第3.2.6条第2款",
        "suggestion": "诊查桌与诊查床连体化无缝设计，取消移动推车。诊查床外侧操作通道净宽优化为**≥1.0m**，保障医生、护士操作与家属陪护同时站位。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "门洞口净宽",
        "requirement": "诊室门净宽不应小于0.90m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.2.4条第4款",
        "suggestion": "修正： 淘汰原表中易产生防夹手死角的子母门。优化为1100mm宽单扇平开高端医疗木门（配静音自闭装置与圆边防防夹手护条），保障轮椅、童车平滑通行。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "地面防滑",
        "requirement": "地面应选用防滑、易清洗的材料。",
        "source": "《综合医院建设标准》第三十九条 Fourth款",
        "suggestion": "2D平面图纸中设计无缝同质透心吸音防滑PVC地板，防滑等级严格执行≥R11，不画任何背景地砖网格线。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "阳角圆弧",
        "requirement": "儿童诊疗区域的门窗、家具和楼地面等应采取必要的安全保护措施。",
        "source": "《综合医院建设标准》第三十九条第七款",
        "suggestion": "室内所有固定家具体、装饰墙体、隔断阳角物理上做R≥20mm的圆弧或软包覆，全面消除尖锐棱角。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "墙面防撞软包",
        "requirement": "内墙墙体不应使用易裂、易燃、不耐碰撞的材料。",
        "source": "《综合医院建设标准》第三十九条第三款",
        "suggestion": "诊室墙面1.2m以下高频触及区设置B1级阻燃防撞软包，面层需耐受高浓度医用消毒剂擦洗。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "装修材料性能",
        "requirement": "医疗建筑内的诊疗室，其内部装修材料的燃烧性能均应为A级（顶棚、墙面）和不低于B1级（地面）。",
        "source": "《建筑防火通用规范》GB 55037-2022 第6.5.6条",
        "suggestion": "图纸技术说明中明示：顶棚、墙面均采用A级不燃材料，地面与防撞软包、家属沙发等内部软装不低于B1级阻燃。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "排烟设施",
        "requirement": "建筑的疏散走道、人员密集的场所应依法设置防烟与排烟设施。",
        "source": "《建筑防火通用规范》GB 55037-2022 第8.2.1条",
        "suggestion": "无自然通风条件时，诊室吊顶内必须规划机械排烟风管点位，排风量≥80m³/h，保障独立防烟性能。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "疏散门方向",
        "requirement": "民用建筑内各房间疏散门的开启方向：应向疏散方向开启。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.4条",
        "suggestion": "平面图纸中特需诊室平开门必须向疏散走廊方向开启（顺疏散方向）。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "疏散门净宽",
        "requirement": "疏散走道、疏散门的净宽度均不应小于1.1m。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.4条第3款",
        "suggestion": "确保诊室门开启后不应减少走廊的有效疏散净宽（走廊单侧候诊需维持≥2.4m，两侧≥3.0m）。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "诊疗区手卫生",
        "requirement": "诊室、检验科等房间的洗手盆应采用非手动开关，并应采取防止污水外溅的措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第6.2.5条第4款",
        "suggestion": "诊室入口处刚性配置一体化非接触式感应洗手盆（流线无绕行）。台面与盆体结构做凹陷防喷溅设计，避免水渍外溅。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "高频接触耐消毒",
        "requirement": "阳角及高频接触面应易清洁消毒。台面均应采用易洁净、耐腐蚀、可冲洗的面层。",
        "source": "《综合医院建设标准》第三十九条第六款、第五款",
        "suggestion": "采用抗菌无缝整体实体面材台面。中文简体粗体标签（如：洗手盆、诊查床）一律100%内置于线框内，取消一切外引线。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "医疗废物收集",
        "requirement": "医疗业务用房应符合医院感染预防与控制的基本原则，废弃物应封闭处理。",
        "source": "《儿童医院建设标准》建标174-2016 第三十四条",
        "suggestion": "诊室诊疗区尽端隐蔽处设置专属有盖医疗废物收集容器点位，与家属陪护活动流线完全隔离。"
      }
    ],
    "preview": "assets/img/previews/opd_special.jpg",
    "glbModel": "glb/opd-special.glb",
    "glbModelDisabled": true,
    "glbModelStatus": "逐房间复核标记为尺度/游离构件异常，待重新归零导出后启用",
    "sceneInfo": {
      "thumb": "assets/img/scene-thumbs/opd-special.jpg",
      "area": "4.50 × 6.00 m · 净高 2.80m（≈27.0㎡，可参数化）",
      "dims": {
        "def": [
          4.5,
          6,
          2.8
        ],
        "min": [
          3.5,
          4.3,
          2.7
        ],
        "sugg": [
          4.9,
          6.5,
          2.9
        ],
        "minLabel": "GB 51039 最低",
        "suggLabel": "图则建议"
      },
      "stats": {
        "furn": 12,
        "markers": 8
      },
      "cost": "约 1.0–4.0 万元"
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 11,
      "priority": "P2",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 13,
      "finalStatus": "部分完成",
      "finalRequirement": "问题 GLB 重导出前保持禁用。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）",
    "glbModelDisabledReason": "2026-07-13 GLB 包围核查发现尺度、原点或游离构件异常；程序场景保留，清理并统一米制重导前禁用实景切换。",
    "glbAuditStatus": "隔离待重导"
  },
  {
    "id": "opd_teaching",
    "dept": "门诊",
    "name": "带教诊室",
    "type": "clinic",
    "priority": "P1",
    "summary": "带教诊室审图重点包括房间净面积、诊疗观摩净距、诊查床侧净距等内容；依据《综合医院建筑设计标准》GB 51039-2014 第3.2.6条、第5.1.9条；《儿童医院建设标准》建标174-2016 第三十二条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/门诊/轴测/带教诊室.png",
      "docs/materials/2026.7.6/门诊/CAD/门诊平面_t3.dwg"
    ],
    "preview": "assets/img/previews/opd_teaching.jpg",
    "rules": [
      "area",
      "handwash",
      "privacy",
      "child"
    ],
    "siteModel": "models/viewer.html?scene=opd-teaching",
    "siteModelName": "3D交互信息模型（带教诊室·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "带教诊室审图重点包括房间净面积、诊疗观摩净距、诊查床侧净距等内容；依据《综合医院建筑设计标准》GB 51039-2014 第3.2.6条、第5.1.9条；《儿童医院建设标准》建标174-2016 第三十二条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "房间净面积：诊查室的室内净高不宜低于2.60m。",
      "诊疗观摩净距：建筑应符合现行国家标准《无障碍设计规范》GB 50763的有关规定。",
      "诊查床侧净距：医疗业务用房设计应合理测算医疗行为及设备工位空间尺度。",
      "门洞口净宽：诊室门净宽不应小于0.90m。",
      "地面防滑：地面应选用防滑、易清洗的材料。",
      "阳角圆弧：儿童诊疗区域的门窗、家具和楼地面等应采取必要保护措施。"
    ],
    "docReview": [
      "空间模数与净空 / 房间净面积：图纸净面积优化为≥20.0㎡，严格在2D平面中划定教学观摩区与核心诊疗区的物理分界线。",
      "空间模数与净空 / 诊疗观摩净距：诊疗核心与教学观摩区净距≥2.0m。中间设置不落地、不燃材料单向透视玻璃，图面取消任何透视投影及阴影。",
      "空间模数与净空 / 诊查床侧净距：诊查桌与诊查床连体布置，去除移动手推车。诊查床外侧操作通道净宽优化为≥1.2m，满足导师、学员、家长多方站位与抱婴操作。",
      "空间模数与净空 / 门洞口净宽：修正： 淘汰传统双开门或子母门（对儿童易产生防夹手死角且降低气密密封性），统一优化为1100mm宽单扇平开医疗木门（配闭门器与防夹手圆边）。",
      "室内装修与防护 / 地面防滑：2D平面图纸中设计无缝同质透心PVC地板，防滑等级严格执行≥R11，不画任何背景分格网格线。",
      "室内装修与防护 / 阳角圆弧：房间内及玻璃隔断框体所有固定构件、墙体阳角物理上做R≥20mm的圆弧或软包覆，全面消除尖锐棱角。",
      "室内装修与防护 / 观摩座椅防护：教学观摩区采用一体化固定式连排圆角阻燃座椅（不设移动椅以防撞击跌落），面层需耐受耐酸碱消毒剂高频擦洗。",
      "建筑防火与疏散 / 装修材料性能：图纸技术说明中明示：顶棚、墙面均采用A级不燃材料，地面及固定教学座椅材料不低于B1级。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "房间净面积",
        "requirement": "诊查室的室内净高不宜低于2.60m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第3.2.6条、第5.1.9条",
        "suggestion": "图纸净面积优化为≥20.0㎡，严格在2D平面中划定教学观摩区与核心诊疗区的物理分界线。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "诊疗观摩净距",
        "requirement": "建筑应符合现行国家标准《无障碍设计规范》GB 50763的有关规定。",
        "source": "《儿童医院建设标准》建标174-2016 第三十二条",
        "suggestion": "诊疗核心与教学观摩区净距≥2.0m。中间设置不落地、不燃材料单向透视玻璃，图面取消任何透视投影及阴影。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "诊查床侧净距",
        "requirement": "医疗业务用房设计应合理测算医疗行为及设备工位空间尺度。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第3.2.6条第2款",
        "suggestion": "诊查桌与诊查床连体布置，去除移动手推车。诊查床外侧操作通道净宽优化为≥1.2m，满足导师、学员、家长多方站位与抱婴操作。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "门洞口净宽",
        "requirement": "诊室门净宽不应小于0.90m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.2.4条第4款",
        "suggestion": "修正： 淘汰传统双开门或子母门（对儿童易产生防夹手死角且降低气密密封性），统一优化为1100mm宽单扇平开医疗木门（配闭门器与防夹手圆边）。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "地面防滑",
        "requirement": "地面应选用防滑、易清洗的材料。",
        "source": "《综合医院建设标准》 第三十九条第四款",
        "suggestion": "2D平面图纸中设计无缝同质透心PVC地板，防滑等级严格执行≥R11，不画任何背景分格网格线。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "阳角圆弧",
        "requirement": "儿童诊疗区域的门窗、家具和楼地面等应采取必要保护措施。",
        "source": "《综合医院建设标准》 第三十九条第七款",
        "suggestion": "房间内及玻璃隔断框体所有固定构件、墙体阳角物理上做R≥20mm的圆弧或软包覆，全面消除尖锐棱角。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "观摩座椅防护",
        "requirement": "内墙墙体不应使用易裂、易燃、不耐碰撞的材料。",
        "source": "《综合医院建设标准》 第三十九条第三款",
        "suggestion": "教学观摩区采用一体化固定式连排圆角阻燃座椅（不设移动椅以防撞击跌落），面层需耐受耐酸碱消毒剂高频擦洗。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "装修材料性能",
        "requirement": "医疗建筑内的诊疗室，其内部装修材料的燃烧性能均应为A级（顶棚、墙面）和不低于B1级（地面）。",
        "source": "《建筑防火通用规范》GB 55037-2022 第6.5.6条",
        "suggestion": "图纸技术说明中明示：顶棚、墙面均采用A级不燃材料，地面及固定教学座椅材料不低于B1级。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "排烟设施",
        "requirement": "建筑的疏散走道、人员密集的场所应依法设置防烟与排烟设施。",
        "source": "《建筑防火通用规范》GB 55037-2022 第8.2.1条",
        "suggestion": "无自然通风条件时，诊室及观摩区上方必须规划吊顶内机械排烟风管点位，总排风量≥100m³/h，保障独立防烟性能。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "应急照明",
        "requirement": "医疗建筑消防应急照明备用电源连续供电时间不应小于1.0h。人员密集场所地面最低水平照度不应低于3.0lx。",
        "source": "《建筑防火通用规范》GB 55037-2022 第10.1.4条、第10.1.10条 （核心强条修正）",
        "suggestion": "强条刚性修正： 彻底废除原表中过时的“0.5h/1.0lx”参数。审图中单人诊室应急照明地面照度刚性执行≥3.0lx，系统连续供电时间刚性执行≥60分钟。采用柔光型灯具。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "疏散门方向",
        "requirement": "民用建筑内各房间疏散门的开启方向：应向疏散方向开启。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.4条",
        "suggestion": "平面图纸中诊室平开门必须向疏散走廊方向开启（顺疏散方向）。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "疏散门净宽",
        "requirement": "疏散走道、疏散门的净宽度均不应小于1.1m（注：此处指公共通道，带教诊室门执行医疗工艺1.1m单扇门标准）。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.4条第3款",
        "suggestion": "确保诊室门开启后不应减少走廊的有效疏散净宽（走廊单侧候诊需维持≥2.4m，两侧≥3.0m）。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "诊疗区手卫生",
        "requirement": "诊室、检验科等房间的洗手盆应采用非手动开关，并应采取防止污水外溅的措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第6.2.5条第4款",
        "suggestion": "诊室入口或核心诊疗区直通线上刚性配置非接触式感应洗手盆（诊疗前后无绕行），盆体做防喷溅工艺深化，避免幼儿溅水。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "观摩交叉防护",
        "requirement": "医疗业务用房应符合医院感染预防与控制的基本原则。",
        "source": "《儿童医院建设标准》建标174-2016 第三十四条",
        "suggestion": "观摩区与诊疗区设置单向透视防碎安全玻璃隔断。明确区分区域，中文简体粗体标签（如：洗手盆、诊查床）一律100%内置于线框内。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "医疗废物收集",
        "requirement": "医疗业务用房应易于冲洗、消毒，废弃物应封闭处理。",
        "source": "《儿童医院建设标准》建标174-2016 第三十四条",
        "suggestion": "诊室诊疗单元尽端隐蔽处设置独立有盖医疗废物收集容器点位，与教学观摩人流流线完全不交叉。"
      }
    ],
    "glbModel": "glb/opd-teaching.glb",
    "sceneInfo": {
      "thumb": "assets/img/scene-thumbs/opd-teaching.jpg",
      "area": "4.20 × 5.40 m · 净高 2.80m（≈22.7㎡，可参数化）",
      "dims": {
        "def": [
          4.2,
          5.4,
          2.8
        ],
        "min": [
          3.8,
          4.75,
          2.7
        ],
        "sugg": [
          4.6,
          5.9,
          2.9
        ],
        "minLabel": "建标174 最低",
        "suggLabel": "图则建议"
      },
      "stats": {
        "furn": 15,
        "markers": 8
      },
      "cost": "约 2.3–10.4 万元"
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 1,
      "priority": "P1",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 3,
      "finalStatus": "部分完成",
      "finalRequirement": "移出门区学生座椅；监护设备回到床旁；无独立观察室时取消单向观察玻璃或改教学屏。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）",
    "glbModelDisabled": true,
    "glbModelDisabledReason": "2026-07-13 GLB 包围核查发现尺度、原点或游离构件异常；程序场景保留，清理并统一米制重导前禁用实景切换。",
    "glbAuditStatus": "隔离待重导"
  },
  {
    "id": "opd_floor_glb",
    "dept": "门诊",
    "name": "门诊完整科室平面（3D信息模型）",
    "type": "floor",
    "priority": "P1",
    "summary": "参考代表性完整门诊平面与本项目门诊数据库，按“入口预检分诊—医疗街—一级候诊—二次候诊—诊室组团—治疗/药房离院—医护后场/污物流线”搭建的整层级医疗工艺信息模型；用于替代单一空壳/GLB外观模型，重点表达科室组织、流线分离、儿童候诊与无障碍校核。",
    "assets": [
      "docs/materials/2026.7.6/门诊/CAD/门诊平面_t3.dwg",
      "docs/materials/2026.7.6/门诊/模型/门诊平面.skp"
    ],
    "preview": "",
    "rules": [
      "area",
      "child",
      "accessible"
    ],
    "glbModel": "glb/outpatient-floor.glb",
    "glbModelDisabled": true,
    "glbModelStatus": "逐房间复核标记为尺度/游离构件异常，待重新归零导出后启用",
    "siteModelName": "3D交互信息模型（门诊完整科室平面·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docReviewRows": [
      {
        "dimension": "空间尺度",
        "focus": "功能区面积配比",
        "requirement": "儿科候诊区面积应按不小于2㎡/人设计。母婴室应设置独立房间且使用面积不应低于10.0㎡。",
        "source": "《综合医院建筑设计标准》 第5.2.6条、第5.1.15条",
        "suggestion": "候诊区指标严格执行≥2.0㎡/人。双人或带特殊检查功能的诊室使用面积优化为≥12.0㎡（契合模块化网格布局）。"
      },
      {
        "dimension": "空间尺度",
        "focus": "房间短边净宽",
        "requirement": "双人诊查室的开间净尺寸不应小于3.00m，单人诊查室不应小于2.50m。诊查室室内净高不宜低于2.60m。",
        "source": "《综合医院建筑设计标准》 第5.2.4条、第5.1.9条",
        "suggestion": "诊室短边（开间）净宽统一优化为≥3.00m。诊室通行木门规格标准化：统一采用1000mm宽单扇平开门。"
      },
      {
        "dimension": "空间尺度",
        "focus": "操作空间预留",
        "requirement": "各个功能用房空间尺寸应符合医疗操作规范和防护等相关要求，包括医疗行为空间尺度。",
        "source": "《综合医院建筑设计标准》 第3.2.6条",
        "suggestion": "诊查桌与检查床一体化连体布置，取消不必要的移动手推车。检查床侧边预留操作通道净宽≥0.90m。"
      },
      {
        "dimension": "空间尺度",
        "focus": "服务点位尺度",
        "requirement": "候诊区附近宜设置儿童活动区，墙体与地面应为软质材料。儿科区域宜设置母婴室。",
        "source": "《综合医院建筑设计标准》 第5.2.6条",
        "suggestion": "诊区内规划“就诊-游戏-家长休息”综合岛。儿童活动角净面积≥8.0㎡，界面采用无阴影软质包覆。"
      },
      {
        "dimension": "流线效率",
        "focus": "诊疗动线闭环性",
        "requirement": "门诊部流线应科学、合理并符合感染控制要求。预检分诊功能与设施应设于门诊入口处附近。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.2.1条、第5.2.2A条",
        "suggestion": "组织“预检-分诊-专科候诊-诊室-离院”单向流线。跨区动线限制在20m内。"
      },
      {
        "dimension": "流线效率",
        "focus": "医患/洁污流线",
        "requirement": "洁污、医患、人车等流线组织清晰，避免交叉。利用走道单侧候诊时，走道净宽不小于2.40m，双侧不小于3.00m。",
        "source": "《儿童医院建设标准》建标174-2016 第二十三条；《综合医院建筑设计标准》 第5.2.3条",
        "suggestion": "严格实行医护双通道布局。次通道（诊区走廊）单侧候诊净宽设计为2.40m，衔接转角处预留≥1.5㎡的童车/亲子缓冲空间。"
      },
      {
        "dimension": "流线效率",
        "focus": "专科动线独立性",
        "requirement": "门诊科室应独立成区，宜采用模块化、尽端式布局。不同诊疗单元之间不宜穿越。",
        "source": "《综合医院建筑设计标准》 第5.2.3A条",
        "suggestion": "特殊门诊（口腔科、发热筛查等）采用尽端式独立分区。"
      },
      {
        "dimension": "流线效率",
        "focus": "通行适配性",
        "requirement": "建筑应符合无障碍设计规范。公共走道室内净高不低于2.30m。走廊距地0.6m处宜加设幼儿专用扶手。",
        "source": "《儿童医院建设标准》 第三十二条；《综合医院建筑设计标准》 第5.1.9条",
        "suggestion": "设置高低位双层扶手（0.6m及0.9m）。导视全图形化，中文标签粗体100%内置于房间几何框内。"
      },
      {
        "dimension": "防火与应急疏散",
        "focus": "防火分区划分",
        "requirement": "医疗建筑内的精密贵重医疗设备用房等，均应采用耐火极限不低于2.00h的防火隔墙与其他部分隔开。",
        "source": "《建筑防火通用规范》 第4.1.3条；《综合医院建筑设计标准》 第5.2.42条",
        "suggestion": "严格依标准划分防火分区。消火栓及强弱电管网井门必须在平面中隐蔽化、防碰设计，并加装儿童无法开启的防护罩。"
      },
      {
        "dimension": "防火与应急疏散",
        "focus": "疏散通道宽度",
        "requirement": "疏散走道、首层疏散外门、公共建筑中的室内疏散楼梯的净宽度均不应小于1.1m。",
        "source": "《建筑防火通用规范》 第7.1.4条",
        "suggestion": "门诊区域家长抱行及推车较多，疏散走道净宽在满足规范底线（1.1m）的前提下，必须维持≥2.40m的工艺净宽。"
      },
      {
        "dimension": "防火与应急疏散",
        "focus": "消防设施配置",
        "requirement": "建筑内消防应急照明连续供电时间：医疗建筑不应小于1.0h。疏散走道、人员密集的场所地面最低水平照度不应低于3.0lx。",
        "source": "《建筑防火通用规范》 第10.1.4条、第10.1.10条（强条修正）",
        "suggestion": "关键修正： 门诊公共候诊区和疏散走道的水平应急照明照度严格执行≥3.0lx，系统连续备用供电时间严刚性执行≥60min。"
      },
      {
        "dimension": "防火与应急疏散",
        "focus": "疏散标识适配",
        "requirement": "医疗用房应设置疏散指示标识；指示标志及其设置间距、照度应保证疏散路线指示明确、方向指示正确清晰、视觉连续。",
        "source": "《建筑防火通用规范》 第10.1.8条；《综合医院建筑设计标准》 第5.24.4条",
        "suggestion": "消防应急标志灯设置在走道及转角处距地面高度1.0m以下的墙面上。诊区增加距地0.5m的卡通夜光指示，配温和语音广播。"
      },
      {
        "dimension": "无障碍",
        "focus": "无障碍空间预留",
        "requirement": "建筑内横向应采用防火墙等划分防火分区；无障碍设施设计应符合现行无障碍设计规范。",
        "source": "《建筑防火通用规范》GB 55037-2022 第4.1.2条；《综合医院建筑设计标准》 第5.1.13条",
        "suggestion": "门诊出入口、主通道及大厅节点必须预留大于1.5m×1.5m的轮椅/平车回转空间，通道全程无高差过渡。"
      },
      {
        "dimension": "无障碍",
        "focus": "设施适配性",
        "requirement": "门诊用房应设置醒目标识系统，方便和引导患者就诊。无障碍专用卫生间旁应装置安全抓杆。",
        "source": "《综合医院建筑设计标准》 第5.1.13条、第5.3.1条",
        "suggestion": "在主要通行轴线旁规划专用轮椅/童车停放区，距离各诊疗模块入口≤10m。所有公共窗口端部均设无障碍服务位。"
      },
      {
        "dimension": "无障碍",
        "focus": "通行无高差",
        "requirement": "地下或半地下公共活动场所内部装修材料的燃烧性能均应为A级。",
        "source": "《建筑防火通用规范》 第6.5.6条",
        "suggestion": "清除任何门槛带来的高差。诊区内部由于结构高差需设坡道时，坡度严禁大于1:12，并设置水平缓冲段。"
      },
      {
        "dimension": "无障碍",
        "focus": "服务点位无障碍",
        "requirement": "卫生间的设置应结合使用需求合理布局，应宜设置无性别、无障碍患者专用卫生间。应设高低位窗口。",
        "source": "《综合医院建筑设计标准》第5.1.13条",
        "suggestion": "低位无障碍服务窗口台面高度≤0.75m，下部容膝空间深度≥0.45m、高度≥0.65m。配双向L型安全抓杆和紧急呼叫按钮。"
      },
      {
        "dimension": "协作配套",
        "focus": "医技/治疗区衔接",
        "requirement": "门诊部应设在靠近医院交通入口处，应与医技用房邻近，与急诊有便捷的通道。",
        "source": "《综合医院建筑设计标准》第5.2.1条",
        "suggestion": "紧邻诊区单元设置高频采血、留观、微型化验专属点，诊区核心出入口至主要医技辅助区的步行交通距离≤30m。"
      },
      {
        "dimension": "协作配套",
        "focus": "服务功能整合",
        "requirement": "公共区域宜设门厅、中庭、一站式服务、自助服务、挂号缴费、门诊药房等空间和用房。",
        "source": "《综合医院建筑设计标准》第5.2.2A条",
        "suggestion": "废除传统单一收费窗。采用一站式“集成综合岛”，将挂号、缴费、打印、医保结算、咨询功能100%全线上及岛内合并。"
      },
      {
        "dimension": "协作配套",
        "focus": "配套设施分布",
        "requirement": "儿童医院应设置哺乳室、无性别卫生间、婴儿整理台等设施。",
        "source": "《儿童医院建设标准》 第三十八条；",
        "suggestion": "增设临时哺乳角，无性别公共卫生间内必须刚性配置一体化折叠式婴儿尿布整理台。"
      },
      {
        "dimension": "协作配套",
        "focus": "儿童友好适配",
        "requirement": "卫生间应设置儿童卫生间或儿童专用洁具等。儿童诊疗区域的门窗、家具和楼地面等应采取必要的安全保护措施。",
        "source": "《综合医院建设标准》第三十九条",
        "suggestion": "卫生间洁具按成人/儿童1:1配置。儿童洗手台高度0.55m。室内所有墙面转角、固定式家具边缘均做防磕碰圆弧设计。"
      },
      {
        "dimension": "感控要求",
        "focus": "感控分区合理性",
        "requirement": "设传染病（感染疾病）门诊的儿童医院，应合理布置，避免交叉感染。医疗业务用房应符合医院感染预防与控制基本原则。",
        "source": "《儿童医院建设标准》 第二十五条、第三十四条",
        "suggestion": "诊区单元间设物理封闭屏障（隔墙/防烟垂壁）。严格按低饱和度颜色定义“清洁区-半污染区-污染区”单向流线。"
      },
      {
        "dimension": "感控要求",
        "focus": "手卫生设施配置",
        "requirement": "诊室、检验科等房间的洗手盆应采用非手动开关，并应采取防止污水外溅的措施。",
        "source": "《综合医院建筑设计标准》 第6.2.5条、第6.2.6条",
        "suggestion": "诊室内部、分诊台及检查室门口100%配设感应式手卫生设施。洗手盆做防喷溅凹陷深度设计，避免幼儿溅水。"
      },
      {
        "dimension": "感控要求",
        "focus": "污废处理流程",
        "requirement": "废弃物的集中收集存放用房宜远离主要业务用房。相关的洗涤池和排水管应采用耐腐蚀材料。",
        "source": "《综合医院建筑设计标准》 第4.2.1条、第5.1.12条",
        "suggestion": "医废密闭暂存间置于诊区尽端隐蔽处。污物收集动线利用医护通道进行时段化管理，严禁与患者高峰期动线重叠。"
      },
      {
        "dimension": "感控要求",
        "focus": "发热患儿隔离",
        "requirement": "感染疾病门诊（发热门诊）均应自成一区，与普通门（急）诊设置严密隔离设施，并应单独设置出入口及醒目标识。",
        "source": "《综合医院建筑设计标准》 第5.4.1条",
        "suggestion": "预检分诊处实现普通与发热物理分流。发热筛查区设独立出入口，并配置完全独立的负压机械通风与消毒设施。"
      }
    ],
    "docFacts": [
      "功能区面积配比：儿科候诊区面积应按不小于2㎡/人设计。母婴室应设置独立房间且使用面积不应低于10.0㎡。",
      "房间短边净宽：双人诊查室的开间净尺寸不应小于3.00m，单人诊查室不应小于2.50m。诊查室室内净高不宜低于2.60m。",
      "操作空间预留：各个功能用房空间尺寸应符合医疗操作规范和防护等相关要求，包括医疗行为空间尺度。",
      "服务点位尺度：候诊区附近宜设置儿童活动区，墙体与地面应为软质材料。儿科区域宜设置母婴室。",
      "诊疗动线闭环性：门诊部流线应科学、合理并符合感染控制要求。预检分诊功能与设施应设于门诊入口处附近。",
      "医患/洁污流线：洁污、医患、人车等流线组织清晰，避免交叉。利用走道单侧候诊时，走道净宽不小于2.40m，双侧不小于3.00m。"
    ],
    "docReview": [
      "空间尺度 / 功能区面积配比：候诊区指标严格执行≥2.0㎡/人。双人或带特殊检查功能的诊室使用面积优化为≥12.0㎡（契合模块化网格布局）。",
      "空间尺度 / 房间短边净宽：诊室短边（开间）净宽统一优化为≥3.00m。诊室通行木门规格标准化：统一采用1000mm宽单扇平开门。",
      "空间尺度 / 操作空间预留：诊查桌与检查床一体化连体布置，取消不必要的移动手推车。检查床侧边预留操作通道净宽≥0.90m。",
      "空间尺度 / 服务点位尺度：诊区内规划“就诊-游戏-家长休息”综合岛。儿童活动角净面积≥8.0㎡，界面采用无阴影软质包覆。",
      "流线效率 / 诊疗动线闭环性：组织“预检-分诊-专科候诊-诊室-离院”单向流线。跨区动线限制在20m内。",
      "流线效率 / 医患/洁污流线：严格实行医护双通道布局。次通道（诊区走廊）单侧候诊净宽设计为2.40m，衔接转角处预留≥1.5㎡的童车/亲子缓冲空间。",
      "流线效率 / 专科动线独立性：特殊门诊（口腔科、发热筛查等）采用尽端式独立分区。",
      "流线效率 / 通行适配性：设置高低位双层扶手（0.6m及0.9m）。导视全图形化，中文标签粗体100%内置于房间几何框内。"
    ],
    "docBrief": "门诊整层平面（SketchUp 实景模型）审图重点包括功能区面积配比、房间短边净宽、操作空间预留等内容；依据GB 51039-2014《综合医院建筑设计标准》 第5.2.6条、第5.1.15条；GB 51039-2014《综合医院建筑设计标准》 第5.2.4条、第5.1.9条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "siteModel": "models/viewer.html?scene=opd-floor",
    "glbModelName": "实景模型（SketchUp 导出）",
    "sceneInfo": {
      "area": "24.00 × 16.00 m 信息模型 · 净高 3.40m（医疗街 + 树状科室模块）",
      "dims": {
        "def": [
          24,
          16,
          3.4
        ],
        "min": [
          20,
          13.5,
          3
        ],
        "sugg": [
          28,
          18,
          3.6
        ],
        "minLabel": "紧凑门诊",
        "suggLabel": "扩展门诊"
      },
      "stats": {
        "furn": 30,
        "markers": 12
      },
      "cost": "整层工艺信息模型：按区域/构件拆分估算",
      "thumb": "assets/img/scene-thumbs/opd-floor.jpg",
      "modelScope": "关系模型",
      "measurementNotice": "仅表达科室分区、邻接与流程关系，不可用于房间净距或设备安装量测。"
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 7,
      "priority": "P1",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 9,
      "finalStatus": "部分完成",
      "finalRequirement": "明确关系模型属性并提示不可量测；GLB 重导出前不作为合规量测底图。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）",
    "glbModelDisabledReason": "2026-07-13 GLB 包围核查发现尺度、原点或游离构件异常；程序场景保留，清理并统一米制重导前禁用实景切换。",
    "glbAuditStatus": "隔离待重导"
  },
  {
    "id": "opd_triage",
    "dept": "门诊",
    "name": "分诊候诊单元",
    "type": "waiting",
    "priority": "P1",
    "summary": "分诊候诊单元已按门诊整层平面逻辑校准：作为医疗街入口后的首个控制节点，组织预检报到、一级候诊、二次候诊、通往诊室、亲子/母婴与无障碍停靠，重点核对儿科候诊≥2.0㎡/人、通道净宽、视线覆盖和感控分区。",
    "assets": [
      "docs/materials/2026.7.6/门诊/行为示意图/优化门诊分诊候诊单元.png",
      "docs/materials/2026.7.6/门诊/轴测/分诊候诊单元.png",
      "docs/materials/2026.7.6/门诊/CAD/门诊平面_t3.dwg"
    ],
    "preview": "assets/img/previews/opd_registration.jpg",
    "rules": [
      "area",
      "privacy",
      "child",
      "infection"
    ],
    "siteModel": "models/viewer.html?scene=opd-triage",
    "siteModelName": "3D交互信息模型（分诊候诊单元·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "分诊候诊单元审图重点包括候诊面积指标配比、诊区通道净宽尺度、无障碍及亲子预留等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.2.6条第4款、第5.1.9条第2款；《综合医院建筑设计标准》GB 51039-2014 第5.2.6条第2款复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "候诊面积指标配比：儿科候诊区面积应按不小于2.0㎡/人设计。公共走道室内净高不应低于2.30m。",
      "诊区通道净宽尺度：利用走道单侧候诊时，走道净宽不应小于2.40m；两侧候诊时，走道净宽不应小于3.00m。",
      "无障碍及亲子预留：建筑无障碍设施设计应符合规范。建筑设计应充分考虑使用人群的生理与心理特点。",
      "儿童游戏活动空间：候诊区附近宜设置儿童活动区，儿科等区域卫生间应设置儿童专用洁具等。",
      "高等级地面防滑：地面应选用防滑、易清洗的材料。",
      "全立面防磕阳角：儿童可触及部位的阳角应做成圆弧。儿童诊疗区域等应采取必要的安全保护措施。"
    ],
    "docReview": [
      "空间模数与净空 / 候诊面积指标配比：现行儿科候诊红线指标为2.0㎡/人。三级工艺图纸中必须按 ≥2.0㎡/就诊人次（含陪护）足额划定2D范围线框，严禁采用旧体系中0.8㎡~1.0㎡的错误低参数。",
      "空间模数与净空 / 诊区通道净宽尺度：诊区内部候诊走廊，单侧设排椅候诊时其通行有效净宽刚性设计 ≥2.40m（图面上必须精准扣除固定座椅本身厚度），保持纯白背景。",
      "空间模数与净空 / 无障碍及亲子预留：分诊岛台旁、交通节点处必须在平面中绘制出 ≥1.5m×1.5m 轮椅/平车回转边界线，且通道端部预留 ≥1.5㎡ 的专属童车停放区。",
      "空间模数与净空 / 儿童游戏活动空间：单元内独立规划儿童游戏活动角，净面积 ≥10.0㎡，按年龄段软质分区。紧邻配置独立的无性别亲子卫生间及 ≥3.0㎡ 临时哺乳角。",
      "室内装修与防护 / 高等级地面防滑：2D平面中统一设计为无缝同质透心防滑PVC地板，防滑等级严格执行 ≥R11，踢脚线处做墙地一体化上翻150mm。",
      "室内装修与防护 / 全立面防磕阳角：候诊单元内所有结构柱体、分诊吧台、低位窗台阳角，物理上必须做 R≥20mm的圆弧或防撞橡胶软包覆，全面消除锐角。",
      "室内装修与防护 / 界面整体防撞软包：去重优化建议： 刚性淘汰易带来儿童攀爬翻越及防夹隐患的“固定防撞护栏”。优化为在活动角墙面1.5m高度以下全部铺设B1级阻燃、低饱和度色调的防撞软包。",
      "建筑防火与疏散 / 空间装修燃烧性能：图纸技术说明中刚性明示：顶棚、基层墙面均采用A级不燃材料，地面PVC、固定排椅及墙面防撞软包材料均不低于B1级阻燃。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "候诊面积指标配比",
        "requirement": "儿科候诊区面积应按不小于2.0㎡/人设计。公共走道室内净高不应低于2.30m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.2.6条第4款、第5.1.9条第2款",
        "suggestion": "现行儿科候诊红线指标为2.0㎡/人。三级工艺图纸中必须按 ≥2.0㎡/就诊人次（含陪护）足额划定2D范围线框，严禁采用旧体系中0.8㎡~1.0㎡的错误低参数。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "诊区通道净宽尺度",
        "requirement": "利用走道单侧候诊时，走道净宽不应小于2.40m；两侧候诊时，走道净宽不应小于3.00m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.2.6条第2款",
        "suggestion": "诊区内部候诊走廊，单侧设排椅候诊时其通行有效净宽刚性设计 ≥2.40m（图面上必须精准扣除固定座椅本身厚度），保持纯白背景。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "无障碍及亲子预留",
        "requirement": "建筑无障碍设施设计应符合规范。建筑设计应充分考虑使用人群的生理与心理特点。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.13条第6款；《综合医院建设标准》第五条",
        "suggestion": "分诊岛台旁、交通节点处必须在平面中绘制出 ≥1.5m×1.5m 轮椅/平车回转边界线，且通道端部预留 ≥1.5㎡ 的专属童车停放区。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "儿童游戏活动空间",
        "requirement": "候诊区附近宜设置儿童活动区，儿科等区域卫生间应设置儿童专用洁具等。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.2.6条第6款；《综合医院建设标准》第六款",
        "suggestion": "单元内独立规划儿童游戏活动角，净面积 ≥10.0㎡，按年龄段软质分区。紧邻配置独立的无性别亲子卫生间及 ≥3.0㎡ 临时哺乳角。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "高等级地面防滑",
        "requirement": "地面应选用防滑、易清洗的材料。",
        "source": "《综合医院建设标准》第三十九条第四款",
        "suggestion": "2D平面中统一设计为无缝同质透心防滑PVC地板，防滑等级严格执行 ≥R11，踢脚线处做墙地一体化上翻150mm。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "全立面防磕阳角",
        "requirement": "儿童可触及部位的阳角应做成圆弧。儿童诊疗区域等应采取必要的安全保护措施。",
        "source": "《综合医院建设标准》第三十九条第七款、第六款",
        "suggestion": "候诊单元内所有结构柱体、分诊吧台、低位窗台阳角，物理上必须做 R≥20mm的圆弧或防撞橡胶软包覆，全面消除锐角。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "界面整体防撞软包",
        "requirement": "内墙墙体不应使用易裂、易燃、不耐碰撞的材料。",
        "source": "《综合医院建设标准》第三十九条第三款",
        "suggestion": "去重优化建议： 刚性淘汰易带来儿童攀爬翻越及防夹隐患的“固定防撞护栏”。优化为在活动角墙面1.5m高度以下全部铺设B1级阻燃、低饱和度色调的防撞软包。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "空间装修燃烧性能",
        "requirement": "建筑内人员密集的场所，其内部装修材料的燃烧性能均应为A级（顶棚、墙面）和不低于B1级（地面）。",
        "source": "《建筑防火通用规范》GB 55037-2022 第6.5.6条",
        "suggestion": "图纸技术说明中刚性明示：顶棚、基层墙面均采用A级不燃材料，地面PVC、固定排椅及墙面防撞软包材料均不低于B1级阻燃。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "安全出口及间距",
        "requirement": "每个防火分区或一个防火分区的每个楼层，安全出口不应少于2个。建筑内各安全出口的净距离不应小于5.0m。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.1条及其第3款",
        "suggestion": "高度精炼去重： 将分散的出口数量与间距归并。分诊候诊单元所在防火分区安全出口数量刚性执行 ≥2个，且两个疏散门之间的绝对水平净距离严格执行 ≥5.0m。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "疏散门及开启宽度",
        "requirement": "疏散走道、疏散门和安全出口的净宽度应符合消防底线。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.4条",
        "suggestion": "诊区大门统一采用净宽 ≥1200mm 的双扇平开电磁常开防火门（火灾时自动释放关闭），确保顺疏散方向开启且不占用外侧走廊净宽。"
      },
      {
        "dimension": "建筑防火与疏散",
        "focus": "排烟设施及应急照明",
        "requirement": "医疗建筑消防应急照明备用电源连续供电时间不应小于1.0h。人员密集场所地面最低水平照度不应低于3.0lx。",
        "source": "《建筑防火通用规范》GB 55037-2022 第8.2.1条、第10.1.4条、第10.1.10条 （核心强条修正）",
        "suggestion": "强条刚性修正： 彻底废除原表“0.5h”旧标。本单元地面水平应急照度刚性执行 ≥3.0lx，系统连续备用供电时间刚性执行 ≥60分钟。吊顶内依防烟分区规划机械排烟。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "非接触手卫生点位",
        "requirement": "诊室、分诊台门口、治疗室等房间的洗手盆应采用非手动开关，并应采取防止污水外溅的措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第6.2.5条第4款",
        "suggestion": "分诊台核心区及诊室入口连线上100%配置非接触式感应手卫生设施（感应手消点或感应洗手池），出水做防喷溅凹陷工艺优化。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "高频接触耐消面",
        "requirement": "阳角及高频接触面应易清洁消毒。台面、座椅均应采用易洁净、耐腐蚀的面层。",
        "source": "《综合医院建设标准》第三十九条第六款",
        "suggestion": "分诊服务台采用整体抗菌无缝实体面材。所有中文简体粗体标签（如：分诊台、排椅、无障碍位）一律 100%内置于线框内，取消外引线。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "隐藏式污废处理",
        "requirement": "医疗业务用房废弃物应封闭处理。废弃物的集中收集存放用房宜远离主要业务用房。",
        "source": "《儿童医院建设标准》建标174-2016 第三十四条；《综合医院建筑设计标准》 第4.2.1条",
        "suggestion": "严禁生活或医疗垃圾桶暴露在候诊大厅。必须在分诊岛台内侧或排椅侧方规划嵌壁隐藏式、带盖密封分类垃圾收集点位。"
      }
    ],
    "sceneInfo": {
      "thumb": "assets/img/scene-thumbs/opd-triage.jpg",
      "area": "8.40 × 7.20 m 医疗街接入节点 · 净高 3.10m（≈60.5㎡，可参数化）",
      "dims": {
        "def": [
          8.4,
          7.2,
          3.1
        ],
        "min": [
          7.2,
          6.4,
          3
        ],
        "sugg": [
          9.6,
          8,
          3.2
        ],
        "minLabel": "紧凑门诊节点",
        "suggLabel": "高峰候诊节点"
      },
      "stats": {
        "furn": 11,
        "markers": 8
      },
      "cost": "约 2.9–11.8 万元"
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 5,
      "priority": "P1",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 7,
      "finalStatus": "部分完成",
      "finalRequirement": "活动角退出入口并标注安抚角；独立 8m² 诊区；校正给排水构件坐标。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "ed_cpr",
    "dept": "急诊",
    "name": "心肺复苏室",
    "type": "resus",
    "priority": "P2",
    "summary": "心肺复苏室审图重点包括复苏床极限操作面积、岛式布局与操作净距、吊顶荷载与净高预留等内容；依据《综合医院建筑设计标准》GB 51039-2014第5.3.11条；《综合医院建筑设计标准》GB 51039-2014第5.1.9条及第4.3.2条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/急诊/行为示意图/心肺复苏.png",
      "docs/materials/2026.7.6/急诊/轴测/心肺复苏轴测.jpg",
      "docs/materials/2026.7.6/急诊/CAD/7.6_急诊集合_t3.dwg"
    ],
    "rules": [
      "area",
      "handwash",
      "privacy",
      "child"
    ],
    "siteModel": "models/viewer.html?scene=er-cpr",
    "siteModelName": "3D交互信息模型（心肺复苏室·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "心肺复苏室审图重点包括复苏床极限操作面积、岛式布局与操作净距、吊顶荷载与净高预留等内容；依据《综合医院建筑设计标准》GB 51039-2014第5.3.11条；《综合医院建筑设计标准》GB 51039-2014第5.1.9条及第4.3.2条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "复苏床极限操作面积：急诊抢救室每床净使用面积不应小于12.00㎡。",
      "岛式布局与操作净距：抢救床净间距不应小于1.20m。",
      "吊顶荷载与净高预留：医疗用房的室内净高不宜低于2.60m。建筑结构设计应满足医疗设备、悬挂装置等对荷载及安装的要求。",
      "上悬挂无地轨平移门：疏散出口门、疏散走道中的门应向疏散方向开启，且不应设置门槛。",
      "核心救治区防火分隔：医院中的手术部、急诊部、重症监护室、贵重精密医疗设备用房等，应采用防火隔墙和不燃楼板与其他部位分隔。",
      "装修材料燃烧性能：医疗建筑内部装修材料的燃烧性能等级不应低于A级，部分部位不应低于B1级。"
    ],
    "docReview": [
      "空间模数与净空 / 复苏床极限操作面积：心肺复苏涉及气管插管、除颤及可能介入的ECMO设备，单床净使用面积建议极度放大至20.00㎡至25.00㎡。",
      "空间模数与净空 / 岛式布局与操作净距：复苏床必须执行岛式布局。床头区域需预留大于或等于1.00m的气管插管操作专区，床两侧操作净距必须大于或等于1.50m。",
      "空间模数与净空 / 吊顶荷载与净高预留：为容纳重型双臂外科吊塔及无影灯，室内吊顶完成面净高建议设定为3.00m。图纸必须提供天花板承重钢结构的受力节点大样图。",
      "防火分隔与应急 / 上悬挂无地轨平移门：门洞净宽必须大于或等于1.50m。自动平移门必须采用“上悬挂式无下地轨”工艺，彻底杜绝地面轨道凹槽积聚血污，同时确保抢救床无震动推入。门体必须带防撞脱轨应急推开功能。",
      "防火分隔与应急 / 核心救治区防火分隔：复苏室作为急诊部内最高级别的火灾管控孤岛，其四周封闭墙体必须为耐火极限不低于2.00h的防爆防火实体墙，严禁采用轻钢龙骨石膏板简易隔断。",
      "防火分隔与应急 / 装修材料燃烧性能：室内吊顶、顶棚及墙面基层必须全部采用A级不燃材料，立面防撞树脂板必须提供B1级以上阻燃检测报告。",
      "感控要求与设施 / 外科级洗手终端配置：复苏室内入口处必须配置外科级别深水槽洗手池。配备膝碰式或感应式出水开关、感应手消，并加装出水温度锁定在35℃至38℃的恒温防烫阀。",
      "感控要求与设施 / 地面冲洗与医疗地漏：抢救常伴随大量体液遗洒，复苏床侧边必须设置医疗级可开启式密封防溢地漏，平时处于绝对物理锁死状态，严防气溶胶倒灌。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "复苏床极限操作面积",
        "requirement": "急诊抢救室每床净使用面积不应小于12.00㎡。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.3.11条",
        "suggestion": "心肺复苏涉及气管插管、除颤及可能介入的ECMO设备，单床净使用面积建议极度放大至20.00㎡至25.00㎡。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "岛式布局与操作净距",
        "requirement": "抢救床净间距不应小于1.20m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.3.11条",
        "suggestion": "复苏床必须执行岛式布局。床头区域需预留大于或等于1.00m的气管插管操作专区，床两侧操作净距必须大于或等于1.50m。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "吊顶荷载与净高预留",
        "requirement": "医疗用房的室内净高不宜低于2.60m。建筑结构设计应满足医疗设备、悬挂装置等对荷载及安装的要求。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.9条及第4.3.2条",
        "suggestion": "为容纳重型双臂外科吊塔及无影灯，室内吊顶完成面净高建议设定为3.00m。图纸必须提供天花板承重钢结构的受力节点大样图。"
      },
      {
        "dimension": "防火分隔与应急",
        "focus": "上悬挂无地轨平移门",
        "requirement": "疏散出口门、疏散走道中的门应向疏散方向开启，且不应设置门槛。",
        "source": "《建筑防火通用规范》GB 55037-2022第7.2.1条",
        "suggestion": "门洞净宽必须大于或等于1.50m。自动平移门必须采用“上悬挂式无下地轨”工艺，彻底杜绝地面轨道凹槽积聚血污，同时确保抢救床无震动推入。门体必须带防撞脱轨应急推开功能。"
      },
      {
        "dimension": "防火分隔与应急",
        "focus": "核心救治区防火分隔",
        "requirement": "医院中的手术部、急诊部、重症监护室、贵重精密医疗设备用房等，应采用防火隔墙和不燃楼板与其他部位分隔。",
        "source": "《建筑防火通用规范》GB 55037-2022第4.3.1条",
        "suggestion": "复苏室作为急诊部内最高级别的火灾管控孤岛，其四周封闭墙体必须为耐火极限不低于2.00h的防爆防火实体墙，严禁采用轻钢龙骨石膏板简易隔断。"
      },
      {
        "dimension": "防火分隔与应急",
        "focus": "装修材料燃烧性能",
        "requirement": "医疗建筑内部装修材料的燃烧性能等级不应低于A级，部分部位不应低于B1级。",
        "source": "《建筑防火通用规范》GB 55037-2022第6.1.1条",
        "suggestion": "室内吊顶、顶棚及墙面基层必须全部采用A级不燃材料，立面防撞树脂板必须提供B1级以上阻燃检测报告。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "外科级洗手终端配置",
        "requirement": "医疗用房的洗手盆应采用非手动开关，水龙头不应采用充气式，并应采取防止污水外溅的措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第6.2.5条及第6.2.6条",
        "suggestion": "复苏室内入口处必须配置外科级别深水槽洗手池。配备膝碰式或感应式出水开关、感应手消，并加装出水温度锁定在35℃至38℃的恒温防烫阀。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "地面冲洗与医疗地漏",
        "requirement": "有水区域应设地漏。地漏应采用带防干涸水封的地漏，水封深度不得小于50mm。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第6.2.7条",
        "suggestion": "抢救常伴随大量体液遗洒，复苏床侧边必须设置医疗级可开启式密封防溢地漏，平时处于绝对物理锁死状态，严防气溶胶倒灌。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "独立环控与正负压",
        "requirement": "医疗用房应通风良好。采取有效措施防止交叉感染。急诊抢救室宜具有可切换为负压排风功能的条件。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第7.1.1条及第7.1.11条",
        "suggestion": "复苏室必须配置完全独立的空调与新风排风系统。系统需具备一键正负压切换功能，正压保护严重创伤患儿，负压隔离传染患儿。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "地材抗污与防静电",
        "requirement": "医疗用房的地面应平整、防滑、易清洁、耐磨、耐腐蚀、不产尘，部分医疗用房地面应防静电。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.10条",
        "suggestion": "地面必须满铺防静电、耐血液腐蚀的3.0mm同质透心PVC卷材，上卷上墙15cm形成圆弧阴角。接缝必须采用热熔无缝焊接。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "阴阳角与极限防撞",
        "requirement": "其阴阳角宜做成圆角。有推床或推车通过的门和墙面，应采取防碰撞措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.12条及第39条（三）",
        "suggestion": "室内所有墙角、柱角必须执行半径大于或等于50mm的强化圆角工艺。墙面0.20m至0.90m区间建议满铺高强度抗撞击医用树脂板。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "吸音与声学阻断隔离",
        "requirement": "综合医院注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
        "source": "《综合医院建设标准》建标110-2021第五条",
        "suggestion": "复苏室的隔墙必须为隔音砌块并砌筑至顶板，室内顶棚必须满铺降噪系数大于或等于0.8的高效吸音板，防止抢救指令穿透墙体。"
      },
      {
        "dimension": "视觉干预与隐私",
        "focus": "标准时钟与生命计时",
        "requirement": "手术室、急诊抢救室、重症监护室等应设置标准时钟。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第9.3.5条",
        "suggestion": "抢救床正前方墙面的可视黄金高度，必须预留并安装具备读秒功能的高精度数字时钟面板，且必须与全院母钟系统实时同步。"
      },
      {
        "dimension": "视觉干预与隐私",
        "focus": "外部视线绝对物理隔绝",
        "requirement": "检查、治疗用房应满足使用人群的隐私要求，注意开门方向，宜设闭门器。",
        "source": "《综合医院建设标准》建标110-2021第三十九条（八）",
        "suggestion": "复苏室大门开向严禁直对候诊大厅，门上观察窗必须配置内置百叶或通电雾化隐私玻璃，阻断外部的恐慌性围观。"
      },
      {
        "dimension": "视觉干预与隐私",
        "focus": "抢救区顶部视觉干预",
        "requirement": "综合医院注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
        "source": "《综合医院建设标准》建标110-2021第五条",
        "suggestion": "建议避开无影灯区域，在天花板安装具有舒缓图案的发光背板或动态投影介质，缓解部分非昏迷创伤患儿的极度恐惧。"
      }
    ],
    "preview": "assets/img/previews/ed_cpr.jpg",
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 25,
      "priority": "P2",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 27,
      "finalStatus": "已完成",
      "finalRequirement": "保留按压机与床允许接触，并提供运动状态。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "ed_debridement",
    "dept": "急诊",
    "name": "清创处置室",
    "type": "treatment",
    "priority": "P3",
    "summary": "清创处置室审图重点包括清创操作空间界限、室内吊顶净高控制、门洞净宽与无障碍等内容；依据《综合医院建筑设计标准》GB 51039-2014第5.1.1条；《综合医院建筑设计标准》GB 51039-2014第5.1.9条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/急诊/行为示意图/清创2.0.png",
      "docs/materials/2026.7.6/急诊/CAD/7.6_急诊集合_t3.dwg",
      "docs/materials/2026.7.13/急诊/轴测/清创处置室.png"
    ],
    "preview": "assets/img/previews/ed_debridement.jpg",
    "rules": [
      "area",
      "handwash",
      "privacy",
      "child"
    ],
    "siteModel": "models/viewer.html?scene=er-debridement",
    "siteModelName": "3D交互信息模型（清创处置室·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "清创处置室审图重点包括清创操作空间界限、室内吊顶净高控制、门洞净宽与无障碍等内容；依据《综合医院建筑设计标准》GB 51039-2014第5.1.1条；《综合医院建筑设计标准》GB 51039-2014第5.1.9条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "清创操作空间界限：医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理、洁污路线清楚。",
      "室内吊顶净高控制：医疗用房的室内净高不宜低于2.60m。",
      "门洞净宽与无障碍：通向推床的门净宽不应小于1.10m。疏散出口门应为平开门或在火灾时具有平开功能的门，且不应设置门槛。",
      "装修材料燃烧性能：医疗建筑内部装修材料的燃烧性能等级不应低于A级，部分部位不应低于B1级。",
      "洗手终端与防飞溅：医疗用房的洗手盆应采用非手动开关，水龙头不应采用充气式，并应采取防止污水外溅的措施。",
      "地面冲洗与防溢地漏：卫生间、污洗间、洗涤等有水区域应设地漏。地漏应采用带防干涸水封的地漏，水封深度不得小于50mm。"
    ],
    "docReview": [
      "空间模数与净空 / 清创操作空间界限：清创床四周必须留出至少1.20m的净操作通道，以容纳主刀医生、护士、器械车及家属。建议房间净使用面积不小于15.00㎡。",
      "空间模数与净空 / 室内吊顶净高控制：为保证无影灯臂旋转半径及避免压抑感，室内吊顶完成面净高建议设定为2.80m。",
      "防火分隔与应急 / 门洞净宽与无障碍：门洞净宽建议设计为1.20m的单扇门或1.30m的子母门，保证平推车顺畅进出。门下地面必须绝对零门槛平接处理。",
      "防火分隔与应急 / 装修材料燃烧性能：室内吊顶及顶棚必须采用A级不燃材料，墙面抗菌树脂板等立面防护材料必须提供B1级以上阻燃检测报告。",
      "感控要求与设施 / 洗手终端与防飞溅：洗手池必须采用深度大于0.25m的深水槽，配置肘开式或感应式龙头，加装恒温防烫阀，墙面铺设高1.20m防溅抗菌板。",
      "感控要求与设施 / 地面冲洗与防溢地漏：清创床下方或侧边必须设置医疗级可开启式密封地漏。非冲洗状态下必须绝对密闭，彻底杜绝下水管道气溶胶与异味倒灌入室。",
      "感控要求与设施 / 独立排风与异味控制：清创室内必须设置完全独立的机械排风系统（直排室外），保持室内相对于走廊为微负压状态，严禁气味溢出至公共候诊区。",
      "感控要求与设施 / 医疗废弃物暂存区：室内必须在靠近污物出口的隐蔽侧，硬性划定一块“医疗废弃物脚踏桶”的专属靠墙摆放区，严禁占用主操作动线。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "清创操作空间界限",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理、洁污路线清楚。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.1条",
        "suggestion": "清创床四周必须留出至少1.20m的净操作通道，以容纳主刀医生、护士、器械车及家属。建议房间净使用面积不小于15.00㎡。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "室内吊顶净高控制",
        "requirement": "医疗用房的室内净高不宜低于2.60m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.9条",
        "suggestion": "为保证无影灯臂旋转半径及避免压抑感，室内吊顶完成面净高建议设定为2.80m。"
      },
      {
        "dimension": "防火分隔与应急",
        "focus": "门洞净宽与无障碍",
        "requirement": "通向推床的门净宽不应小于1.10m。疏散出口门应为平开门或在火灾时具有平开功能的门，且不应设置门槛。",
        "source": "《综合医院建筑设计标准》第5.1.4条及《建筑防火通用规范》第7.2.1条",
        "suggestion": "门洞净宽建议设计为1.20m的单扇门或1.30m的子母门，保证平推车顺畅进出。门下地面必须绝对零门槛平接处理。"
      },
      {
        "dimension": "防火分隔与应急",
        "focus": "装修材料燃烧性能",
        "requirement": "医疗建筑内部装修材料的燃烧性能等级不应低于A级，部分部位不应低于B1级。",
        "source": "《建筑防火通用规范》GB 55037-2022第6.1.1条",
        "suggestion": "室内吊顶及顶棚必须采用A级不燃材料，墙面抗菌树脂板等立面防护材料必须提供B1级以上阻燃检测报告。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "洗手终端与防飞溅",
        "requirement": "医疗用房的洗手盆应采用非手动开关，水龙头不应采用充气式，并应采取防止污水外溅的措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第6.2.5条及第6.2.6条",
        "suggestion": "洗手池必须采用深度大于0.25m的深水槽，配置肘开式或感应式龙头，加装恒温防烫阀，墙面铺设高1.20m防溅抗菌板。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "地面冲洗与防溢地漏",
        "requirement": "卫生间、污洗间、洗涤等有水区域应设地漏。地漏应采用带防干涸水封的地漏，水封深度不得小于50mm。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第6.2.7条",
        "suggestion": "清创床下方或侧边必须设置医疗级可开启式密封地漏。非冲洗状态下必须绝对密闭，彻底杜绝下水管道气溶胶与异味倒灌入室。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "独立排风与异味控制",
        "requirement": "医疗用房应通风良好。采取有效措施防止交叉感染。产生气味、水汽及潮湿的房间应设机械排风。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第7.1.1条及第7.1.5条",
        "suggestion": "清创室内必须设置完全独立的机械排风系统（直排室外），保持室内相对于走廊为微负压状态，严禁气味溢出至公共候诊区。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "医疗废弃物暂存区",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理、洁污路线清楚。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.1条",
        "suggestion": "室内必须在靠近污物出口的隐蔽侧，硬性划定一块“医疗废弃物脚踏桶”的专属靠墙摆放区，严禁占用主操作动线。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "地材抗血污与防滑",
        "requirement": "医疗用房的地面应平整、防滑、易清洁、耐磨、耐腐蚀、不产尘。地面不应设地垄沟。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.10条",
        "suggestion": "必须采用防滑等级R10以上的耐腐蚀同质透心PVC卷材，上卷上墙15cm形成圆弧阴角，接缝必须采用热熔焊接防渗漏。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "阴阳角与防撞处理",
        "requirement": "其阴阳角宜做成圆角。有推床或推车通过的门和墙面，应采取防碰撞措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.12条及第39条（三）",
        "suggestion": "所有墙角、柱角必须执行半径大于或等于20mm的圆角工艺。墙面0.20m及0.90m处满铺高强度医用树脂防撞带。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "吸音与防菌吊顶",
        "requirement": "综合医院注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
        "source": "《综合医院建设标准》建标110-2021第五条",
        "suggestion": "清创室的隔墙必须砌筑至天花板真顶。吊顶建议采用兼具防菌易擦洗表面与降噪系数大于或等于0.7内部构造的医用复合金属板。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "内嵌家具与锐器管控",
        "requirement": "儿童诊疗区域的门窗、家具和楼地面等应采取必要的安全保护措施。",
        "source": "《综合医院建设标准》建标110-2021第三十九条（七）",
        "suggestion": "图纸中绘制的内嵌式医疗边台及吊柜，其存放手术刀片、麻醉剂的抽屉或柜门必须标明配置物理门锁或高位隐藏式把手，严防幼儿因好奇误触造成伤害。"
      },
      {
        "dimension": "视觉干预与隐私",
        "focus": "开门方向与视线遮挡",
        "requirement": "检查、治疗用房应满足使用人群的隐私要求，注意开门方向，宜设闭门器。房间内宜设置隔帘或屏风。",
        "source": "《综合医院建设标准》建标110-2021第三十九条（八）",
        "suggestion": "清创室门必须设置闭门器。开门方向必须背对清创床，确保在门被推开瞬间，外部走廊无法直视室内创面处理过程。"
      },
      {
        "dimension": "视觉干预与隐私",
        "focus": "天花板视觉分散设计",
        "requirement": "综合医院注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
        "source": "《综合医院建设标准》建标110-2021第五条",
        "suggestion": "建议在清创床正上方的天花板区域设置背光式卡通发光软膜天花，利用正向视觉吸引转移患儿对清创疼痛的注意力。"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 空间尺寸",
        "requirement": "开间×进深：4500×4500 mm；面积：20m²；净高：不小于2.8m",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "儿童清创建议不小于14㎡；原稿参考：医用建筑设计规范"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 墙面装修",
        "requirement": "墙面采用可擦洗丙烯酸涂料;局部设医用抗菌墙板1500mm高",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "抗菌、易清洁、耐消毒；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 顶棚装修",
        "requirement": "可擦洗石膏板吊顶，平整、防尘、防霉；铝合金阴角线",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "吸声、抗菌、防火；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 地面装修",
        "requirement": "防滑无缝医用PVC卷材，热焊接缝，150mm上翻踢脚",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "防滑、耐磨、易清洁；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 门工程",
        "requirement": "1.5扇门或双开门，门净宽不小于1400mm；可设观察窗并可锁闭",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "防夹手、易清洁；原稿参考：急诊通行要求"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 窗工程",
        "requirement": "中空Low-E玻璃，内置百叶/医用窗帘",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "隔热、隐私保护；原稿参考：实际诊疗需求"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 安全隐私",
        "requirement": "轨道式医用防霉隔帘",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "可伸缩、易清洁；原稿参考：医用建筑设计规范"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 洗手设施",
        "requirement": "配备医用洗手盆及相关配件",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "防溅、易消毒；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "配置复核",
        "focus": "[7.13手册] 家具配置清单",
        "requirement": "儿童诊疗/清创处置床×1（550×550×850）；陪护椅×1（1800×600×850）；医护操作台×1（1200×550×850）；台下储物柜×1（900×350×700）；壁挂带锁药品/器械柜×1（3000×2200）；床位隔帘×1（250×100×140）；医疗废物桶50L×1（320×320×450）；普通废物桶20L×1（300×200×350）；锐器盒11L×1（450×450×50）；医护升降圆凳×1（550×550×850）；患者服务面板/床头面板×1（1600×200×450）；儿童安全防撞护墙板×1（1800×20×900）",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "按真实设备外廓、检修面、门区和操作净空复核；数量为项目手册预设，不替代批准后的设备清单。"
      },
      {
        "dimension": "配置复核",
        "focus": "[7.13手册] 医疗设备配置清单",
        "requirement": "清创/换药治疗车，2抽×1（750×500×900）；器械托盘车×1（600×450×850）；氧气流量计×2（150×60×170）；空气流量计×1（150×60×170）；负压吸引适配器×1（120×60×120）；吸引瓶×1（120×120×250）；吸引瓶支架×1（160×120×180）；移动输液架×1（500×500×1200-2200）；单通道输液泵×1（150×200×180）；患儿生命体征监护仪×1（360×280×300）；壁挂诊断套装×1（250×100×300）；顶装单头检查灯×1（700×700×1200）；儿童约束带/固定带×1（400×300×80）；局麻/缝合小器械包×1（400×300×120）；清创冲洗装置/冲洗壶×1（300×200×250）；冷藏药品冰箱150L×1（600×600×850）",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "按真实设备外廓、检修面、门区和操作净空复核；数量为项目手册预设，不替代批准后的设备清单。"
      },
      {
        "dimension": "源数据校核",
        "focus": "[7.13手册] 原稿数值疑点",
        "requirement": "原稿装备表中“儿童诊疗/清创处置床”等条目疑似存在列位错移；完整保留原表，待编审回看源表后再固化型号与尺寸。",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "待编审确认前标记为“原稿待复核”，不自动生成不合格结论。"
      }
    ],
    "legacySiteModel": "models/model-real.html?space=resus",
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 21,
      "priority": "P3",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 23,
      "finalStatus": "未修改到位",
      "finalRequirement": "用真实墙门分隔前室与处置区；补独立清洁工作台；污物点避开出入口。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "以真实墙门分隔前室与处置区，补清洁工作台并重排污物点、工作位与防护柜。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）",
    "manual713": {
      "title": "图3.x清创处置室示意图（图片来源：网络图片）",
      "overview": "",
      "architecture": [
        {
          "item": "空间尺寸",
          "requirement": "开间×进深：4500×4500 mm；面积：20m²；净高：不小于2.8m",
          "unit": "项",
          "reference": "医用建筑设计规范",
          "note": "儿童清创建议不小于14㎡"
        },
        {
          "item": "墙面装修",
          "requirement": "墙面采用可擦洗丙烯酸涂料;局部设医用抗菌墙板1500mm高",
          "unit": "项",
          "reference": "GB 50333-2013",
          "note": "抗菌、易清洁、耐消毒"
        },
        {
          "item": "顶棚装修",
          "requirement": "可擦洗石膏板吊顶，平整、防尘、防霉；铝合金阴角线",
          "unit": "项",
          "reference": "GB 50333-2013",
          "note": "吸声、抗菌、防火"
        },
        {
          "item": "地面装修",
          "requirement": "防滑无缝医用PVC卷材，热焊接缝，150mm上翻踢脚",
          "unit": "项",
          "reference": "GB 50333-2013",
          "note": "防滑、耐磨、易清洁"
        },
        {
          "item": "门工程",
          "requirement": "1.5扇门或双开门，门净宽不小于1400mm；可设观察窗并可锁闭",
          "unit": "樘",
          "reference": "急诊通行要求",
          "note": "防夹手、易清洁"
        },
        {
          "item": "窗工程",
          "requirement": "中空Low-E玻璃，内置百叶/医用窗帘",
          "unit": "m²",
          "reference": "实际诊疗需求",
          "note": "隔热、隐私保护"
        },
        {
          "item": "安全隐私",
          "requirement": "轨道式医用防霉隔帘",
          "unit": "套",
          "reference": "医用建筑设计规范",
          "note": "可伸缩、易清洁"
        },
        {
          "item": "洗手设施",
          "requirement": "配备医用洗手盆及相关配件",
          "unit": "套",
          "reference": "GB 50333-2013",
          "note": "防溅、易消毒"
        }
      ],
      "equipment": [
        {
          "category": "家具",
          "item": "儿童诊疗/清创处置床",
          "quantity": "1",
          "specification": "550×550×850",
          "note": "家属短时陪护安抚"
        },
        {
          "category": "家具",
          "item": "陪护椅",
          "quantity": "1",
          "specification": "1800×600×850",
          "note": "用于备物、记录、清创准备"
        },
        {
          "category": "家具",
          "item": "医护操作台",
          "quantity": "1",
          "specification": "1200×550×850",
          "note": "可调层板，放置耗材"
        },
        {
          "category": "家具",
          "item": "台下储物柜",
          "quantity": "1",
          "specification": "900×350×700",
          "note": "儿童用药及小器械管理"
        },
        {
          "category": "家具",
          "item": "壁挂带锁药品/器械柜",
          "quantity": "1",
          "specification": "3000×2200",
          "note": "保护患儿隐私"
        },
        {
          "category": "家具",
          "item": "床位隔帘",
          "quantity": "1",
          "specification": "250×100×140",
          "note": "三格，壁挂安装"
        },
        {
          "category": "家具",
          "item": "医疗废物桶50L",
          "quantity": "1",
          "specification": "320×320×450",
          "note": "一般废弃物"
        },
        {
          "category": "家具",
          "item": "普通废物桶20L",
          "quantity": "1",
          "specification": "300×200×350",
          "note": "可放置于清创车/治疗车上"
        },
        {
          "category": "家具",
          "item": "锐器盒11L",
          "quantity": "1",
          "specification": "450×450×50",
          "note": "缝合、清创操作使用"
        },
        {
          "category": "家具",
          "item": "医护升降圆凳",
          "quantity": "1",
          "specification": "550×550×850",
          "note": "家属短时陪护安抚"
        },
        {
          "category": "家具",
          "item": "患者服务面板/床头面板",
          "quantity": "1",
          "specification": "1600×200×450",
          "note": "集成医气、电源、呼叫、数据接口"
        },
        {
          "category": "家具",
          "item": "儿童安全防撞护墙板",
          "quantity": "1",
          "specification": "1800×20×900",
          "note": "床头及床侧墙面"
        },
        {
          "category": "医疗设备",
          "item": "清创/换药治疗车，2抽",
          "quantity": "1",
          "specification": "750×500×900",
          "note": "放清创包、敷料、缝合材料"
        },
        {
          "category": "医疗设备",
          "item": "器械托盘车",
          "quantity": "1",
          "specification": "600×450×850",
          "note": "清创器械临时摆放"
        },
        {
          "category": "医疗设备",
          "item": "氧气流量计",
          "quantity": "2",
          "specification": "150×60×170",
          "note": "接入服务面板"
        },
        {
          "category": "医疗设备",
          "item": "空气流量计",
          "quantity": "1",
          "specification": "150×60×170",
          "note": "接入服务面板"
        },
        {
          "category": "医疗设备",
          "item": "负压吸引适配器",
          "quantity": "1",
          "specification": "120×60×120",
          "note": "接入服务面板"
        },
        {
          "category": "医疗设备",
          "item": "吸引瓶",
          "quantity": "1",
          "specification": "120×120×250",
          "note": "与吸引瓶支架配套"
        },
        {
          "category": "医疗设备",
          "item": "吸引瓶支架",
          "quantity": "1",
          "specification": "160×120×180",
          "note": "壁挂或面板安装"
        },
        {
          "category": "医疗设备",
          "item": "移动输液架",
          "quantity": "1",
          "specification": "500×500×1200-2200",
          "note": "高度可调"
        },
        {
          "category": "医疗设备",
          "item": "单通道输液泵",
          "quantity": "1",
          "specification": "150×200×180",
          "note": "可选，用于输液/镇痛观察"
        },
        {
          "category": "医疗设备",
          "item": "患儿生命体征监护仪",
          "quantity": "1",
          "specification": "360×280×300",
          "note": "可选，按操作风险配置"
        },
        {
          "category": "医疗设备",
          "item": "壁挂诊断套装",
          "quantity": "1",
          "specification": "250×100×300",
          "note": "可选"
        },
        {
          "category": "医疗设备",
          "item": "顶装单头检查灯",
          "quantity": "1",
          "specification": "700×700×1200",
          "note": "清创、缝合照明"
        },
        {
          "category": "医疗设备",
          "item": "儿童约束带/固定带",
          "quantity": "1",
          "specification": "400×300×80",
          "note": "柔性固定，需家属知情配合"
        },
        {
          "category": "医疗设备",
          "item": "局麻/缝合小器械包",
          "quantity": "1",
          "specification": "400×300×120",
          "note": "镊、剪、持针器等"
        },
        {
          "category": "医疗设备",
          "item": "清创冲洗装置/冲洗壶",
          "quantity": "1",
          "specification": "300×200×250",
          "note": "用于创面冲洗"
        },
        {
          "category": "医疗设备",
          "item": "冷藏药品冰箱150L",
          "quantity": "1",
          "specification": "600×600×850",
          "note": "可选，台下安装"
        }
      ],
      "notes": [
        "1. 所有设备和材料需符合国家医用相关标准，确保安全卫生。",
        "2. 尺寸可根据实际空间需求进行适当调整，但需保证功能完整性 。",
        "3. 建议选用易清洁、耐消毒、环保的材料和设备。",
        "4. 定期对设备进行维护保养，确保正常运行。",
        "5. 本清单可根据实际诊疗需求进行补充和调整。"
      ],
      "rawAddedLines": [
        "图3.x清创处置室示意图（图片来源：网络图片）",
        "图3.x清创处置室三维示意见图（图片来源：笔者自绘）",
        "清创处理室",
        "图3.x清创处理室平面图（图片来源：笔者自绘）",
        "房间名称",
        "清创处理室",
        "一、建筑与装修要求",
        "项目类别",
        "详细规格/技术标准",
        "单位",
        "参考标准",
        "备注说明",
        "空间尺寸",
        "开间×进深：4500×4500 mm；面积：20m²；净高：不小于2.8m",
        "项",
        "医用建筑设计规范",
        "儿童清创建议不小于14㎡",
        "墙面装修",
        "墙面采用可擦洗丙烯酸涂料;局部设医用抗菌墙板1500mm高",
        "项",
        "GB 50333-2013",
        "抗菌、易清洁、耐消毒",
        "顶棚装修",
        "可擦洗石膏板吊顶，平整、防尘、防霉；铝合金阴角线",
        "项",
        "GB 50333-2013",
        "吸声、抗菌、防火",
        "地面装修",
        "防滑无缝医用PVC卷材，热焊接缝，150mm上翻踢脚",
        "项",
        "GB 50333-2013",
        "防滑、耐磨、易清洁",
        "门工程",
        "1.5扇门或双开门，门净宽不小于1400mm；可设观察窗并可锁闭",
        "樘",
        "急诊通行要求",
        "防夹手、易清洁",
        "窗工程",
        "中空Low-E玻璃，内置百叶/医用窗帘",
        "m²",
        "实际诊疗需求",
        "隔热、隐私保护",
        "安全隐私",
        "轨道式医用防霉隔帘",
        "套",
        "医用建筑设计规范",
        "可伸缩、易清洁",
        "洗手设施",
        "配备医用洗手盆及相关配件",
        "套",
        "GB 50333-2013",
        "防溅、易消毒",
        "二、装备与设施清单",
        "项目类别",
        "物品名称",
        "数量",
        "规格 (L×W×H/mm)",
        "备注说明",
        "家具",
        "儿童诊疗/清创处置床",
        "1",
        "550×550×850",
        "家属短时陪护安抚",
        "陪护椅",
        "1",
        "1800×600×850",
        "用于备物、记录、清创准备",
        "医护操作台",
        "1",
        "1200×550×850",
        "可调层板，放置耗材",
        "台下储物柜",
        "1",
        "900×350×700",
        "儿童用药及小器械管理",
        "壁挂带锁药品/器械柜",
        "1",
        "3000×2200",
        "保护患儿隐私",
        "床位隔帘",
        "1",
        "250×100×140",
        "三格，壁挂安装",
        "医疗废物桶50L",
        "1",
        "320×320×450",
        "一般废弃物",
        "普通废物桶20L",
        "1",
        "300×200×350",
        "可放置于清创车/治疗车上",
        "锐器盒11L",
        "1",
        "450×450×50",
        "缝合、清创操作使用",
        "医护升降圆凳",
        "1",
        "550×550×850",
        "家属短时陪护安抚",
        "患者服务面板/床头面板",
        "1",
        "1600×200×450",
        "集成医气、电源、呼叫、数据接口",
        "儿童安全防撞护墙板",
        "1",
        "1800×20×900",
        "床头及床侧墙面",
        "医疗设备",
        "清创/换药治疗车，2抽",
        "1",
        "750×500×900",
        "放清创包、敷料、缝合材料",
        "器械托盘车",
        "1",
        "600×450×850",
        "清创器械临时摆放",
        "氧气流量计",
        "2",
        "150×60×170",
        "接入服务面板",
        "空气流量计",
        "1",
        "150×60×170",
        "接入服务面板",
        "负压吸引适配器",
        "1",
        "120×60×120",
        "接入服务面板",
        "吸引瓶",
        "1",
        "120×120×250",
        "与吸引瓶支架配套",
        "吸引瓶支架",
        "1",
        "160×120×180",
        "壁挂或面板安装",
        "移动输液架",
        "1",
        "500×500×1200-2200",
        "高度可调",
        "单通道输液泵",
        "1",
        "150×200×180",
        "可选，用于输液/镇痛观察",
        "患儿生命体征监护仪",
        "1",
        "360×280×300",
        "可选，按操作风险配置",
        "壁挂诊断套装",
        "1",
        "250×100×300",
        "可选",
        "顶装单头检查灯",
        "1",
        "700×700×1200",
        "清创、缝合照明",
        "儿童约束带/固定带",
        "1",
        "400×300×80",
        "柔性固定，需家属知情配合",
        "局麻/缝合小器械包",
        "1",
        "400×300×120",
        "镊、剪、持针器等",
        "清创冲洗装置/冲洗壶",
        "1",
        "300×200×250",
        "用于创面冲洗",
        "冷藏药品冰箱150L",
        "1",
        "600×600×850",
        "可选，台下安装",
        "备注说明",
        "1. 所有设备和材料需符合国家医用相关标准，确保安全卫生。",
        "2. 尺寸可根据实际空间需求进行适当调整，但需保证功能完整性 。",
        "3. 建议选用易清洁、耐消毒、环保的材料和设备。",
        "4. 定期对设备进行维护保养，确保正常运行。",
        "5. 本清单可根据实际诊疗需求进行补充和调整。"
      ],
      "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
      "sourceIssues": [
        "原稿装备表中“儿童诊疗/清创处置床”等条目疑似存在列位错移；完整保留原表，待编审回看源表后再固化型号与尺寸。"
      ]
    }
  },
  {
    "id": "ed_double",
    "dept": "急诊",
    "name": "双人急诊诊室",
    "type": "emergency",
    "priority": "P0",
    "summary": "双人急诊诊室审图重点包括诊室开间尺寸、诊室使用面积、室内净高控制等内容；依据《综合医院建筑设计标准》GB 51039-2014第5.2.4条；《综合医院建筑设计标准》GB 51039-2014第5.1.9条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/急诊/行为示意图/双人诊室new.png",
      "docs/materials/2026.7.6/急诊/轴测/双人.png",
      "docs/materials/2026.7.6/急诊/CAD/7.6_急诊集合_t3.dwg",
      "docs/materials/2026.7.6/急诊/模型/急诊双人诊室轴剖.skp"
    ],
    "preview": "assets/img/previews/ed_double.jpg",
    "rules": [
      "area",
      "handwash",
      "privacy",
      "child"
    ],
    "siteModel": "models/viewer.html?scene=er-double",
    "siteModelName": "3D交互信息模型（双人急诊诊室·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "双人急诊诊室审图重点包括诊室开间尺寸、诊室使用面积、室内净高控制等内容；依据《综合医院建筑设计标准》GB 51039-2014第5.2.4条；《综合医院建筑设计标准》GB 51039-2014第5.1.9条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "诊室开间尺寸：双人诊查室的开间净尺寸不应小于3.00m。",
      "诊室使用面积：双人诊查室使用面积不应小于12.00m²。",
      "室内净高控制：诊查室不宜低于2.60m。"
    ],
    "docReview": [
      "空间模数与净空 / 诊室开间尺寸：需满足两张诊察床及急救推车平行的宽度，建议开间净尺寸放大至3.60m至4.00m。",
      "空间模数与净空 / 诊室使用面积：考虑到儿童急诊一患双陪护特征，双人诊室建议使用面积扩大至15.00m²至18.00m²，并留出直径大于1.50m的推车回转空间。",
      "空间模数与净空 / 室内净高控制：为缓解患儿压抑感并容纳顶部悬挂式检查灯具及隔帘轨道，室内吊顶净高建议设定为2.80m。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "诊室开间尺寸",
        "requirement": "双人诊查室的开间净尺寸不应小于3.00m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.2.4条",
        "suggestion": "需满足两张诊察床及急救推车平行的宽度，建议开间净尺寸放大至3.60m至4.00m。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "诊室使用面积",
        "requirement": "双人诊查室使用面积不应小于12.00m²。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.2.4条",
        "suggestion": "考虑到儿童急诊一患双陪护特征，双人诊室建议使用面积扩大至15.00m²至18.00m²，并留出直径大于1.50m的推车回转空间。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "室内净高控制",
        "requirement": "诊查室不宜低于2.60m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.9条",
        "suggestion": "为缓解患儿压抑感并容纳顶部悬挂式检查灯具及隔帘轨道，室内吊顶净高建议设定为2.80m。"
      }
    ],
    "glbModel": "glb/er-double-section.glb",
    "glbModelDisabled": true,
    "glbModelStatus": "逐房间复核标记为尺度/游离构件异常，待重新归零导出后启用",
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 23,
      "priority": "P0",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 25,
      "finalStatus": "部分完成",
      "finalRequirement": "B 位退出门区；隔帘默认收拢；校正洗手、柜体和锐器盒坐标。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）",
    "glbModelDisabledReason": "2026-07-13 GLB 包围核查发现尺度、原点或游离构件异常；程序场景保留，清理并统一米制重导前禁用实景切换。",
    "glbAuditStatus": "隔离待重导"
  },
  {
    "id": "ed_infusion",
    "dept": "急诊",
    "name": "输液室",
    "type": "ward",
    "priority": "P0",
    "summary": "输液室审图重点包括输液椅排距与陪护空间、婴儿车专属收纳凹槽、天轨悬挂荷载与净高等内容；依据《综合医院建筑设计标准》GB 51039-2014第5.2.6条；《综合医院建筑设计标准》GB 51039-2014第5.1.1条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/急诊/行为示意图/输液室.png",
      "docs/materials/2026.7.6/急诊/行为示意图/输液室02.png",
      "docs/materials/2026.7.6/急诊/轴测/输液轴测.png",
      "docs/materials/2026.7.6/急诊/CAD/7.6_急诊集合_t3.dwg",
      "docs/materials/2026.7.13/急诊/轴测/输液室01.png"
    ],
    "preview": "assets/img/previews/ed_infusion.jpg",
    "rules": [
      "area",
      "handwash",
      "child",
      "infection"
    ],
    "siteModel": "models/viewer.html?scene=er-infusion",
    "siteModelName": "3D交互信息模型（输液室·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "输液室审图重点包括输液椅排距与陪护空间、婴儿车专属收纳凹槽、天轨悬挂荷载与净高等内容；依据《综合医院建筑设计标准》GB 51039-2014第5.2.6条；《综合医院建筑设计标准》GB 51039-2014第5.1.1条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "输液椅排距与陪护空间：儿科候诊区面积应按不小于2㎡/人设计。",
      "婴儿车专属收纳凹槽：医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
      "天轨悬挂荷载与净高：医疗用房的室内净高不宜低于2.60m。建筑结构设计应满足医疗设备、悬挂装置等对荷载及安装的要求。",
      "带输液架疏散净宽：疏散走道、疏散出口的净宽度应满足人员安全疏散的要求。",
      "疏散门零门槛与外开：疏散出口门、疏散走道中的门应向疏散方向开启，且不应设置门槛。",
      "装修材料高阻燃标准：医疗建筑内部装修材料的燃烧性能等级不应低于A级，部分部位不应低于B1级。"
    ],
    "docReview": [
      "空间模数与净空 / 输液椅排距与陪护空间：考虑到儿童输液“一患双陪护”的刚性需求，输液椅排与排之间的净宽必须大于或等于1.50m，确保两名家长并排就坐且不阻挡中央护士巡视通道。",
      "空间模数与净空 / 婴儿车专属收纳凹槽：必须在主输液区外围的非流线干道上，沿墙面退让设计深度大于或等于1.00m的“婴儿推车及折叠营地车专属停靠带”，严禁推车堵塞输液室疏散主轴。",
      "空间模数与净空 / 天轨悬挂荷载与净高：输液室必须满铺矩阵式输液天轨系统。室内吊顶完成面净高建议设定为2.80m。图纸必须提供天轨系统在顶板上的受力钢骨架预埋节点大样图。",
      "防火分隔与应急 / 带输液架疏散净宽：输液患儿在火灾逃生时举着输液瓶或拖拽落地输液架，极易发生羁绊摔倒。输液大厅主疏散走道净宽必须实打实大于或等于3.00m。",
      "防火分隔与应急 / 疏散门零门槛与外开：输液室主出口及通向室外或楼梯间的疏散门必须向外平开，门洞净宽大于或等于1.50m。门下地面必须绝对零门槛平接，确保推着落地输液架的家长能顺畅逃离。",
      "防火分隔与应急 / 装修材料高阻燃标准：输液大厅面积大且人员极度密集，吊顶及顶棚必须采用A级不燃材料（如金属吸音板）。墙面适儿化软包及卡通树脂板必须由厂家出具B1级以上的阻燃检测合格报告。",
      "感控设施与边界 / 配液中心视线与全封闭：输液室核心的“配药室/穿刺台”必须为全封闭玻璃物理隔断，严防家属抢夺药物。穿刺台操作面与患儿坐面需形成高低差，便于护士在坐姿下完成头皮针穿刺。",
      "感控设施与边界 / 传染病物理隔离输液区：输液大厅内部必须硬性切分出一块拥有独立物理隔断与独立排风的“隔离输液区”（针对水痘、流感患儿），切断交叉感染飞沫传播途径。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "输液椅排距与陪护空间",
        "requirement": "儿科候诊区面积应按不小于2㎡/人设计。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.2.6条",
        "suggestion": "考虑到儿童输液“一患双陪护”的刚性需求，输液椅排与排之间的净宽必须大于或等于1.50m，确保两名家长并排就坐且不阻挡中央护士巡视通道。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "婴儿车专属收纳凹槽",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.1条",
        "suggestion": "必须在主输液区外围的非流线干道上，沿墙面退让设计深度大于或等于1.00m的“婴儿推车及折叠营地车专属停靠带”，严禁推车堵塞输液室疏散主轴。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "天轨悬挂荷载与净高",
        "requirement": "医疗用房的室内净高不宜低于2.60m。建筑结构设计应满足医疗设备、悬挂装置等对荷载及安装的要求。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.9条及第4.3.2条",
        "suggestion": "输液室必须满铺矩阵式输液天轨系统。室内吊顶完成面净高建议设定为2.80m。图纸必须提供天轨系统在顶板上的受力钢骨架预埋节点大样图。"
      },
      {
        "dimension": "防火分隔与应急",
        "focus": "带输液架疏散净宽",
        "requirement": "疏散走道、疏散出口的净宽度应满足人员安全疏散的要求。",
        "source": "《建筑防火通用规范》GB 55037-2022第7.1.4条",
        "suggestion": "输液患儿在火灾逃生时举着输液瓶或拖拽落地输液架，极易发生羁绊摔倒。输液大厅主疏散走道净宽必须实打实大于或等于3.00m。"
      },
      {
        "dimension": "防火分隔与应急",
        "focus": "疏散门零门槛与外开",
        "requirement": "疏散出口门、疏散走道中的门应向疏散方向开启，且不应设置门槛。",
        "source": "《建筑防火通用规范》GB 55037-2022第7.2.1条",
        "suggestion": "输液室主出口及通向室外或楼梯间的疏散门必须向外平开，门洞净宽大于或等于1.50m。门下地面必须绝对零门槛平接，确保推着落地输液架的家长能顺畅逃离。"
      },
      {
        "dimension": "防火分隔与应急",
        "focus": "装修材料高阻燃标准",
        "requirement": "医疗建筑内部装修材料的燃烧性能等级不应低于A级，部分部位不应低于B1级。",
        "source": "《建筑防火通用规范》GB 55037-2022第6.1.1条",
        "suggestion": "输液大厅面积大且人员极度密集，吊顶及顶棚必须采用A级不燃材料（如金属吸音板）。墙面适儿化软包及卡通树脂板必须由厂家出具B1级以上的阻燃检测合格报告。"
      },
      {
        "dimension": "感控设施与边界",
        "focus": "配液中心视线与全封闭",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理、洁污路线清楚。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.1条",
        "suggestion": "输液室核心的“配药室/穿刺台”必须为全封闭玻璃物理隔断，严防家属抢夺药物。穿刺台操作面与患儿坐面需形成高低差，便于护士在坐姿下完成头皮针穿刺。"
      },
      {
        "dimension": "感控设施与边界",
        "focus": "传染病物理隔离输液区",
        "requirement": "急诊部应设传染病诊室，并应设在急诊部末端，应设独立出入口，并应附设专用卫生间。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.2.4条",
        "suggestion": "输液大厅内部必须硬性切分出一块拥有独立物理隔断与独立排风的“隔离输液区”（针对水痘、流感患儿），切断交叉感染飞沫传播途径。"
      },
      {
        "dimension": "感控设施与边界",
        "focus": "手卫生终端分布与防溅",
        "requirement": "医疗用房的洗手盆应采用非手动开关，水龙头不应采用充气式，并应采取防止污水外溅的措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第6.2.5条及第6.2.6条",
        "suggestion": "大型输液大厅必须按区域分散配置多组非接触式洗手池（带防溅侧板）。洗手池旁必须标配感应式手部消毒液与擦手纸盒的物理挂位，便于家长处理患儿呕吐物后洗手。"
      },
      {
        "dimension": "室内装修",
        "focus": "地材极端防滑与无缝",
        "requirement": "医疗用房的地面应平整、防滑、易清洁、耐磨、耐腐蚀、不产尘。地面不应设地垄沟。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.10条",
        "suggestion": "输液室地面常有药液滴漏及患儿呕吐物，必须满铺防滑等级R10以上的2.0mm同质透心PVC卷材，上卷上墙15cm形成圆弧阴角。严禁使用遇水极滑的抛光瓷砖。"
      },
      {
        "dimension": "室内装修",
        "focus": "防误触与防跌落屏障",
        "requirement": "儿童诊疗区域的门窗、家具和楼地面等应采取必要的安全保护措施。",
        "source": "《综合医院建设标准》建标110-2021第三十九条（七）",
        "suggestion": "输液室外窗必须安装带钥匙的物理限位器，开启扇缝隙宽度严格锁死在10cm以内。墙面强电插座必须加装带锁的安全防护盖，或安装在1.30m以上高度。"
      },
      {
        "dimension": "室内装修",
        "focus": "阴阳角防撞与立面保护",
        "requirement": "其阴阳角宜做成圆角。有推床或推车通过的门和墙面，应采取防碰撞措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.12条及第39条（三）",
        "suggestion": "室内所有墙角、柱角必须执行半径大于或等于30mm的圆角工艺。沿走道侧墙面0.20m与0.90m处必须满铺防撞护墙板，防止移动落地输液架及婴儿车撞击墙面。"
      },
      {
        "dimension": "视觉干预与心理",
        "focus": "防眩光与色彩舒缓照明",
        "requirement": "医疗用房应采用高显色照明光源，显色指数应大于或等于80。综合医院注重改善患者的就医环境。",
        "source": "《综合医院建筑设计标准》第8.6.2条及《综合医院建设标准》第五条",
        "suggestion": "患儿在输液时长时间仰头视线朝上。天花板严禁设置直射点光源，主照明必须采用防眩光漫反射发光顶棚。建议结合天花板造型定制具有视觉吸引力的卡通发光软膜。"
      },
      {
        "dimension": "视觉干预与心理",
        "focus": "多媒体视觉分散预留",
        "requirement": "综合医院的建设在满足各项功能需要的同时，注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
        "source": "《综合医院建设标准》建标110-2021第五条",
        "suggestion": "建筑墙面高位或天花板下挂区必须预留多媒体电视屏幕的受力挂点，通过播放动画片提供正向的“视觉转移镇痛与情绪安抚”。"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 空间尺寸",
        "requirement": "6-8㎡/输液位；净高：不小于2.8m",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "应满足患儿、陪护及护理巡视空间；原稿参考：医用建筑设计规范"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 墙面装修",
        "requirement": "墙面采用可擦洗丙烯酸涂料;局部设医用抗菌墙板1500mm高",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "抗菌、易清洁、耐消毒；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 顶棚装修",
        "requirement": "可擦洗石膏板吊顶，平整、防尘、防霉；铝合金阴角线",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "吸声、抗菌、防火；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 地面装修",
        "requirement": "推荐2.0mm同质透心医用PVC卷材，热焊接缝，踢脚上翻100-150mm",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "防滑、耐磨、易清洁；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 门工程",
        "requirement": "1500mm双开门",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "门净宽不小于1200mm，防夹手、易清洁；原稿参考：急诊通行要求"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 窗工程",
        "requirement": "中空Low-E玻璃，内置百叶/医用窗帘",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "隔热、隐私保护；原稿参考：实际诊疗需求"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 安全隐私",
        "requirement": "输液位之间宜设半高隔断或软隔帘；插座加儿童安全保护；转角做圆角/防撞处理",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "可伸缩、易清洁；原稿参考：医用建筑设计规范"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 洗手设施",
        "requirement": "配备医用洗手盆及相关配件",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "防溅、易消毒；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "配置复核",
        "focus": "[7.13手册] 家具配置清单",
        "requirement": "儿童输液椅×6（700×750×1100）；陪护椅×6（550×550×850）；应急观察/处置床×1（1800×700×550-750）；护士操作台×1（2400×600×850）；台下储物柜×1（1800×550×850）；壁挂药品/耗材柜×1（1200×350×700）；儿童安抚玩具/绘本架×1（900×350×900）；输液位隔帘×6（1500×2200）；医疗废物桶50L×2（400×400×650）；普通垃圾桶20L×2（320×320×450）；锐器盒及支架×2（270×170×300）；输液轨道×6（1500×40×40）；输液吊架×6（300×300×800-1500）；隔帘轨道×6（1500×40×40）；墙面防撞护墙板×1（按现场尺寸）",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "按真实设备外廓、检修面、门区和操作净空复核；数量为项目手册预设，不替代批准后的设备清单。"
      },
      {
        "dimension": "配置复核",
        "focus": "[7.13手册] 医疗设备配置清单",
        "requirement": "移动输液架×2（500×500×1200-2200）；输液泵×2（150×200×180）；注射泵×2（320×150×120）；儿童生命体征监护仪×1（360×280×300）；氧气流量计×1（150×60×170）；负压吸引适配器×1（120×60×120）；吸引瓶×1（120×120×250）；吸引瓶支架×1（160×120×180）；治疗车/换药车×2（750×500×900）；抢救车×1（750×500×980）；除颤监护仪×1（300×250×200）；儿童体重秤×1（600×400×120）；冷藏药品冰箱×1（600×600×850）",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "按真实设备外廓、检修面、门区和操作净空复核；数量为项目手册预设，不替代批准后的设备清单。"
      }
    ],
    "glbModel": "glb/er-infusion-01.glb",
    "glbModelDisabled": true,
    "glbModelStatus": "逐房间复核标记为尺度/游离构件异常，待重新归零导出后启用",
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 22,
      "priority": "P0",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 24,
      "finalStatus": "部分完成",
      "finalRequirement": "登记台和成人座椅退出门区；婴儿车避开座椅/主题墙；锐器与洗手分离；设感染输液位。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）",
    "glbModelDisabledReason": "2026-07-13 GLB 包围核查发现尺度、原点或游离构件异常；程序场景保留，清理并统一米制重导前禁用实景切换。",
    "glbAuditStatus": "隔离待重导",
    "manual713": {
      "title": "图3.x输液室示意图（图片来源：网络图片）",
      "overview": "",
      "architecture": [
        {
          "item": "空间尺寸",
          "requirement": "6-8㎡/输液位；净高：不小于2.8m",
          "unit": "项",
          "reference": "医用建筑设计规范",
          "note": "应满足患儿、陪护及护理巡视空间"
        },
        {
          "item": "墙面装修",
          "requirement": "墙面采用可擦洗丙烯酸涂料;局部设医用抗菌墙板1500mm高",
          "unit": "项",
          "reference": "GB 50333-2013",
          "note": "抗菌、易清洁、耐消毒"
        },
        {
          "item": "顶棚装修",
          "requirement": "可擦洗石膏板吊顶，平整、防尘、防霉；铝合金阴角线",
          "unit": "项",
          "reference": "GB 50333-2013",
          "note": "吸声、抗菌、防火"
        },
        {
          "item": "地面装修",
          "requirement": "推荐2.0mm同质透心医用PVC卷材，热焊接缝，踢脚上翻100-150mm",
          "unit": "项",
          "reference": "GB 50333-2013",
          "note": "防滑、耐磨、易清洁"
        },
        {
          "item": "门工程",
          "requirement": "1500mm双开门",
          "unit": "樘",
          "reference": "急诊通行要求",
          "note": "门净宽不小于1200mm，防夹手、易清洁"
        },
        {
          "item": "窗工程",
          "requirement": "中空Low-E玻璃，内置百叶/医用窗帘",
          "unit": "m²",
          "reference": "实际诊疗需求",
          "note": "隔热、隐私保护"
        },
        {
          "item": "安全隐私",
          "requirement": "输液位之间宜设半高隔断或软隔帘；插座加儿童安全保护；转角做圆角/防撞处理",
          "unit": "套",
          "reference": "医用建筑设计规范",
          "note": "可伸缩、易清洁"
        },
        {
          "item": "洗手设施",
          "requirement": "配备医用洗手盆及相关配件",
          "unit": "套",
          "reference": "GB 50333-2013",
          "note": "防溅、易消毒"
        }
      ],
      "equipment": [
        {
          "category": "家具",
          "item": "儿童输液椅",
          "quantity": "6",
          "specification": "700×750×1100",
          "note": "可调靠背，带扶手"
        },
        {
          "category": "家具",
          "item": "陪护椅",
          "quantity": "6",
          "specification": "550×550×850",
          "note": "每输液位1把"
        },
        {
          "category": "家具",
          "item": "应急观察/处置床",
          "quantity": "1",
          "specification": "1800×700×550-750",
          "note": "用于不适患儿平卧观察"
        },
        {
          "category": "家具",
          "item": "护士操作台",
          "quantity": "1",
          "specification": "2400×600×850",
          "note": "用于核对、穿刺准备、记录"
        },
        {
          "category": "家具",
          "item": "台下储物柜",
          "quantity": "1",
          "specification": "1800×550×850",
          "note": "放置输液耗材"
        },
        {
          "category": "家具",
          "item": "壁挂药品/耗材柜",
          "quantity": "1",
          "specification": "1200×350×700",
          "note": "带锁，分区管理"
        },
        {
          "category": "家具",
          "item": "儿童安抚玩具/绘本架",
          "quantity": "1",
          "specification": "900×350×900",
          "note": "儿童友好配置，可选"
        },
        {
          "category": "家具",
          "item": "输液位隔帘",
          "quantity": "6",
          "specification": "1500×2200",
          "note": "保护隐私，按现场调整"
        },
        {
          "category": "家具",
          "item": "医疗废物桶50L",
          "quantity": "2",
          "specification": "400×400×650",
          "note": "脚踏式或感应式"
        },
        {
          "category": "家具",
          "item": "普通垃圾桶20L",
          "quantity": "2",
          "specification": "320×320×450",
          "note": "一般废弃物"
        },
        {
          "category": "家具",
          "item": "锐器盒及支架",
          "quantity": "2",
          "specification": "270×170×300",
          "note": "穿刺区及治疗车配置"
        },
        {
          "category": "家具",
          "item": "输液轨道",
          "quantity": "6",
          "specification": "1500×40×40",
          "note": "每输液位1套，顶装"
        },
        {
          "category": "家具",
          "item": "输液吊架",
          "quantity": "6",
          "specification": "300×300×800-1500",
          "note": "与轨道配套"
        },
        {
          "category": "家具",
          "item": "隔帘轨道",
          "quantity": "6",
          "specification": "1500×40×40",
          "note": "按输液位布置"
        },
        {
          "category": "家具",
          "item": "墙面防撞护墙板",
          "quantity": "1",
          "specification": "按现场尺寸",
          "note": "输液椅背墙及转角区域"
        },
        {
          "category": "医疗设备",
          "item": "移动输液架",
          "quantity": "2",
          "specification": "500×500×1200-2200",
          "note": "备用及临时加位使用"
        },
        {
          "category": "医疗设备",
          "item": "输液泵",
          "quantity": "2",
          "specification": "150×200×180",
          "note": "高风险药或特殊患儿使用"
        },
        {
          "category": "医疗设备",
          "item": "注射泵",
          "quantity": "2",
          "specification": "320×150×120",
          "note": "儿科精准给药，可选"
        },
        {
          "category": "医疗设备",
          "item": "儿童生命体征监护仪",
          "quantity": "1",
          "specification": "360×280×300",
          "note": "应急观察床旁配置"
        },
        {
          "category": "医疗设备",
          "item": "氧气流量计",
          "quantity": "1",
          "specification": "150×60×170",
          "note": "应急观察床旁"
        },
        {
          "category": "医疗设备",
          "item": "负压吸引适配器",
          "quantity": "1",
          "specification": "120×60×120",
          "note": "应急备用"
        },
        {
          "category": "医疗设备",
          "item": "吸引瓶",
          "quantity": "1",
          "specification": "120×120×250",
          "note": "与吸引支架配套"
        },
        {
          "category": "医疗设备",
          "item": "吸引瓶支架",
          "quantity": "1",
          "specification": "160×120×180",
          "note": "墙挂或面板安装"
        },
        {
          "category": "医疗设备",
          "item": "治疗车/换药车",
          "quantity": "2",
          "specification": "750×500×900",
          "note": "穿刺、巡回护理使用"
        },
        {
          "category": "医疗设备",
          "item": "抢救车",
          "quantity": "1",
          "specification": "750×500×980",
          "note": "输液反应、过敏反应应急"
        },
        {
          "category": "医疗设备",
          "item": "除颤监护仪",
          "quantity": "1",
          "specification": "300×250×200",
          "note": "可与急诊抢救区就近配置"
        },
        {
          "category": "医疗设备",
          "item": "儿童体重秤",
          "quantity": "1",
          "specification": "600×400×120",
          "note": "儿科用药剂量核对"
        },
        {
          "category": "医疗设备",
          "item": "冷藏药品冰箱",
          "quantity": "1",
          "specification": "600×600×850",
          "note": "可选，需温度监测"
        }
      ],
      "notes": [
        "1. 所有设备和材料需符合国家医用相关标准，确保安全卫生。",
        "2. 尺寸可根据实际空间需求进行适当调整，但需保证功能完整性 。",
        "3. 建议选用易清洁、耐消毒、环保的材料和设备。",
        "4. 定期对设备进行维护保养，确保正常运行。",
        "5. 本清单可根据实际诊疗需求进行补充和调整。"
      ],
      "rawAddedLines": [
        "图3.x输液室示意图（图片来源：网络图片）",
        "图3.x 输液室布局01三维示意见图（图片来源：笔者自绘）",
        "图3.x 输液室布局02三维示意见图（图片来源：笔者自绘）",
        "输液室01",
        "图3.x 输液室01平面布局图（图片来源：笔者自绘）",
        "房间名称",
        "输液室02",
        "图3.x 输液室02平面布局图（图片来源：笔者自绘）",
        "房间名称",
        "输液室",
        "一、建筑与装修要求",
        "项目类别",
        "详细规格/技术标准",
        "单位",
        "参考标准",
        "备注说明",
        "空间尺寸",
        "6-8㎡/输液位；净高：不小于2.8m",
        "项",
        "医用建筑设计规范",
        "应满足患儿、陪护及护理巡视空间",
        "墙面装修",
        "墙面采用可擦洗丙烯酸涂料;局部设医用抗菌墙板1500mm高",
        "项",
        "GB 50333-2013",
        "抗菌、易清洁、耐消毒",
        "顶棚装修",
        "可擦洗石膏板吊顶，平整、防尘、防霉；铝合金阴角线",
        "项",
        "GB 50333-2013",
        "吸声、抗菌、防火",
        "地面装修",
        "推荐2.0mm同质透心医用PVC卷材，热焊接缝，踢脚上翻100-150mm",
        "项",
        "GB 50333-2013",
        "防滑、耐磨、易清洁",
        "门工程",
        "1500mm双开门",
        "樘",
        "急诊通行要求",
        "门净宽不小于1200mm，防夹手、易清洁",
        "窗工程",
        "中空Low-E玻璃，内置百叶/医用窗帘",
        "m²",
        "实际诊疗需求",
        "隔热、隐私保护",
        "安全隐私",
        "输液位之间宜设半高隔断或软隔帘；插座加儿童安全保护；转角做圆角/防撞处理",
        "套",
        "医用建筑设计规范",
        "可伸缩、易清洁",
        "洗手设施",
        "配备医用洗手盆及相关配件",
        "套",
        "GB 50333-2013",
        "防溅、易消毒",
        "二、装备与设施清单",
        "项目类别",
        "物品名称",
        "数量",
        "规格 (L×W×H/mm)",
        "备注说明",
        "家具",
        "儿童输液椅",
        "6",
        "700×750×1100",
        "可调靠背，带扶手",
        "陪护椅",
        "6",
        "550×550×850",
        "每输液位1把",
        "应急观察/处置床",
        "1",
        "1800×700×550-750",
        "用于不适患儿平卧观察",
        "护士操作台",
        "1",
        "2400×600×850",
        "用于核对、穿刺准备、记录",
        "台下储物柜",
        "1",
        "1800×550×850",
        "放置输液耗材",
        "壁挂药品/耗材柜",
        "1",
        "1200×350×700",
        "带锁，分区管理",
        "儿童安抚玩具/绘本架",
        "1",
        "900×350×900",
        "儿童友好配置，可选",
        "输液位隔帘",
        "6",
        "1500×2200",
        "保护隐私，按现场调整",
        "医疗废物桶50L",
        "2",
        "400×400×650",
        "脚踏式或感应式",
        "普通垃圾桶20L",
        "2",
        "320×320×450",
        "一般废弃物",
        "锐器盒及支架",
        "2",
        "270×170×300",
        "穿刺区及治疗车配置",
        "输液轨道",
        "6",
        "1500×40×40",
        "每输液位1套，顶装",
        "输液吊架",
        "6",
        "300×300×800-1500",
        "与轨道配套",
        "隔帘轨道",
        "6",
        "1500×40×40",
        "按输液位布置",
        "墙面防撞护墙板",
        "1",
        "按现场尺寸",
        "输液椅背墙及转角区域",
        "医疗设备",
        "移动输液架",
        "2",
        "500×500×1200-2200",
        "备用及临时加位使用",
        "输液泵",
        "2",
        "150×200×180",
        "高风险药或特殊患儿使用",
        "注射泵",
        "2",
        "320×150×120",
        "儿科精准给药，可选",
        "儿童生命体征监护仪",
        "1",
        "360×280×300",
        "应急观察床旁配置",
        "氧气流量计",
        "1",
        "150×60×170",
        "应急观察床旁",
        "负压吸引适配器",
        "1",
        "120×60×120",
        "应急备用",
        "吸引瓶",
        "1",
        "120×120×250",
        "与吸引支架配套",
        "吸引瓶支架",
        "1",
        "160×120×180",
        "墙挂或面板安装",
        "治疗车/换药车",
        "2",
        "750×500×900",
        "穿刺、巡回护理使用",
        "抢救车",
        "1",
        "750×500×980",
        "输液反应、过敏反应应急",
        "除颤监护仪",
        "1",
        "300×250×200",
        "可与急诊抢救区就近配置",
        "儿童体重秤",
        "1",
        "600×400×120",
        "儿科用药剂量核对",
        "冷藏药品冰箱",
        "1",
        "600×600×850",
        "可选，需温度监测",
        "备注说明",
        "1. 所有设备和材料需符合国家医用相关标准，确保安全卫生。",
        "2. 尺寸可根据实际空间需求进行适当调整，但需保证功能完整性 。",
        "3. 建议选用易清洁、耐消毒、环保的材料和设备。",
        "4. 定期对设备进行维护保养，确保正常运行。",
        "5. 本清单可根据实际诊疗需求进行补充和调整。"
      ],
      "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
      "sourceIssues": []
    }
  },
  {
    "id": "ed_nebulization",
    "dept": "急诊",
    "name": "雾化治疗室",
    "type": "treatment",
    "priority": "P1",
    "summary": "雾化治疗室审图重点包括独立空间与物理封闭、雾化座排距与陪护模数、婴儿车外置收纳盲区等内容；依据《综合医院建筑设计标准》GB 51039-2014第5.1.1条；《综合医院建筑设计标准》GB 51039-2014第5.2.6条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/急诊/行为示意图/雾化治疗室.png",
      "docs/materials/2026.7.6/急诊/CAD/7.6_急诊集合_t3.dwg",
      "docs/materials/2026.7.13/急诊/行为示意图/雾化治疗室.png",
      "docs/materials/2026.7.13/急诊/轴测/雾化治疗室.png"
    ],
    "preview": "assets/img/previews/ed_nebulization.jpg",
    "rules": [
      "area",
      "handwash",
      "child",
      "infection"
    ],
    "siteModel": "models/viewer.html?scene=er-nebulization",
    "siteModelName": "3D交互信息模型（雾化治疗室·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "同质透心PVC或橡胶卷材，防滑、耐磨、耐消毒；卷材热焊接，无缝或少缝；踢脚上翻150 mm并圆弧收口。",
    "docFacts": [
      "独立空间与物理封闭：医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理、洁污路线清楚。",
      "雾化座排距与陪护模数：面积应按不小于2㎡/人设计。",
      "婴儿车外置收纳盲区：医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
      "疏散通道净宽与无障碍：疏散走道、疏散出口的净宽度应满足人员安全疏散的要求。",
      "门槛平接与紧急脱离：疏散出口门、疏散走道中的门应向疏散方向开启，且不应设置门槛。",
      "装修与隔板材料阻燃：医疗建筑内部装修材料的燃烧性能等级不应低于A级，部分部位不应低于B1级。"
    ],
    "docReview": [
      "空间模数与净空 / 独立空间与物理封闭：雾化治疗会产生大量携带病毒的气溶胶，严禁在急诊大厅开敞区设置雾化座。必须设置带有实体隔墙与闭门器的独立房间，实现物理空间彻底隔离。",
      "空间模数与净空 / 雾化座排距与陪护模数：需满足“患儿坐姿+家长侧坐环抱”的刚性空间需求。雾化座椅排间距必须大于或等于1.50m，单人位面宽不应小于0.80m，预留家长辅助戴面罩的操作空间。",
      "空间模数与净空 / 婴儿车外置收纳盲区：雾化室内座位密集，平面图纸必须在雾化室大门外侧的非主干道走廊上，硬性划定一块深度大于或等于1.00m的“婴儿车集中停放区”，严禁推车入室导致拥堵。",
      "防火分隔与应急 / 疏散通道净宽与无障碍：剔除座椅及家长站立空间后，雾化室内通向大门的主疏散通道净宽必须大于或等于1.50m。疏散门必须向外平开，严禁采用内开门导致慌乱逃生时的人群堵塞。",
      "防火分隔与应急 / 门槛平接与紧急脱离：雾化室大门地面必须绝对零门槛平接处理，确保抱起患儿飞奔的家长不会发生脚下羁绊跌倒。",
      "防火分隔与应急 / 装修与隔板材料阻燃：室内吊顶及顶棚必须采用A级不燃材料。墙面抗菌板以及座位之间的亚克力/PC透明防飞沫隔板，必须由厂家提供B1级以上的阻燃检测合格报告，严禁使用普通易燃塑料隔板。",
      "感控设施与边界 / 座位间物理防飞沫屏障：相邻雾化座位之间必须设置由桌面延伸至距地高度1.50m的透明钢化玻璃或亚克力物理隔板，隔板进深需超越患儿面部至少0.50m，直接阻断气溶胶横向飘散。",
      "感控设施与边界 / 深水槽与咳痰清理区：雾化极易诱发患儿剧烈咳嗽与呕吐。室内必须配置至少一组深水槽（深度大于0.25m）洗手池，池边墙面必须铺设高1.20m的抗菌易洁板，并就近配置感应手消与防臭带盖污物桶。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "独立空间与物理封闭",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理、洁污路线清楚。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.1条",
        "suggestion": "雾化治疗会产生大量携带病毒的气溶胶，严禁在急诊大厅开敞区设置雾化座。必须设置带有实体隔墙与闭门器的独立房间，实现物理空间彻底隔离。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "雾化座排距与陪护模数",
        "requirement": "面积应按不小于2㎡/人设计。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.2.6条",
        "suggestion": "需满足“患儿坐姿+家长侧坐环抱”的刚性空间需求。雾化座椅排间距必须大于或等于1.50m，单人位面宽不应小于0.80m，预留家长辅助戴面罩的操作空间。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "婴儿车外置收纳盲区",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.1条",
        "suggestion": "雾化室内座位密集，平面图纸必须在雾化室大门外侧的非主干道走廊上，硬性划定一块深度大于或等于1.00m的“婴儿车集中停放区”，严禁推车入室导致拥堵。"
      },
      {
        "dimension": "防火分隔与应急",
        "focus": "疏散通道净宽与无障碍",
        "requirement": "疏散走道、疏散出口的净宽度应满足人员安全疏散的要求。",
        "source": "《建筑防火通用规范》GB 55037-2022第7.1.4条",
        "suggestion": "剔除座椅及家长站立空间后，雾化室内通向大门的主疏散通道净宽必须大于或等于1.50m。疏散门必须向外平开，严禁采用内开门导致慌乱逃生时的人群堵塞。"
      },
      {
        "dimension": "防火分隔与应急",
        "focus": "门槛平接与紧急脱离",
        "requirement": "疏散出口门、疏散走道中的门应向疏散方向开启，且不应设置门槛。",
        "source": "《建筑防火通用规范》GB 55037-2022第7.2.1条",
        "suggestion": "雾化室大门地面必须绝对零门槛平接处理，确保抱起患儿飞奔的家长不会发生脚下羁绊跌倒。"
      },
      {
        "dimension": "防火分隔与应急",
        "focus": "装修与隔板材料阻燃",
        "requirement": "医疗建筑内部装修材料的燃烧性能等级不应低于A级，部分部位不应低于B1级。",
        "source": "《建筑防火通用规范》GB 55037-2022第6.1.1条",
        "suggestion": "室内吊顶及顶棚必须采用A级不燃材料。墙面抗菌板以及座位之间的亚克力/PC透明防飞沫隔板，必须由厂家提供B1级以上的阻燃检测合格报告，严禁使用普通易燃塑料隔板。"
      },
      {
        "dimension": "感控设施与边界",
        "focus": "座位间物理防飞沫屏障",
        "requirement": "医疗用房应通风良好。采取有效措施防止交叉感染。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第7.1.1条",
        "suggestion": "相邻雾化座位之间必须设置由桌面延伸至距地高度1.50m的透明钢化玻璃或亚克力物理隔板，隔板进深需超越患儿面部至少0.50m，直接阻断气溶胶横向飘散。"
      },
      {
        "dimension": "感控设施与边界",
        "focus": "深水槽与咳痰清理区",
        "requirement": "医疗用房的洗手盆应采用非手动开关，水龙头不应采用充气式，并应采取防止污水外溅的措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第6.2.5条及第6.2.6条",
        "suggestion": "雾化极易诱发患儿剧烈咳嗽与呕吐。室内必须配置至少一组深水槽（深度大于0.25m）洗手池，池边墙面必须铺设高1.20m的抗菌易洁板，并就近配置感应手消与防臭带盖污物桶。"
      },
      {
        "dimension": "室内装修",
        "focus": "多媒体视线工程学预留",
        "requirement": "综合医院注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
        "source": "《综合医院建设标准》建标110-2021第五条",
        "suggestion": "雾化高度依赖动画片吸引注意力以保持患儿深呼吸。建筑墙面必须预留电视屏幕挂点，屏幕中心标高应控制在1.00m至1.20m之间，匹配坐姿患儿平视视线，严防高位悬挂导致患儿仰头呛咳。"
      },
      {
        "dimension": "室内装修",
        "focus": "抗应激色彩与防眩光",
        "requirement": "医疗用房应采用高显色照明光源，显色指数应大于或等于80。综合医院注重改善患者的就医环境。",
        "source": "《综合医院建筑设计标准》第8.6.2条及《综合医院建设标准》第五条",
        "suggestion": "雾化室墙面宜采用明快的低饱和度暖色调（如暖黄、浅绿）树脂板。天花板照明必须全部采用带防眩光罩的漫反射光源，避免患儿抬头直视时刺眼。"
      },
      {
        "dimension": "视觉干预与心理",
        "focus": "地材防滑与无缝抗菌",
        "requirement": "医疗用房的地面应平整、防滑、易清洁、耐磨、耐腐蚀、不产尘。地面不应设地垄沟。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.10条",
        "suggestion": "雾化室地面常有药液滴漏与呕吐物，必须满铺防滑等级R10以上的同质透心PVC卷材，上卷上墙15cm形成圆弧阴角，接缝处严格进行热熔无缝焊接处理。"
      },
      {
        "dimension": "视觉干预与心理",
        "focus": "阴阳角与隐形防撞",
        "requirement": "其阴阳角宜做成圆角。有推床或推车通过的门和墙面，应采取防碰撞措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.12条及第39条（三）",
        "suggestion": "室内所有墙角、柱角、隔板边缘必须执行半径大于或等于20mm的圆角打磨或隐形护角包裹工艺。沿走道侧墙面0.20m与0.90m处满铺高强度抗刮树脂防撞带。"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 空间尺寸",
        "requirement": "开间×进深：5600×8400 mm；面积：20m²；净高：不小于2.8m",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "（原稿备注单元格缺失）；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 墙面装修",
        "requirement": "采用抗菌、耐擦洗、耐消毒、光滑不积尘墙面；",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "宜采用浅色、低反光、儿童友好色彩；材料满足阻燃及环保要求。；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 顶棚装修",
        "requirement": "轻钢龙骨防潮石膏板或医疗洁净板吊顶；照明、空调、排风口及空气消毒设施协调布置。",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "检修口避开治疗位正上方，减少落尘风险。；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 地面装修",
        "requirement": "同质透心PVC或橡胶卷材，防滑、耐磨、耐消毒；卷材热焊接，无缝或少缝；踢脚上翻150 mm并圆弧收口。",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "地面与墙面交接便于清洁，避免积尘积液。；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 门工程",
        "requirement": "医用单开外开门或推拉门；门洞净宽按图约1400 mm；设观察窗、防撞板、闭门器和无障碍拉手，开启不影响疏散及转运。",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "若需轮椅或急救转运，门净宽应由建筑专业复核。；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 窗工程",
        "requirement": "中空Low-E玻璃，内置百叶/医用窗帘",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "隔热、隐私保护；原稿参考：实际诊疗需求"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 安全隐私",
        "requirement": "轨道式医用防霉隔帘",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "可伸缩、易清洁；原稿参考：医用建筑设计规范"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 洗手设施",
        "requirement": "配备医用洗手盆及相关配件",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "防溅、易消毒；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "配置复核",
        "focus": "[7.13手册] 家具配置清单",
        "requirement": "雾化治疗椅×7（650×650×850）；陪护椅/观察椅×7（500×520×800）；雾化位隔断/防护挡板×7组（1500×50×1200/1400）；台板/治疗搁板×7（1500×450×750）；医用设备带/墙面功能带×7（按单元定制）；壁挂输液架/输液钩×7（壁挂/轨道式）；护士工作台/书写台×1（约1800×700×750）；医护工作椅×2（500×500×800）；耗材储物高柜/吊柜×1（约900×450×2100）；台下柜/治疗柜×1（约1200×600×850）；移动治疗车/器械车×1（650×450×900）；废物分类桶组×2组（20-50 L/只）",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "按真实设备外廓、检修面、门区和操作净空复核；数量为项目手册预设，不替代批准后的设备清单。"
      },
      {
        "dimension": "配置复核",
        "focus": "[7.13手册] 医疗设备配置清单",
        "requirement": "雾化治疗主机/压缩雾化器×7（300×180×220）；雾化面罩/咬嘴及一次性雾化杯×7套（儿童/成人规格）；空气流量计×7（墙式/设备带接口）；氧气流量计×2（墙式/设备带接口）；吸引装置/负压吸引瓶×2（壁挂/移动式）；脉搏血氧仪×2（便携式）；生命体征监测仪×1（台式/推车式）；便携式氧气瓶/氧气推车×1（按院方标准）；壁挂显示屏×7（≥21 in）；护士工作站电脑及显示器×1（台式/一体机）；打印机/标签打印机×1（桌面型）；护士呼叫/应急呼叫按钮×7+1（墙面/设备带安装）；手卫生用品组合×1套（皂液器、手消、擦手纸、手套盒）；锐器盒×1（5-11 L）；空气消毒机/排风净化设备×1（按房间风量计算）",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "按真实设备外廓、检修面、门区和操作净空复核；数量为项目手册预设，不替代批准后的设备清单。"
      },
      {
        "dimension": "源数据校核",
        "focus": "[7.13手册] 原稿数值疑点",
        "requirement": "原稿同时给出 5600×8400 mm 与 20m²，尺寸乘积为 47.04m²；保留原文，模型不以矛盾面积值作合规判定。",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "待编审确认前标记为“原稿待复核”，不自动生成不合格结论。"
      },
      {
        "dimension": "源数据校核",
        "focus": "[7.13手册] 原稿数值疑点",
        "requirement": "原稿建筑装修表首行缺少备注单元格；解析时补记“原稿备注单元格缺失”，不推测原意。",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "待编审确认前标记为“原稿待复核”，不自动生成不合格结论。"
      }
    ],
    "legacySiteModel": "models/model-real.html?space=resus",
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 24,
      "priority": "P1",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 26,
      "finalStatus": "部分完成",
      "finalRequirement": "配药和污物退出门区；两治疗位保持通道；绑定患儿/陪护；检查隔间门。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）",
    "manual713": {
      "title": "图3.x雾化治疗室示意图（图片来源：笔者自绘）",
      "overview": "同质透心PVC或橡胶卷材，防滑、耐磨、耐消毒；卷材热焊接，无缝或少缝；踢脚上翻150 mm并圆弧收口。",
      "architecture": [
        {
          "item": "空间尺寸",
          "requirement": "开间×进深：5600×8400 mm；面积：20m²；净高：不小于2.8m",
          "unit": "间",
          "reference": "GB 50333-2013",
          "note": "（原稿备注单元格缺失）"
        },
        {
          "item": "墙面装修",
          "requirement": "采用抗菌、耐擦洗、耐消毒、光滑不积尘墙面；",
          "unit": "项",
          "reference": "GB 50333-2013",
          "note": "宜采用浅色、低反光、儿童友好色彩；材料满足阻燃及环保要求。"
        },
        {
          "item": "顶棚装修",
          "requirement": "轻钢龙骨防潮石膏板或医疗洁净板吊顶；照明、空调、排风口及空气消毒设施协调布置。",
          "unit": "项",
          "reference": "GB 50333-2013",
          "note": "检修口避开治疗位正上方，减少落尘风险。"
        },
        {
          "item": "地面装修",
          "requirement": "同质透心PVC或橡胶卷材，防滑、耐磨、耐消毒；卷材热焊接，无缝或少缝；踢脚上翻150 mm并圆弧收口。",
          "unit": "项",
          "reference": "GB 50333-2013",
          "note": "地面与墙面交接便于清洁，避免积尘积液。"
        },
        {
          "item": "门工程",
          "requirement": "医用单开外开门或推拉门；门洞净宽按图约1400 mm；设观察窗、防撞板、闭门器和无障碍拉手，开启不影响疏散及转运。",
          "unit": "樘",
          "reference": "GB 50333-2013",
          "note": "若需轮椅或急救转运，门净宽应由建筑专业复核。"
        },
        {
          "item": "窗工程",
          "requirement": "中空Low-E玻璃，内置百叶/医用窗帘",
          "unit": "m²",
          "reference": "实际诊疗需求",
          "note": "隔热、隐私保护"
        },
        {
          "item": "安全隐私",
          "requirement": "轨道式医用防霉隔帘",
          "unit": "套",
          "reference": "医用建筑设计规范",
          "note": "可伸缩、易清洁"
        },
        {
          "item": "洗手设施",
          "requirement": "配备医用洗手盆及相关配件",
          "unit": "套",
          "reference": "GB 50333-2013",
          "note": "防溅、易消毒"
        }
      ],
      "equipment": [
        {
          "category": "家具",
          "item": "雾化治疗椅",
          "quantity": "7",
          "specification": "650×650×850",
          "note": "儿童使用，带扶手，可擦洗，靠背宜可调"
        },
        {
          "category": "家具",
          "item": "陪护椅/观察椅",
          "quantity": "7",
          "specification": "500×520×800",
          "note": "供家属陪同或短时观察，布置不得占用中部通道。"
        },
        {
          "category": "家具",
          "item": "雾化位隔断/防护挡板",
          "quantity": "7组",
          "specification": "1500×50×1200/1400",
          "note": "每位分隔，边角圆滑，表面耐消毒，兼顾观察视线。"
        },
        {
          "category": "家具",
          "item": "台板/治疗搁板",
          "quantity": "7",
          "specification": "1500×450×750",
          "note": "供雾化器、耗材和个人物品临时放置。"
        },
        {
          "category": "家具",
          "item": "医用设备带/墙面功能带",
          "quantity": "7",
          "specification": "按单元定制",
          "note": "配置电源、医疗空气/氧气接口、弱电或呼叫预留；接口按院方系统确定。"
        },
        {
          "category": "家具",
          "item": "壁挂输液架/输液钩",
          "quantity": "7",
          "specification": "壁挂/轨道式",
          "note": "图示位于设备带，可兼顾输液和雾化治疗。"
        },
        {
          "category": "家具",
          "item": "护士工作台/书写台",
          "quantity": "1",
          "specification": "约1800×700×750",
          "note": "位于入口右侧，用于登记、处方核对和治疗记录。"
        },
        {
          "category": "家具",
          "item": "医护工作椅",
          "quantity": "2",
          "specification": "500×500×800",
          "note": "与护士工作台配套，易清洁、可移动。"
        },
        {
          "category": "家具",
          "item": "耗材储物高柜/吊柜",
          "quantity": "1",
          "specification": "约900×450×2100",
          "note": "存放面罩、雾化杯和消毒用品；必要时带锁管理。"
        },
        {
          "category": "家具",
          "item": "台下柜/治疗柜",
          "quantity": "1",
          "specification": "约1200×600×850",
          "note": "靠近洗手及护理区布置，放置常用耗材，台面耐水。"
        },
        {
          "category": "家具",
          "item": "移动治疗车/器械车",
          "quantity": "1",
          "specification": "650×450×900",
          "note": "用于药品、雾化杯和面罩耗材转运；带刹车。"
        },
        {
          "category": "家具",
          "item": "废物分类桶组",
          "quantity": "2组",
          "specification": "20-50 L/只",
          "note": "按图在洗手区和护理工作区各设1组：普通垃圾、医疗污物；脚踏带盖。"
        },
        {
          "category": "医疗设备",
          "item": "雾化治疗主机/压缩雾化器",
          "quantity": "7",
          "specification": "300×180×220",
          "note": "每位1台，建议低噪声、外壳可消毒；可与医疗空气接口配套。"
        },
        {
          "category": "医疗设备",
          "item": "雾化面罩/咬嘴及一次性雾化杯",
          "quantity": "7套",
          "specification": "儿童/成人规格",
          "note": "按日用量另配耗材；一人一用或按院感要求处置。"
        },
        {
          "category": "医疗设备",
          "item": "空气流量计",
          "quantity": "7",
          "specification": "墙式/设备带接口",
          "note": "对应雾化位配置；参考复苏床位气体流量计配置原则。"
        },
        {
          "category": "医疗设备",
          "item": "氧气流量计",
          "quantity": "2",
          "specification": "墙式/设备带接口",
          "note": "供急救或低氧患儿备用，不作为常规雾化气源。"
        },
        {
          "category": "医疗设备",
          "item": "吸引装置/负压吸引瓶",
          "quantity": "2",
          "specification": "壁挂/移动式",
          "note": "用于痰液、呕吐物等应急处理；参考复苏床位吸引接口配置原则。"
        },
        {
          "category": "医疗设备",
          "item": "脉搏血氧仪",
          "quantity": "2",
          "specification": "便携式",
          "note": "治疗中观察血氧饱和度和脉率，配置儿童探头。"
        },
        {
          "category": "医疗设备",
          "item": "生命体征监测仪",
          "quantity": "1",
          "specification": "台式/推车式",
          "note": "异常患儿短时观察使用，含血压、血氧、心率监测。"
        },
        {
          "category": "医疗设备",
          "item": "便携式氧气瓶/氧气推车",
          "quantity": "1",
          "specification": "按院方标准",
          "note": "备用供氧，设置防倾倒固定措施。"
        },
        {
          "category": "医疗设备",
          "item": "壁挂显示屏",
          "quantity": "7",
          "specification": "≥21 in",
          "note": "图示每位设置，用于叫号、宣教或雾化治疗计时。"
        },
        {
          "category": "医疗设备",
          "item": "护士工作站电脑及显示器",
          "quantity": "1",
          "specification": "台式/一体机",
          "note": "登记、医嘱核对和治疗记录使用，配置数据点。"
        },
        {
          "category": "医疗设备",
          "item": "打印机/标签打印机",
          "quantity": "1",
          "specification": "桌面型",
          "note": "用于打印标签、治疗单或宣教资料。"
        },
        {
          "category": "医疗设备",
          "item": "护士呼叫/应急呼叫按钮",
          "quantity": "7+1",
          "specification": "墙面/设备带安装",
          "note": "每雾化位1个，护理台设应急呼叫复位或显示。"
        },
        {
          "category": "医疗设备",
          "item": "手卫生用品组合",
          "quantity": "1套",
          "specification": "皂液器、手消、擦手纸、手套盒",
          "note": "设于洗手盆及护理区；参考手卫生分配器配置原则。"
        },
        {
          "category": "医疗设备",
          "item": "锐器盒",
          "quantity": "1",
          "specification": "5-11 L",
          "note": "药品配制或针具处理备用，固定在护理区或治疗车。"
        },
        {
          "category": "医疗设备",
          "item": "空气消毒机/排风净化设备",
          "quantity": "1",
          "specification": "按房间风量计算",
          "note": "雾化治疗产生气溶胶，宜加强通风换气和空气消毒；参数由暖通专业校核。"
        }
      ],
      "notes": [
        "1. 所有设备和材料需符合国家医用相关标准，确保安全卫生。",
        "2. 尺寸可根据实际空间需求进行适当调整，但需保证功能完整性 。",
        "3. 建议选用易清洁、耐消毒、环保的材料和设备。",
        "4. 定期对设备进行维护保养，确保正常运行。",
        "5. 本清单可根据实际诊疗需求进行补充和调整。",
        "图3.x雾化治疗室配置清单（图片来源：笔者自绘）"
      ],
      "rawAddedLines": [
        "图3.x雾化治疗室示意图（图片来源：笔者自绘）",
        "图3.x雾化治疗室三维示意见图（图片来源：笔者自绘）",
        "雾化治疗室平面布置图3.x",
        "雾化治疗室",
        "图3.x雾化治疗室平面布局图（图片来源：笔者自绘）",
        "房间名称",
        "雾化治疗室",
        "一、建筑与装修要求",
        "项目类别",
        "详细规格/技术标准",
        "单位",
        "参考标准",
        "备注说明",
        "空间尺寸",
        "开间×进深：5600×8400 mm；面积：20m²；净高：不小于2.8m",
        "间",
        "GB 50333-2013",
        "墙面装修",
        "采用抗菌、耐擦洗、耐消毒、光滑不积尘墙面；",
        "项",
        "GB 50333-2013",
        "宜采用浅色、低反光、儿童友好色彩；材料满足阻燃及环保要求。",
        "顶棚装修",
        "轻钢龙骨防潮石膏板或医疗洁净板吊顶；照明、空调、排风口及空气消毒设施协调布置。",
        "项",
        "GB 50333-2013",
        "检修口避开治疗位正上方，减少落尘风险。",
        "地面装修",
        "同质透心PVC或橡胶卷材，防滑、耐磨、耐消毒；卷材热焊接，无缝或少缝；踢脚上翻150 mm并圆弧收口。",
        "项",
        "GB 50333-2013",
        "地面与墙面交接便于清洁，避免积尘积液。",
        "门工程",
        "医用单开外开门或推拉门；门洞净宽按图约1400 mm；设观察窗、防撞板、闭门器和无障碍拉手，开启不影响疏散及转运。",
        "樘",
        "GB 50333-2013",
        "若需轮椅或急救转运，门净宽应由建筑专业复核。",
        "窗工程",
        "中空Low-E玻璃，内置百叶/医用窗帘",
        "m²",
        "实际诊疗需求",
        "隔热、隐私保护",
        "安全隐私",
        "轨道式医用防霉隔帘",
        "套",
        "医用建筑设计规范",
        "可伸缩、易清洁",
        "洗手设施",
        "配备医用洗手盆及相关配件",
        "套",
        "GB 50333-2013",
        "防溅、易消毒",
        "二、装备与设施清单",
        "项目类别",
        "物品名称",
        "数量",
        "规格 (L×W×H/mm)",
        "备注说明",
        "家具",
        "雾化治疗椅",
        "7",
        "650×650×850",
        "儿童使用，带扶手，可擦洗，靠背宜可调",
        "陪护椅/观察椅",
        "7",
        "500×520×800",
        "供家属陪同或短时观察，布置不得占用中部通道。",
        "雾化位隔断/防护挡板",
        "7组",
        "1500×50×1200/1400",
        "每位分隔，边角圆滑，表面耐消毒，兼顾观察视线。",
        "台板/治疗搁板",
        "7",
        "1500×450×750",
        "供雾化器、耗材和个人物品临时放置。",
        "医用设备带/墙面功能带",
        "7",
        "按单元定制",
        "配置电源、医疗空气/氧气接口、弱电或呼叫预留；接口按院方系统确定。",
        "壁挂输液架/输液钩",
        "7",
        "壁挂/轨道式",
        "图示位于设备带，可兼顾输液和雾化治疗。",
        "护士工作台/书写台",
        "1",
        "约1800×700×750",
        "位于入口右侧，用于登记、处方核对和治疗记录。",
        "医护工作椅",
        "2",
        "500×500×800",
        "与护士工作台配套，易清洁、可移动。",
        "耗材储物高柜/吊柜",
        "1",
        "约900×450×2100",
        "存放面罩、雾化杯和消毒用品；必要时带锁管理。",
        "台下柜/治疗柜",
        "1",
        "约1200×600×850",
        "靠近洗手及护理区布置，放置常用耗材，台面耐水。",
        "移动治疗车/器械车",
        "1",
        "650×450×900",
        "用于药品、雾化杯和面罩耗材转运；带刹车。",
        "废物分类桶组",
        "2组",
        "20-50 L/只",
        "按图在洗手区和护理工作区各设1组：普通垃圾、医疗污物；脚踏带盖。",
        "医疗设备",
        "雾化治疗主机/压缩雾化器",
        "7",
        "300×180×220",
        "每位1台，建议低噪声、外壳可消毒；可与医疗空气接口配套。",
        "雾化面罩/咬嘴及一次性雾化杯",
        "7套",
        "儿童/成人规格",
        "按日用量另配耗材；一人一用或按院感要求处置。",
        "空气流量计",
        "7",
        "墙式/设备带接口",
        "对应雾化位配置；参考复苏床位气体流量计配置原则。",
        "氧气流量计",
        "2",
        "墙式/设备带接口",
        "供急救或低氧患儿备用，不作为常规雾化气源。",
        "吸引装置/负压吸引瓶",
        "2",
        "壁挂/移动式",
        "用于痰液、呕吐物等应急处理；参考复苏床位吸引接口配置原则。",
        "脉搏血氧仪",
        "2",
        "便携式",
        "治疗中观察血氧饱和度和脉率，配置儿童探头。",
        "生命体征监测仪",
        "1",
        "台式/推车式",
        "异常患儿短时观察使用，含血压、血氧、心率监测。",
        "便携式氧气瓶/氧气推车",
        "1",
        "按院方标准",
        "备用供氧，设置防倾倒固定措施。",
        "壁挂显示屏",
        "7",
        "≥21 in",
        "图示每位设置，用于叫号、宣教或雾化治疗计时。",
        "护士工作站电脑及显示器",
        "1",
        "台式/一体机",
        "登记、医嘱核对和治疗记录使用，配置数据点。",
        "打印机/标签打印机",
        "1",
        "桌面型",
        "用于打印标签、治疗单或宣教资料。",
        "护士呼叫/应急呼叫按钮",
        "7+1",
        "墙面/设备带安装",
        "每雾化位1个，护理台设应急呼叫复位或显示。",
        "手卫生用品组合",
        "1套",
        "皂液器、手消、擦手纸、手套盒",
        "设于洗手盆及护理区；参考手卫生分配器配置原则。",
        "锐器盒",
        "1",
        "5-11 L",
        "药品配制或针具处理备用，固定在护理区或治疗车。",
        "空气消毒机/排风净化设备",
        "1",
        "按房间风量计算",
        "雾化治疗产生气溶胶，宜加强通风换气和空气消毒；参数由暖通专业校核。",
        "备注说明",
        "1. 所有设备和材料需符合国家医用相关标准，确保安全卫生。",
        "2. 尺寸可根据实际空间需求进行适当调整，但需保证功能完整性 。",
        "3. 建议选用易清洁、耐消毒、环保的材料和设备。",
        "4. 定期对设备进行维护保养，确保正常运行。",
        "5. 本清单可根据实际诊疗需求进行补充和调整。",
        "图3.x雾化治疗室配置清单（图片来源：笔者自绘）"
      ],
      "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
      "sourceIssues": [
        "原稿同时给出 5600×8400 mm 与 20m²，尺寸乘积为 47.04m²；保留原文，模型不以矛盾面积值作合规判定。",
        "原稿建筑装修表首行缺少备注单元格；解析时补记“原稿备注单元格缺失”，不推测原意。"
      ]
    }
  },
  {
    "id": "ed_negative",
    "dept": "急诊",
    "name": "隔离抢救室",
    "type": "resus",
    "priority": "P0",
    "summary": "空气传播疾病及不明原因呼吸道感染患儿的隔离、筛查取样与应急处置空间；设置前室、独立卫生间、负压与独立排风，并以压差监测和高效过滤形成可核查的感染控制链。",
    "assets": [
      "docs/materials/2026.7.6/急诊/CAD/7.6_急诊集合_t3.dwg",
      "docs/materials/2026.7.6/急诊/模型/隔离抢救室.skp",
      "docs/materials/2026.7.13/急诊/轴测/隔离抢救室.png"
    ],
    "rules": [
      "area",
      "privacy",
      "child",
      "infection"
    ],
    "siteModel": "models/viewer.html?scene=er-negative",
    "siteModelName": "3D交互信息模型（负压隔离室·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "隔离抢救室是应对结核、流感等空气传播疾病及不明原因呼吸道感染患儿的核心感控节点。通过精密气流控制系统使室内气压低于外部，搭配独立排风与HEPA高效过滤，防止污染空气外溢。该封闭空间集物理隔离、筛查取样及应急处置于一体，净面积≥18㎡（含≥6㎡前室），设独立卫生间与前室，采用圆角耐消毒家具及儿童专用设备，执行二级+防护、废物双层封装规范，兼顾感染阻断与患儿安抚需求（见图3.x）。",
    "docFacts": [
      "项目手册预设：开间×进深 4800×6000 mm，面积 29m²，净高不小于 2.8m。",
      "功能底线：净面积不小于 18m²，其中前室不小于 6m²，并设独立卫生间。",
      "负压、独立排风、HEPA 高效过滤、压差监测应形成连续可验证系统。",
      "门净宽不小于 1400mm；PVC 地材热焊无缝并上翻 150mm。",
      "家具圆角、耐擦洗消毒；隔离废物双层封装，防护级别按院感流程复核。"
    ],
    "docReview": [
      "空间平面与流线 / 气锁缓冲间强制设置：隔离室入口必须设置独立的物理缓冲间（气锁室）。缓冲间净深度必须大于或等于1.50m，以容纳抢救平车或仪器车短暂停留，严防内外门同时开启。",
      "空间平面与流线 / 独立专用卫生间配置：负压室内必须附设患儿专用的独立卫生间，包含淋浴与如厕功能，彻底切断患儿前往公共区域的排泄物交叉感染途径。",
      "空间平面与流线 / 洁污双走廊物理分流：隔离室平面必须采取“双门双通道”布局。患儿及污染废弃物由外侧“污物走廊”进出；医护人员由内侧“洁净走廊”经缓冲间进入，实现绝对分流。",
      "防火分隔与封堵 / 绝对物理防火分隔：负压隔离室作为极高风险的独立单元，其四周墙体必须砌筑至建筑结构真顶（楼板底），且必须为耐火极限不低于2.00h的实体防火墙，严禁采用轻质隔断。",
      "防火分隔与封堵 / 穿墙孔洞全密实防火封堵：建筑图纸必须标明：所有穿越隔离室墙体的排风管、水管、桥架孔洞，必须使用防火膨胀模块及气密胶进行“双面全密实封堵”，杜绝任何漏风与漏烟缝隙。",
      "防火分隔与封堵 / 零门槛与应急推床宽度：气密门开启后的净宽必须大于或等于1.20m。门下禁止设置任何用于密封的凸起门槛，必须采用门扇底部的“下沉式自动扫地胶条”来实现平地密封，确保推床无障碍进入。",
      "建筑门窗与封闭 / 气密门与闭门器构造：缓冲间内外两道门必须为带有下沉式密封胶条的医用气密门，并配置机械闭门器。审图时需核对门体是否具备紧急情况下的“互锁解除”物理按键，防抢救延误。",
      "建筑门窗与封闭 / 外窗全密闭与不可开启：负压室外窗必须为双层中空钢化玻璃全封闭固定窗，严禁设置任何可开启扇，彻底杜绝污染空气通过自然风压逸散至院区室外。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间平面与流线",
        "focus": "气锁缓冲间强制设置",
        "requirement": "负压隔离病房应设缓冲间，并应设传递窗。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.5.4条",
        "suggestion": "隔离室入口必须设置独立的物理缓冲间（气锁室）。缓冲间净深度必须大于或等于1.50m，以容纳抢救平车或仪器车短暂停留，严防内外门同时开启。"
      },
      {
        "dimension": "空间平面与流线",
        "focus": "独立专用卫生间配置",
        "requirement": "急诊部应在末端设传染病诊室，应设独立出入口，并应附设专用卫生间。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.2.4条",
        "suggestion": "负压室内必须附设患儿专用的独立卫生间，包含淋浴与如厕功能，彻底切断患儿前往公共区域的排泄物交叉感染途径。"
      },
      {
        "dimension": "空间平面与流线",
        "focus": "洁污双走廊物理分流",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理、洁污路线清楚。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.1条",
        "suggestion": "隔离室平面必须采取“双门双通道”布局。患儿及污染废弃物由外侧“污物走廊”进出；医护人员由内侧“洁净走廊”经缓冲间进入，实现绝对分流。"
      },
      {
        "dimension": "防火分隔与封堵",
        "focus": "绝对物理防火分隔",
        "requirement": "医院中的手术部、急诊部、重症监护室、贵重精密医疗设备用房等，应采用防火隔墙和不燃楼板与其他部位分隔。",
        "source": "《建筑防火通用规范》GB 55037-2022第4.3.1条",
        "suggestion": "负压隔离室作为极高风险的独立单元，其四周墙体必须砌筑至建筑结构真顶（楼板底），且必须为耐火极限不低于2.00h的实体防火墙，严禁采用轻质隔断。"
      },
      {
        "dimension": "防火分隔与封堵",
        "focus": "穿墙孔洞全密实防火封堵",
        "requirement": "建筑内各类管线穿过防火墙、防火隔墙、楼板的孔洞应采用防火封堵材料封堵，封堵的耐火性能不应低于相应分隔构件的耐火性能。",
        "source": "《建筑防火通用规范》GB 55037-2022第6.3.1条",
        "suggestion": "建筑图纸必须标明：所有穿越隔离室墙体的排风管、水管、桥架孔洞，必须使用防火膨胀模块及气密胶进行“双面全密实封堵”，杜绝任何漏风与漏烟缝隙。"
      },
      {
        "dimension": "防火分隔与封堵",
        "focus": "零门槛与应急推床宽度",
        "requirement": "通向推床的门净宽不应小于1.10m。疏散出口门应为平开门或在火灾时具有平开功能的门，且不应设置门槛。",
        "source": "《综合医院建筑设计标准》第5.1.4条及《建筑防火通用规范》第7.2.1条",
        "suggestion": "气密门开启后的净宽必须大于或等于1.20m。门下禁止设置任何用于密封的凸起门槛，必须采用门扇底部的“下沉式自动扫地胶条”来实现平地密封，确保推床无障碍进入。"
      },
      {
        "dimension": "建筑门窗与封闭",
        "focus": "气密门与闭门器构造",
        "requirement": "相邻相通不同洁净度房间的门应设闭门器。半限制区、限制区内的门窗应有良好的密闭性。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.5.4条及第5.1.8条",
        "suggestion": "缓冲间内外两道门必须为带有下沉式密封胶条的医用气密门，并配置机械闭门器。审图时需核对门体是否具备紧急情况下的“互锁解除”物理按键，防抢救延误。"
      },
      {
        "dimension": "建筑门窗与封闭",
        "focus": "外窗全密闭与不可开启",
        "requirement": "负压隔离病房应设缓冲间，建筑内部装修不应擅自减少、改动、拆除、遮挡消防设施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.5.4条",
        "suggestion": "负压室外窗必须为双层中空钢化玻璃全封闭固定窗，严禁设置任何可开启扇，彻底杜绝污染空气通过自然风压逸散至院区室外。"
      },
      {
        "dimension": "建筑门窗与封闭",
        "focus": "污物瞬时传递窗预留",
        "requirement": "负压隔离病房应设缓冲间，并应设传递窗。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.5.4条",
        "suggestion": "在隔离室与外部污物走廊的共用墙体上，必须嵌入安装机械互锁式双扉传递窗，专用于传递血样及医疗垃圾，减少大门开启频次。"
      },
      {
        "dimension": "室内装修与防渗",
        "focus": "墙地顶六面体无缝构造",
        "requirement": "医疗用房的地面、踢脚板、墙裙、墙面、顶棚应便于清扫或冲洗。其阴阳角宜做成圆角。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.12条",
        "suggestion": "房间的地面、墙面、吊顶必须形成一个“无缝密封舱”。地面采用同质透心卷材热熔焊接并上卷上墙；吊顶必须为全密闭硬质抗菌板（严禁使用矿棉板或铝扣板），所有板缝必须打防霉硅酮结构胶。"
      },
      {
        "dimension": "室内装修与防渗",
        "focus": "防溢地漏与水封深度",
        "requirement": "卫生间、污洗间、洗涤等有水区域应设地漏。地漏应采用带防干涸水封的地漏，水封深度不得小于50mm。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第6.2.7条",
        "suggestion": "隔离室及附属卫生间的地漏必须是带防干涸水封的医疗密闭地漏，彻底阻断下水道中的病毒气溶胶通过负压抽吸倒灌入室内。"
      },
      {
        "dimension": "室内装修与防渗",
        "focus": "适儿化立面极限防撞",
        "requirement": "有推床或推车通过的门和墙面，应采取防碰撞措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.12条",
        "suggestion": "考虑到隔离患儿极易产生烦躁与破坏性行为，室内墙面0.20m至1.20m高度必须满铺高强度抗刮擦抗菌树脂板，阳角圆弧半径必须大于或等于20mm。"
      },
      {
        "dimension": "视觉干预与心理",
        "focus": "全景监护与探视观察窗",
        "requirement": "护理单元应设护士站并与治疗室、办公用房邻近。",
        "source": "《儿童医院建设标准》第28条及《综合医院建设标准》第五条",
        "suggestion": "为缓解患儿独自被隔离的幽闭恐惧，走廊侧墙体应设置大面积全透明密闭观察窗。窗外需预留家属探视站位，并结合建筑隔墙预留双向语音对讲系统的安装位。"
      },
      {
        "dimension": "视觉干预与心理",
        "focus": "抗应激视觉软化设计",
        "requirement": "综合医院的建设在满足各项功能需要的同时，注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
        "source": "《综合医院建设标准》建标110-2021第五条",
        "suggestion": "隔离室内墙面及天花板严禁采用纯白冷色调。建议在密闭吊顶内嵌发光柔和的虚拟蓝天灯，或在抗污墙板上定制低饱和度的卡通图案，降低空间压抑感。"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 空间尺寸",
        "requirement": "开间×进深：4800×6000 mm；面积：29m²；净高：不小于2.8m",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "承担抢救功能，建议结合设备展开适当放大；原稿参考：医用建筑设计规范"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 墙面装修",
        "requirement": "墙面采用可擦洗丙烯酸涂料；洗手盆及溅水区采用6mm树脂板或防溅瓷砖；床头区设防撞护墙板",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "抗菌、易清洁、耐消毒；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 顶棚装修",
        "requirement": "可擦洗石膏板吊顶，平整密闭；铝合金阴角线；预留检查灯、风口、检修口和压差监测",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "吸声、抗菌、防火；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 地面装修",
        "requirement": "防滑无缝医用PVC卷材，热焊接缝，150mm上翻踢脚",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "防滑、耐磨、易清洁；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 门工程",
        "requirement": "铝合金/安全玻璃门，1.5扇或双开形式，门净宽不小于1400mm",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "防夹手、易清洁；原稿参考：适儿化设计导则"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 窗工程",
        "requirement": "中空Low-E玻璃，内置百叶/医用窗帘",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "隔热、隐私保护；原稿参考：实际诊疗需求"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 安全隐私",
        "requirement": "轨道式医用防霉隔帘",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "可伸缩、易清洁；原稿参考：医用建筑设计规范"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 洗手设施",
        "requirement": "配备医用洗手盆及相关配件",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "防溅、易消毒；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "配置复核",
        "focus": "[7.13手册] 家具配置清单",
        "requirement": "诊疗/恢复推床×1（2100×750×600-850）；访客/患者椅×1（550×550×850）；床位隔帘×1（3000×2200）；床位隔帘轨道×1（3000×40×40）；一次性手套分配器×1（250×100×140）；普通废物桶20L×1（320×320×450）；医疗废物桶20-50L×1（400×400×650）；锐器盒及支架11L×1（300×200×350）",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "按真实设备外廓、检修面、门区和操作净空复核；数量为项目手册预设，不替代批准后的设备清单。"
      },
      {
        "dimension": "配置复核",
        "focus": "[7.13手册] 医疗设备配置清单",
        "requirement": "氧气流量计×2（150×60×170）；空气流量计×2（150×60×170）；患者服务面板/墙面服务面板×1（1800×200×450）；负压压差显示/报警装置×1（200×80×160）；负压吸引适配器×2（120×60×120）；吸引瓶×2（120×120×250）；吸引瓶支架×2（160×120×180）；患者监护仪支架×1（300×250×300）；重症生理监护仪×1（360×280×300）；移动输液架×1（500×500×1200-2200）；单通道输液泵×1（150×200×180）；注射泵×1（320×150×120）；单头顶装检查灯×1（700×700×1200）；两步脚踏凳×1（450×400×400）；隔离转运抢救车×1（750×500×980）；便携吸引器×1（400×250×300）；移动空气消毒/净化设备×1（600×500×900）",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "按真实设备外廓、检修面、门区和操作净空复核；数量为项目手册预设，不替代批准后的设备清单。"
      }
    ],
    "preview": "assets/img/previews/ed_cpr.jpg",
    "glbModel": "glb/er-negative-pressure.glb",
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 16,
      "priority": "P0",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 18,
      "finalStatus": "部分完成",
      "finalRequirement": "陪护避开洗手盆、护士退出卫生间；校正传递窗和柜体；GLB 重导出前以程序化场景为准。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）",
    "glbAuditStatus": "尺度接近，保留并继续核对原点、构件命名与拾取",
    "manual713": {
      "title": "隔离抢救室",
      "overview": "隔离抢救室是应对结核、流感等空气传播疾病及不明原因呼吸道感染患儿的核心感控节点。通过精密气流控制系统使室内气压低于外部，搭配独立排风与HEPA高效过滤，防止污染空气外溢。该封闭空间集物理隔离、筛查取样及应急处置于一体，净面积≥18㎡（含≥6㎡前室），设独立卫生间与前室，采用圆角耐消毒家具及儿童专用设备，执行二级+防护、废物双层封装规范，兼顾感染阻断与患儿安抚需求（见图3.x）。",
      "architecture": [
        {
          "item": "空间尺寸",
          "requirement": "开间×进深：4800×6000 mm；面积：29m²；净高：不小于2.8m",
          "unit": "项",
          "reference": "医用建筑设计规范",
          "note": "承担抢救功能，建议结合设备展开适当放大"
        },
        {
          "item": "墙面装修",
          "requirement": "墙面采用可擦洗丙烯酸涂料；洗手盆及溅水区采用6mm树脂板或防溅瓷砖；床头区设防撞护墙板",
          "unit": "项",
          "reference": "GB 50333-2013",
          "note": "抗菌、易清洁、耐消毒"
        },
        {
          "item": "顶棚装修",
          "requirement": "可擦洗石膏板吊顶，平整密闭；铝合金阴角线；预留检查灯、风口、检修口和压差监测",
          "unit": "项",
          "reference": "GB 50333-2013",
          "note": "吸声、抗菌、防火"
        },
        {
          "item": "地面装修",
          "requirement": "防滑无缝医用PVC卷材，热焊接缝，150mm上翻踢脚",
          "unit": "项",
          "reference": "GB 50333-2013",
          "note": "防滑、耐磨、易清洁"
        },
        {
          "item": "门工程",
          "requirement": "铝合金/安全玻璃门，1.5扇或双开形式，门净宽不小于1400mm",
          "unit": "樘",
          "reference": "适儿化设计导则",
          "note": "防夹手、易清洁"
        },
        {
          "item": "窗工程",
          "requirement": "中空Low-E玻璃，内置百叶/医用窗帘",
          "unit": "m²",
          "reference": "实际诊疗需求",
          "note": "隔热、隐私保护"
        },
        {
          "item": "安全隐私",
          "requirement": "轨道式医用防霉隔帘",
          "unit": "套",
          "reference": "医用建筑设计规范",
          "note": "可伸缩、易清洁"
        },
        {
          "item": "洗手设施",
          "requirement": "配备医用洗手盆及相关配件",
          "unit": "套",
          "reference": "GB 50333-2013",
          "note": "防溅、易消毒"
        }
      ],
      "equipment": [
        {
          "category": "家具",
          "item": "诊疗/恢复推床",
          "quantity": "1",
          "specification": "2100×750×600-850",
          "note": "急诊急性治疗、观察和隔离抢救"
        },
        {
          "category": "家具",
          "item": "访客/患者椅",
          "quantity": "1",
          "specification": "550×550×850",
          "note": "可选，按院感要求使用"
        },
        {
          "category": "家具",
          "item": "床位隔帘",
          "quantity": "1",
          "specification": "3000×2200",
          "note": "保护隐私，按现场调整"
        },
        {
          "category": "家具",
          "item": "床位隔帘轨道",
          "quantity": "1",
          "specification": "3000×40×40",
          "note": "顶装，按现场调整"
        },
        {
          "category": "家具",
          "item": "一次性手套分配器",
          "quantity": "1",
          "specification": "250×100×140",
          "note": "壁挂安装"
        },
        {
          "category": "家具",
          "item": "普通废物桶20L",
          "quantity": "1",
          "specification": "320×320×450",
          "note": "脚踏式或感应式"
        },
        {
          "category": "家具",
          "item": "医疗废物桶20-50L",
          "quantity": "1",
          "specification": "400×400×650",
          "note": "隔离医疗废物收集"
        },
        {
          "category": "家具",
          "item": "锐器盒及支架11L",
          "quantity": "1",
          "specification": "300×200×350",
          "note": "壁挂安装"
        },
        {
          "category": "医疗设备",
          "item": "氧气流量计",
          "quantity": "2",
          "specification": "150×60×170",
          "note": "接入患者服务面板"
        },
        {
          "category": "医疗设备",
          "item": "空气流量计",
          "quantity": "2",
          "specification": "150×60×170",
          "note": "接入患者服务面板"
        },
        {
          "category": "医疗设备",
          "item": "患者服务面板/墙面服务面板",
          "quantity": "1",
          "specification": "1800×200×450",
          "note": "集成医气、电源、通信、呼叫"
        },
        {
          "category": "医疗设备",
          "item": "负压压差显示/报警装置",
          "quantity": "1",
          "specification": "200×80×160",
          "note": "显示房间压差状态"
        },
        {
          "category": "医疗设备",
          "item": "负压吸引适配器",
          "quantity": "2",
          "specification": "120×60×120",
          "note": "接入患者服务面板"
        },
        {
          "category": "医疗设备",
          "item": "吸引瓶",
          "quantity": "2",
          "specification": "120×120×250",
          "note": "与吸引瓶支架配套"
        },
        {
          "category": "医疗设备",
          "item": "吸引瓶支架",
          "quantity": "2",
          "specification": "160×120×180",
          "note": "壁挂或服务面板配套"
        },
        {
          "category": "医疗设备",
          "item": "患者监护仪支架",
          "quantity": "1",
          "specification": "300×250×300",
          "note": "墙挂或服务面板安装"
        },
        {
          "category": "医疗设备",
          "item": "重症生理监护仪",
          "quantity": "1",
          "specification": "360×280×300",
          "note": "接数据及应急电源"
        },
        {
          "category": "医疗设备",
          "item": "移动输液架",
          "quantity": "1",
          "specification": "500×500×1200-2200",
          "note": "高度可调"
        },
        {
          "category": "医疗设备",
          "item": "单通道输液泵",
          "quantity": "1",
          "specification": "150×200×180",
          "note": "安装于输液架"
        },
        {
          "category": "医疗设备",
          "item": "注射泵",
          "quantity": "1",
          "specification": "320×150×120",
          "note": "安装于输液架"
        },
        {
          "category": "医疗设备",
          "item": "单头顶装检查灯",
          "quantity": "1",
          "specification": "700×700×1200",
          "note": "LED，接应急电源"
        },
        {
          "category": "医疗设备",
          "item": "两步脚踏凳",
          "quantity": "1",
          "specification": "450×400×400",
          "note": "辅助上下床/操作"
        },
        {
          "category": "医疗设备",
          "item": "隔离转运抢救车",
          "quantity": "1",
          "specification": "750×500×980",
          "note": "可选，隔离急救药品耗材"
        },
        {
          "category": "医疗设备",
          "item": "便携吸引器",
          "quantity": "1",
          "specification": "400×250×300",
          "note": "可选，应急备用"
        },
        {
          "category": "医疗设备",
          "item": "移动空气消毒/净化设备",
          "quantity": "1",
          "specification": "600×500×900",
          "note": "可选，不替代负压通风系统"
        }
      ],
      "notes": [
        "1. 所有设备和材料需符合国家医用相关标准，确保安全卫生。",
        "2. 尺寸可根据实际空间需求进行适当调整，但需保证功能完整性。",
        "3. 建议选用易清洁、耐消毒、环保的材料和设备。",
        "4. 定期对设备进行维护保养，确保正常运行。",
        "5. 本清单可根据实际诊疗需求进行补充和调整。"
      ],
      "rawAddedLines": [
        "隔离抢救室",
        "隔离抢救室是应对结核、流感等空气传播疾病及不明原因呼吸道感染患儿的核心感控节点。通过精密气流控制系统使室内气压低于外部，搭配独立排风与HEPA高效过滤，防止污染空气外溢。该封闭空间集物理隔离、筛查取样及应急处置于一体，净面积≥18㎡（含≥6㎡前室），设独立卫生间与前室，采用圆角耐消毒家具及儿童专用设备，执行二级+防护、废物双层封装规范，兼顾感染阻断与患儿安抚需求（见图3.x）。",
        "图3.x隔离抢救室示意图（图片来源：网络图片）",
        "图3.x隔离抢救室行为示意图（图片来源：笔者自绘）",
        "图3.x 隔离抢救室布局三维示意见图（图片来源：笔者自绘）",
        "房间名称",
        "隔离抢救室",
        "图3.x隔离抢救室平面布局图（图片来源：笔者自绘）",
        "房间名称",
        "隔离抢救室",
        "一、建筑与装修要求",
        "项目类别",
        "详细规格/技术标准",
        "单位",
        "参考标准",
        "备注说明",
        "空间尺寸",
        "开间×进深：4800×6000 mm；面积：29m²；净高：不小于2.8m",
        "项",
        "医用建筑设计规范",
        "承担抢救功能，建议结合设备展开适当放大",
        "墙面装修",
        "墙面采用可擦洗丙烯酸涂料；洗手盆及溅水区采用6mm树脂板或防溅瓷砖；床头区设防撞护墙板",
        "项",
        "GB 50333-2013",
        "抗菌、易清洁、耐消毒",
        "顶棚装修",
        "可擦洗石膏板吊顶，平整密闭；铝合金阴角线；预留检查灯、风口、检修口和压差监测",
        "项",
        "GB 50333-2013",
        "吸声、抗菌、防火",
        "地面装修",
        "防滑无缝医用PVC卷材，热焊接缝，150mm上翻踢脚",
        "项",
        "GB 50333-2013",
        "防滑、耐磨、易清洁",
        "门工程",
        "铝合金/安全玻璃门，1.5扇或双开形式，门净宽不小于1400mm",
        "樘",
        "适儿化设计导则",
        "防夹手、易清洁",
        "窗工程",
        "中空Low-E玻璃，内置百叶/医用窗帘",
        "m²",
        "实际诊疗需求",
        "隔热、隐私保护",
        "安全隐私",
        "轨道式医用防霉隔帘",
        "套",
        "医用建筑设计规范",
        "可伸缩、易清洁",
        "洗手设施",
        "配备医用洗手盆及相关配件",
        "套",
        "GB 50333-2013",
        "防溅、易消毒",
        "二、装备与设施清单",
        "项目类别",
        "物品名称",
        "数量",
        "规格 (L×W×H/mm)",
        "备注说明",
        "家具",
        "诊疗/恢复推床",
        "1",
        "2100×750×600-850",
        "急诊急性治疗、观察和隔离抢救",
        "访客/患者椅",
        "1",
        "550×550×850",
        "可选，按院感要求使用",
        "床位隔帘",
        "1",
        "3000×2200",
        "保护隐私，按现场调整",
        "床位隔帘轨道",
        "1",
        "3000×40×40",
        "顶装，按现场调整",
        "一次性手套分配器",
        "1",
        "250×100×140",
        "壁挂安装",
        "普通废物桶20L",
        "1",
        "320×320×450",
        "脚踏式或感应式",
        "医疗废物桶20-50L",
        "1",
        "400×400×650",
        "隔离医疗废物收集",
        "锐器盒及支架11L",
        "1",
        "300×200×350",
        "壁挂安装",
        "医疗设备",
        "氧气流量计",
        "2",
        "150×60×170",
        "接入患者服务面板",
        "空气流量计",
        "2",
        "150×60×170",
        "接入患者服务面板",
        "患者服务面板/墙面服务面板",
        "1",
        "1800×200×450",
        "集成医气、电源、通信、呼叫",
        "负压压差显示/报警装置",
        "1",
        "200×80×160",
        "显示房间压差状态",
        "负压吸引适配器",
        "2",
        "120×60×120",
        "接入患者服务面板",
        "吸引瓶",
        "2",
        "120×120×250",
        "与吸引瓶支架配套",
        "吸引瓶支架",
        "2",
        "160×120×180",
        "壁挂或服务面板配套",
        "患者监护仪支架",
        "1",
        "300×250×300",
        "墙挂或服务面板安装",
        "重症生理监护仪",
        "1",
        "360×280×300",
        "接数据及应急电源",
        "移动输液架",
        "1",
        "500×500×1200-2200",
        "高度可调",
        "单通道输液泵",
        "1",
        "150×200×180",
        "安装于输液架",
        "注射泵",
        "1",
        "320×150×120",
        "安装于输液架",
        "单头顶装检查灯",
        "1",
        "700×700×1200",
        "LED，接应急电源",
        "两步脚踏凳",
        "1",
        "450×400×400",
        "辅助上下床/操作",
        "隔离转运抢救车",
        "1",
        "750×500×980",
        "可选，隔离急救药品耗材",
        "便携吸引器",
        "1",
        "400×250×300",
        "可选，应急备用",
        "移动空气消毒/净化设备",
        "1",
        "600×500×900",
        "可选，不替代负压通风系统",
        "备注说明",
        "1. 所有设备和材料需符合国家医用相关标准，确保安全卫生。",
        "2. 尺寸可根据实际空间需求进行适当调整，但需保证功能完整性。",
        "3. 建议选用易清洁、耐消毒、环保的材料和设备。",
        "4. 定期对设备进行维护保养，确保正常运行。",
        "5. 本清单可根据实际诊疗需求进行补充和调整。"
      ],
      "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
      "sourceIssues": []
    },
    "sceneInfo": {
      "area": "4.80 × 6.00 m · 净高 2.90m（项目手册预设 29m²）",
      "dims": {
        "def": [
          4.8,
          6,
          2.9
        ],
        "min": [
          4.8,
          6,
          2.8
        ],
        "sugg": [
          4.8,
          6,
          2.9
        ],
        "minLabel": "7.13 手册预设",
        "suggLabel": "信息模型"
      },
      "norms": [
        "净面积≥18m²",
        "前室≥6m²",
        "门净宽≥1400mm",
        "净高≥2.8m"
      ],
      "compliance": [
        "模型 4.80×6.00m、净高 2.90m；前室、独立卫生间、负压排风与备用接口需在场景中逐项可见。"
      ]
    }
  },
  {
    "id": "ed_observe",
    "dept": "急诊",
    "name": "急诊留观室",
    "type": "ward",
    "priority": "P0",
    "summary": "急诊留观室审图重点包括留观床间距与操作界限、婴儿车与杂物专属收纳、室内吊顶完成面净高等内容；依据《综合医院建筑设计标准》GB 51039-2014第5.2.5条；《综合医院建筑设计标准》GB 51039-2014第5.1.1条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/急诊/行为示意图/急诊留观.png",
      "docs/materials/2026.7.6/急诊/轴测/急诊留观室.png",
      "docs/materials/2026.7.6/急诊/CAD/7.6_急诊集合_t3.dwg",
      "docs/materials/2026.7.6/急诊/模型/留观.skp"
    ],
    "preview": "assets/img/previews/ed_observe.jpg",
    "rules": [
      "area",
      "handwash",
      "privacy",
      "child"
    ],
    "siteModel": "models/viewer.html?scene=er-observe",
    "siteModelName": "3D交互信息模型（急诊留观室·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "急诊留观室审图重点包括留观床间距与操作界限、婴儿车与杂物专属收纳、室内吊顶完成面净高等内容；依据《综合医院建筑设计标准》GB 51039-2014第5.2.5条；《综合医院建筑设计标准》GB 51039-2014第5.1.1条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "留观床间距与操作界限：床间距不应小于1.20m。",
      "婴儿车与杂物专属收纳：医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
      "室内吊顶完成面净高：医疗用房的室内净高不宜低于2.60m。",
      "生命通道极限净宽：通向推床的门净宽不应小于1.10m。疏散出口门应为平开门或在火灾时具有平开功能的门，且不应设置门槛。",
      "连床疏散的避难间联动：高层病房楼应在二层及以上的每个病房楼层设置避难间。避难间应靠近疏散楼梯间。",
      "装修材料高阻燃标准：医疗建筑内部装修材料的燃烧性能等级不应低于A级，部分部位不应低于B1级。"
    ],
    "docReview": [
      "空间模数与净空 / 留观床间距与操作界限：考虑到儿童留观“双家属+婴儿车+折叠陪护椅”的极限占用，相邻病床净间距必须放大至1.50m以上，床尾至对侧墙面（或病床）的推床疏散通道净宽必须大于或等于2.00m。",
      "空间模数与净空 / 婴儿车与杂物专属收纳：平面图纸必须在病床区域之外，沿墙体向内退让设计深0.80m的“婴儿推车及家属行李专属停靠槽”，严禁这些物品侵占病房内部的疏散主通道。",
      "空间模数与净空 / 室内吊顶完成面净高：为容纳输液天轨系统与全床包围的隔帘轨道，并缓解患儿长时间仰卧的压抑感，室内吊顶完成面净高建议设定为2.80m。",
      "防火分隔与应急 / 生命通道极限净宽：留观室主入口门必须采用净宽大于或等于1.40m的子母门或自动平移门。门下地面必须绝对零门槛平接处理，确保留观病床在火灾时能直接连床推离。",
      "防火分隔与应急 / 连床疏散的避难间联动：即使留观室在首层，其内部通向大门的疏散主通道净宽必须实打实大于2.00m（剔除陪护椅占用）。若留观室设在二层，则必须就近配置容纳连床推入的消防避难间。",
      "防火分隔与应急 / 装修材料高阻燃标准：留观室面积大且人员密集，吊顶及顶棚必须采用A级不燃材料（如铝扣板）。墙面适儿化软包及隔帘织物必须由厂家提供B1级以上的阻燃检测合格报告。",
      "感控设施与边界 / 留观区洗手终端分布：大型开敞式留观室必须按每4至6床配置一个独立的非接触式洗手池（带防溅侧板）。洗手池旁必须标配感应式手部消毒液与擦手纸盒的物理挂位。",
      "感控设施与边界 / 内置母婴与卫生设施：留观室内或紧邻出口处，必须设置带折叠婴儿尿布台的无障碍/第三卫生间，且内部必须配置高度0.60m的儿童专用马桶与低位洗手池。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "留观床间距与操作界限",
        "requirement": "床间距不应小于1.20m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.2.5条",
        "suggestion": "考虑到儿童留观“双家属+婴儿车+折叠陪护椅”的极限占用，相邻病床净间距必须放大至1.50m以上，床尾至对侧墙面（或病床）的推床疏散通道净宽必须大于或等于2.00m。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "婴儿车与杂物专属收纳",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.1条",
        "suggestion": "平面图纸必须在病床区域之外，沿墙体向内退让设计深0.80m的“婴儿推车及家属行李专属停靠槽”，严禁这些物品侵占病房内部的疏散主通道。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "室内吊顶完成面净高",
        "requirement": "医疗用房的室内净高不宜低于2.60m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.9条",
        "suggestion": "为容纳输液天轨系统与全床包围的隔帘轨道，并缓解患儿长时间仰卧的压抑感，室内吊顶完成面净高建议设定为2.80m。"
      },
      {
        "dimension": "防火分隔与应急",
        "focus": "生命通道极限净宽",
        "requirement": "通向推床的门净宽不应小于1.10m。疏散出口门应为平开门或在火灾时具有平开功能的门，且不应设置门槛。",
        "source": "《综合医院建筑设计标准》第5.1.4条及《建筑防火通用规范》第7.2.1条",
        "suggestion": "留观室主入口门必须采用净宽大于或等于1.40m的子母门或自动平移门。门下地面必须绝对零门槛平接处理，确保留观病床在火灾时能直接连床推离。"
      },
      {
        "dimension": "防火分隔与应急",
        "focus": "连床疏散的避难间联动",
        "requirement": "高层病房楼应在二层及以上的每个病房楼层设置避难间。避难间应靠近疏散楼梯间。",
        "source": "《建筑防火通用规范》GB 55037-2022第7.1.5条",
        "suggestion": "即使留观室在首层，其内部通向大门的疏散主通道净宽必须实打实大于2.00m（剔除陪护椅占用）。若留观室设在二层，则必须就近配置容纳连床推入的消防避难间。"
      },
      {
        "dimension": "防火分隔与应急",
        "focus": "装修材料高阻燃标准",
        "requirement": "医疗建筑内部装修材料的燃烧性能等级不应低于A级，部分部位不应低于B1级。",
        "source": "《建筑防火通用规范》GB 55037-2022第6.1.1条",
        "suggestion": "留观室面积大且人员密集，吊顶及顶棚必须采用A级不燃材料（如铝扣板）。墙面适儿化软包及隔帘织物必须由厂家提供B1级以上的阻燃检测合格报告。"
      },
      {
        "dimension": "感控设施与边界",
        "focus": "留观区洗手终端分布",
        "requirement": "医疗用房的洗手盆应采用非手动开关，水龙头不应采用充气式，并应采取防止污水外溅的措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第6.2.5条及第6.2.6条",
        "suggestion": "大型开敞式留观室必须按每4至6床配置一个独立的非接触式洗手池（带防溅侧板）。洗手池旁必须标配感应式手部消毒液与擦手纸盒的物理挂位。"
      },
      {
        "dimension": "感控设施与边界",
        "focus": "内置母婴与卫生设施",
        "requirement": "男女卫生间的便器设置比例应小于或等于1:2。儿科等区域卫生间应设置儿童卫生间或儿童专用洁具等。",
        "source": "《综合医院建设标准》建标110-2021第三十九条（六）",
        "suggestion": "留观室内或紧邻出口处，必须设置带折叠婴儿尿布台的无障碍/第三卫生间，且内部必须配置高度0.60m的儿童专用马桶与低位洗手池。"
      },
      {
        "dimension": "室内装修与安全防护",
        "focus": "防跌落与防触电安全屏障",
        "requirement": "儿童诊疗区域的门窗、家具和楼地面等应采取必要的安全保护措施。",
        "source": "《综合医院建设标准》建标110-2021第三十九条（七）",
        "suggestion": "（核心盲点）留观室外窗必须安装带钥匙的物理限位器，开启扇缝隙宽度严格锁死在10cm以内。墙面强电插座必须加装带锁的安全防护盖，或安装在1.30m以上高度。"
      },
      {
        "dimension": "室内装修与安全防护",
        "focus": "地材防滑与无缝抗菌",
        "requirement": "医疗用房的地面、踢脚板、墙裙、墙面、顶棚应便于清扫或冲洗。地面不应设地垄沟。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.12条及第5.1.10条",
        "suggestion": "地面必须满铺防滑等级R10以上的2.0mm同质透心PVC卷材，上卷上墙15cm形成圆弧阴角。接缝热熔焊接，防止留观患儿呕吐物渗漏发臭。"
      },
      {
        "dimension": "室内装修与安全防护",
        "focus": "阴阳角防撞与护墙板",
        "requirement": "其阴阳角宜做成圆角。有推床或推车通过的门和墙面，应采取防碰撞措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.12条及第39条（三）",
        "suggestion": "室内所有墙角、柱角必须执行半径大于或等于20mm的圆角工艺。沿走道及病床侧墙面0.20m与0.90m处必须满铺防撞护墙板或防撞扶手。"
      },
      {
        "dimension": "视觉干预与隐私",
        "focus": "护士站中心全景视野",
        "requirement": "护理单元应设护士站、治疗室、处置室、洗消间、更衣室、值班室等，护士站应与治疗室、办公用房邻近。",
        "source": "《儿童医院建设标准》建标174-2016第28条",
        "suggestion": "开敞式留观室的护士站必须采用中心岛式或半岛式布局。台面高度必须保证护士在坐姿状态下，视线能无物理死角地覆盖室内所有的留观床位。"
      },
      {
        "dimension": "视觉干预与隐私",
        "focus": "隐私隔绝与物理遮挡",
        "requirement": "检查、治疗用房应满足使用人群的隐私要求，注意开门方向，宜设闭门器。房间内宜设置隔帘或屏风。",
        "source": "《综合医院建设标准》建标110-2021第三十九条（八）",
        "suggestion": "每张留观床天花板必须预留满足全床包围的U型隔帘硬拉轨。隔帘底部必须悬空至少0.20m，以便护士走动巡视时能随时观察到床底是否有患儿滑落。"
      },
      {
        "dimension": "视觉干预与隐私",
        "focus": "防眩光与昼夜节律照明",
        "requirement": "医疗用房应采用高显色照明光源，显色指数应大于或等于80。综合医院注重改善患者的就医环境。",
        "source": "《综合医院建筑设计标准》第8.6.2条及《综合医院建设标准》第五条",
        "suggestion": "留观床正上方严禁设置直射光源。照明灯具必须采用漫反射防眩光设计，且必须支持双回路控制（日间高照度、夜间低照度巡视模式），保障患儿睡眠。"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 空间尺寸",
        "requirement": "开间×进深：3100×45000 mm；面积：14m²；净高：不小于2.8m",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "承担抢救功能，建议结合设备展开适当放大；原稿参考：医用建筑设计规范"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 墙面装修",
        "requirement": "墙面采用可擦洗丙烯酸涂料，床头区设MDF覆膜防撞护墙板",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "抗菌、易清洁、耐消毒；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 顶棚装修",
        "requirement": "可擦洗石膏板吊顶，平整、洁净、防尘",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "吸声、抗菌、防火；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 地面装修",
        "requirement": "防滑无缝医用PVC卷材，热焊接缝，150mm上翻踢脚",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "防滑、耐磨、易清洁；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 门工程",
        "requirement": "门净宽不小于1100mm，宜1200mm；满足推床、轮椅和急救设备通行",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "防夹手、易清洁；原稿参考：急诊通行要求"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 窗工程",
        "requirement": "中空Low-E玻璃，内置百叶/医用窗帘",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "隔热、隐私保护；原稿参考：实际诊疗需求"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 安全隐私",
        "requirement": "轨道式医用防霉隔帘",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "可伸缩、易清洁；原稿参考：医用建筑设计规范"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 洗手设施",
        "requirement": "配备医用洗手盆及相关配件",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "防溅、易消毒；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "配置复核",
        "focus": "[7.13手册] 家具配置清单",
        "requirement": "儿童留观床/诊疗恢复床×1（1800×700×550-750）；陪护椅/家属椅×1（550×550×850）；床位隔帘×1（3000×2200）；一次性手套分配器×1（250×100×140）；手消毒液分配器×1（120×110×250）；医疗废物桶20L×1（320×320×450）；普通垃圾桶20L×1（320×320×450）；锐器盒及支架7L×1（270×170×300）；小型床头柜/置物柜×1（450×450×650）；患者服务面板/床头面板×1（1600×200×450）；儿童安全防撞护墙板×1（1800×20×900）",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "按真实设备外廓、检修面、门区和操作净空复核；数量为项目手册预设，不替代批准后的设备清单。"
      },
      {
        "dimension": "配置复核",
        "focus": "[7.13手册] 医疗设备配置清单",
        "requirement": "氧气流量计×2（150×60×170）；空气流量计×2（150×60×170）；患者服务面板/墙面服务面板×1（1800×200×450）；负压压差显示/报警装置×1（200×80×160）；负压吸引适配器×2（120×60×120）；吸引瓶×2（120×120×250）；吸引瓶支架×2（160×120×180）；移动输液架×1（500×500×1200-2200）；单通道输液泵×1（150×200×180）；儿童多参数监护仪×1（360×280×300）；顶装/壁挂检查灯×1（600×600×1200）",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "按真实设备外廓、检修面、门区和操作净空复核；数量为项目手册预设，不替代批准后的设备清单。"
      },
      {
        "dimension": "源数据校核",
        "focus": "[7.13手册] 原稿数值疑点",
        "requirement": "原稿写为 3100×45000 mm、14m²，尺寸乘积与面积明显不一致；保留原文，模型暂按 3100×4500 mm 的编辑推定复核，不作为强制审查底线。",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "待编审确认前标记为“原稿待复核”，不自动生成不合格结论。"
      }
    ],
    "glbModel": "glb/er-observation.glb",
    "glbModelDisabled": true,
    "glbModelStatus": "逐房间复核标记为尺度/游离构件异常，待重新归零导出后启用",
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 19,
      "priority": "P0",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 21,
      "finalStatus": "部分完成",
      "finalRequirement": "护士与洗手盆退出门区；隔帘默认收拢并可动态闭合；GLB 重导出前以程序化场景为准。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "补齐缺失柜体构造函数；护士椅和护士移至台柜工作侧并面向四床视野中心，修正头部埋入台面的错误；同步调整储物柜与陪护位。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）",
    "glbModelDisabledReason": "2026-07-13 GLB 包围核查发现尺度、原点或游离构件异常；程序场景保留，清理并统一米制重导前禁用实景切换。",
    "glbAuditStatus": "隔离待重导",
    "manual713": {
      "title": "图3.x 急诊留观室布局三维示意见图（图片来源：笔者自绘）",
      "overview": "",
      "architecture": [
        {
          "item": "空间尺寸",
          "requirement": "开间×进深：3100×45000 mm；面积：14m²；净高：不小于2.8m",
          "unit": "项",
          "reference": "医用建筑设计规范",
          "note": "承担抢救功能，建议结合设备展开适当放大"
        },
        {
          "item": "墙面装修",
          "requirement": "墙面采用可擦洗丙烯酸涂料，床头区设MDF覆膜防撞护墙板",
          "unit": "项",
          "reference": "GB 50333-2013",
          "note": "抗菌、易清洁、耐消毒"
        },
        {
          "item": "顶棚装修",
          "requirement": "可擦洗石膏板吊顶，平整、洁净、防尘",
          "unit": "项",
          "reference": "GB 50333-2013",
          "note": "吸声、抗菌、防火"
        },
        {
          "item": "地面装修",
          "requirement": "防滑无缝医用PVC卷材，热焊接缝，150mm上翻踢脚",
          "unit": "项",
          "reference": "GB 50333-2013",
          "note": "防滑、耐磨、易清洁"
        },
        {
          "item": "门工程",
          "requirement": "门净宽不小于1100mm，宜1200mm；满足推床、轮椅和急救设备通行",
          "unit": "樘",
          "reference": "急诊通行要求",
          "note": "防夹手、易清洁"
        },
        {
          "item": "窗工程",
          "requirement": "中空Low-E玻璃，内置百叶/医用窗帘",
          "unit": "m²",
          "reference": "实际诊疗需求",
          "note": "隔热、隐私保护"
        },
        {
          "item": "安全隐私",
          "requirement": "轨道式医用防霉隔帘",
          "unit": "套",
          "reference": "医用建筑设计规范",
          "note": "可伸缩、易清洁"
        },
        {
          "item": "洗手设施",
          "requirement": "配备医用洗手盆及相关配件",
          "unit": "套",
          "reference": "GB 50333-2013",
          "note": "防溅、易消毒"
        }
      ],
      "equipment": [
        {
          "category": "家具",
          "item": "儿童留观床/诊疗恢复床",
          "quantity": "1",
          "specification": "1800×700×550-750",
          "note": "带护栏、脚轮，高度可调"
        },
        {
          "category": "家具",
          "item": "陪护椅/家属椅",
          "quantity": "1",
          "specification": "550×550×850",
          "note": "可选折叠或陪护椅"
        },
        {
          "category": "家具",
          "item": "床位隔帘",
          "quantity": "1",
          "specification": "3000×2200",
          "note": "保护患儿隐私"
        },
        {
          "category": "家具",
          "item": "一次性手套分配器",
          "quantity": "1",
          "specification": "250×100×140",
          "note": "壁挂安装"
        },
        {
          "category": "家具",
          "item": "手消毒液分配器",
          "quantity": "1",
          "specification": "120×110×250",
          "note": "入口或床旁设置"
        },
        {
          "category": "家具",
          "item": "医疗废物桶20L",
          "quantity": "1",
          "specification": "320×320×450",
          "note": "脚踏式或感应式"
        },
        {
          "category": "家具",
          "item": "普通垃圾桶20L",
          "quantity": "1",
          "specification": "320×320×450",
          "note": "一般废弃物"
        },
        {
          "category": "家具",
          "item": "锐器盒及支架7L",
          "quantity": "1",
          "specification": "270×170×300",
          "note": "壁挂安装"
        },
        {
          "category": "家具",
          "item": "小型床头柜/置物柜",
          "quantity": "1",
          "specification": "450×450×650",
          "note": "儿童用品及护理物品放置"
        },
        {
          "category": "家具",
          "item": "患者服务面板/床头面板",
          "quantity": "1",
          "specification": "1600×200×450",
          "note": "集成医气、电源、呼叫、数据接口"
        },
        {
          "category": "家具",
          "item": "儿童安全防撞护墙板",
          "quantity": "1",
          "specification": "1800×20×900",
          "note": "床头及床侧墙面"
        },
        {
          "category": "医疗设备",
          "item": "氧气流量计",
          "quantity": "2",
          "specification": "150×60×170",
          "note": "接入患者服务面板"
        },
        {
          "category": "医疗设备",
          "item": "空气流量计",
          "quantity": "2",
          "specification": "150×60×170",
          "note": "接入患者服务面板"
        },
        {
          "category": "医疗设备",
          "item": "患者服务面板/墙面服务面板",
          "quantity": "1",
          "specification": "1800×200×450",
          "note": "集成医气、电源、通信、呼叫"
        },
        {
          "category": "医疗设备",
          "item": "负压压差显示/报警装置",
          "quantity": "1",
          "specification": "200×80×160",
          "note": "显示房间压差状态"
        },
        {
          "category": "医疗设备",
          "item": "负压吸引适配器",
          "quantity": "2",
          "specification": "120×60×120",
          "note": "接入患者服务面板"
        },
        {
          "category": "医疗设备",
          "item": "吸引瓶",
          "quantity": "2",
          "specification": "120×120×250",
          "note": "与吸引瓶支架配套"
        },
        {
          "category": "医疗设备",
          "item": "吸引瓶支架",
          "quantity": "2",
          "specification": "160×120×180",
          "note": "壁挂或服务面板配套"
        },
        {
          "category": "医疗设备",
          "item": "移动输液架",
          "quantity": "1",
          "specification": "500×500×1200-2200",
          "note": "高度可调"
        },
        {
          "category": "医疗设备",
          "item": "单通道输液泵",
          "quantity": "1",
          "specification": "150×200×180",
          "note": "安装于输液架"
        },
        {
          "category": "医疗设备",
          "item": "儿童多参数监护仪",
          "quantity": "1",
          "specification": "360×280×300",
          "note": "可选，观察生命体征"
        },
        {
          "category": "医疗设备",
          "item": "顶装/壁挂检查灯",
          "quantity": "1",
          "specification": "600×600×1200",
          "note": "可选，需接电源"
        }
      ],
      "notes": [
        "1. 所有设备和材料需符合国家医用相关标准，确保安全卫生。",
        "2. 尺寸可根据实际空间需求进行适当调整，但需保证功能完整性 。",
        "3. 建议选用易清洁、耐消毒、环保的材料和设备。",
        "4. 定期对设备进行维护保养，确保正常运行。",
        "5. 本清单可根据实际诊疗需求进行补充和调整。",
        "表3.x 急诊留观室配置清单"
      ],
      "rawAddedLines": [
        "图3.x 急诊留观室布局三维示意见图（图片来源：笔者自绘）",
        "房间名称",
        "急诊留观室",
        "图3.x急诊留观室平面布局图（图片来源：笔者自绘）",
        "房间名称",
        "急诊留观室",
        "一、建筑与装修要求",
        "项目类别",
        "详细规格/技术标准",
        "单位",
        "参考标准",
        "备注说明",
        "空间尺寸",
        "开间×进深：3100×45000 mm；面积：14m²；净高：不小于2.8m",
        "项",
        "医用建筑设计规范",
        "承担抢救功能，建议结合设备展开适当放大",
        "墙面装修",
        "墙面采用可擦洗丙烯酸涂料，床头区设MDF覆膜防撞护墙板",
        "项",
        "GB 50333-2013",
        "抗菌、易清洁、耐消毒",
        "顶棚装修",
        "可擦洗石膏板吊顶，平整、洁净、防尘",
        "项",
        "GB 50333-2013",
        "吸声、抗菌、防火",
        "地面装修",
        "防滑无缝医用PVC卷材，热焊接缝，150mm上翻踢脚",
        "项",
        "GB 50333-2013",
        "防滑、耐磨、易清洁",
        "门工程",
        "门净宽不小于1100mm，宜1200mm；满足推床、轮椅和急救设备通行",
        "樘",
        "急诊通行要求",
        "防夹手、易清洁",
        "窗工程",
        "中空Low-E玻璃，内置百叶/医用窗帘",
        "m²",
        "实际诊疗需求",
        "隔热、隐私保护",
        "安全隐私",
        "轨道式医用防霉隔帘",
        "套",
        "医用建筑设计规范",
        "可伸缩、易清洁",
        "洗手设施",
        "配备医用洗手盆及相关配件",
        "套",
        "GB 50333-2013",
        "防溅、易消毒",
        "二、装备与设施清单",
        "项目类别",
        "物品名称",
        "数量",
        "规格 (L×W×H/mm)",
        "备注说明",
        "家具",
        "儿童留观床/诊疗恢复床",
        "1",
        "1800×700×550-750",
        "带护栏、脚轮，高度可调",
        "陪护椅/家属椅",
        "1",
        "550×550×850",
        "可选折叠或陪护椅",
        "床位隔帘",
        "1",
        "3000×2200",
        "保护患儿隐私",
        "一次性手套分配器",
        "1",
        "250×100×140",
        "壁挂安装",
        "手消毒液分配器",
        "1",
        "120×110×250",
        "入口或床旁设置",
        "医疗废物桶20L",
        "1",
        "320×320×450",
        "脚踏式或感应式",
        "普通垃圾桶20L",
        "1",
        "320×320×450",
        "一般废弃物",
        "锐器盒及支架7L",
        "1",
        "270×170×300",
        "壁挂安装",
        "小型床头柜/置物柜",
        "1",
        "450×450×650",
        "儿童用品及护理物品放置",
        "患者服务面板/床头面板",
        "1",
        "1600×200×450",
        "集成医气、电源、呼叫、数据接口",
        "儿童安全防撞护墙板",
        "1",
        "1800×20×900",
        "床头及床侧墙面",
        "医疗设备",
        "氧气流量计",
        "2",
        "150×60×170",
        "接入患者服务面板",
        "空气流量计",
        "2",
        "150×60×170",
        "接入患者服务面板",
        "患者服务面板/墙面服务面板",
        "1",
        "1800×200×450",
        "集成医气、电源、通信、呼叫",
        "负压压差显示/报警装置",
        "1",
        "200×80×160",
        "显示房间压差状态",
        "负压吸引适配器",
        "2",
        "120×60×120",
        "接入患者服务面板",
        "吸引瓶",
        "2",
        "120×120×250",
        "与吸引瓶支架配套",
        "吸引瓶支架",
        "2",
        "160×120×180",
        "壁挂或服务面板配套",
        "移动输液架",
        "1",
        "500×500×1200-2200",
        "高度可调",
        "单通道输液泵",
        "1",
        "150×200×180",
        "安装于输液架",
        "儿童多参数监护仪",
        "1",
        "360×280×300",
        "可选，观察生命体征",
        "顶装/壁挂检查灯",
        "1",
        "600×600×1200",
        "可选，需接电源",
        "备注说明",
        "1. 所有设备和材料需符合国家医用相关标准，确保安全卫生。",
        "2. 尺寸可根据实际空间需求进行适当调整，但需保证功能完整性 。",
        "3. 建议选用易清洁、耐消毒、环保的材料和设备。",
        "4. 定期对设备进行维护保养，确保正常运行。",
        "5. 本清单可根据实际诊疗需求进行补充和调整。",
        "表3.x 急诊留观室配置清单"
      ],
      "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
      "sourceIssues": [
        "原稿写为 3100×45000 mm、14m²，尺寸乘积与面积明显不一致；保留原文，模型暂按 3100×4500 mm 的编辑推定复核，不作为强制审查底线。"
      ]
    }
  },
  {
    "id": "ed_resus",
    "dept": "急诊",
    "name": "急诊抢救室",
    "type": "resus",
    "priority": "P1",
    "summary": "急诊抢救室审图重点包括单床净使用面积界限、床间距与操作通道、室内吊顶完成面净高等内容；依据《综合医院建筑设计标准》GB 51039-2014第5.3.11条；《综合医院建筑设计标准》GB 51039-2014第5.1.9条及第4.3.2条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/急诊/行为示意图/抢救单元.png",
      "docs/materials/2026.7.6/急诊/轴测/抢救单元01.png",
      "docs/materials/2026.7.6/急诊/轴测/抢救单元02.png",
      "docs/materials/2026.7.6/急诊/CAD/7.6_急诊集合_t3.dwg",
      "docs/materials/2026.7.6/急诊/模型/new_急诊抢救单元.skp"
    ],
    "preview": "assets/img/previews/ed_cpr.jpg",
    "rules": [
      "area",
      "handwash",
      "privacy",
      "child"
    ],
    "siteModel": "models/viewer.html?scene=er-resus",
    "siteModelName": "3D交互信息模型（急诊抢救室·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "急诊抢救室审图重点包括单床净使用面积界限、床间距与操作通道、室内吊顶完成面净高等内容；依据《综合医院建筑设计标准》GB 51039-2014第5.3.11条；《综合医院建筑设计标准》GB 51039-2014第5.1.9条及第4.3.2条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "单床净使用面积界限：急诊抢救室每床净使用面积不应小于12.00㎡。",
      "床间距与操作通道：抢救床净间距不应小于1.20m。",
      "室内吊顶完成面净高：医疗用房的室内净高不宜低于2.60m。建筑结构设计应满足医疗设备、悬挂装置等对荷载及安装的要求。",
      "生命通道极限净宽：通向推床的门净宽不应小于1.10m。疏散出口门应为平开门或在火灾时具有平开功能的门，且不应设置门槛。",
      "核心救治区防火分隔：医院中的手术部、急诊部、重症监护室、贵重精密医疗设备用房等，应采用防火隔墙和不燃楼板与其他部位分隔。",
      "装修材料燃烧性能：医疗建筑内部装修材料的燃烧性能等级不应低于A级，部分部位不应低于B1级。"
    ],
    "docReview": [
      "空间模数与净空 / 单床净使用面积界限：考虑到儿童抢救需容纳“医护抢救组+仪器推车+双家长”同时在场，建议单床净使用面积按18.00㎡至20.00㎡的模数进行空间预留。",
      "空间模数与净空 / 床间距与操作通道：抢救床头必须脱离墙面放置。为保证除颤仪、便携超声及抢救车的瞬时推入，床两侧净操作通道必须大于或等于1.50m。",
      "空间模数与净空 / 室内吊顶完成面净高：为容纳悬挂式医疗吊塔并缓解患儿仰卧时的压抑感，室内吊顶完成面净高建议设定为2.80m。图纸必须提供天花板承重预埋件的大样图。",
      "防火分隔与应急 / 生命通道极限净宽：抢救室主门必须采用净宽大于或等于1.40m的感应式或脚踏式自动平移门（带防夹及应急推开功能）。门下地面必须绝对零门槛平接处理。",
      "防火分隔与应急 / 核心救治区防火分隔：抢救室作为急诊部内火灾危险性管控的核心单元，其四周封闭墙体必须为耐火极限不低于2.00h的防火实体墙，确保火灾发生时能提供就地避难时间。",
      "防火分隔与应急 / 装修材料燃烧性能：抢救室吊顶及顶棚必须采用A级不燃材料。墙面适儿化防撞软包或医用树脂板必须由厂家提供B1级以上的阻燃检测合格报告。",
      "防火分隔与应急 / 隐蔽孔洞防火密闭封堵：穿越抢救室墙体的各类孔洞（即使不审机电，建筑开洞也必须封堵），必须使用防火泥或防火膨胀模块进行全密实柔性封堵，彻底杜绝火灾烟气串流。",
      "感控要求与设施 / 抢救区洗手终端分布：抢救室内必须配置独立的非接触式洗手池，采用感应式或膝碰式龙头。必须加装恒温防烫阀，出水温度锁定在35℃至38℃之间。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "单床净使用面积界限",
        "requirement": "急诊抢救室每床净使用面积不应小于12.00㎡。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.3.11条",
        "suggestion": "考虑到儿童抢救需容纳“医护抢救组+仪器推车+双家长”同时在场，建议单床净使用面积按18.00㎡至20.00㎡的模数进行空间预留。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "床间距与操作通道",
        "requirement": "抢救床净间距不应小于1.20m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.3.11条",
        "suggestion": "抢救床头必须脱离墙面放置。为保证除颤仪、便携超声及抢救车的瞬时推入，床两侧净操作通道必须大于或等于1.50m。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "室内吊顶完成面净高",
        "requirement": "医疗用房的室内净高不宜低于2.60m。建筑结构设计应满足医疗设备、悬挂装置等对荷载及安装的要求。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.9条及第4.3.2条",
        "suggestion": "为容纳悬挂式医疗吊塔并缓解患儿仰卧时的压抑感，室内吊顶完成面净高建议设定为2.80m。图纸必须提供天花板承重预埋件的大样图。"
      },
      {
        "dimension": "防火分隔与应急",
        "focus": "生命通道极限净宽",
        "requirement": "通向推床的门净宽不应小于1.10m。疏散出口门应为平开门或在火灾时具有平开功能的门，且不应设置门槛。",
        "source": "《综合医院建筑设计标准》第5.1.4条及《建筑防火通用规范》第7.2.1条",
        "suggestion": "抢救室主门必须采用净宽大于或等于1.40m的感应式或脚踏式自动平移门（带防夹及应急推开功能）。门下地面必须绝对零门槛平接处理。"
      },
      {
        "dimension": "防火分隔与应急",
        "focus": "核心救治区防火分隔",
        "requirement": "医院中的手术部、急诊部、重症监护室、贵重精密医疗设备用房等，应采用防火隔墙和不燃楼板与其他部位分隔。",
        "source": "《建筑防火通用规范》GB 55037-2022第4.3.1条",
        "suggestion": "抢救室作为急诊部内火灾危险性管控的核心单元，其四周封闭墙体必须为耐火极限不低于2.00h的防火实体墙，确保火灾发生时能提供就地避难时间。"
      },
      {
        "dimension": "防火分隔与应急",
        "focus": "装修材料燃烧性能",
        "requirement": "医疗建筑内部装修材料的燃烧性能等级不应低于A级，部分部位不应低于B1级。",
        "source": "《建筑防火通用规范》GB 55037-2022第6.1.1条",
        "suggestion": "抢救室吊顶及顶棚必须采用A级不燃材料。墙面适儿化防撞软包或医用树脂板必须由厂家提供B1级以上的阻燃检测合格报告。"
      },
      {
        "dimension": "防火分隔与应急",
        "focus": "隐蔽孔洞防火密闭封堵",
        "requirement": "建筑内各类管线穿过防火墙、防火隔墙、楼板的孔洞应采用防火封堵材料封堵。",
        "source": "《建筑防火通用规范》GB 55037-2022第6.3.1条",
        "suggestion": "穿越抢救室墙体的各类孔洞（即使不审机电，建筑开洞也必须封堵），必须使用防火泥或防火膨胀模块进行全密实柔性封堵，彻底杜绝火灾烟气串流。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "抢救区洗手终端分布",
        "requirement": "医疗用房的洗手盆应采用非手动开关，水龙头不应采用充气式，并应采取防止污水外溅的措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第6.2.5条及第6.2.6条",
        "suggestion": "抢救室内必须配置独立的非接触式洗手池，采用感应式或膝碰式龙头。必须加装恒温防烫阀，出水温度锁定在35℃至38℃之间。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "防溢地漏与冲洗构造",
        "requirement": "卫生间、污洗间、洗涤等有水区域应设地漏。地漏应采用带防干涸水封的地漏，水封深度不得小于50mm。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第6.2.7条",
        "suggestion": "抢救床侧边宜设置医疗级可开启式密封防溢地漏。非冲洗状态下必须绝对物理锁死，彻底杜绝下水道气溶胶倒灌。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "地材防静电与易洁性",
        "requirement": "医疗用房的地面应平整、防滑、易清洁、耐磨、耐腐蚀、不产尘，部分医疗用房地面应防静电。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.10条",
        "suggestion": "地面必须采用2.0mm厚度以上的同质透心防静电PVC卷材，上卷上墙15cm形成圆弧阴角，防止抢救时的血液或体液渗入墙角缝隙。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "阴阳角防撞与立面保护",
        "requirement": "其阴阳角宜做成圆角。有推床或推车通过的门和墙面，应采取防碰撞措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.12条及《综合医院建设标准》第39条（三）",
        "suggestion": "室内所有墙角、柱角必须执行半径大于或等于20mm的圆角工艺。墙面0.20m及0.90m处满铺高强度医用树脂防撞带，防止推车撞坏墙面。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "吸音降噪与声学顶棚",
        "requirement": "综合医院注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
        "source": "《综合医院建设标准》建标110-2021第五条",
        "suggestion": "抢救室内监护仪报警声密集，极易引发患儿恐慌。吊顶必须采用降噪系数（NRC）大于或等于0.7的微孔吸音金属板或抗菌矿棉板。"
      },
      {
        "dimension": "视觉干预与隐私",
        "focus": "护士站双向监护视窗",
        "requirement": "护理单元应设护士站、治疗室、处置室、洗消间、更衣室、值班室等，护士站应与治疗室、办公用房邻近。",
        "source": "《儿童医院建设标准》建标174-2016第28条",
        "suggestion": "抢救室与外部护士站之间的隔墙上，开设宽幅的透明防火观察窗，确保护士站对室内抢救床位具有无死角的持续监护视线。"
      },
      {
        "dimension": "视觉干预与隐私",
        "focus": "隐私隔绝与物理遮挡",
        "requirement": "检查、治疗用房应满足使用人群的隐私要求，注意开门方向，宜设闭门器。房间内宜设置隔帘或屏风。",
        "source": "《综合医院建设标准》建标110-2021第三十九条（八）",
        "suggestion": "观察窗内嵌入手动或电动百叶，或采用通电雾化玻璃。每张抢救床天花板必须预留满足全床包围的U型隔帘硬拉轨，提供抢救时的视觉遮挡。"
      },
      {
        "dimension": "视觉干预与隐私",
        "focus": "天花板视觉分散设计",
        "requirement": "综合医院注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
        "source": "《综合医院建设标准》建标110-2021第五条",
        "suggestion": "建议在抢救床正上方的天花板区域设置背光式卡通发光软膜天花，利用正向视觉吸引转移患儿对抢救操作的极度恐惧。"
      },
      {
        "dimension": "床旁接口",
        "focus": "[7.13手册] 吊塔与墙面备用终端",
        "requirement": "急诊抢救单元宜以医用吊塔作为床旁主要能源与信息接口，集成氧气、负压吸引、压缩空气、电源、网络、监护及设备挂载功能。采用岛式抢救床布置时，可不设置外凸式连续医疗带；但应在床头墙面或侧墙设置暗装备用医疗气体、电源及信息终端，作为吊塔检修、接口冗余、移动设备停靠及转运交接时的辅助支持。墙面终端应避免突出患儿及家属活动界面，不得侵占床旁抢救操作净空。",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "信息模型同步显示吊塔主接口、暗装墙面备份终端和床旁净空，不把墙面备份误作外凸连续设备带。"
      }
    ],
    "glbModel": "glb/er-resus-single.glb",
    "glbModelDisabled": true,
    "glbModelStatus": "逐房间复核标记为尺度/游离构件异常，待重新归零导出后启用",
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 20,
      "priority": "P1",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 22,
      "finalStatus": "部分完成",
      "finalRequirement": "校正锐器盒和吊塔；补吊塔/墙面备用接口及设备运动状态。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）",
    "glbModelDisabledReason": "2026-07-13 GLB 包围核查发现尺度、原点或游离构件异常；程序场景保留，清理并统一米制重导前禁用实景切换。",
    "glbAuditStatus": "隔离待重导",
    "manual713": {
      "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
      "movedNote": "急诊抢救单元宜以医用吊塔作为床旁主要能源与信息接口，集成氧气、负压吸引、压缩空气、电源、网络、监护及设备挂载功能。采用岛式抢救床布置时，可不设置外凸式连续医疗带；但应在床头墙面或侧墙设置暗装备用医疗气体、电源及信息终端，作为吊塔检修、接口冗余、移动设备停靠及转运交接时的辅助支持。墙面终端应避免突出患儿及家属活动界面，不得侵占床旁抢救操作净空。"
    }
  },
  {
    "id": "ed_treat",
    "dept": "急诊",
    "name": "非封闭急诊治疗室（单床）",
    "type": "treatment",
    "priority": "P3",
    "summary": "非封闭急诊治疗室（单床）审图重点包括单床单元物理净面积底线、“医+患+家属”多维退让尺寸、中枢护士站视线绝对可及等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.1.1条；《综合医院建筑设计标准》GB 51039-2014 第5.3.2条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/急诊/行为示意图/急诊治疗室.png",
      "docs/materials/2026.7.6/急诊/CAD/7.6_急诊集合_t3.dwg",
      "docs/materials/2026.7.6/急诊/模型/急诊治疗2.skp",
      "docs/materials/2026.7.13/急诊/轴测/急诊治疗室.png"
    ],
    "preview": "assets/img/previews/ed_treat.jpg",
    "rules": [
      "area",
      "handwash",
      "privacy",
      "child"
    ],
    "siteModel": "models/viewer.html?scene=er-treat",
    "siteModelName": "3D交互信息模型（非封闭急诊治疗室（单床）·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "非封闭急诊治疗室（单床）审图重点包括单床单元物理净面积底线、“医+患+家属”多维退让尺寸、中枢护士站视线绝对可及等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.1.1条；《综合医院建筑设计标准》GB 51039-2014 第5.3.2条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "单床单元物理净面积底线：医疗各项功能用房的设置应符合医疗工艺流程。",
      "“医+患+家属”多维退让尺寸：诊疗床的侧边净距离不应小于0.80m。",
      "中枢护士站视线绝对可及：抢救室应邻近分诊处和急诊入口应设看护患者的护士站。",
      "开敞侧绝对无门槛平接：疏散出口门、疏散走道中的门应向疏散方向开启，且不应设置门槛。",
      "大平层防火分区外围边界：医院中的急诊部、重症监护室等，应采用防火隔墙和不燃楼板与其他部位分隔。",
      "织物隔帘高烈度阻燃审查：建筑内部装修材料的燃烧性能等级不应低于A级，部分部位不应低于B1级。"
    ],
    "docReview": [
      "空间模数与净空 / 单床单元物理净面积底线：每个非封闭单床治疗单元（含帘隔断包络区域）的纯净使用面积不应小于6.00㎡（建议放大至8.00㎡），以保证容纳儿童急诊床及周边多方人员的站位。",
      "空间模数与净空 / “医+患+家属”多维退让尺寸：/",
      "空间模数与净空 / 中枢护士站视线绝对可及：单元的开敞面（或玻璃半隔断侧）必须正对或斜对急诊核心护士站。图纸需进行视线视锥分析，确保值班护士在坐姿状态下，视线能够越过通道阻隔，100%看清该病床上患儿的面部表情与生命指征。",
      "防火分隔与逃生 / 开敞侧绝对无门槛平接：治疗单元面向急诊主走廊的开敞面，其地面完成面必须与走廊实施绝对的“零高差、零门槛平接”。严禁在此处设计任何形式的微型装饰波导线凸起或收口条高差，保障抢救推车秒级无阻碍通行。",
      "防火分隔与逃生 / 大平层防火分区外围边界：虽然单床单元内部为非封闭或半封闭形式，但由数个单床组成的“急诊治疗区/大厅”其整体外围建筑隔墙，必须为耐火极限不低于2.00h的防爆防火实体隔墙，与外部候诊大厅实施绝对物理防火切分。",
      "防火分隔与逃生 / 织物隔帘高烈度阻燃审查：治疗单元高频使用的多工位隐私帘，属于极易蔓延火势的织物大立面。图纸选型中必须硬性标明“满足B1级阻燃标准”，且必须提供经高频次医用级含氯漂白洗涤后仍不降低阻燃性能的物料证明。",
      "物理边界与感控 / U型天轨防攀爬隐私隔帘：单床单元之间必须采用天花板预埋受力槽的“U型全包围天轨隔帘”。隔帘轨道的垂直高度必须确保大龄儿童站立时无法拉拽攀爬，隔帘底部必须精准离地0.20m至0.25m，以便于地面日常大水量消毒清扫及透光。",
      "物理边界与感控 / 近端非接触式手卫生终端：每2个相邻非封闭床位之间，必须在建筑交界墙体上并联嵌入设置一个非接触式（感应式）洗手池。水池四周建筑墙面必须做高度不低于0.40m的实体防溅侧板（如不锈钢或树脂板），严防污水溅向病床。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "单床单元物理净面积底线",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "每个非封闭单床治疗单元（含帘隔断包络区域）的纯净使用面积不应小于6.00㎡（建议放大至8.00㎡），以保证容纳儿童急诊床及周边多方人员的站位。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "“医+患+家属”多维退让尺寸",
        "requirement": "诊疗床的侧边净距离不应小于0.80m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.3.2条",
        "suggestion": "/"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "中枢护士站视线绝对可及",
        "requirement": "抢救室应邻近分诊处和急诊入口应设看护患者的护士站。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.3.2条及第5.3.3条",
        "suggestion": "单元的开敞面（或玻璃半隔断侧）必须正对或斜对急诊核心护士站。图纸需进行视线视锥分析，确保值班护士在坐姿状态下，视线能够越过通道阻隔，100%看清该病床上患儿的面部表情与生命指征。"
      },
      {
        "dimension": "防火分隔与逃生",
        "focus": "开敞侧绝对无门槛平接",
        "requirement": "疏散出口门、疏散走道中的门应向疏散方向开启，且不应设置门槛。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.2.1条",
        "suggestion": "治疗单元面向急诊主走廊的开敞面，其地面完成面必须与走廊实施绝对的“零高差、零门槛平接”。严禁在此处设计任何形式的微型装饰波导线凸起或收口条高差，保障抢救推车秒级无阻碍通行。"
      },
      {
        "dimension": "防火分隔与逃生",
        "focus": "大平层防火分区外围边界",
        "requirement": "医院中的急诊部、重症监护室等，应采用防火隔墙和不燃楼板与其他部位分隔。",
        "source": "《建筑防火通用规范》GB 55037-2022 第4.3.1条",
        "suggestion": "虽然单床单元内部为非封闭或半封闭形式，但由数个单床组成的“急诊治疗区/大厅”其整体外围建筑隔墙，必须为耐火极限不低于2.00h的防爆防火实体隔墙，与外部候诊大厅实施绝对物理防火切分。"
      },
      {
        "dimension": "防火分隔与逃生",
        "focus": "织物隔帘高烈度阻燃审查",
        "requirement": "建筑内部装修材料的燃烧性能等级不应低于A级，部分部位不应低于B1级。",
        "source": "《建筑防火通用规范》GB 55037-2022 第6.1.1条",
        "suggestion": "治疗单元高频使用的多工位隐私帘，属于极易蔓延火势的织物大立面。图纸选型中必须硬性标明“满足B1级阻燃标准”，且必须提供经高频次医用级含氯漂白洗涤后仍不降低阻燃性能的物料证明。"
      },
      {
        "dimension": "物理边界与感控",
        "focus": "U型天轨防攀爬隐私隔帘",
        "requirement": "检查、治疗用房应满足使用人群的隐私要求。房间内宜设置隔帘或屏风。",
        "source": "《综合医院建设标准》建标110-2021 第三十九条（八）",
        "suggestion": "单床单元之间必须采用天花板预埋受力槽的“U型全包围天轨隔帘”。隔帘轨道的垂直高度必须确保大龄儿童站立时无法拉拽攀爬，隔帘底部必须精准离地0.20m至0.25m，以便于地面日常大水量消毒清扫及透光。"
      },
      {
        "dimension": "物理边界与感控",
        "focus": "近端非接触式手卫生终端",
        "requirement": "医疗用房的洗手盆应采用非手动开关，水龙头不应采取充气式，并应采取防止污水外溅的措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第6.2.5条及第6.2.6条",
        "suggestion": "每2个相邻非封闭床位之间，必须在建筑交界墙体上并联嵌入设置一个非接触式（感应式）洗手池。水池四周建筑墙面必须做高度不低于0.40m的实体防溅侧板（如不锈钢或树脂板），严防污水溅向病床。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "墙面高柔韧抗击树脂板裙",
        "requirement": "其阴阳角宜做成圆角。有推床或推车通过的门和墙面，应采取防碰撞措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.12条及第39条（三）",
        "suggestion": "急诊推床在抢救时会发生剧烈物理撞击。单床单元内部及周边的所有建筑实体隔墙，从地面完成面向上至1.20m高度区间，必须满铺厚度不小于2mm的高强度抗撞击、耐含氯消毒剂擦洗的医用树脂板或抗倍特板。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "地材极限R角与一体化防渗",
        "requirement": "医疗用房的地面应平整、防滑、易清洁、耐磨、耐腐蚀、不产尘。地面不应设地垄沟。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.10条",
        "suggestion": "治疗室内极易滴落血液及呕吐物。地面必须满铺耐磨等级T级、防滑R10以上的同质透心PVC卷材。卷材必须顺墙面向上拉升0.15m，并使用专用圆弧边条做踢脚收口（阴角R≥30mm），实现“地面水密性防线”。"
      }
    ],
    "legacySiteModel": "models/model-real.html?space=resus",
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 15,
      "priority": "P3",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 17,
      "finalStatus": "已完成",
      "finalRequirement": "保留隔帘与治疗车动态状态。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "ed_triage",
    "dept": "急诊",
    "name": "预检分诊台",
    "type": "waiting",
    "priority": "P3",
    "summary": "预检分诊台审图重点包括双级服务台面高度、推车避让内凹模数、全局全景视野控制等内容；依据《综合医院建筑设计标准》GB 51039-2014第5.1.5条；《综合医院建筑设计标准》GB 51039-2014第5.2.3条及第5.1.1条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/急诊/行为示意图/分诊台.png",
      "docs/materials/2026.7.6/急诊/CAD/7.6_急诊集合_t3.dwg"
    ],
    "preview": "assets/img/previews/ed_triage.jpg",
    "rules": [
      "area",
      "handwash",
      "privacy",
      "child"
    ],
    "siteModel": "models/viewer.html?scene=er-triage",
    "siteModelName": "3D交互信息模型（预检分诊台·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "开间×进深：4500×2800 mm；建筑面积约12.6m²；参考净高≥2.80m。",
    "docFacts": [
      "双级服务台面高度：有轮椅通行的门和走道以及服务台等，应满足无障碍设施的规定。",
      "推车避让内凹模数：急诊部应设单独的预检分诊处。医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
      "全局全景视野控制：护理单元应设护士站……护士站应与治疗室、办公用房邻近。",
      "防暴安全逃生通道：综合医院的建设在满足各项功能需要的同时，注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
      "大堂主疏散宽度保护：疏散走道、疏散出口的净宽度应满足人员安全疏散的要求。走道净宽不应小于2.40m。",
      "台体结构材料阻燃：医疗建筑内部装修材料的燃烧性能等级不应低于A级，部分部位不应低于B1级。"
    ],
    "docReview": [
      "空间模数与视线 / 双级服务台面高度：必须设置高低双级台面。高台面（0.75m-0.80m）用于常规家长登记；低台面（0.70m以下且下方留空）专供轮椅患儿或矮小儿童进行无障碍沟通与体征测量。",
      "空间模数与视线 / 推车避让内凹模数：分诊台前方的平面布局必须向内退让，形成深度大于或等于1.20m的“婴儿推车与轮椅专属停靠槽”，确保排队登记时推车绝对不侵占急诊主干道的通行净宽。",
      "空间模数与视线 / 全局全景视野控制：分诊台必须处于急诊入口的视觉核心位置。护士在坐姿状态下，视线必须毫无物理遮挡地覆盖入口大门、候诊大厅全域及抢救室通道入口。",
      "防火分隔与应急 / 防暴安全逃生通道：（核心盲点）预检分诊台极易遭遇焦躁家属的冲击。分诊台内部绝对不能设计为“死胡同”，护士背后必须预留一扇直通内部办公区或抢救区的单向逃生暗门，且外部不可开启。",
      "防火分隔与应急 / 大堂主疏散宽度保护：审图时必须在平面图上拉出尺寸线：分诊台的最外凸出端（包含排队等候人群的预估占用范围），距离对侧墙体的直线净宽，必须实打实地大于或等于3.00m。",
      "防火分隔与应急 / 台体结构材料阻燃：作为逃生大堂中的大型固定家具构件，分诊台的内部骨架必须采用轻钢龙骨等A级不燃材料，外部饰面板必须出具B1级以上的阻燃检测合格报告。",
      "感控设施与边界 / 防飞沫物理屏障：预检分诊是筛查传染病的第一道防线，台面上方必须设置全封闭或半封闭的透明钢化玻璃防飞沫挡板，仅在底部留出高度不超过0.15m的病历及测温枪传递缝隙。",
      "感控设施与边界 / 台面级手消配置区：除了后台的标准洗手池，分诊台的面向患儿侧与护士操作侧台面上，必须在图纸中硬性划定感应式手部消毒液的固定安装点位，严禁临时随意摆放。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与视线",
        "focus": "双级服务台面高度",
        "requirement": "有轮椅通行的门和走道以及服务台等，应满足无障碍设施的规定。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.5条",
        "suggestion": "必须设置高低双级台面。高台面（0.75m-0.80m）用于常规家长登记；低台面（0.70m以下且下方留空）专供轮椅患儿或矮小儿童进行无障碍沟通与体征测量。"
      },
      {
        "dimension": "空间模数与视线",
        "focus": "推车避让内凹模数",
        "requirement": "急诊部应设单独的预检分诊处。医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.2.3条及第5.1.1条",
        "suggestion": "分诊台前方的平面布局必须向内退让，形成深度大于或等于1.20m的“婴儿推车与轮椅专属停靠槽”，确保排队登记时推车绝对不侵占急诊主干道的通行净宽。"
      },
      {
        "dimension": "空间模数与视线",
        "focus": "全局全景视野控制",
        "requirement": "护理单元应设护士站……护士站应与治疗室、办公用房邻近。",
        "source": "《儿童医院建设标准》建标174-2016第28条",
        "suggestion": "分诊台必须处于急诊入口的视觉核心位置。护士在坐姿状态下，视线必须毫无物理遮挡地覆盖入口大门、候诊大厅全域及抢救室通道入口。"
      },
      {
        "dimension": "防火分隔与应急",
        "focus": "防暴安全逃生通道",
        "requirement": "综合医院的建设在满足各项功能需要的同时，注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
        "source": "《综合医院建设标准》建标110-2021第五条（引申至医护心理安全与防卫）",
        "suggestion": "（核心盲点）预检分诊台极易遭遇焦躁家属的冲击。分诊台内部绝对不能设计为“死胡同”，护士背后必须预留一扇直通内部办公区或抢救区的单向逃生暗门，且外部不可开启。"
      },
      {
        "dimension": "防火分隔与应急",
        "focus": "大堂主疏散宽度保护",
        "requirement": "疏散走道、疏散出口的净宽度应满足人员安全疏散的要求。走道净宽不应小于2.40m。",
        "source": "《建筑防火通用规范》GB 55037-2022第7.1.4条及《综合医院建筑设计标准》第5.1.2条",
        "suggestion": "审图时必须在平面图上拉出尺寸线：分诊台的最外凸出端（包含排队等候人群的预估占用范围），距离对侧墙体的直线净宽，必须实打实地大于或等于3.00m。"
      },
      {
        "dimension": "防火分隔与应急",
        "focus": "台体结构材料阻燃",
        "requirement": "医疗建筑内部装修材料的燃烧性能等级不应低于A级，部分部位不应低于B1级。",
        "source": "《建筑防火通用规范》GB 55037-2022第6.1.1条",
        "suggestion": "作为逃生大堂中的大型固定家具构件，分诊台的内部骨架必须采用轻钢龙骨等A级不燃材料，外部饰面板必须出具B1级以上的阻燃检测合格报告。"
      },
      {
        "dimension": "感控设施与边界",
        "focus": "防飞沫物理屏障",
        "requirement": "医疗用房应通风良好，采取有效措施防止交叉感染。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第7.1.1条",
        "suggestion": "预检分诊是筛查传染病的第一道防线，台面上方必须设置全封闭或半封闭的透明钢化玻璃防飞沫挡板，仅在底部留出高度不超过0.15m的病历及测温枪传递缝隙。"
      },
      {
        "dimension": "感控设施与边界",
        "focus": "台面级手消配置区",
        "requirement": "医疗用房的洗手盆应采用非手动开关，水龙头不应采用充气式，并应采取防止污水外溅的措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第6.2.5条及第6.2.6条",
        "suggestion": "除了后台的标准洗手池，分诊台的面向患儿侧与护士操作侧台面上，必须在图纸中硬性划定感应式手部消毒液的固定安装点位，严禁临时随意摆放。"
      },
      {
        "dimension": "适儿化装修与防护",
        "focus": "台面及立面防撞处理",
        "requirement": "其阴阳角宜做成圆角。有推床或推车通过的门和墙面，应采取防碰撞措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.12条及《综合医院建设标准》第39条（三）",
        "suggestion": "分诊台所有面向公众的突出阳角、台面边缘必须全部执行半径大于或等于30mm的圆角打磨或软包覆工艺。立面0.20m高度处应设置不锈钢防踢防撞基座。"
      },
      {
        "dimension": "适儿化装修与防护",
        "focus": "饰面材料易洁与抗腐",
        "requirement": "医疗用房的地面、踢脚板、墙裙、墙面、顶棚应便于清扫或冲洗。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.12条",
        "suggestion": "分诊台的台面必须采用无缝拼接的人造石或医用抗菌抗倍特板，严禁使用接缝多、易渗入血污体液的多孔石材或木饰面板。"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 空间尺寸",
        "requirement": "开间×进深：4500×2800 mm；建筑面积约12.6m²；参考净高≥2.80m。",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "面积按图纸轴线尺寸折算，最终以建筑施工图复核。；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 墙面装修",
        "requirement": "采用光滑、耐擦洗、耐消毒、抗污染墙面。",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "分诊区靠近急诊入口，材料应耐高频清洁。；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 顶棚装修",
        "requirement": "医疗用可擦洗吊顶或防潮石膏板吊顶，平整密闭；嵌入照明、空调风口、广播/监控等末端协调布置。",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "照明避免屏幕反光，保证面部观察照度。；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 地面装修",
        "requirement": "同质透心PVC或橡胶卷材，防滑、耐磨、耐消毒；热焊接；踢脚上翻150mm并圆弧收口。",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "入口高流量区域宜加强耐磨等级。；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 门工程",
        "requirement": "门净宽建议≥1000 mm，设观察窗、防撞板、闭门器和无障碍拉手",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "门禁可与急诊安防联动，防止非授权进入后台。；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 窗工程",
        "requirement": "前端服务窗口宜设安全玻璃或半高隔断；保留医患交流视线，必要时配置可开启传声口、低位交流段。",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "儿童医院宜设置亲子友好高度及无障碍服务位。；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 安全隐私",
        "requirement": "设置分诊人员安全退避空间、紧急报警按钮、视频监控及数据安全视线控制；问诊位宜有声隐私措施，台面转角圆滑防碰撞。",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "避免候诊区人员直接看到电脑屏幕和病历信息。；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "7.13 手册",
        "focus": "[7.13手册] 洗手设施",
        "requirement": "配备医用洗手盆及相关配件",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "防溅、易消毒；原稿参考：GB 50333-2013"
      },
      {
        "dimension": "配置复核",
        "focus": "[7.13手册] 家具/设施配置清单",
        "requirement": "分诊服务台/评估柜台×1（4500×700×1050/750）；双人工位后台操作台×1（2400×700×750）；医护人体工学工作椅×2（500×500×800）；患儿/家属问诊椅×2（550×550×800）；洗手台柜×1（800×600×850）；台下活动柜/抽屉柜×2（400×500×650）；壁挂资料柜/吊柜×1（900×350×700）；表单资料架/文件盘×1（450×300×300）；安全玻璃隔断/半高挡板×1组（按现场定制）；等候导向标识/分诊标识牌×1组（按导视系统）；废物分类桶组×1组（20-50 L/只）；手卫生用品架/手套盒架×1组（壁挂式）",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "按真实设备外廓、检修面、门区和操作净空复核；数量为项目手册预设，不替代批准后的设备清单。"
      },
      {
        "dimension": "配置复核",
        "focus": "[7.13手册] 医疗设备配置清单",
        "requirement": "台式电脑及显示器×2套（一体机/台式）；键盘鼠标/扫码枪×2套（桌面型）；电话/对讲终端×1（桌面/壁挂）；打印机/标签腕带打印机×1（桌面型）；电子叫号/分诊显示屏×1（≥32 in）；生命体征监测仪×1（台式/推车式）；耳温枪/额温枪×2（便携式）；电子血压计×1（台式）；脉搏血氧仪×1（便携式）；儿童体重秤/婴儿秤×1（台式/落地式）；急救呼叫/安防报警按钮×2（台下/墙面）；摄像监控/拾音设备×1组（按安防系统）；双口数据点×2组（RJ45/光纤按项目）；双联电源插座×6组（220V，含应急电源）；UPS不间断电源×1（≥1 kVA）；小型应急评估包×1套（便携式）",
        "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
        "suggestion": "按真实设备外廓、检修面、门区和操作净空复核；数量为项目手册预设，不替代批准后的设备清单。"
      }
    ],
    "legacySiteModel": "models/model-real.html?space=triage",
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 26,
      "priority": "P3",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 28,
      "finalStatus": "部分完成",
      "finalRequirement": "诊桌后退形成入口流线；高低台组合允许接触；保留轮椅膝部空间。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）",
    "manual713": {
      "title": "预检分诊台",
      "overview": "开间×进深：4500×2800 mm；建筑面积约12.6m²；参考净高≥2.80m。",
      "architecture": [
        {
          "item": "空间尺寸",
          "requirement": "开间×进深：4500×2800 mm；建筑面积约12.6m²；参考净高≥2.80m。",
          "unit": "间",
          "reference": "GB 50333-2013",
          "note": "面积按图纸轴线尺寸折算，最终以建筑施工图复核。"
        },
        {
          "item": "墙面装修",
          "requirement": "采用光滑、耐擦洗、耐消毒、抗污染墙面。",
          "unit": "项",
          "reference": "GB 50333-2013",
          "note": "分诊区靠近急诊入口，材料应耐高频清洁。"
        },
        {
          "item": "顶棚装修",
          "requirement": "医疗用可擦洗吊顶或防潮石膏板吊顶，平整密闭；嵌入照明、空调风口、广播/监控等末端协调布置。",
          "unit": "项",
          "reference": "GB 50333-2013",
          "note": "照明避免屏幕反光，保证面部观察照度。"
        },
        {
          "item": "地面装修",
          "requirement": "同质透心PVC或橡胶卷材，防滑、耐磨、耐消毒；热焊接；踢脚上翻150mm并圆弧收口。",
          "unit": "项",
          "reference": "GB 50333-2013",
          "note": "入口高流量区域宜加强耐磨等级。"
        },
        {
          "item": "门工程",
          "requirement": "门净宽建议≥1000 mm，设观察窗、防撞板、闭门器和无障碍拉手",
          "unit": "樘",
          "reference": "GB 50333-2013",
          "note": "门禁可与急诊安防联动，防止非授权进入后台。"
        },
        {
          "item": "窗工程",
          "requirement": "前端服务窗口宜设安全玻璃或半高隔断；保留医患交流视线，必要时配置可开启传声口、低位交流段。",
          "unit": "项",
          "reference": "GB 50333-2013",
          "note": "儿童医院宜设置亲子友好高度及无障碍服务位。"
        },
        {
          "item": "安全隐私",
          "requirement": "设置分诊人员安全退避空间、紧急报警按钮、视频监控及数据安全视线控制；问诊位宜有声隐私措施，台面转角圆滑防碰撞。",
          "unit": "项",
          "reference": "GB 50333-2013",
          "note": "避免候诊区人员直接看到电脑屏幕和病历信息。"
        },
        {
          "item": "洗手设施",
          "requirement": "配备医用洗手盆及相关配件",
          "unit": "套",
          "reference": "GB 50333-2013",
          "note": "防溅、易消毒"
        }
      ],
      "equipment": [
        {
          "category": "家具/设施",
          "item": "分诊服务台/评估柜台",
          "quantity": "1",
          "specification": "4500×700×1050/750",
          "note": "含高低台面、理线槽、耐消毒台面。"
        },
        {
          "category": "家具/设施",
          "item": "双人工位后台操作台",
          "quantity": "1",
          "specification": "2400×700×750",
          "note": "用于预检登记、分级和病历录入。"
        },
        {
          "category": "家具/设施",
          "item": "医护人体工学工作椅",
          "quantity": "2",
          "specification": "500×500×800",
          "note": "带脚轮、升降、可擦洗面料；每分诊席1张。"
        },
        {
          "category": "家具/设施",
          "item": "患儿/家属问诊椅",
          "quantity": "2",
          "specification": "550×550×800",
          "note": "设于工作台前，便于短时问诊及测量生命体征。"
        },
        {
          "category": "家具/设施",
          "item": "洗手台柜",
          "quantity": "1",
          "specification": "800×600×850",
          "note": "与洗手盆配套，防水台面，台下可设检修空间。"
        },
        {
          "category": "家具/设施",
          "item": "台下活动柜/抽屉柜",
          "quantity": "2",
          "specification": "400×500×650",
          "note": "放置表单、文具、个人防护用品，带锁。"
        },
        {
          "category": "家具/设施",
          "item": "壁挂资料柜/吊柜",
          "quantity": "1",
          "specification": "900×350×700",
          "note": "存放分诊表、宣教单和备用耗材，安装避开头部碰撞区域。"
        },
        {
          "category": "家具/设施",
          "item": "表单资料架/文件盘",
          "quantity": "1",
          "specification": "450×300×300",
          "note": "图示台面资料位，用于挂号单、分诊单和腕带标签临时放置。"
        },
        {
          "category": "家具/设施",
          "item": "安全玻璃隔断/半高挡板",
          "quantity": "1组",
          "specification": "按现场定制",
          "note": "前端服务界面防飞沫、防冲撞，同时保留观察与沟通。"
        },
        {
          "category": "家具/设施",
          "item": "等候导向标识/分诊标识牌",
          "quantity": "1组",
          "specification": "按导视系统",
          "note": "明确预检分诊入口、儿科急诊分流和优先通道。"
        },
        {
          "category": "家具/设施",
          "item": "废物分类桶组",
          "quantity": "1组",
          "specification": "20-50 L/只",
          "note": "图示洗手区旁设置普通垃圾与医疗废物桶，脚踏带盖。"
        },
        {
          "category": "家具/设施",
          "item": "手卫生用品架/手套盒架",
          "quantity": "1组",
          "specification": "壁挂式",
          "note": "配置手套、口罩、速干手消，靠近洗手盆及分诊操作位。"
        },
        {
          "category": "医疗设备",
          "item": "台式电脑及显示器",
          "quantity": "2套",
          "specification": "一体机/台式",
          "note": "每分诊席1套，连接HIS/急诊分诊系统；屏幕防窥。"
        },
        {
          "category": "医疗设备",
          "item": "键盘鼠标/扫码枪",
          "quantity": "2套",
          "specification": "桌面型",
          "note": "扫码识别腕带、身份证/医保凭证或挂号单。"
        },
        {
          "category": "医疗设备",
          "item": "电话/对讲终端",
          "quantity": "1",
          "specification": "桌面/壁挂",
          "note": "联系抢救室、诊区、保安及收费挂号窗口。"
        },
        {
          "category": "医疗设备",
          "item": "打印机/标签腕带打印机",
          "quantity": "1",
          "specification": "桌面型",
          "note": "打印分诊标签、腕带、告知单和流转单。"
        },
        {
          "category": "医疗设备",
          "item": "电子叫号/分诊显示屏",
          "quantity": "1",
          "specification": "≥32 in",
          "note": "用于显示分诊队列、候诊提示和优先级引导。"
        },
        {
          "category": "医疗设备",
          "item": "生命体征监测仪",
          "quantity": "1",
          "specification": "台式/推车式",
          "note": "快速测量血压、血氧、脉率；配儿童袖带和探头。"
        },
        {
          "category": "医疗设备",
          "item": "耳温枪/额温枪",
          "quantity": "2",
          "specification": "便携式",
          "note": "入口预检快速筛查体温，儿童友好、易消毒。"
        },
        {
          "category": "医疗设备",
          "item": "电子血压计",
          "quantity": "1",
          "specification": "台式",
          "note": "配儿童、成人袖带；可与分诊系统录入结果。"
        },
        {
          "category": "医疗设备",
          "item": "脉搏血氧仪",
          "quantity": "1",
          "specification": "便携式",
          "note": "用于呼吸道症状、发绀或高危患儿快速评估。"
        },
        {
          "category": "医疗设备",
          "item": "儿童体重秤/婴儿秤",
          "quantity": "1",
          "specification": "台式/落地式",
          "note": "急诊给药剂量估算及分诊记录使用。"
        },
        {
          "category": "医疗设备",
          "item": "急救呼叫/安防报警按钮",
          "quantity": "2",
          "specification": "台下/墙面",
          "note": "分诊席和后台各设1处，联动护士站、安保或急诊控制台。"
        },
        {
          "category": "医疗设备",
          "item": "摄像监控/拾音设备",
          "quantity": "1组",
          "specification": "按安防系统",
          "note": "覆盖服务台前方，注意隐私区域和病历屏幕遮挡。"
        },
        {
          "category": "医疗设备",
          "item": "双口数据点",
          "quantity": "2组",
          "specification": "RJ45/光纤按项目",
          "note": "每分诊席不少于1组；参考复苏床位数据点配置原则。"
        },
        {
          "category": "医疗设备",
          "item": "双联电源插座",
          "quantity": "6组",
          "specification": "220V，含应急电源",
          "note": "电脑、打印、显示屏、生命体征设备及备用电源。"
        },
        {
          "category": "医疗设备",
          "item": "UPS不间断电源",
          "quantity": "1",
          "specification": "≥1 kVA",
          "note": "保障分诊系统、电话和标签打印短时不断电。"
        },
        {
          "category": "医疗设备",
          "item": "小型应急评估包",
          "quantity": "1套",
          "specification": "便携式",
          "note": "含手电、压舌板、一次性体温探头套、口罩、手套及消毒用品。"
        }
      ],
      "notes": [],
      "rawAddedLines": [
        "预检分诊台",
        "图3.x预检分诊台平面布局图（图片来源：笔者自绘）",
        "房间名称",
        "急诊预诊分诊台",
        "一、建筑与装修要求",
        "项目类别",
        "详细规格/技术标准",
        "单位",
        "参考标准",
        "备注说明",
        "空间尺寸",
        "开间×进深：4500×2800 mm；建筑面积约12.6m²；参考净高≥2.80m。",
        "间",
        "GB 50333-2013",
        "面积按图纸轴线尺寸折算，最终以建筑施工图复核。",
        "墙面装修",
        "采用光滑、耐擦洗、耐消毒、抗污染墙面。",
        "项",
        "GB 50333-2013",
        "分诊区靠近急诊入口，材料应耐高频清洁。",
        "顶棚装修",
        "医疗用可擦洗吊顶或防潮石膏板吊顶，平整密闭；嵌入照明、空调风口、广播/监控等末端协调布置。",
        "项",
        "GB 50333-2013",
        "照明避免屏幕反光，保证面部观察照度。",
        "地面装修",
        "同质透心PVC或橡胶卷材，防滑、耐磨、耐消毒；热焊接；踢脚上翻150mm并圆弧收口。",
        "项",
        "GB 50333-2013",
        "入口高流量区域宜加强耐磨等级。",
        "门工程",
        "门净宽建议≥1000 mm，设观察窗、防撞板、闭门器和无障碍拉手",
        "樘",
        "GB 50333-2013",
        "门禁可与急诊安防联动，防止非授权进入后台。",
        "窗工程",
        "前端服务窗口宜设安全玻璃或半高隔断；保留医患交流视线，必要时配置可开启传声口、低位交流段。",
        "项",
        "GB 50333-2013",
        "儿童医院宜设置亲子友好高度及无障碍服务位。",
        "安全隐私",
        "设置分诊人员安全退避空间、紧急报警按钮、视频监控及数据安全视线控制；问诊位宜有声隐私措施，台面转角圆滑防碰撞。",
        "项",
        "GB 50333-2013",
        "避免候诊区人员直接看到电脑屏幕和病历信息。",
        "洗手设施",
        "配备医用洗手盆及相关配件",
        "套",
        "GB 50333-2013",
        "防溅、易消毒",
        "二、装备与设施清单",
        "项目类别",
        "物品名称",
        "数量",
        "规格(L×W×H/mm)",
        "备注说明",
        "家具/设施",
        "分诊服务台/评估柜台",
        "1",
        "4500×700×1050/750",
        "含高低台面、理线槽、耐消毒台面。",
        "双人工位后台操作台",
        "1",
        "2400×700×750",
        "用于预检登记、分级和病历录入。",
        "医护人体工学工作椅",
        "2",
        "500×500×800",
        "带脚轮、升降、可擦洗面料；每分诊席1张。",
        "患儿/家属问诊椅",
        "2",
        "550×550×800",
        "设于工作台前，便于短时问诊及测量生命体征。",
        "洗手台柜",
        "1",
        "800×600×850",
        "与洗手盆配套，防水台面，台下可设检修空间。",
        "台下活动柜/抽屉柜",
        "2",
        "400×500×650",
        "放置表单、文具、个人防护用品，带锁。",
        "壁挂资料柜/吊柜",
        "1",
        "900×350×700",
        "存放分诊表、宣教单和备用耗材，安装避开头部碰撞区域。",
        "表单资料架/文件盘",
        "1",
        "450×300×300",
        "图示台面资料位，用于挂号单、分诊单和腕带标签临时放置。",
        "安全玻璃隔断/半高挡板",
        "1组",
        "按现场定制",
        "前端服务界面防飞沫、防冲撞，同时保留观察与沟通。",
        "等候导向标识/分诊标识牌",
        "1组",
        "按导视系统",
        "明确预检分诊入口、儿科急诊分流和优先通道。",
        "废物分类桶组",
        "1组",
        "20-50 L/只",
        "图示洗手区旁设置普通垃圾与医疗废物桶，脚踏带盖。",
        "手卫生用品架/手套盒架",
        "1组",
        "壁挂式",
        "配置手套、口罩、速干手消，靠近洗手盆及分诊操作位。",
        "医疗设备",
        "台式电脑及显示器",
        "2套",
        "一体机/台式",
        "每分诊席1套，连接HIS/急诊分诊系统；屏幕防窥。",
        "键盘鼠标/扫码枪",
        "2套",
        "桌面型",
        "扫码识别腕带、身份证/医保凭证或挂号单。",
        "电话/对讲终端",
        "1",
        "桌面/壁挂",
        "联系抢救室、诊区、保安及收费挂号窗口。",
        "打印机/标签腕带打印机",
        "1",
        "桌面型",
        "打印分诊标签、腕带、告知单和流转单。",
        "电子叫号/分诊显示屏",
        "1",
        "≥32 in",
        "用于显示分诊队列、候诊提示和优先级引导。",
        "生命体征监测仪",
        "1",
        "台式/推车式",
        "快速测量血压、血氧、脉率；配儿童袖带和探头。",
        "耳温枪/额温枪",
        "2",
        "便携式",
        "入口预检快速筛查体温，儿童友好、易消毒。",
        "电子血压计",
        "1",
        "台式",
        "配儿童、成人袖带；可与分诊系统录入结果。",
        "脉搏血氧仪",
        "1",
        "便携式",
        "用于呼吸道症状、发绀或高危患儿快速评估。",
        "儿童体重秤/婴儿秤",
        "1",
        "台式/落地式",
        "急诊给药剂量估算及分诊记录使用。",
        "急救呼叫/安防报警按钮",
        "2",
        "台下/墙面",
        "分诊席和后台各设1处，联动护士站、安保或急诊控制台。",
        "摄像监控/拾音设备",
        "1组",
        "按安防系统",
        "覆盖服务台前方，注意隐私区域和病历屏幕遮挡。",
        "双口数据点",
        "2组",
        "RJ45/光纤按项目",
        "每分诊席不少于1组；参考复苏床位数据点配置原则。",
        "双联电源插座",
        "6组",
        "220V，含应急电源",
        "电脑、打印、显示屏、生命体征设备及备用电源。",
        "UPS不间断电源",
        "1",
        "≥1 kVA",
        "保障分诊系统、电话和标签打印短时不断电。",
        "小型应急评估包",
        "1套",
        "便携式",
        "含手电、压舌板、一次性体温探头套、口罩、手套及消毒用品。",
        "图3.x预诊分诊台配置清单（图片来源：笔者自绘）"
      ],
      "source": "7.13 医疗工艺标准图则及审图要点（项目手册，待正式条文复核）",
      "sourceIssues": []
    }
  },
  {
    "id": "ed_unit",
    "dept": "急诊",
    "name": "急诊单元",
    "type": "emergency",
    "priority": "P1",
    "summary": "急诊单元审图重点包括救治绿道连通性、科室协作邻近性、分诊视线控制等内容；依据《综合医院建筑设计标准》GB 51039-2014第5.2.1条；《综合医院建筑设计标准》GB 51039-2014第5.2.2条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/急诊/CAD/7.6_急诊集合_t3.dwg"
    ],
    "rules": [
      "area",
      "handwash",
      "privacy",
      "child"
    ],
    "siteModel": "models/viewer.html?scene=er-unit",
    "siteModelName": "3D交互信息模型（急诊单元·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "急诊单元审图重点包括救治绿道连通性、科室协作邻近性、分诊视线控制等内容；依据《综合医院建筑设计标准》GB 51039-2014第5.2.1条；《综合医院建筑设计标准》GB 51039-2014第5.2.2条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "救治绿道连通性：急诊部应自成一区，应设在建筑的首层，并应有独立的出入口。救护车停靠处应设雨篷。",
      "科室协作邻近性：急诊部应邻近放射科、检验科、手术部。",
      "分诊视线控制：护理单元应设护士站、治疗室、处置室、洗消间、更衣室、值班室等，护士站应与治疗室、办公用房邻近。",
      "通行净宽冗余：通行推床的走道净宽不应小于2.40m。通向推床的门净宽不应小于1.10m。",
      "候诊模数修正：儿科候诊区面积应按不小于2㎡/人设计。",
      "疏散能力冗余与零门槛构造：疏散出口门、疏散走道、疏散楼梯的净宽度应满足人员安全疏散的要求。疏散出口门、疏散走道中的门应向疏散方向开启，且不应设置门槛。"
    ],
    "docReview": [
      "流线效率 / 救治绿道连通性：救护车位至抢救室直线距离应控制在20m以内。应设置急诊专用医用电梯直达手术部及PICU，电梯门净宽建议设计为1.5m以满足多名医护推床同时进出。",
      "流线效率 / 科室协作邻近性：建议急诊药房、急诊化验室及放射检查室处于急诊大厅的“3分钟到达圆”内（步行距离小于等于45m），建立急救闭环。",
      "流线效率 / 分诊视线控制：分诊台与护士站至最远观察床位距离不应超过15m。必须确保护士站在坐姿状态下能对抢救区及候诊区患儿拥有100%的无死角直视视线。",
      "空间尺度 / 通行净宽冗余：考虑到儿童急诊患儿加两名以上家长及救治组的复合宽度，急诊主通道建议设计为3.0m。门洞净宽建议增加至1.4m至1.5m之间。",
      "空间尺度 / 候诊模数修正：应在标准候诊区外额外预留宽度为1.2m的专用推车与婴儿车停放带，避免婴儿推车占用公共疏散走道。候诊座椅宜采用防撞圆角设计。",
      "防火与应急疏散 / 疏散能力冗余与零门槛构造：患儿自救能力弱且推车转运多，疏散楼梯间净宽建议由标准的1.3m增加至1.5m至1.6m之间。疏散门门口地面必须绝对零门槛，防止带生命支持设备的推车转运时脱管。",
      "防火与应急疏散 / 核心区防火分隔与材料阻燃：急诊部内核心救治区应自成一个独立的火灾危险性管控单元，防火隔墙的耐火极限不低于2.00h。抢救室顶棚必须为A级不燃吸音材料，防撞软包必须提供B1级阻燃检测报告。",
      "防火与应急疏散 / 袋形走道极限距离：平面硬约束：急诊二级动线设计应尽量形成“环形走廊”，极力避免出现尽端式（袋形）走道。若必须设置，尽端到安全出口距离在设喷淋情况下绝不能超过11.25m，否则面临重大消防颠覆风险。"
    ],
    "docReviewRows": [
      {
        "dimension": "流线效率",
        "focus": "救治绿道连通性",
        "requirement": "急诊部应自成一区，应设在建筑的首层，并应有独立的出入口。救护车停靠处应设雨篷。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.2.1条",
        "suggestion": "救护车位至抢救室直线距离应控制在20m以内。应设置急诊专用医用电梯直达手术部及PICU，电梯门净宽建议设计为1.5m以满足多名医护推床同时进出。"
      },
      {
        "dimension": "流线效率",
        "focus": "科室协作邻近性",
        "requirement": "急诊部应邻近放射科、检验科、手术部。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.2.2条",
        "suggestion": "建议急诊药房、急诊化验室及放射检查室处于急诊大厅的“3分钟到达圆”内（步行距离小于等于45m），建立急救闭环。"
      },
      {
        "dimension": "流线效率",
        "focus": "分诊视线控制",
        "requirement": "护理单元应设护士站、治疗室、处置室、洗消间、更衣室、值班室等，护士站应与治疗室、办公用房邻近。",
        "source": "《儿童医院建设标准》建标174-2016第28条",
        "suggestion": "分诊台与护士站至最远观察床位距离不应超过15m。必须确保护士站在坐姿状态下能对抢救区及候诊区患儿拥有100%的无死角直视视线。"
      },
      {
        "dimension": "空间尺度",
        "focus": "通行净宽冗余",
        "requirement": "通行推床的走道净宽不应小于2.40m。通向推床的门净宽不应小于1.10m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.2条及第5.1.4条",
        "suggestion": "考虑到儿童急诊患儿加两名以上家长及救治组的复合宽度，急诊主通道建议设计为3.0m。门洞净宽建议增加至1.4m至1.5m之间。"
      },
      {
        "dimension": "空间尺度",
        "focus": "候诊模数修正",
        "requirement": "儿科候诊区面积应按不小于2㎡/人设计。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.2.6条",
        "suggestion": "应在标准候诊区外额外预留宽度为1.2m的专用推车与婴儿车停放带，避免婴儿推车占用公共疏散走道。候诊座椅宜采用防撞圆角设计。"
      },
      {
        "dimension": "防火与应急疏散",
        "focus": "疏散能力冗余与零门槛构造",
        "requirement": "疏散出口门、疏散走道、疏散楼梯的净宽度应满足人员安全疏散的要求。疏散出口门、疏散走道中的门应向疏散方向开启，且不应设置门槛。",
        "source": "《建筑防火通用规范》GB 55037-2022第7.1.4条及第7.2.1条",
        "suggestion": "患儿自救能力弱且推车转运多，疏散楼梯间净宽建议由标准的1.3m增加至1.5m至1.6m之间。疏散门门口地面必须绝对零门槛，防止带生命支持设备的推车转运时脱管。"
      },
      {
        "dimension": "防火与应急疏散",
        "focus": "核心区防火分隔与材料阻燃",
        "requirement": "医院中的手术部、急诊部、重症监护室、贵重精密医疗设备用房等，应采用防火隔墙和不燃楼板与其他部位分隔。",
        "source": "《建筑防火通用规范》GB 55037-2022第4.3.1条",
        "suggestion": "急诊部内核心救治区应自成一个独立的火灾危险性管控单元，防火隔墙的耐火极限不低于2.00h。抢救室顶棚必须为A级不燃吸音材料，防撞软包必须提供B1级阻燃检测报告。"
      },
      {
        "dimension": "防火与应急疏散",
        "focus": "袋形走道极限距离",
        "requirement": "医疗建筑位于两个安全出口之间的疏散门至最近安全出口的直线距离不应大于24m；位于袋形走道两侧或尽端的疏散门至最近安全出口的直线距离不应大于9m（设自喷可增加25%）。",
        "source": "《建筑设计防火规范》GB 50016-2014第5.5.17条",
        "suggestion": "平面硬约束：急诊二级动线设计应尽量形成“环形走廊”，极力避免出现尽端式（袋形）走道。若必须设置，尽端到安全出口距离在设喷淋情况下绝不能超过11.25m，否则面临重大消防颠覆风险。"
      },
      {
        "dimension": "防火与应急疏散",
        "focus": "常开防火门与流线畅通",
        "requirement": "疏散走道在防火分区处应设置常开甲级防火门。常开防火门应能在火灾时自行关闭，并应具有信号反馈的功能。",
        "source": "《建筑防火通用规范》GB 55037-2022第7.2.3条",
        "suggestion": "流线效率保障：急诊内部推车转运频繁，横跨防火分区的防火门平时必须为“常开”状态，严禁使用常闭防火门阻碍急救推车动线；且必须与火灾自动报警系统联动。"
      },
      {
        "dimension": "防火与应急疏散",
        "focus": "内部深区走道排烟",
        "requirement": "建筑内长度大于20m的疏散走道，应设置排烟设施。",
        "source": "《建筑防火通用规范》GB 55037-2022第9.2.2条",
        "suggestion": "天花板管线预留：急诊部往往进深极大，内部核心走廊通常无法自然通风。审图必须核查走廊天花板上方是否预留了足够尺寸的机械排烟管道空间，排烟口应避开患儿易触及区域。"
      },
      {
        "dimension": "防火与应急疏散",
        "focus": "疏散照明最低照度",
        "requirement": "疏散走道的地面最低水平照度，医疗建筑、老年人照料设施不应低于10.0lx。",
        "source": "《建筑防火通用规范》GB 55037-2022第10.1.8条",
        "suggestion": "防恐慌设计：儿童在黑暗和烟雾中极易产生极度恐慌。急诊主疏散走道、楼梯间的应急照明照度必须达到10.0lx（普通建筑仅为3.0lx）。建议在走道踢脚线处增设连续的发光疏散指示带。"
      },
      {
        "dimension": "感控要求",
        "focus": "传染病物理分区",
        "requirement": "急诊部应设传染病诊室，并应设在急诊部末端，应设独立出入口，并应附设专用卫生间。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.2.4条",
        "suggestion": "隔离诊室应设置气压缓冲间，建立动态空气屏障。排风系统应独立，且排风口应避开患儿室外游戏区域，防止气溶胶二次污染。"
      },
      {
        "dimension": "感控要求",
        "focus": "医患洁污分离",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理、洁污路线清楚。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.1条",
        "suggestion": "必须设置独立的医护专用洁净走廊。污物出口应避开急诊主大厅，通过专用污梯或污物通道运送至垃圾暂存点，污物走廊建议设置感应式自动门。"
      },
      {
        "dimension": "感控要求",
        "focus": "地面工艺与防积污",
        "requirement": "医疗用房地面应平整、防滑、易清洁、耐磨、耐腐蚀、不产尘，部分医疗用房地面应防静电。地面不应设地垄沟。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.10条",
        "suggestion": "急诊抢救区及污洗间地面必须采用同质透心卷材并上卷上墙15cm形成圆弧阴角，严禁存在卫生死角。防滑等级必须达到R10。"
      },
      {
        "dimension": "无障碍与安全防护",
        "focus": "视觉预知与防撞处理",
        "requirement": "应在室内、外转弯处设置广角镜，以保证行走的安全预知性。有推床或推车通过的门和墙面，应采取防碰撞措施。",
        "source": "《儿童医院建设标准》建标174-2016第41条及《综合医院建设标准》第39条",
        "suggestion": "急诊内部转角建议采用高强度透明玻璃墙或设置广角镜。所有墙面阳角必须执行半径大于或等于20mm的圆角工艺。防撞带应分别设在离地0.2m及0.9m两处。"
      },
      {
        "dimension": "无障碍与安全防护",
        "focus": "防触电与门窗限位",
        "requirement": "儿童诊疗区域的门窗、家具和楼地面等应采取必要的安全保护措施。",
        "source": "《综合医院建设标准》建标110-2021第三十九条",
        "suggestion": "所有强电插座高度建议大于或等于1.3m或加装带锁防护盖。所有开启窗必须安装限位器，且开启缝隙宽度应严格控制在10cm以内。"
      },
      {
        "dimension": "无障碍与安全防护",
        "focus": "隐私控制设计",
        "requirement": "检查、治疗用房应满足使用人群的隐私要求，注意开门方向，宜设闭门器。房间内宜设置隔帘或屏风。",
        "source": "《综合医院建设标准》建标110-2021第三十九条",
        "suggestion": "抢救室及清创缝合室的门应具备视觉遮挡功能，开门方向需避免走廊视线直视治疗床。室内天花板必须预留满足全床包围的U型隔帘轨道。"
      }
    ],
    "preview": "assets/img/previews/ed_triage.jpg",
    "glbModel": "glb/er-suite-71.glb",
    "legacySiteModel": "models/model-real.html?space=edClinic",
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 18,
      "priority": "P1",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 20,
      "finalStatus": "未修改到位",
      "finalRequirement": "重建可量测急诊单元平面：公众入口、救护入口、真实墙门和设备外廓；完成前明确关系模型。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "重建单层可量测急诊单元，设置公共步入入口、救护入口、真实墙门和设备外廓。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）",
    "glbModelDisabled": true,
    "glbModelDisabledReason": "2026-07-13 GLB 包围核查发现尺度、原点或游离构件异常；程序场景保留，清理并统一米制重导前禁用实景切换。",
    "glbAuditStatus": "隔离待重导",
    "sceneInfo": {
      "modelScope": "单层可量测程序模型",
      "measurementNotice": "可核对双入口、实体墙门、构件外廓与流线净空；仍非批准施工图，不作为法定合规或设备安装依据。",
      "area": "9.60 × 7.20 m · 净高 3.10m（单层可量测程序模型，约69.1m²）",
      "dims": {
        "def": [
          9.6,
          7.2,
          3.1
        ],
        "min": [
          8.4,
          6,
          2.9
        ],
        "sugg": [
          10.8,
          8.4,
          3.2
        ],
        "minLabel": "小型单元预设",
        "suggLabel": "扩展单元预设"
      },
      "compliance": [
        "公共步入入口与救护入口分开；内部隔墙为实体且均设真实门洞；所有构件保持同一楼层标高。"
      ]
    }
  },
  {
    "id": "ed_waiting",
    "dept": "急诊",
    "name": "公共候诊空间",
    "type": "waiting",
    "priority": "P1",
    "summary": "公共候诊空间审图重点包括“1+N”潮汐候诊极限面积、弹性扩容与平疫转换边界、“1+N”拥堵下的实际疏散净宽等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.4.1及5.2.6条；《综合医院建筑设计标准》GB 51039-2014 第5.1.1条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/急诊/CAD/7.6_急诊集合_t3.dwg"
    ],
    "rules": [
      "area",
      "child",
      "infection",
      "construction"
    ],
    "siteModel": "models/viewer.html?scene=er-waiting",
    "siteModelName": "3D交互信息模型（公共候诊空间·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "公共候诊空间审图重点包括“1+N”潮汐候诊极限面积、弹性扩容与平疫转换边界、“1+N”拥堵下的实际疏散净宽等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.4.1及5.2.6条；《综合医院建筑设计标准》GB 51039-2014 第5.1.1条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "“1+N”潮汐候诊极限面积：候诊处应设面积不小于1.5㎡/人的等候区。儿科候诊区面积应按不小于2㎡/人设计。",
      "弹性扩容与平疫转换边界：医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
      "“1+N”拥堵下的实际疏散净宽：疏散走道、疏散出口的净宽度应满足人员安全疏散的要求。",
      "高等级装修阻燃标准：医疗建筑内部装修材料的燃烧性能等级不应低于A级，部分部位不应低于B1级。",
      "发热与非发热的硬性物理阻断：急诊内传染病门诊和儿科门诊应自成一区，并应设单独出入口。",
      "分区化候诊与座椅背靠背阵列：医疗用房应通风良好。采取有效措施防止交叉感染。"
    ],
    "docReview": [
      "空间模数与弹性 / “1+N”潮汐候诊极限面积：必须按照冬季流感极峰的“满载压力”进行排图。建议单人面积指标放大至2.5㎡至3.0㎡/人。座椅排间距必须大于或等于1.50m，为家长抱着哭闹患儿来回走动安抚预留足够的“物理缓冲槽”。",
      "空间模数与弹性 / 弹性扩容与平疫转换边界：候诊区外围或毗邻的宽阔内街，应在建筑立面与顶面上预留隐蔽的轨道或硬隔离挂点。在“常规模式”下开敞，在“流感爆发模式”下可通过快速拉设物理屏障，瞬间将交通通道转化为临时扩容候诊区。",
      "防火逃生与疏散 / “1+N”拥堵下的实际疏散净宽：候诊区通向室外的疏散通道，在剔除等候座椅、自助机柜、甚至假设通道两侧停满违规婴儿车后，其中央实打实的可通行物理净宽必须绝对≥2.40m（推荐3.00m以上），应对恐慌性踩踏风险。",
      "防火逃生与疏散 / 高等级装修阻燃标准：候诊大厅人员极度密集，吊顶及顶棚必须采用A级不燃材料。墙面所有的适儿化软包及卡通树脂板，必须由厂家出具B1级以上的阻燃检测合格报告，杜绝火灾时的有毒浓烟。",
      "物理边界与感控 / 发热与非发热的硬性物理阻断：在急诊大厅前序阶段，必须使用实体防爆墙将“发热候诊区”与“普通急诊候诊区”进行绝对的物理切分。严禁采用软隔断，彻底阻断流感气溶胶跨区漂移，两条候诊动线绝不交叉。",
      "物理边界与感控 / 分区化候诊与座椅背靠背阵列：候诊座椅严禁采用面对面的“围坐式”布局（极易造成飞沫直射）。必须采用“背靠背”阵列，且座椅靠背高度宜适当加高，形成天然的物理阻沫屏障。",
      "室内声光与安抚 / 高分贝哭闹的声场压制顶棚：急诊候诊区是全院声场混响最恶劣的灾区。吊顶必须满铺NRC（降噪系数）≥0.8的微孔吸音金属板加玻璃纤维棉；大面积墙面1.20m以上部位强制铺设吸音板结构，强行压制群体恐慌性共振。",
      "室内声光与安抚 / 防眩光与昼夜节律照明干预：仰躺在推车或家长怀里的高热患儿对天花板强光极度敏感。严禁使用裸露点光源或强射灯。必须采用深防眩漫反射灯具，且必须具备夜间“柔和微光模式”的独立回路，降低整体暴躁情绪。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与弹性",
        "focus": "“1+N”潮汐候诊极限面积",
        "requirement": "候诊处应设面积不小于1.5㎡/人的等候区。儿科候诊区面积应按不小于2㎡/人设计。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.4.1及5.2.6条",
        "suggestion": "必须按照冬季流感极峰的“满载压力”进行排图。建议单人面积指标放大至2.5㎡至3.0㎡/人。座椅排间距必须大于或等于1.50m，为家长抱着哭闹患儿来回走动安抚预留足够的“物理缓冲槽”。"
      },
      {
        "dimension": "空间模数与弹性",
        "focus": "弹性扩容与平疫转换边界",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "候诊区外围或毗邻的宽阔内街，应在建筑立面与顶面上预留隐蔽的轨道或硬隔离挂点。在“常规模式”下开敞，在“流感爆发模式”下可通过快速拉设物理屏障，瞬间将交通通道转化为临时扩容候诊区。"
      },
      {
        "dimension": "防火逃生与疏散",
        "focus": "“1+N”拥堵下的实际疏散净宽",
        "requirement": "疏散走道、疏散出口的净宽度应满足人员安全疏散的要求。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.4条",
        "suggestion": "候诊区通向室外的疏散通道，在剔除等候座椅、自助机柜、甚至假设通道两侧停满违规婴儿车后，其中央实打实的可通行物理净宽必须绝对≥2.40m（推荐3.00m以上），应对恐慌性踩踏风险。"
      },
      {
        "dimension": "防火逃生与疏散",
        "focus": "高等级装修阻燃标准",
        "requirement": "医疗建筑内部装修材料的燃烧性能等级不应低于A级，部分部位不应低于B1级。",
        "source": "《建筑防火通用规范》GB 55037-2022 第6.1.1条",
        "suggestion": "候诊大厅人员极度密集，吊顶及顶棚必须采用A级不燃材料。墙面所有的适儿化软包及卡通树脂板，必须由厂家出具B1级以上的阻燃检测合格报告，杜绝火灾时的有毒浓烟。"
      },
      {
        "dimension": "物理边界与感控",
        "focus": "发热与非发热的硬性物理阻断",
        "requirement": "急诊内传染病门诊和儿科门诊应自成一区，并应设单独出入口。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.3.1条",
        "suggestion": "在急诊大厅前序阶段，必须使用实体防爆墙将“发热候诊区”与“普通急诊候诊区”进行绝对的物理切分。严禁采用软隔断，彻底阻断流感气溶胶跨区漂移，两条候诊动线绝不交叉。"
      },
      {
        "dimension": "物理边界与感控",
        "focus": "分区化候诊与座椅背靠背阵列",
        "requirement": "医疗用房应通风良好。采取有效措施防止交叉感染。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第7.1.1条",
        "suggestion": "候诊座椅严禁采用面对面的“围坐式”布局（极易造成飞沫直射）。必须采用“背靠背”阵列，且座椅靠背高度宜适当加高，形成天然的物理阻沫屏障。"
      },
      {
        "dimension": "室内声光与安抚",
        "focus": "高分贝哭闹的声场压制顶棚",
        "requirement": "综合医院注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
        "source": "《综合医院建设标准》建标110-2021 第五条",
        "suggestion": "急诊候诊区是全院声场混响最恶劣的灾区。吊顶必须满铺NRC（降噪系数）≥0.8的微孔吸音金属板加玻璃纤维棉；大面积墙面1.20m以上部位强制铺设吸音板结构，强行压制群体恐慌性共振。"
      },
      {
        "dimension": "室内声光与安抚",
        "focus": "防眩光与昼夜节律照明干预",
        "requirement": "医疗用房应采用高显色照明光源。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第8.6.2条",
        "suggestion": "仰躺在推车或家长怀里的高热患儿对天花板强光极度敏感。严禁使用裸露点光源或强射灯。必须采用深防眩漫反射灯具，且必须具备夜间“柔和微光模式”的独立回路，降低整体暴躁情绪。"
      },
      {
        "dimension": "室内声光与安抚",
        "focus": "视听觉阻断与多媒体靶向",
        "requirement": "综合医院的建设应充分考虑使用人群的生理特点。",
        "source": "《综合医院建设标准》建标110-2021 第五条",
        "suggestion": "候诊区墙面必须预留多媒体视屏挂点，中心标高控制在1.00m-1.20m（匹配坐姿或童车内患儿视平线）。利用动画频幕作为“视觉锚点”，有效分散疼痛与漫长等待带来的焦躁。"
      },
      {
        "dimension": "装修构造与防护",
        "focus": "墙裙极限防撞与耐含氯消毒",
        "requirement": "有推床或推车通过的门和墙面，应采取防碰撞措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.12条及第39条（三）",
        "suggestion": "所有立柱、墙角必须做R≥30mm的圆角。墙面从地面起至1.20m高度，必须满铺高硬度、耐高频含氯消毒剂擦洗的医用树脂板（抗倍特板），底部设不锈钢踢脚线防推车碾压破损。"
      },
      {
        "dimension": "装修构造与防护",
        "focus": "无缝地坪与高频呕吐物清理",
        "requirement": "医疗用房的地面、踢脚板、墙面应便于清扫。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.12条",
        "suggestion": "急诊高热患儿极易发生喷射性呕吐。地面严禁使用有拼缝的抛光砖，必须满铺耐磨等级T级、防滑R10的同质透心PVC卷材，热熔无缝焊接，上卷上墙形成一体化防渗漏托盘。"
      }
    ],
    "preview": "assets/img/previews/ed_waiting.jpg",
    "legacySiteModel": "models/model-real.html?space=triage",
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 17,
      "priority": "P1",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 19,
      "finalStatus": "部分完成",
      "finalRequirement": "三号座椅退出门区；补排风构件与状态；候诊人物绑定座椅。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "mt_biochem",
    "dept": "医技",
    "name": "生化检验实验室",
    "type": "lab",
    "priority": "P3",
    "summary": "生化检验实验室审图重点包括流水线无柱大空间跨度、微量血与急诊（STAT）黄金动线、设备后置维保与逃生通道等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.1.1条及4.3.2条；《综合医院建筑设计标准》GB 51039-2014 第5.5.1条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [],
    "rules": [
      "area",
      "privacy",
      "infection",
      "clean"
    ],
    "siteModel": "models/viewer.html?scene=mt-biochem",
    "siteModelName": "3D交互信息模型（生化检验实验室·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "生化检验实验室审图重点包括流水线无柱大空间跨度、微量血与急诊（STAT）黄金动线、设备后置维保与逃生通道等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.1.1条及4.3.2条；《综合医院建筑设计标准》GB 51039-2014 第5.5.1条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "流水线无柱大空间跨度：医疗各项功能用房的设置应符合医疗工艺流程。建筑结构设计应满足医疗设备安装的要求。",
      "微量血与急诊（STAT）黄金动线：检验科应设急诊检验室，并应满足24h工作的要求。",
      "设备后置维保与逃生通道：疏散走道、疏散出口的净宽度应满足人员安全疏散的要求。",
      "精密设备区的特殊灭火预留：建筑内部装修不应擅自减少、改动、拆除、遮挡消防设施。",
      "BSL-2级别感控气密门：实验室的门应有可视窗并可锁闭。应设置闭门器。",
      "核心区独立防火分区墙：医院中的手术部、重症监护室、贵重精密医疗设备用房等，应采用防火隔墙和不燃楼板与其他部位分隔。"
    ],
    "docReview": [
      "空间模数与流线 / 流水线无柱大空间跨度：针对全自动流水线（长达10-20米），建筑平面必须提供进深大于或等于6.00m至8.00m的无柱大空间。严禁在流水线预定轨迹上出现建筑承重柱或剪力墙阻挡轨道延伸。",
      "空间模数与流线 / 微量血与急诊（STAT）黄金动线：微量血标本往往无法上流水线。图纸必须在紧邻标本接收窗的最前端，硬性划定一块“微量血手工操作岛”与“急诊生化专属区”，确保高危/加急标本实现“零距离”上机。",
      "空间模数与流线 / 设备后置维保与逃生通道：流水线背面与建筑实体墙之间，必须强制预留净宽大于或等于0.80m（建议1.00m）的“维保与疏散检修通道”，绝对严禁设备紧贴墙面布置形成死胡同。",
      "防火分隔与感控边界 / 精密设备区的特殊灭火预留：生化实验室内动辄几千万的精密设备严禁水喷淋扑救。建筑顶板及墙面必须为“洁净气体灭火系统（如七氟丙烷）”的管网与泄压口预留实体受力安装点与穿墙孔洞。",
      "防火分隔与感控边界 / BSL-2级别感控气密门：生化室按P2/BSL-2级别建设，主出入口必须为带有多观察窗及闭门器的医用气密门，门下配置自动扫地胶条，确保在关闭状态下维持实验室相对于走廊的微负压防飞沫外溢。",
      "防火分隔与感控边界 / 核心区独立防火分区墙：生化实验室作为检验科内最昂贵的贵重精密医疗设备用房，其四周外围隔墙必须为耐火极限不低于2.00h的防爆防火实体墙，砌筑至结构楼板底。",
      "建筑暗区与防护 / 管线地沟的建筑暗埋封堵：虽然不审机电，但生化线下方密布纯水、废液及数据线。建筑图纸必须为这些管线预留地面暗槽，并标明防腐涂层做法及盖板。穿楼板处必须实施防渗漏与防火双重阻火圈封堵。",
      "建筑暗区与防护 / 强酸碱防腐与洗眼终端：试剂存储区与废液收集区周边2米范围内的墙面与地面，必须采用高等级耐酸碱树脂板或耐腐蚀PVC卷材。区域内必须就近配置连通建筑给水管网的洗眼器与深水槽。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与流线",
        "focus": "流水线无柱大空间跨度",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程。建筑结构设计应满足医疗设备安装的要求。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条及4.3.2条",
        "suggestion": "针对全自动流水线（长达10-20米），建筑平面必须提供进深大于或等于6.00m至8.00m的无柱大空间。严禁在流水线预定轨迹上出现建筑承重柱或剪力墙阻挡轨道延伸。"
      },
      {
        "dimension": "空间模数与流线",
        "focus": "微量血与急诊（STAT）黄金动线",
        "requirement": "检验科应设急诊检验室，并应满足24h工作的要求。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.5.1条",
        "suggestion": "微量血标本往往无法上流水线。图纸必须在紧邻标本接收窗的最前端，硬性划定一块“微量血手工操作岛”与“急诊生化专属区”，确保高危/加急标本实现“零距离”上机。"
      },
      {
        "dimension": "空间模数与流线",
        "focus": "设备后置维保与逃生通道",
        "requirement": "疏散走道、疏散出口的净宽度应满足人员安全疏散的要求。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.4条",
        "suggestion": "流水线背面与建筑实体墙之间，必须强制预留净宽大于或等于0.80m（建议1.00m）的“维保与疏散检修通道”，绝对严禁设备紧贴墙面布置形成死胡同。"
      },
      {
        "dimension": "防火分隔与感控边界",
        "focus": "精密设备区的特殊灭火预留",
        "requirement": "建筑内部装修不应擅自减少、改动、拆除、遮挡消防设施。",
        "source": "《建筑防火通用规范》GB 55037-2022 第6.5.1条",
        "suggestion": "生化实验室内动辄几千万的精密设备严禁水喷淋扑救。建筑顶板及墙面必须为“洁净气体灭火系统（如七氟丙烷）”的管网与泄压口预留实体受力安装点与穿墙孔洞。"
      },
      {
        "dimension": "防火分隔与感控边界",
        "focus": "BSL-2级别感控气密门",
        "requirement": "实验室的门应有可视窗并可锁闭。应设置闭门器。",
        "source": "《实验室 生物安全通用要求》GB 19489-2008 第6.2.5条及第6.3.2条",
        "suggestion": "生化室按P2/BSL-2级别建设，主出入口必须为带有多观察窗及闭门器的医用气密门，门下配置自动扫地胶条，确保在关闭状态下维持实验室相对于走廊的微负压防飞沫外溢。"
      },
      {
        "dimension": "防火分隔与感控边界",
        "focus": "核心区独立防火分区墙",
        "requirement": "医院中的手术部、重症监护室、贵重精密医疗设备用房等，应采用防火隔墙和不燃楼板与其他部位分隔。",
        "source": "《建筑防火通用规范》GB 55037-2022 第4.3.1条",
        "suggestion": "生化实验室作为检验科内最昂贵的贵重精密医疗设备用房，其四周外围隔墙必须为耐火极限不低于2.00h的防爆防火实体墙，砌筑至结构楼板底。"
      },
      {
        "dimension": "建筑暗区与防护",
        "focus": "管线地沟的建筑暗埋封堵",
        "requirement": "建筑内各类管线穿过楼板的孔洞应采用防火封堵材料封堵。",
        "source": "《建筑防火通用规范》GB 55037-2022 第6.3.1条",
        "suggestion": "虽然不审机电，但生化线下方密布纯水、废液及数据线。建筑图纸必须为这些管线预留地面暗槽，并标明防腐涂层做法及盖板。穿楼板处必须实施防渗漏与防火双重阻火圈封堵。"
      },
      {
        "dimension": "建筑暗区与防护",
        "focus": "强酸碱防腐与洗眼终端",
        "requirement": "实验室的墙壁、天花板和地面应耐化学品和消毒剂的腐蚀。应配备紧急洗眼装置。",
        "source": "《实验室 生物安全通用要求》GB 19489-2008 第6.2.2及6.2.8条",
        "suggestion": "试剂存储区与废液收集区周边2米范围内的墙面与地面，必须采用高等级耐酸碱树脂板或耐腐蚀PVC卷材。区域内必须就近配置连通建筑给水管网的洗眼器与深水槽。"
      },
      {
        "dimension": "物理环境",
        "focus": "高频机械噪音的物理吸收",
        "requirement": "综合医院注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点（引申至医护职业防护）。",
        "source": "《综合医院建设标准》建标110-2021 第五条",
        "suggestion": "生化流水线全天候发出机械运转及气泵的高频噪音。实验室吊顶必须满铺高NRC系数（≥0.8）的微孔铝板加吸音棉，墙面宜采用吸音砌块，极力降低室内声场混响时间，保护检验员听力。"
      },
      {
        "dimension": "物理环境",
        "focus": "无影防眩光与高显色照明",
        "requirement": "医疗用房应采用高显色照明光源，显色指数应大于或等于80。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第8.6.2条",
        "suggestion": "检验员需要肉眼比对微量血管中的血清颜色与状态。实验室必须采用显色指数Ra≥90的光源，且灯具排布应与设备操作台平行，采用防眩光格栅，严防试管反光。"
      },
      {
        "dimension": "结构预留与地坪构造",
        "focus": "重型设备楼板极限承重",
        "requirement": "建筑结构设计应满足医疗设备对荷载及安装的要求。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第4.3.2条",
        "suggestion": "生化流水线及配套的大型纯水机组自重极大。机房所处位置的楼板结构承载力必须在图纸上明示大于或等于5.0kN/㎡至8.0kN/㎡（具体须与厂家提供的设备重心点位图二次核对加固）。"
      },
      {
        "dimension": "结构预留与地坪构造",
        "focus": "离心机组绝对抗震地基",
        "requirement": "医疗用房的地面应平整、防滑、易清洁、耐磨、耐腐蚀。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.10条",
        "suggestion": "流水线前处理模块包含多台高速离心机。该区域的地面必须为“实心混凝土硬质地坪（上铺PVC）”，绝对严禁采用网络机房常用的“架空防静电活动地板”，以防离心震动导致溶血。"
      }
    ],
    "legacySiteModel": "models/model-real.html?space=ct",
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 36,
      "priority": "P3",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 38,
      "finalStatus": "部分完成",
      "finalRequirement": "分析设备按模块拆分并标检修面；补试剂/故障状态及桌椅工作关系。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "mt_blood",
    "dept": "医技",
    "name": "采血窗口",
    "type": "treatment",
    "priority": "P3",
    "summary": "采血窗口审图重点包括高低双级操作台面组合、“1+N”抱姿肘部支撑退让、护士腿部避让与防踢空间等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.1.5条；《综合医院建设标准》建标110-2021 第五条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/医技/采血室_t3.dwg"
    ],
    "rules": [
      "child",
      "infection",
      "accessible"
    ],
    "siteModel": "models/viewer.html?scene=mt-blood",
    "siteModelName": "3D交互信息模型（采血窗口·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "采血窗口审图重点包括高低双级操作台面组合、“1+N”抱姿肘部支撑退让、护士腿部避让与防踢空间等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.1.5条；《综合医院建设标准》建标110-2021 第五条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "高低双级操作台面组合：有轮椅通行的门和走道以及服务台等，应满足无障碍设施的规定。",
      "“1+N”抱姿肘部支撑退让：综合医院注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
      "护士腿部避让与防踢空间：医疗各项功能用房的设置应符合医疗工艺流程。",
      "防飞沫与防抓挠物理屏障：医疗用房应通风良好。采取有效措施防止交叉感染。",
      "台面内嵌式“盲抛”孔洞：医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理、洁污路线清楚。",
      "背墙/侧墙标本传递界面：医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理、洁污路线清楚。"
    ],
    "docReview": [
      "人机工效与模数 / 高低双级操作台面组合：单排采血窗口必须硬性包含两种高度模数：1. 常规高台位（高度约0.75m-0.80m），专供家长抱持婴幼儿时站立或高脚凳就坐；2. 低台位（高度≤0.70m且下方留空），专供大龄儿童端坐或轮椅无障碍推入。",
      "人机工效与模数 / “1+N”抱姿肘部支撑退让：采血台面向患儿侧的进深必须大于或等于0.40m。确保家长在实施“怀抱锁喉式”固定时，双臂手肘能完全支撑在坚固的台面上，严防穿刺瞬间因手臂悬空无力导致针头偏离划伤。",
      "人机工效与模数 / 护士腿部避让与防踢空间：采血台底部的立面挡板必须向护士侧内退至少0.25m。既为护士提供长时间坐姿的腿部伸展空间，又形成物理距离，防止抗拒采血的大龄儿童隔着柜台踢踹护士膝盖。",
      "物理边界与感控 / 防飞沫与防抓挠物理屏障：台面上方必须安装全封闭或大半封闭的透明钢化玻璃。底部仅留出高度约0.15m-0.20m的操作缝隙。此缝隙高度既能让护士双手与采血管通过，又能绝对阻挡患儿突然伸手抓挠护士面部或抢夺针管。",
      "物理边界与感控 / 台面内嵌式“盲抛”孔洞：采血台面的护士“右手黄金操作区”，必须精确定位并开孔预留“隐蔽式利器盒落孔”与“医疗废物桶落孔”。拔针后护士手腕微转即可盲抛，废弃物瞬间消失于患儿视野，彻底斩断视觉污染与触碰风险。",
      "物流界面预留 / 背墙/侧墙标本传递界面：护士坐姿背后的实体墙面，必须按窗口点位一对一预留标本传递槽或机械互锁传递窗。护士转身即可将试管推入后方检验核心区，严禁血液标本在护士前台桌面上大量堆积。",
      "室内装修 / 操作台极限防渗漏收口：台面必须采用无缝拼接的医用抗菌人造石或抗倍特板。边缘所有阳角必须做R≥20mm的大圆弧处理。台面靠墙处及外缘必须做一体成型的“防溢水挡水条”，彻底杜绝血液顺缝隙滴漏至柜内发臭。",
      "室内装修 / 立面抗污与踢脚线防护：采血台外立面频繁遭受婴儿车撞击及鞋印污染。严禁采用易脏的白色涂料或木饰面，必须采用低饱和度暖色调的抗划痕医用树脂板，底部0.15m需设置不锈钢防撞踢脚基座。"
    ],
    "docReviewRows": [
      {
        "dimension": "人机工效与模数",
        "focus": "高低双级操作台面组合",
        "requirement": "有轮椅通行的门和走道以及服务台等，应满足无障碍设施的规定。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.5条",
        "suggestion": "单排采血窗口必须硬性包含两种高度模数：1. 常规高台位（高度约0.75m-0.80m），专供家长抱持婴幼儿时站立或高脚凳就坐；2. 低台位（高度≤0.70m且下方留空），专供大龄儿童端坐或轮椅无障碍推入。"
      },
      {
        "dimension": "人机工效与模数",
        "focus": "“1+N”抱姿肘部支撑退让",
        "requirement": "综合医院注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
        "source": "《综合医院建设标准》建标110-2021 第五条",
        "suggestion": "采血台面向患儿侧的进深必须大于或等于0.40m。确保家长在实施“怀抱锁喉式”固定时，双臂手肘能完全支撑在坚固的台面上，严防穿刺瞬间因手臂悬空无力导致针头偏离划伤。"
      },
      {
        "dimension": "人机工效与模数",
        "focus": "护士腿部避让与防踢空间",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "采血台底部的立面挡板必须向护士侧内退至少0.25m。既为护士提供长时间坐姿的腿部伸展空间，又形成物理距离，防止抗拒采血的大龄儿童隔着柜台踢踹护士膝盖。"
      },
      {
        "dimension": "物理边界与感控",
        "focus": "防飞沫与防抓挠物理屏障",
        "requirement": "医疗用房应通风良好。采取有效措施防止交叉感染。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第7.1.1条",
        "suggestion": "台面上方必须安装全封闭或大半封闭的透明钢化玻璃。底部仅留出高度约0.15m-0.20m的操作缝隙。此缝隙高度既能让护士双手与采血管通过，又能绝对阻挡患儿突然伸手抓挠护士面部或抢夺针管。"
      },
      {
        "dimension": "物理边界与感控",
        "focus": "台面内嵌式“盲抛”孔洞",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理、洁污路线清楚。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "采血台面的护士“右手黄金操作区”，必须精确定位并开孔预留“隐蔽式利器盒落孔”与“医疗废物桶落孔”。拔针后护士手腕微转即可盲抛，废弃物瞬间消失于患儿视野，彻底斩断视觉污染与触碰风险。"
      },
      {
        "dimension": "物流界面预留",
        "focus": "背墙/侧墙标本传递界面",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理、洁污路线清楚。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "护士坐姿背后的实体墙面，必须按窗口点位一对一预留标本传递槽或机械互锁传递窗。护士转身即可将试管推入后方检验核心区，严禁血液标本在护士前台桌面上大量堆积。"
      },
      {
        "dimension": "室内装修",
        "focus": "操作台极限防渗漏收口",
        "requirement": "医疗用房的地面、踢脚板、墙裙、墙面、顶棚应便于清扫或冲洗。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.12条",
        "suggestion": "台面必须采用无缝拼接的医用抗菌人造石或抗倍特板。边缘所有阳角必须做R≥20mm的大圆弧处理。台面靠墙处及外缘必须做一体成型的“防溢水挡水条”，彻底杜绝血液顺缝隙滴漏至柜内发臭。"
      },
      {
        "dimension": "室内装修",
        "focus": "立面抗污与踢脚线防护",
        "requirement": "有推床或推车通过的门和墙面，应采取防碰撞措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.12条",
        "suggestion": "采血台外立面频繁遭受婴儿车撞击及鞋印污染。严禁采用易脏的白色涂料或木饰面，必须采用低饱和度暖色调的抗划痕医用树脂板，底部0.15m需设置不锈钢防撞踢脚基座。"
      },
      {
        "dimension": "视听觉阻断干预",
        "focus": "工位间声学与视觉隔断",
        "requirement": "综合医院注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
        "source": "《综合医院建设标准》建标110-2021 第五条",
        "suggestion": "相邻采血窗口之间，在台面上方应设置向外伸出深度约0.40m的磨砂玻璃或吸音隔板。阻断相邻排队患儿看到前一名患儿被扎针出血的血腥画面，切断候诊区的“恐慌情绪传染链”。"
      },
      {
        "dimension": "视听觉阻断干预",
        "focus": "视线黄金位的多媒体锚定",
        "requirement": "综合医院的建设在满足各项功能需要的同时，注重改善患者的就医环境。",
        "source": "《综合医院建设标准》建标110-2021 第五条",
        "suggestion": "必须在采血窗口上方（玻璃防飞沫板顶部或吊顶下挂处），精确预留多媒体视屏挂点。屏幕中心标高严格控制在1.10m-1.30m，确保患儿在采血操作期间，视线被正前方的动画片死死“锚定”，降低痛觉感知。"
      }
    ],
    "legacySiteModel": "models/model-real.html?space=clinic",
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 29,
      "priority": "P3",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 31,
      "finalStatus": "部分完成",
      "finalRequirement": "采血单元退出门区；补晕厥处置床；桌椅建立工作接触；传递口位于实体隔墙。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "mt_bone",
    "dept": "医技",
    "name": "骨密度室",
    "type": "imaging",
    "priority": "P2",
    "summary": "骨密度室按“低剂量检查床、扫描臂、控制观察、更衣隐私、低剂量告知”组织；3D模型已补入DEXA床、扫描臂、控制屏、更衣座椅、隐私屏风、低剂量警示、数据流和舒适送回风。",
    "assets": [
      "docs/materials/医技/骨密度_t3.dwg"
    ],
    "rules": [
      "radiation",
      "accessible",
      "construction"
    ],
    "siteModel": "models/viewer.html?scene=mt-bone",
    "siteModelName": "3D交互信息模型（骨密度室·新版）",
    "legacySiteModel": "models/model-real.html?space=ct",
    "docBehaviors": [
      "受检者在更衣/等候位完成隐私准备，进入检查床定位后由技师在控制侧完成扫描。",
      "控制位不侵入检查区，低剂量X线告知与陪护等待位置布置在扫描边界外。",
      "检查完成后按原路径离开，避免与下一名更衣受检者交叉。"
    ],
    "docFacts": [
      "3D模型新增骨密度检查床、扫描臂、控制屏、隐私屏风和低剂量X线提示。",
      "模型用地面净距框表达检查床周边操作范围，避免小房间内控制台侵占扫描区。",
      "模型用数据流表达“检查床→控制台→报告”，用送回风动画表达舒适环境。"
    ],
    "docReview": [
      "3D信息模型核查 / 小房间内的隐私与低剂量边界：骨密度室面积小，更容易把更衣、控制和检查混成一团；模型必须明确隐私屏风与控制边界。"
    ],
    "docReviewRows": [
      {
        "dimension": "3D信息模型表达",
        "focus": "低剂量检查与更衣隐私并置",
        "requirement": "模型应表达DEXA床、扫描臂、控制屏、隐私屏风、低剂量告知和数据流。",
        "source": "项目3D信息模型深化校核项（参考儿童手术室独立模型的空间边界、设备附件、流线动画和工程接口颗粒度）",
        "suggestion": "骨密度室不能只画一张床；应能看出受检者更衣、上床定位、扫描、离开的完整闭环。"
      },
      {
        "dimension": "空间净距",
        "focus": "控制位不侵入扫描区",
        "requirement": "控制操作位置应避开受检者上床、转身和离床路径。",
        "source": "项目3D信息模型深化校核项（参考儿童手术室独立模型的空间边界、设备附件、流线动画和工程接口颗粒度）",
        "suggestion": "利用模型地面净距框检查控制台、屏风和床端是否互相打架，尤其要避免轮椅患者无法靠近检查床。"
      }
    ],
    "modelDetail": {
      "referenceGranularity": "参照儿童手术室模型对隐性流程的表达，把小型骨密度室也拆成检查、控制、更衣、告知、数据五类信息。",
      "roomZones": [
        "低剂量检查区",
        "控制观察区",
        "更衣/等候位",
        "手卫生/观察恢复",
        "设备热量排出路径"
      ],
      "equipment": [
        "DEXA检查床",
        "扫描臂",
        "控制屏",
        "隐私屏风",
        "低剂量警示牌",
        "PACS数据接口"
      ],
      "animatedFlows": [
        "更衣→上床定位→扫描→离开",
        "技师控制观察",
        "影像数据回传",
        "舒适送风与回风"
      ],
      "checkPoints": [
        "更衣隐私",
        "床侧净距",
        "低剂量告知",
        "控制台不侵入检查区"
      ]
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 31,
      "priority": "P2",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 33,
      "finalStatus": "部分完成",
      "finalRequirement": "隐私设施退出门区；补门禁/检修状态和检修投影区。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "mt_cold_storage",
    "dept": "医技",
    "name": "试剂冷库",
    "type": "lab",
    "priority": "P3",
    "summary": "试剂冷库审图重点包括密集型货架极限楼板承重、库体拼装净空与周边退让、高等级阻燃保温芯材等内容；依据《综合医院建筑设计标准》GB 51039-2014 第4.3.2条；《综合医院建筑设计标准》GB 51039-2014 第5.1.1条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [],
    "rules": [
      "area",
      "construction"
    ],
    "siteModel": "models/viewer.html?scene=mt-cold-storage",
    "siteModelName": "3D交互信息模型（试剂冷库·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "试剂冷库审图重点包括密集型货架极限楼板承重、库体拼装净空与周边退让、高等级阻燃保温芯材等内容；依据《综合医院建筑设计标准》GB 51039-2014 第4.3.2条；《综合医院建筑设计标准》GB 51039-2014 第5.1.1条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "密集型货架极限楼板承重：建筑结构设计应满足医疗设备及仓储对荷载及安装的要求。",
      "库体拼装净空与周边退让：医疗各项功能用房的设置应符合医疗工艺流程。",
      "高等级阻燃保温芯材：建筑内部保温材料的燃烧性能应符合规定。冷库库房的隔热材料燃烧性能不应低于B1级。",
      "库房独立防火与防爆分隔：医院中的贵重精密医疗设备用房、化学试剂库等，应采用防火隔墙和其他部位分隔。",
      "穿板孔洞的高严密保温封堵：建筑内各类管线穿过防火墙、隔墙、楼板的孔洞应采用防火封堵材料封堵。",
      "防冷桥的结构降板与零门槛：通向推床的门净宽不应小于1.10m，且不应设置门槛。"
    ],
    "docReview": [
      "空间模数与荷载 / 密集型货架极限楼板承重：试剂冷库内部通常采用高密度移动货架或重型搁板。建筑结构审查时，该区域的楼板活荷载标准值必须硬性规定在5.0kN/㎡至8.0kN/㎡以上，严防楼板开裂变形。",
      "空间模数与荷载 / 库体拼装净空与周边退让：建筑平面与剖面不能按“墙到墙”计算。冷库库体（通常为厚度100mm-150mm的聚氨酯保温库板）与建筑原实体墙面、顶板之间，必须预留至少0.20m至0.30m的通风防潮与拼装施工间隙。",
      "防火分隔与阻燃 / 高等级阻燃保温芯材：材料表中，冷库六面体拼装板的芯材（通常为聚氨酯 PU 或聚异氰脲酸酯 PIR），必须提供由国家级检测机构出具的B1级（难燃）及以上防火检测报告，严禁使用易燃的普通泡沫彩钢板。",
      "防火分隔与阻燃 / 库房独立防火与防爆分隔：试剂冷库集中存放了全科室最昂贵的物资，且部分试剂含有醇类等易燃成分。其建筑外围必须采用耐火极限不低于2.00h的实体防火隔墙进行全封闭包围。",
      "防火分隔与阻燃 / 穿板孔洞的高严密保温封堵：所有穿越冷库保温板的制冷铜管、监控弱电线缆穿孔，必须使用耐低温的聚氨酯发泡剂进行深度填缝，外部再涂抹防火泥。实现“隔热、隔汽（防冷凝水漏入库体夹层）、防火”三重复合封堵。",
      "物理界面与保温构造 / 防冷桥的结构降板与零门槛：为保证试剂推车“零门槛”顺畅进出，冷库地面的最终完成面必须与走廊平齐。建筑结构图纸必须在该区域设计厚度约0.15m-0.20m的“结构降板”，用于暗埋冷库地面的保温板与防冻胀垫层。",
      "物理界面与保温构造 / 冷热交界面与结露缓冲间：在温差极大的南方或高湿地区，冷库大门外侧必须设置一个建筑实体“缓冲间”。防止冷库门开启时，冷气外溢直接遇到外部走廊热空气，导致整个走廊墙面和地面产生严重的冷凝结露。",
      "安全防护与人机工效 / 冷库门内部防反锁逃生机械：图纸选型中的冷库库门，必须硬性要求配备“带有夜光标识的内部机械脱险推杆”。确保库门即使在外部被挂锁死锁，内部被困检验员也能通过撞击或推拉机械杆强行破门逃生。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与荷载",
        "focus": "密集型货架极限楼板承重",
        "requirement": "建筑结构设计应满足医疗设备及仓储对荷载及安装的要求。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第4.3.2条",
        "suggestion": "试剂冷库内部通常采用高密度移动货架或重型搁板。建筑结构审查时，该区域的楼板活荷载标准值必须硬性规定在5.0kN/㎡至8.0kN/㎡以上，严防楼板开裂变形。"
      },
      {
        "dimension": "空间模数与荷载",
        "focus": "库体拼装净空与周边退让",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "建筑平面与剖面不能按“墙到墙”计算。冷库库体（通常为厚度100mm-150mm的聚氨酯保温库板）与建筑原实体墙面、顶板之间，必须预留至少0.20m至0.30m的通风防潮与拼装施工间隙。"
      },
      {
        "dimension": "防火分隔与阻燃",
        "focus": "高等级阻燃保温芯材",
        "requirement": "建筑内部保温材料的燃烧性能应符合规定。冷库库房的隔热材料燃烧性能不应低于B1级。",
        "source": "《建筑防火通用规范》GB 55037-2022 第6.1.1条及《冷库设计标准》第4.2.2条",
        "suggestion": "材料表中，冷库六面体拼装板的芯材（通常为聚氨酯 PU 或聚异氰脲酸酯 PIR），必须提供由国家级检测机构出具的B1级（难燃）及以上防火检测报告，严禁使用易燃的普通泡沫彩钢板。"
      },
      {
        "dimension": "防火分隔与阻燃",
        "focus": "库房独立防火与防爆分隔",
        "requirement": "医院中的贵重精密医疗设备用房、化学试剂库等，应采用防火隔墙和其他部位分隔。",
        "source": "《建筑防火通用规范》GB 55037-2022 第4.3.1条",
        "suggestion": "试剂冷库集中存放了全科室最昂贵的物资，且部分试剂含有醇类等易燃成分。其建筑外围必须采用耐火极限不低于2.00h的实体防火隔墙进行全封闭包围。"
      },
      {
        "dimension": "防火分隔与阻燃",
        "focus": "穿板孔洞的高严密保温封堵",
        "requirement": "建筑内各类管线穿过防火墙、隔墙、楼板的孔洞应采用防火封堵材料封堵。",
        "source": "《建筑防火通用规范》GB 55037-2022 第6.3.1条",
        "suggestion": "所有穿越冷库保温板的制冷铜管、监控弱电线缆穿孔，必须使用耐低温的聚氨酯发泡剂进行深度填缝，外部再涂抹防火泥。实现“隔热、隔汽（防冷凝水漏入库体夹层）、防火”三重复合封堵。"
      },
      {
        "dimension": "物理界面与保温构造",
        "focus": "防冷桥的结构降板与零门槛",
        "requirement": "通向推床的门净宽不应小于1.10m，且不应设置门槛。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.4条",
        "suggestion": "为保证试剂推车“零门槛”顺畅进出，冷库地面的最终完成面必须与走廊平齐。建筑结构图纸必须在该区域设计厚度约0.15m-0.20m的“结构降板”，用于暗埋冷库地面的保温板与防冻胀垫层。"
      },
      {
        "dimension": "物理界面与保温构造",
        "focus": "冷热交界面与结露缓冲间",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "在温差极大的南方或高湿地区，冷库大门外侧必须设置一个建筑实体“缓冲间”。防止冷库门开启时，冷气外溢直接遇到外部走廊热空气，导致整个走廊墙面和地面产生严重的冷凝结露。"
      },
      {
        "dimension": "安全防护与人机工效",
        "focus": "冷库门内部防反锁逃生机械",
        "requirement": "冷库门应能从内部打开，并应设有醒目的内部开启标识。冷库内应设置呼救按钮。",
        "source": "《冷库设计标准》GB 50072-2021 第4.2.14条及《安全生产法》",
        "suggestion": "图纸选型中的冷库库门，必须硬性要求配备“带有夜光标识的内部机械脱险推杆”。确保库门即使在外部被挂锁死锁，内部被困检验员也能通过撞击或推拉机械杆强行破门逃生。"
      },
      {
        "dimension": "安全防护与人机工效",
        "focus": "极限防滑与抗冻裂地材",
        "requirement": "医疗用房的地面应平整、防滑、易清洁、耐磨、耐腐蚀、不产尘。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.10条",
        "suggestion": "冷库地面常伴随微量结冰或冷凝水，极易滑倒。地面严禁铺设普通瓷砖，必须采用表面带有防滑凸起的厚底防滑铝花纹板，或满铺高摩擦系数的防滑耐冻环氧树脂地坪，接缝必须打耐低温硅酮胶。"
      }
    ],
    "legacySiteModel": "models/model-real.html?space=ct",
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 37,
      "priority": "P3",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 39,
      "finalStatus": "未修改到位",
      "finalRequirement": "冷库门嵌入真实墙体，补库内逃生装置；货架留主通道和检修面；补操作人员。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "建立真实冷库围护、门与逃生装置，整理货架主通道、操作位和检修面。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "mt_control",
    "dept": "医技",
    "name": "医生控制室",
    "type": "imaging",
    "priority": "P3",
    "summary": "医生控制室作为影像科后台枢纽，应同时服务操作、观察、报告、数据和设备散热；3D模型表达集中操作台、PACS/RIS工作站、防护/RF观察窗、服务器机柜、技师工作流、影像数据流和控制室排热。",
    "assets": [],
    "rules": [
      "area",
      "child",
      "infection",
      "radiation"
    ],
    "siteModel": "models/viewer.html?scene=mt-control",
    "siteModelName": "3D交互信息模型（医生控制室·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "医生控制室审图重点包括单机或集中操作空间界限、医患绝对分流的独立出入口、操作台底部地沟双重封堵等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.1.1条；《综合医院建筑设计标准》GB 51039-2014 第5.4.1条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "单机或集中操作空间界限：医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
      "医患绝对分流的独立出入口：放射科、核医学科、超声科等医技科室，应设医护人员专用通道。",
      "操作台底部地沟双重封堵：建筑内各类管线穿过防火墙、防火隔墙、楼板的孔洞应采用防火封堵材料封堵，封堵的耐火性能不应低于相应分隔构件的耐火性能。",
      "装修材料高阻燃标准：医疗建筑内部装修材料的燃烧性能等级不应低于A级，部分部位不应低于B1级。",
      "双开门疏散净宽：疏散走道、疏散出口的净宽度应满足人员安全疏散的要求。",
      "防辐射观察窗绝对无死角：有防辐射要求的用房，其建筑构造应符合国家现行有关放射防护标准的规定。"
    ],
    "docReview": [
      "空间模数与流线 / 单机或集中操作空间界限：单台设备的控制室净使用面积不宜小于10.00㎡。若为“一控二”（一个控制室操作两台CT/MRI）的集中布局，面积不应小于20.00㎡，且两台设备操作台背向距离必须大于或等于1.50m，防止技师背靠背工作时发生椅背碰撞。",
      "空间模数与流线 / 医患绝对分流的独立出入口：控制室的大门必须且只能开向“内侧医护专用走廊”，严禁直接向外侧“患儿公共候诊走廊”开门。确保医生在阅片或操作时不被外部焦躁的家属打扰或窥视。",
      "防火分隔与封堵 / 操作台底部地沟双重封堵：扫描室主机连向控制室操作台的粗大线缆，通过建筑预留地沟穿墙。该穿墙部位必须使用“防火+防辐射”双重功效的重晶石阻火泥进行全密实柔性封堵，彻底阻断火灾烟气与X射线泄漏。",
      "防火分隔与封堵 / 装修材料高阻燃标准：控制室内集中了极其昂贵的IT工作站，其吊顶、墙面基层及抗静电地板必须全部采用A级不燃材料，严禁采用普通木作包边等易燃装饰。",
      "防火分隔与封堵 / 双开门疏散净宽：控制室通向内部走廊的门净宽不应小于1.00m。若是“一控二”或“一控三”的大型集中控制室，人员密集且设备繁多，主出入口必须为向疏散方向开启的平开门，且地面零门槛。",
      "人机工学与视线 / 防辐射观察窗绝对无死角：铅玻璃或射频屏蔽玻璃的水平位置必须正对扫描床。图纸上必须画出“视线包络图”，确保技师在坐姿状态下，视线能够完整覆盖检查床的头尾两端，以及站在床侧陪护的家长。",
      "人机工学与视线 / 视平线与窗台标高控制：观察窗的窗台下沿（完成面）标高必须严格控制在0.80m至0.90m之间，以完美衔接操作台桌面的高度（通常为0.75m），严防窗台过高导致技师必须站立才能看清患儿。",
      "物理环境 / 高分贝噪音隔离与声学顶棚：针对CT/MRI机房传来的剧烈震动噪音，控制室与扫描室之间的隔墙必须为高强度实体隔音墙。控制室天花板建议采用NRC系数大于0.7的微孔吸音金属板，为医生提供安静的阅片诊断环境。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与流线",
        "focus": "单机或集中操作空间界限",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "单台设备的控制室净使用面积不宜小于10.00㎡。若为“一控二”（一个控制室操作两台CT/MRI）的集中布局，面积不应小于20.00㎡，且两台设备操作台背向距离必须大于或等于1.50m，防止技师背靠背工作时发生椅背碰撞。"
      },
      {
        "dimension": "空间模数与流线",
        "focus": "医患绝对分流的独立出入口",
        "requirement": "放射科、核医学科、超声科等医技科室，应设医护人员专用通道。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.4.1条",
        "suggestion": "控制室的大门必须且只能开向“内侧医护专用走廊”，严禁直接向外侧“患儿公共候诊走廊”开门。确保医生在阅片或操作时不被外部焦躁的家属打扰或窥视。"
      },
      {
        "dimension": "防火分隔与封堵",
        "focus": "操作台底部地沟双重封堵",
        "requirement": "建筑内各类管线穿过防火墙、防火隔墙、楼板的孔洞应采用防火封堵材料封堵，封堵的耐火性能不应低于相应分隔构件的耐火性能。",
        "source": "《建筑防火通用规范》GB 55037-2022 第6.3.1条",
        "suggestion": "扫描室主机连向控制室操作台的粗大线缆，通过建筑预留地沟穿墙。该穿墙部位必须使用“防火+防辐射”双重功效的重晶石阻火泥进行全密实柔性封堵，彻底阻断火灾烟气与X射线泄漏。"
      },
      {
        "dimension": "防火分隔与封堵",
        "focus": "装修材料高阻燃标准",
        "requirement": "医疗建筑内部装修材料的燃烧性能等级不应低于A级，部分部位不应低于B1级。",
        "source": "《建筑防火通用规范》GB 55037-2022 第6.1.1条",
        "suggestion": "控制室内集中了极其昂贵的IT工作站，其吊顶、墙面基层及抗静电地板必须全部采用A级不燃材料，严禁采用普通木作包边等易燃装饰。"
      },
      {
        "dimension": "防火分隔与封堵",
        "focus": "双开门疏散净宽",
        "requirement": "疏散走道、疏散出口的净宽度应满足人员安全疏散的要求。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.4条",
        "suggestion": "控制室通向内部走廊的门净宽不应小于1.00m。若是“一控二”或“一控三”的大型集中控制室，人员密集且设备繁多，主出入口必须为向疏散方向开启的平开门，且地面零门槛。"
      },
      {
        "dimension": "人机工学与视线",
        "focus": "防辐射观察窗绝对无死角",
        "requirement": "有防辐射要求的用房，其建筑构造应符合国家现行有关放射防护标准的规定。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.13条",
        "suggestion": "铅玻璃或射频屏蔽玻璃的水平位置必须正对扫描床。图纸上必须画出“视线包络图”，确保技师在坐姿状态下，视线能够完整覆盖检查床的头尾两端，以及站在床侧陪护的家长。"
      },
      {
        "dimension": "人机工学与视线",
        "focus": "视平线与窗台标高控制",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "观察窗的窗台下沿（完成面）标高必须严格控制在0.80m至0.90m之间，以完美衔接操作台桌面的高度（通常为0.75m），严防窗台过高导致技师必须站立才能看清患儿。"
      },
      {
        "dimension": "物理环境",
        "focus": "高分贝噪音隔离与声学顶棚",
        "requirement": "综合医院注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
        "source": "《综合医院建设标准》建标110-2021 第五条",
        "suggestion": "针对CT/MRI机房传来的剧烈震动噪音，控制室与扫描室之间的隔墙必须为高强度实体隔音墙。控制室天花板建议采用NRC系数大于0.7的微孔吸音金属板，为医生提供安静的阅片诊断环境。"
      },
      {
        "dimension": "物理环境",
        "focus": "防眩光与多层级阅片照明",
        "requirement": "医疗用房应采用高显色照明光源，显色指数应大于或等于80。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第8.6.2条",
        "suggestion": "控制室内满布高亮度的医疗显示器。室内严禁使用直射点光源或高流明面光源。必须配置深防眩漫反射格栅灯，且必须支持“操作模式（暗光）”与“保洁模式（亮光）”的独立回路切换，杜绝屏幕反光。"
      },
      {
        "dimension": "物理防护与建筑构造",
        "focus": "观察窗边框防辐射极限搭接",
        "requirement": "有防辐射要求的用房，其建筑构造应符合国家现行有关放射防护标准的规定。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.13条",
        "suggestion": "控制室这侧的铅玻璃窗框，其内部包裹的铅板，必须与墙体原有的防辐射硫酸钡或铅板形成大于或等于20mm的物理重叠搭接。大样图若画成“平齐对接”，则存在极高的直线漏射线风险。"
      },
      {
        "dimension": "物理防护与建筑构造",
        "focus": "机房互通重型防护门",
        "requirement": "有防辐射要求的用房，其建筑构造应符合国家现行有关放射防护标准的规定。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.13条",
        "suggestion": "如果控制室与扫描室之间设有直通的内门，该门必须为达到同等铅当量的防辐射重型门，且必须向扫描室方向外开，配置高强度闭门器，确保检查时绝对关闭。"
      }
    ],
    "legacySiteModel": "models/model-real.html?space=ct",
    "docBehaviors": [
      "技师从医护后台进入控制室，完成设备操作、患者观察、语音指导和报告处理。",
      "控制室通过铅玻璃或RF观察窗与机房保持视觉联系，但门禁不直接开向公共候诊。",
      "PACS/RIS服务器与弱电设备柜集中散热，避免把控制室变成无组织机柜仓库。"
    ],
    "modelDetail": {
      "referenceGranularity": "参照儿童手术室模型对控制面板、监测和隐性系统的表达，强化控制室的观察、数据和后台设备属性。",
      "roomZones": [
        "集中操作台",
        "报告/PACS工作站",
        "医护入口/报告",
        "服务器/弱电散热",
        "防护/RF观察窗"
      ],
      "equipment": [
        "多屏控制台",
        "报告工作站",
        "防护/RF观察窗",
        "PACS/弱电设备柜",
        "语音/监控接口"
      ],
      "animatedFlows": [
        "技师工作流",
        "影像数据流",
        "控制室送风与设备排热"
      ],
      "checkPoints": [
        "坐姿视线",
        "医患分流",
        "屏幕与椅背退让",
        "服务器散热",
        "观察窗搭接"
      ]
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 40,
      "priority": "P3",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 42,
      "finalStatus": "部分完成",
      "finalRequirement": "服务器移入设备间；控制台、观察窗和数据设备形成可切换状态。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "mt_ct",
    "dept": "医技",
    "name": "CT扫描间",
    "type": "imaging",
    "priority": "P0",
    "summary": "CT扫描间以“扫描室、控制室、设备/计算机间、准备/观察位”四块组织；3D模型已补入CT机架、滑移床、激光定位、高压注射器、铅衣架、镇静监护、Z型线缆地沟、PACS控制台、影像数据流、医用气体/造影剂流和设备排热气流。",
    "assets": [],
    "rules": [
      "area",
      "privacy",
      "child",
      "infection"
    ],
    "siteModel": "models/viewer.html?scene=mt-ct",
    "siteModelName": "3D交互信息模型（CT扫描间·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "CT扫描间审图重点包括三室分离与面积底线、操作视线与无死角监控、家属陪护操作面预留等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.1.1条；《综合医院建设标准》建标110-2021 第五条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "三室分离与面积底线：医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理、洁污路线清楚。",
      "操作视线与无死角监控：医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
      "家属陪护操作面预留：综合医院注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
      "防辐射重型门的逃生设计：疏散出口门、疏散走道中的门应向疏散方向开启。",
      "机房独立防火分隔：医院中的手术部、急诊部、重症监护室、贵重精密医疗设备用房等，应采用防火隔墙和不燃楼板与其他部位分隔。",
      "地沟与孔洞防火封堵：建筑内各类管线穿过防火墙、防火隔墙、楼板的孔洞应采用防火封堵材料封堵，封堵的耐火性能不应低于相应分隔构件的耐火性能。"
    ],
    "docReview": [
      "空间模数与布局 / 三室分离与面积底线：CT机房必须划分为“扫描室、控制室、设备间”。扫描室单间净使用面积不应小于30.00㎡（若为双源CT或大孔径CT需按厂家图纸放大至40.00㎡），控制室面积不宜小于10.00㎡。",
      "空间模数与布局 / 操作视线与无死角监控：控制室与扫描室之间的隔墙上必须设置防辐射铅玻璃观察窗。观察窗的位置必须确保技师在坐姿操作时，视线能完整覆盖整个CT检查床及扫描孔，无建筑遮挡死角。",
      "空间模数与布局 / 家属陪护操作面预留：考虑到低龄患儿需要家属穿着铅衣在床旁安抚，检查床侧边及尾部必须预留宽度大于或等于1.20m的净操作空间，严禁设备贴墙布置导致家属无处站立。",
      "防火分隔与逃生 / 防辐射重型门的逃生设计：CT室的主防护门为电动平移铅门（重达数百公斤）。图纸必须强制要求该电动门配置断电后可手动轻松推拉的机械脱轨装置，或在扫描室另设一扇带闭门器的普通材质外开逃生门（内部加贴相应当量铅板）。",
      "防火分隔与逃生 / 机房独立防火分隔：CT室作为贵重精密医疗设备用房，其机房外围封闭墙体必须同时满足“防辐射”与“耐火极限不低于2.00h”的双重物理属性。",
      "防火分隔与逃生 / 地沟与孔洞防火封堵：穿越控制室与扫描室之间隔墙的所有建筑地沟、弱电过线管穿墙孔洞，在管线敷设完毕后，必须使用防火泥或防火膨胀模块进行全密实柔性封堵，彻底杜绝火灾烟气串流。",
      "防火分隔与逃生 / 零门槛推床顺畅度：主防辐射门开启后的净宽建议大于或等于1.40m。门下地面必须绝对零门槛平接，电动铅门的下部导向轨应采用极浅的地面暗槽，确保病床平稳推入，不引发镇静患儿的惊跳反射。",
      "室内装修与防撞 / 地材高荷载与抗造防滑：CT设备极重且推床进出频繁，地面必须采用承载力极高、防滑等级R10以上的2.0mm同质透心PVC卷材或橡胶地板。严禁使用极易被推床碾碎的架空防静电地板。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与布局",
        "focus": "三室分离与面积底线",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理、洁污路线清楚。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "CT机房必须划分为“扫描室、控制室、设备间”。扫描室单间净使用面积不应小于30.00㎡（若为双源CT或大孔径CT需按厂家图纸放大至40.00㎡），控制室面积不宜小于10.00㎡。"
      },
      {
        "dimension": "空间模数与布局",
        "focus": "操作视线与无死角监控",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "控制室与扫描室之间的隔墙上必须设置防辐射铅玻璃观察窗。观察窗的位置必须确保技师在坐姿操作时，视线能完整覆盖整个CT检查床及扫描孔，无建筑遮挡死角。"
      },
      {
        "dimension": "空间模数与布局",
        "focus": "家属陪护操作面预留",
        "requirement": "综合医院注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
        "source": "《综合医院建设标准》建标110-2021 第五条",
        "suggestion": "考虑到低龄患儿需要家属穿着铅衣在床旁安抚，检查床侧边及尾部必须预留宽度大于或等于1.20m的净操作空间，严禁设备贴墙布置导致家属无处站立。"
      },
      {
        "dimension": "防火分隔与逃生",
        "focus": "防辐射重型门的逃生设计",
        "requirement": "疏散出口门、疏散走道中的门应向疏散方向开启。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.2.1条",
        "suggestion": "CT室的主防护门为电动平移铅门（重达数百公斤）。图纸必须强制要求该电动门配置断电后可手动轻松推拉的机械脱轨装置，或在扫描室另设一扇带闭门器的普通材质外开逃生门（内部加贴相应当量铅板）。"
      },
      {
        "dimension": "防火分隔与逃生",
        "focus": "机房独立防火分隔",
        "requirement": "医院中的手术部、急诊部、重症监护室、贵重精密医疗设备用房等，应采用防火隔墙和不燃楼板与其他部位分隔。",
        "source": "《建筑防火通用规范》GB 55037-2022 第4.3.1条",
        "suggestion": "CT室作为贵重精密医疗设备用房，其机房外围封闭墙体必须同时满足“防辐射”与“耐火极限不低于2.00h”的双重物理属性。"
      },
      {
        "dimension": "防火分隔与逃生",
        "focus": "地沟与孔洞防火封堵",
        "requirement": "建筑内各类管线穿过防火墙、防火隔墙、楼板的孔洞应采用防火封堵材料封堵，封堵的耐火性能不应低于相应分隔构件的耐火性能。",
        "source": "《建筑防火通用规范》GB 55037-2022 第6.3.1条",
        "suggestion": "穿越控制室与扫描室之间隔墙的所有建筑地沟、弱电过线管穿墙孔洞，在管线敷设完毕后，必须使用防火泥或防火膨胀模块进行全密实柔性封堵，彻底杜绝火灾烟气串流。"
      },
      {
        "dimension": "防火分隔与逃生",
        "focus": "零门槛推床顺畅度",
        "requirement": "通向推床的门净宽不应小于1.10m。疏散出口门应为平开门或在火灾时具有平开功能的门，且不应设置门槛。",
        "source": "《综合医院建筑设计标准》第5.1.4条及《建筑防火通用规范》第7.2.1条",
        "suggestion": "主防辐射门开启后的净宽建议大于或等于1.40m。门下地面必须绝对零门槛平接，电动铅门的下部导向轨应采用极浅的地面暗槽，确保病床平稳推入，不引发镇静患儿的惊跳反射。"
      },
      {
        "dimension": "室内装修与防撞",
        "focus": "地材高荷载与抗造防滑",
        "requirement": "医疗用房的地面应平整、防滑、易清洁、耐磨、耐腐蚀、不产尘。地面不应设地垄沟。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.10条",
        "suggestion": "CT设备极重且推床进出频繁，地面必须采用承载力极高、防滑等级R10以上的2.0mm同质透心PVC卷材或橡胶地板。严禁使用极易被推床碾碎的架空防静电地板。"
      },
      {
        "dimension": "室内装修与防撞",
        "focus": "推床极限防撞基座",
        "requirement": "其阴阳角宜做成圆角。有推床或推车通过的门和墙面，应采取防碰撞措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.12条及第39条（三）",
        "suggestion": "室内所有墙角必须执行半径大于或等于20mm的圆角工艺。墙面下部0.20m处必须设置防踢脚，0.90m处满铺高强度抗撞击树脂保护带。"
      },
      {
        "dimension": "物理屏蔽与防护构造",
        "focus": "六面体铅当量屏蔽",
        "requirement": "有防辐射要求的用房，其建筑构造应符合国家现行有关放射防护标准的规定。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.13条",
        "suggestion": "扫描室的四周墙体、楼板及顶板必须形成无死角的六面体屏蔽（通常铅当量要求为2.5mmpb至3.0mmpb）。图纸必须标明硫酸钡砂浆厚度或铅板搭接工艺大样。"
      },
      {
        "dimension": "物理屏蔽与防护构造",
        "focus": "防辐射观察窗底标高",
        "requirement": "有防辐射要求的用房，其建筑构造应符合国家现行有关放射防护标准的规定。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.13条",
        "suggestion": "铅玻璃观察窗的下沿标高应控制在0.80m至0.90m之间，以匹配技师的操作视平线及设备台面高度。铅玻璃四周边框必须与墙体铅板保持至少20mm的物理重叠搭接。"
      },
      {
        "dimension": "物理屏蔽与防护构造",
        "focus": "建筑地沟与射线防漏",
        "requirement": "建筑结构设计应满足医疗设备、悬挂装置等对荷载及安装的要求。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第4.3.2条",
        "suggestion": "扫描室至控制室/设备间必须在楼板上预留线缆地沟（宽约0.3m，深约0.2m）。地沟穿过防辐射墙体处，必须在建筑图纸上绘制“U型或Z型迷宫式防辐射挡板”大样图，严防射线沿地沟直线漏出。"
      }
    ],
    "glbModel": "glb/mt-ct.glb",
    "legacySiteModel": "models/model-real.html?space=ct",
    "docBehaviors": [
      "门诊或急诊平车进入准备位后，完成金属物、造影剂和镇静风险核对，再进入铅防护扫描室。",
      "技师在控制室通过铅玻璃、摄像、双向对讲和PACS/RIS控制台观察检查床全长，完成定位、曝光和报告回传。",
      "增强检查时，高压注射器靠近检查床布置，造影剂管路不跨越家属陪护站位和床尾抢救通道。",
      "设备维护人员经设备/计算机间和服务后场进入，线缆地沟采用折返防护节点，避免直线漏射线。"
    ],
    "modelDetail": {
      "referenceGranularity": "参照儿童手术室模型的“空间壳体+设备细部+隐性系统+动态流线”颗粒度。",
      "roomZones": [
        "扫描室/六面体放射防护",
        "控制室/铅玻璃观察",
        "设备与计算机间",
        "患者准备/平车等候",
        "手卫生与观察恢复"
      ],
      "equipment": [
        "CT机架与内孔",
        "滑移检查床与床轨",
        "定位激光",
        "高压注射器",
        "床旁镇静监护",
        "铅衣架",
        "PACS/RIS控制台",
        "设备机柜",
        "Z型线缆地沟"
      ],
      "animatedFlows": [
        "患者准备→扫描→观察离开",
        "技师控制室→检查室→观察窗",
        "设备维护后场→设备间→主机",
        "主机→控制台→PACS报告",
        "造影剂/医用气体→床旁接口",
        "送风/低位回风/设备排热"
      ],
      "checkPoints": [
        "床侧1.20m陪护净距",
        "观察窗无死角",
        "线缆穿防护墙折返",
        "铅门零门槛",
        "设备排热不进入候诊区"
      ]
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 42,
      "priority": "P0",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 44,
      "finalStatus": "部分完成",
      "finalRequirement": "准备床退出门区；铅门与曝光状态联动；GLB 重导出前以程序化场景为准。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）",
    "glbModelDisabled": true,
    "glbModelDisabledReason": "2026-07-13 GLB 包围核查发现尺度、原点或游离构件异常；程序场景保留，清理并统一米制重导前禁用实景切换。",
    "glbAuditStatus": "隔离待重导"
  },
  {
    "id": "mt_dr",
    "dept": "医技",
    "name": "DR摄片室",
    "type": "imaging",
    "priority": "P0",
    "summary": "DR摄片室以“平床摄影、立位摄影、控制观察、陪护防护”四个操作面组织；3D模型已补入天轨球管、立位胸片架、摄影床、移动铅屏风、铅衣架、平板探测器柜、曝光警示、控制台、患者/技师/防护用品流线和送回风动画。",
    "assets": [],
    "rules": [
      "area",
      "child",
      "infection",
      "clean"
    ],
    "siteModel": "models/viewer.html?scene=mt-dr",
    "siteModelName": "3D交互信息模型（DR摄片室·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "DR摄片室审图重点包括机房面积与双组块布局、立位摄影与强陪护空间、操作视平线与无死角监控等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.1.1条；《综合医院建筑设计标准》GB 51039-2014 第5.1.13条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "机房面积与双组块布局：医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理、洁污路线清楚。",
      "立位摄影与强陪护空间：医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
      "操作视平线与无死角监控：有防辐射要求的用房，其建筑构造应符合国家现行有关放射防护标准的规定。",
      "防辐射重型门的开启逻辑：疏散出口门、疏散走道中的门应向疏散方向开启。",
      "机房独立防火分隔墙：医院中的手术部、急诊部、重症监护室、贵重精密医疗设备用房等，应采用防火隔墙和不燃楼板与其他部位分隔。",
      "穿墙孔洞防火与防辐射双封堵：建筑内各类管线穿过防火墙、防火隔墙、楼板的孔洞应采用防火封堵材料封堵，封堵的耐火性能不应低于相应分隔构件的耐火性能。"
    ],
    "docReview": [
      "空间模数与布局 / 机房面积与双组块布局：DR室单间净使用面积不应小于20.00㎡。室内平面必须同时满足“摄影平床”与“立式胸片架”双组块物理摆放的干涉退让，床头必须脱离墙面放置。",
      "空间模数与布局 / 立位摄影与强陪护空间：为充分应对国内典型的“1+N”多代陪护模式，立式胸片架前方及两侧必须预留极其宽裕的操作空间（半径不小于1.50m），以容纳至少两名家属同时上阵，强行固定抗拒哭闹的患儿体位。",
      "空间模数与布局 / 操作视平线与无死角监控：控制室与扫描室之间必须设置防辐射铅玻璃观察窗。窗台下沿标高控制在0.80m至0.90m。技师视线必须同时无死角覆盖摄影平床与立式胸片架。",
      "防火分隔与逃生 / 防辐射重型门的开启逻辑：DR室电动防辐射平移门必须向室外疏散方向滑动，且必须具备断电后人力可手动推拉的机械脱轨功能。开启净宽建议大于或等于1.20m，保障担架车顺畅逃生。",
      "防火分隔与逃生 / 机房独立防火分隔墙：DR室作为精密医疗设备用房，其四周实体墙必须同时满足“防辐射”与“耐火极限不低于2.00h”的双重物理属性，砌筑至结构楼板底。",
      "防火分隔与逃生 / 穿墙孔洞防火与防辐射双封堵：连接控制室与扫描室的弱电穿墙孔洞、观察窗窗框缝隙，必须使用含有重晶石成分的防火防辐射泥进行全密实封堵，确保火灾烟气与散射射线双重阻断。",
      "防火分隔与逃生 / 地平零门槛与轨道暗埋：主防辐射门下方地面必须绝对零门槛平接处理。重型铅门的底部导向轨应采用极浅的无缝暗槽，确保病床平稳推入。",
      "室内装修与防撞 / 地材高承载与防划痕：DR室面临极高频的轮椅与平推车进出，地面必须采用耐磨等级T级以上的同质透心PVC卷材或橡胶地板。所有材料接缝必须进行热熔焊接。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与布局",
        "focus": "机房面积与双组块布局",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理、洁污路线清楚。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "DR室单间净使用面积不应小于20.00㎡。室内平面必须同时满足“摄影平床”与“立式胸片架”双组块物理摆放的干涉退让，床头必须脱离墙面放置。"
      },
      {
        "dimension": "空间模数与布局",
        "focus": "立位摄影与强陪护空间",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "为充分应对国内典型的“1+N”多代陪护模式，立式胸片架前方及两侧必须预留极其宽裕的操作空间（半径不小于1.50m），以容纳至少两名家属同时上阵，强行固定抗拒哭闹的患儿体位。"
      },
      {
        "dimension": "空间模数与布局",
        "focus": "操作视平线与无死角监控",
        "requirement": "有防辐射要求的用房，其建筑构造应符合国家现行有关放射防护标准的规定。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.13条",
        "suggestion": "控制室与扫描室之间必须设置防辐射铅玻璃观察窗。窗台下沿标高控制在0.80m至0.90m。技师视线必须同时无死角覆盖摄影平床与立式胸片架。"
      },
      {
        "dimension": "防火分隔与逃生",
        "focus": "防辐射重型门的开启逻辑",
        "requirement": "疏散出口门、疏散走道中的门应向疏散方向开启。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.2.1条",
        "suggestion": "DR室电动防辐射平移门必须向室外疏散方向滑动，且必须具备断电后人力可手动推拉的机械脱轨功能。开启净宽建议大于或等于1.20m，保障担架车顺畅逃生。"
      },
      {
        "dimension": "防火分隔与逃生",
        "focus": "机房独立防火分隔墙",
        "requirement": "医院中的手术部、急诊部、重症监护室、贵重精密医疗设备用房等，应采用防火隔墙和不燃楼板与其他部位分隔。",
        "source": "《建筑防火通用规范》GB 55037-2022 第4.3.1条",
        "suggestion": "DR室作为精密医疗设备用房，其四周实体墙必须同时满足“防辐射”与“耐火极限不低于2.00h”的双重物理属性，砌筑至结构楼板底。"
      },
      {
        "dimension": "防火分隔与逃生",
        "focus": "穿墙孔洞防火与防辐射双封堵",
        "requirement": "建筑内各类管线穿过防火墙、防火隔墙、楼板的孔洞应采用防火封堵材料封堵，封堵的耐火性能不应低于相应分隔构件的耐火性能。",
        "source": "《建筑防火通用规范》GB 55037-2022 第6.3.1条",
        "suggestion": "连接控制室与扫描室的弱电穿墙孔洞、观察窗窗框缝隙，必须使用含有重晶石成分的防火防辐射泥进行全密实封堵，确保火灾烟气与散射射线双重阻断。"
      },
      {
        "dimension": "防火分隔与逃生",
        "focus": "地平零门槛与轨道暗埋",
        "requirement": "通向推床的门净宽不应小于1.10m。疏散出口门应为平开门或在火灾时具有平开功能的门，且不应设置门槛。",
        "source": "《综合医院建筑设计标准》第5.1.4条及《建筑防火通用规范》第7.2.1条",
        "suggestion": "主防辐射门下方地面必须绝对零门槛平接处理。重型铅门的底部导向轨应采用极浅的无缝暗槽，确保病床平稳推入。"
      },
      {
        "dimension": "室内装修与防撞",
        "focus": "地材高承载与防划痕",
        "requirement": "医疗用房的地面应平整、防滑、易清洁、耐磨、耐腐蚀、不产尘。地面不应设地垄沟。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.10条",
        "suggestion": "DR室面临极高频的轮椅与平推车进出，地面必须采用耐磨等级T级以上的同质透心PVC卷材或橡胶地板。所有材料接缝必须进行热熔焊接。"
      },
      {
        "dimension": "室内装修与防撞",
        "focus": "阴阳角与极限推车防撞",
        "requirement": "其阴阳角宜做成圆角。有推床或推车通过的门和墙面，应采取防碰撞措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.12条及第39条（三）",
        "suggestion": "室内所有墙角必须执行半径大于或等于20mm的圆角工艺。摄影床四周墙面的下部0.20m处必须设置防踢脚，0.90m处满铺高强度抗撞击树脂保护带。"
      },
      {
        "dimension": "物理屏蔽与防护构造",
        "focus": "六面体铅当量绝对封闭",
        "requirement": "有防辐射要求的用房，其建筑构造应符合国家现行有关放射防护标准的规定。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.13条",
        "suggestion": "扫描室的四周墙体、楼板及顶板必须形成无缝隙的六面体电离辐射屏蔽（通常铅当量要求为2.0mmpb至2.5mmpb）。图纸必须标明硫酸钡砂浆厚度或铅板搭接工艺。"
      },
      {
        "dimension": "物理屏蔽与防护构造",
        "focus": "迷宫式门斗与折射屏蔽",
        "requirement": "有防辐射要求的用房，其建筑构造应符合国家现行有关放射防护标准的规定。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.13条",
        "suggestion": "针对DR机房外公共走廊的高频人流，机房大门处宜在建筑平面上设计“L型迷宫式短走道（缓冲门斗）”，利用物理墙体的多次折射，将逃逸至公共候诊区的散射射线降至最低。"
      }
    ],
    "legacySiteModel": "models/model-real.html?space=ct",
    "docBehaviors": [
      "患儿可按步入、轮椅或平车进入，分别完成立位胸片、摄影平床或床旁固定。",
      "家属穿铅衣后在移动铅屏风后协助固定体位，不应站到主射线方向或阻断技师通道。",
      "技师通过铅玻璃观察窗同时观察立位架和平床，曝光控制与语音提示在控制侧完成。",
      "探测器、固定带和铅衣集中在检查区边缘，避免散放造成儿童绊倒和推床碰撞。"
    ],
    "modelDetail": {
      "referenceGranularity": "参照儿童手术室模型对器械台、吊塔和人员位置的细分，DR拆成平床、立位、天轨、陪护防护四个操作组块。",
      "roomZones": [
        "DR摄片室/铅防护",
        "控制室/铅玻璃观察",
        "患者准备/平车等候",
        "手卫生/观察恢复",
        "设备/计算机间"
      ],
      "equipment": [
        "摄影平床",
        "立位胸片架",
        "天轨球管",
        "限束器与定位光",
        "移动铅屏风",
        "铅衣架",
        "平板探测器柜",
        "PACS控制台"
      ],
      "animatedFlows": [
        "步入/轮椅/平车患者定位",
        "技师控制观察",
        "防护用品取用",
        "影像数据回传",
        "送风/设备排热"
      ],
      "checkPoints": [
        "双组块净距",
        "陪护防护站位",
        "铅玻璃视线",
        "铅门迷宫入口",
        "探测器收纳"
      ]
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 43,
      "priority": "P0",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 45,
      "finalStatus": "已完成",
      "finalRequirement": "保留长凳/更衣室合理接触以及铅门曝光状态。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "mt_imaging_center",
    "dept": "医技",
    "name": "放射影像中心",
    "type": "imaging",
    "priority": "P1",
    "summary": "放射影像中心按“门诊候诊、二次候诊/更衣、平车镇静复苏、CT/MRI/DR/骨密度组团、集中控制报告、设备服务脊线、洁污支持”组织；3D模型已补入各机房设备附件、PACS四屏报告台、剂量/磁安全总览、复苏医气、影像数据流、镇静支持流、防护用品流和多组气流动画。",
    "assets": [],
    "rules": [
      "area",
      "privacy",
      "child",
      "infection"
    ],
    "siteModel": "models/viewer.html?scene=mt-imaging-center",
    "siteModelName": "3D交互信息模型（放射影像中心·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "放射影像中心审图重点包括医患双通道物理隔离、门诊与住院患儿分流、镇静与复苏空间前置预留等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.4.1条；《综合医院建筑设计标准》GB 51039-2014 第5.1.1条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "医患双通道物理隔离：放射科、核医学科、超声科等医技科室，应设医护人员专用通道。",
      "门诊与住院患儿分流：医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
      "镇静与复苏空间前置预留：综合医院注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
      "未苏醒患儿的单向转运：医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
      "候诊区大纵深与推车槽：候诊处应设面积不小于1.5㎡/人的等候区。儿科候诊区面积应按不小于2㎡/人设计。",
      "二次候诊与隐私更衣：医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。"
    ],
    "docReview": [
      "动线与分流 / 医患双通道物理隔离：部门平面必须规划“双走廊”结构。外侧为患儿与家属公共候诊走廊，内侧为医护专用的操作与办公走廊，通过控制室实现视觉联系与流线绝对阻断。",
      "动线与分流 / 门诊与住院患儿分流：平面布局应尽量设置“门急诊专用影像区”与“住院部专用影像区”。若共用设备，则必须在平面端头规划住院推床专用等候区，严防穿着病号服的患儿与门诊流感患儿交叉聚集。",
      "镇静工艺流线闭环 / 镇静与复苏空间前置预留：平面必须构建“镇静评估诱导区 → MRI/CT机房 → 检后苏醒复苏区”的空间闭环，面积配比建议按单台MRI配置不少于2张镇静/复苏床位。",
      "镇静工艺流线闭环 / 未苏醒患儿的单向转运：审查图纸的“推床动线”。复苏区必须紧邻机房出口，严禁刚做完检查、尚未完全苏醒的患儿被平推车推入嘈杂的门诊公共走廊中穿行转运。",
      "候诊阵列与公共空间 / 候诊区大纵深与推车槽：考虑到影像检查耗时长，候诊大厅通道净宽必须大于或等于3.00m。两侧墙面必须规划深度大于1.00m的“推床等候槽”及“婴儿车集中停放带”，防止阻塞生命通道。",
      "候诊阵列与公共空间 / 二次候诊与隐私更衣：大机房外部必须设置带有推拉门的“二次候诊/更衣隔间”。患儿在此脱去带有金属拉链的衣物换上检查服，避免在公共走廊当众更衣，保护大龄儿童隐私。",
      "防火分隔与应急疏散 / 重型铅门的逃生障碍：（机房的电动防辐射铅门极其沉重，一旦火灾断电，家属推床根本无法手动拉开。审查时必须要求大型机房另设一扇带闭门器的普通材质外开逃生门（需加贴铅板），或电动铅门必须具备断电物理机械推开功能。",
      "防火分隔与应急疏散 / 影像大平层的防火分区：放射影像中心内集中了全院最昂贵的设备，其整个部门的外围边界必须采用耐火极限不低于2.00h的防火隔墙与其他门诊区域实施绝对物理分隔。"
    ],
    "docReviewRows": [
      {
        "dimension": "动线与分流",
        "focus": "医患双通道物理隔离",
        "requirement": "放射科、核医学科、超声科等医技科室，应设医护人员专用通道。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.4.1条",
        "suggestion": "部门平面必须规划“双走廊”结构。外侧为患儿与家属公共候诊走廊，内侧为医护专用的操作与办公走廊，通过控制室实现视觉联系与流线绝对阻断。"
      },
      {
        "dimension": "动线与分流",
        "focus": "门诊与住院患儿分流",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "平面布局应尽量设置“门急诊专用影像区”与“住院部专用影像区”。若共用设备，则必须在平面端头规划住院推床专用等候区，严防穿着病号服的患儿与门诊流感患儿交叉聚集。"
      },
      {
        "dimension": "镇静工艺流线闭环",
        "focus": "镇静与复苏空间前置预留",
        "requirement": "综合医院注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
        "source": "《综合医院建设标准》建标110-2021 第五条（引申至儿童特殊需求）",
        "suggestion": "平面必须构建“镇静评估诱导区 → MRI/CT机房 → 检后苏醒复苏区”的空间闭环，面积配比建议按单台MRI配置不少于2张镇静/复苏床位。"
      },
      {
        "dimension": "镇静工艺流线闭环",
        "focus": "未苏醒患儿的单向转运",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "审查图纸的“推床动线”。复苏区必须紧邻机房出口，严禁刚做完检查、尚未完全苏醒的患儿被平推车推入嘈杂的门诊公共走廊中穿行转运。"
      },
      {
        "dimension": "候诊阵列与公共空间",
        "focus": "候诊区大纵深与推车槽",
        "requirement": "候诊处应设面积不小于1.5㎡/人的等候区。儿科候诊区面积应按不小于2㎡/人设计。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.4.1条及第5.2.6条",
        "suggestion": "考虑到影像检查耗时长，候诊大厅通道净宽必须大于或等于3.00m。两侧墙面必须规划深度大于1.00m的“推床等候槽”及“婴儿车集中停放带”，防止阻塞生命通道。"
      },
      {
        "dimension": "候诊阵列与公共空间",
        "focus": "二次候诊与隐私更衣",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "大机房外部必须设置带有推拉门的“二次候诊/更衣隔间”。患儿在此脱去带有金属拉链的衣物换上检查服，避免在公共走廊当众更衣，保护大龄儿童隐私。"
      },
      {
        "dimension": "防火分隔与应急疏散",
        "focus": "重型铅门的逃生障碍",
        "requirement": "疏散出口门、疏散走道中的门应向疏散方向开启。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.2.1条",
        "suggestion": "（机房的电动防辐射铅门极其沉重，一旦火灾断电，家属推床根本无法手动拉开。审查时必须要求大型机房另设一扇带闭门器的普通材质外开逃生门（需加贴铅板），或电动铅门必须具备断电物理机械推开功能。"
      },
      {
        "dimension": "防火分隔与应急疏散",
        "focus": "影像大平层的防火分区",
        "requirement": "医院中的手术部、急诊部、重症监护室、贵重精密医疗设备用房等，应采用防火隔墙和不燃楼板与其他部位分隔。",
        "source": "《建筑防火通用规范》GB 55037-2022 第4.3.1条",
        "suggestion": "放射影像中心内集中了全院最昂贵的设备，其整个部门的外围边界必须采用耐火极限不低于2.00h的防火隔墙与其他门诊区域实施绝对物理分隔。"
      },
      {
        "dimension": "防火分隔与应急疏散",
        "focus": "长走廊的推床疏散净宽",
        "requirement": "疏散走道、疏散出口的净宽度应满足人员安全疏散的要求。走道净宽不应小于2.40m。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.4条及GB 51039第5.1.2条",
        "suggestion": "影像科内部存在大量推床转运。其核心主走廊在剔除候诊座椅、自助取片机等突出物后，实际可通行的物理净宽必须实打实地大于或等于2.40m（建议3.00m），保障两辆平车能全速错车。"
      },
      {
        "dimension": "结构预留与防辐射边界",
        "focus": "集中防护与机房组团",
        "requirement": "有防辐射要求的用房，其建筑构造应符合国家现行有关放射防护标准的规定。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.13条",
        "suggestion": "产生电离辐射的机房（DR、CT等）在平面排布上必须“集中组团”放置，减少防辐射墙体的总延米数。无电离辐射（超声、MRI等）可灵活布置。"
      },
      {
        "dimension": "结构预留与防辐射边界",
        "focus": "大型设备结构荷载下传",
        "requirement": "建筑结构设计应满足医疗设备、悬挂装置等对荷载及安装的要求。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第4.3.2条",
        "suggestion": "必须强制对比“建筑平面图”与“结构配筋图”。MRI、大型CT、双能X线骨密度仪等机房的底板承重标示必须大于或等于8~10kN/㎡，且下方不宜布置水泵房等震动源。"
      },
      {
        "dimension": "结构预留与防辐射边界",
        "focus": "防辐射隔墙砌筑边界",
        "requirement": "有防辐射要求的用房，其建筑构造应符合国家现行有关放射防护标准的规定。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.13条",
        "suggestion": "在建筑剖面图审查中，带有辐射防护要求的硫酸钡砂浆墙面或铅板夹芯墙，必须标明“砌筑至建筑结构真顶（楼板底）”，严禁在吊顶层上方遗留辐射散溢孔洞。"
      }
    ],
    "legacySiteModel": "models/model-real.html?space=ct",
    "docBehaviors": [
      "门诊患儿从登记候诊进入二次候诊/更衣，再按检查类型进入DR、骨密度或CT。",
      "急诊/住院平车从后场入口进入平车候诊与镇静复苏区，优先对接CT/MRI，检查后不穿越公共候诊大厅。",
      "技师在集中控制/报告后台通过观察窗和PACS工作站管理各机房，医患动线通过控制边界分开。",
      "设备维护从服务脊线进入CT/MRI设备区，PACS服务器和设备散热集中在后台，减少对候诊区的噪声与热量干扰。",
      "复苏床旁氧气/吸引、CT增强注射、MRI线圈、DR铅衣屏风等专科附件按机房组团就近布置。"
    ],
    "modelDetail": {
      "referenceGranularity": "参照儿童手术室模型对洁净流、污物流、医用气体和层流气流的表达，把影像中心转译为患者/平车/技师/维护/数据/医气/气流的多系统模型。",
      "roomZones": [
        "门诊登记/候诊",
        "二次候诊/更衣",
        "平车候诊/镇静复苏",
        "CT套间",
        "MRI Zone 3-4",
        "DR摄片套间",
        "骨密度/低剂量",
        "集中控制/报告后台",
        "设备服务脊线",
        "洁净/污物支持"
      ],
      "equipment": [
        "CT扫描机与增强注射车",
        "MRI磁体/线圈柜/铁磁筛查",
        "DR平床/立位/移动铅屏风/铅衣架",
        "骨密度床/隐私屏风",
        "四屏PACS报告台",
        "PACS服务器柜",
        "复苏床/监护/医气面板",
        "剂量与磁安全总览板"
      ],
      "animatedFlows": [
        "门诊患者流",
        "急诊/住院平车流",
        "技师流",
        "设备维护流",
        "影像数据流",
        "医用气体/镇静支持流",
        "防护用品流",
        "候诊送风",
        "机房排热",
        "MRI失超排放",
        "复苏/污物排风"
      ],
      "checkPoints": [
        "医患双通道",
        "平车不穿越候诊",
        "复苏紧邻CT/MRI",
        "电离辐射机房集中组团",
        "MRI磁安全独立边界",
        "PACS/设备散热后台化"
      ]
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 30,
      "priority": "P1",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 32,
      "finalStatus": "部分完成",
      "finalRequirement": "明确关系模型；用于审图时改为真实房间；候诊退出入口。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）",
    "sceneInfo": {
      "modelScope": "关系模型",
      "measurementNotice": "仅表达科室分区、邻接与流程关系，不可用于房间净距或设备安装量测。"
    }
  },
  {
    "id": "mt_imaging_waiting",
    "dept": "医技",
    "name": "影像候诊区",
    "type": "imaging",
    "priority": "P3",
    "summary": "影像候诊区按“普通候诊、二次候诊/更衣、平车/婴儿车泊位、无磁准备与隐私保护”组织；3D模型表达候诊座席、二次候诊、更衣柜、平车泊位、患者流、平车流和送排风。",
    "assets": [],
    "rules": [
      "area",
      "privacy",
      "child",
      "gas"
    ],
    "siteModel": "models/viewer.html?scene=mt-imaging-waiting",
    "siteModelName": "3D交互信息模型（影像候诊区·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "影像候诊区审图重点包括候诊面积极限压力测试、婴儿车专属收纳内凹带、二次候诊与分流缓冲区等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.4.1条及第5.2.6条；《综合医院建筑设计标准》GB 51039-2014 第5.1.1条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "候诊面积极限压力测试：候诊处应设面积不小于1.5㎡/人的等候区。儿科候诊区面积应按不小于2㎡/人设计。",
      "婴儿车专属收纳内凹带：医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
      "二次候诊与分流缓冲区：医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
      "聚集极峰期的疏散走道净宽：疏散走道、疏散出口的净宽度应满足人员安全疏散的要求。走道净宽不应小于2.40m。",
      "装修材料高阻燃标准：医疗建筑内部装修材料的燃烧性能等级不应低于A级，部分部位不应低于B1级。",
      "无磁更衣与隐私保护：检查、治疗用房应满足使用人群的隐私要求。"
    ],
    "docReview": [
      "空间模数与阵列 / 候诊面积极限压力测试：影像检查耗时极长，必须按照“极值人流”测算。建议单人面积指标放大至2.50㎡至3.00㎡/人，座位排间距必须大于或等于1.50m，以容纳双家长换手抱持及走动安抚。",
      "空间模数与阵列 / 婴儿车专属收纳内凹带：平面图纸必须在主排队与通行动线外侧的非承重墙面上，硬性划定一块深度大于或等于1.20m的“婴儿车与营地车集中停放槽”，严禁海量推车在主走廊“列道停放”。",
      "空间模数与阵列 / 二次候诊与分流缓冲区：必须在大型机房（CT/MRI）门外建立深约2.00m的“二次候诊”。通过物理半隔断将即将检查的患儿与大厅内喧闹的患儿分流，降低临检前的交叉恐慌。",
      "防火分隔与逃生 / 聚集极峰期的疏散走道净宽：在剔除等候座椅、自助取片机柜、饮水机等所有突出物后，影像大厅的主疏散走道物理净宽必须实打实地大于或等于3.00m，保障大量推车人群的瞬间疏散。",
      "防火分隔与逃生 / 装修材料高阻燃标准：候诊大厅面积大且人员极度密集，吊顶及顶棚必须采用A级不燃材料。墙面适儿化软包及卡通树脂板必须由厂家出具B1级以上的阻燃检测合格报告。",
      "专科工艺与隐私 / 无磁更衣与隐私保护：MRI检查严禁穿戴金属。候诊区必须嵌入设置带有推拉门或厚重隔帘的“独立更衣隔间”。隔间内部必须提供宽大折叠台（供婴儿平躺换衣）及绝对无磁的纯塑胶挂钩。",
      "专科工艺与隐私 / 内置母婴与特殊生理准备：候诊区必须就近配置母婴室（用于空腹检查后的紧急哺乳及换尿布）。此外，超声候诊区需就近设置具备高低双级饮水台的“憋尿饮水区”及儿童专属卫生间。",
      "室内装修与防护 / 大跨度防混响声学顶棚：影像候诊区内“饿哭、怕哭、镇静失败哭”多点爆发。大厅吊顶必须满铺降噪系数大于或等于0.8的微孔吸音金属板，墙体1.20m以上部位宜采用吸音板结构，强行压制声波反射。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与阵列",
        "focus": "候诊面积极限压力测试",
        "requirement": "候诊处应设面积不小于1.5㎡/人的等候区。儿科候诊区面积应按不小于2㎡/人设计。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.4.1条及第5.2.6条",
        "suggestion": "影像检查耗时极长，必须按照“极值人流”测算。建议单人面积指标放大至2.50㎡至3.00㎡/人，座位排间距必须大于或等于1.50m，以容纳双家长换手抱持及走动安抚。"
      },
      {
        "dimension": "空间模数与阵列",
        "focus": "婴儿车专属收纳内凹带",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "平面图纸必须在主排队与通行动线外侧的非承重墙面上，硬性划定一块深度大于或等于1.20m的“婴儿车与营地车集中停放槽”，严禁海量推车在主走廊“列道停放”。"
      },
      {
        "dimension": "空间模数与阵列",
        "focus": "二次候诊与分流缓冲区",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "必须在大型机房（CT/MRI）门外建立深约2.00m的“二次候诊”。通过物理半隔断将即将检查的患儿与大厅内喧闹的患儿分流，降低临检前的交叉恐慌。"
      },
      {
        "dimension": "防火分隔与逃生",
        "focus": "聚集极峰期的疏散走道净宽",
        "requirement": "疏散走道、疏散出口的净宽度应满足人员安全疏散的要求。走道净宽不应小于2.40m。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.4条及GB 51039第5.1.2条",
        "suggestion": "在剔除等候座椅、自助取片机柜、饮水机等所有突出物后，影像大厅的主疏散走道物理净宽必须实打实地大于或等于3.00m，保障大量推车人群的瞬间疏散。"
      },
      {
        "dimension": "防火分隔与逃生",
        "focus": "装修材料高阻燃标准",
        "requirement": "医疗建筑内部装修材料的燃烧性能等级不应低于A级，部分部位不应低于B1级。",
        "source": "《建筑防火通用规范》GB 55037-2022 第6.1.1条",
        "suggestion": "候诊大厅面积大且人员极度密集，吊顶及顶棚必须采用A级不燃材料。墙面适儿化软包及卡通树脂板必须由厂家出具B1级以上的阻燃检测合格报告。"
      },
      {
        "dimension": "专科工艺与隐私",
        "focus": "无磁更衣与隐私保护",
        "requirement": "检查、治疗用房应满足使用人群的隐私要求。",
        "source": "《综合医院建设标准》建标110-2021 第三十九条（八）",
        "suggestion": "MRI检查严禁穿戴金属。候诊区必须嵌入设置带有推拉门或厚重隔帘的“独立更衣隔间”。隔间内部必须提供宽大折叠台（供婴儿平躺换衣）及绝对无磁的纯塑胶挂钩。"
      },
      {
        "dimension": "专科工艺与隐私",
        "focus": "内置母婴与特殊生理准备",
        "requirement": "儿科等区域卫生间应设置儿童卫生间或儿童专用洁具。",
        "source": "《综合医院建设标准》建标110-2021 第三十九条（六）",
        "suggestion": "候诊区必须就近配置母婴室（用于空腹检查后的紧急哺乳及换尿布）。此外，超声候诊区需就近设置具备高低双级饮水台的“憋尿饮水区”及儿童专属卫生间。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "大跨度防混响声学顶棚",
        "requirement": "综合医院注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
        "source": "《综合医院建设标准》建标110-2021 第五条",
        "suggestion": "影像候诊区内“饿哭、怕哭、镇静失败哭”多点爆发。大厅吊顶必须满铺降噪系数大于或等于0.8的微孔吸音金属板，墙体1.20m以上部位宜采用吸音板结构，强行压制声波反射。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "阴阳角防撞与立面保护",
        "requirement": "其阴阳角宜做成圆角。有推床或推车通过的门和墙面，应采取防碰撞措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.12条及第39条（三）",
        "suggestion": "室内所有墙角、柱角必须执行半径大于或等于30mm的圆角工艺。沿走道侧墙面0.20m与0.90m处必须满铺防踢脚及高强度抗撞击树脂保护带。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "防跌落与防触电安全屏障",
        "requirement": "儿童诊疗区域的门窗、家具和楼地面等应采取必要的安全保护措施。",
        "source": "《综合医院建设标准》建标110-2021 第三十九条（七）",
        "suggestion": "候诊外窗必须安装带钥匙的物理限位器，开启扇缝隙宽度锁死在10cm以内。大厅内所有强电插座必须加装带锁的安全防护盖，严防幼儿在长时间等候中无聊乱抠。"
      },
      {
        "dimension": "视觉干预与安抚",
        "focus": "多媒体视线工程学预留",
        "requirement": "综合医院注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
        "source": "《综合医院建设标准》建标110-2021 第五条",
        "suggestion": "建筑墙面必须预留电视屏幕或交互式投影挂点。屏幕中心标高应控制在1.00m至1.20m之间，匹配坐姿患儿平视视线。候诊区墙面宜大面积使用明快但低饱和度的插画级树脂抗倍特板。"
      },
      {
        "dimension": "视觉干预与安抚",
        "focus": "昼夜节律与防眩光照明",
        "requirement": "医疗用房应采用高显色照明光源，显色指数应大于或等于80。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第8.6.2条",
        "suggestion": "候诊大厅应具备良好的自然采光。人工照明严禁设置裸露的直射光源，必须采用漫反射防眩光灯盘，且具备分级调光功能，为服用镇静药剂后在母亲怀中入睡的患儿提供昏暗环境。"
      }
    ],
    "legacySiteModel": "models/model-real.html?space=ct",
    "docBehaviors": [
      "普通候诊承接登记后患者，二次候诊只容纳即将检查的患儿，减少临检前恐惧扩散。",
      "MRI相关候诊应预留无磁更衣与金属物品暂存，隐私更衣不应占用主通道。",
      "平车、婴儿车和营地车应进入专属泊位，避免把公共通道变成临时停车场。"
    ],
    "modelDetail": {
      "referenceGranularity": "参照儿童手术室模型对患者/洁污流线的表达，把候诊区作为影像科前置工艺节点，而非家具布置图。",
      "roomZones": [
        "普通候诊",
        "二次候诊/更衣",
        "平车/婴儿车泊位",
        "去机房缓冲口"
      ],
      "equipment": [
        "候诊连排椅",
        "更衣/准备隔间",
        "平车/婴儿车泊位",
        "手卫生/提示节点"
      ],
      "animatedFlows": [
        "登记→候诊→二次候诊→检查室",
        "急诊/住院平车→平车候诊→检查",
        "候诊送风",
        "污物/卫生点排风"
      ],
      "checkPoints": [
        "候诊面积",
        "二次候诊深度",
        "隐私更衣",
        "推车泊位",
        "主通道净宽"
      ]
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 41,
      "priority": "P3",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 43,
      "finalStatus": "部分完成",
      "finalRequirement": "补轮椅、陪护与镇静人员；更衣室可闭合；人物绑定候诊位。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "mt_lab",
    "dept": "医技",
    "name": "PCR实验室",
    "type": "lab",
    "priority": "P0",
    "summary": "PCR实验室审图重点包括核心四区（或三区）物理硬隔离、独立缓冲间的纵深与模数、人流的“绝对单向不折返”等内容；依据《实验室生物安全通用要求》GB 19489-2008及卫办医政发〔2010〕194号《导则》；《实验室生物安全通用要求》GB 19489-2008第6.3.3条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/医技/检验-prc.dwg"
    ],
    "rules": [
      "area",
      "handwash",
      "privacy",
      "infection"
    ],
    "siteModel": "models/viewer.html?scene=mt-lab",
    "siteModelName": "3D交互信息模型（PCR实验室·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "PCR实验室审图重点包括核心四区（或三区）物理硬隔离、独立缓冲间的纵深与模数、人流的“绝对单向不折返”等内容；依据《实验室生物安全通用要求》GB 19489-2008及卫办医政发〔2010〕194号《导则》；《实验室生物安全通用要求》GB 19489-2008第6.3.3条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "核心四区（或三区）物理硬隔离：实验室各区应相互独立。",
      "独立缓冲间的纵深与模数：进入实验室应通过缓冲间。缓冲间内应能容纳更衣等设备。",
      "人流的“绝对单向不折返”：医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理、洁污路线清楚。",
      "物流传递窗的建筑互锁：实验室各区之间的传递应通过传递窗。",
      "高危实验室独立防火分区：医院中的手术部、急诊部、重症监护室、贵重精密医疗设备用房等，应采用防火隔墙和不燃楼板与其他部位分隔。",
      "迷宫嵌套空间的疏散距离：建筑内安全出口、疏散门和疏散走道的布置，应满足人员安全疏散的要求。"
    ],
    "docReview": [
      "空间模数与微观分区 / 核心四区（或三区）物理硬隔离：必须在建筑图上审查是否具备刚性实体隔墙划分的四区：试剂准备区、标本制备区、扩增区、产物分析区（若采用全自动实时荧光PCR可合为三区）。严禁采用轻质矮隔断，各区必须完全独立。",
      "空间模数与微观分区 / 独立缓冲间的纵深与模数：核心工作区与外部走廊之间必须设置缓冲间。缓冲间单间净面积不应小于3.00㎡，深度不应小于1.50m，确保两道门不会同时被打开，且能容纳洗手池、脱衣桶及隔离衣挂钩。",
      "单向流线控制 / 人流的“绝对单向不折返”：图纸必须画出明确的单向人流：试剂区→标本区→扩增区→分析区。人员离开高污染区（如标本区）必须通过缓冲间脱去防护服直接进入公共走廊，绝对严禁逆向返回上游洁净区。",
      "单向流线控制 / 物流传递窗的建筑互锁：各区共用墙体上必须设置传递窗。审查要求：1.必须是机械或电子互锁传递窗（一门开，另一门锁死）；2.严禁传递窗装在门上；3.传递方向必须且只能是顺向（试剂→标本→扩增），杜绝逆流。",
      "防火分隔与应急逃生 / 高危实验室独立防火分区：PCR实验室作为高等级生物安全区域，其外围墙体必须为耐火极限不低于2.00h的实体防火隔墙，将其与普通门诊、办公区实施绝对的防火及防污染物理分隔。",
      "防火分隔与应急逃生 / 迷宫嵌套空间的疏散距离：PCR由于缓冲间层层嵌套，极易形成迷宫。在防火审查时，必须测量“最深处（如扩增区）内任意一点，穿过缓冲间到达外部公共安全走廊的实际步行距离”，必须严格控制在规范允许的短距离直跑范围内。",
      "防火分隔与应急逃生 / 全封闭空间的防爆排烟通道：既然建筑外窗被强制要求“不可开启”以保证感控密闭，那么在三级工艺图纸中，就必须预留专门的独立建筑竖井或墙体通道，专供消防排烟及事故通风排风管使用。",
      "气密物理与感控边界 / 六面体无缝隙防渗漏：整个PCR实验室（含缓冲间）必须形成“全封闭密闭舱”。吊顶必须为全密闭硬质彩钢板或抗菌树脂板（打硅酮结构胶），绝对严禁使用留有缝隙的矿棉板或铝扣板。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与微观分区",
        "focus": "核心四区（或三区）物理硬隔离",
        "requirement": "实验室各区应相互独立。",
        "source": "《实验室生物安全通用要求》GB 19489-2008及卫办医政发〔2010〕194号《导则》",
        "suggestion": "必须在建筑图上审查是否具备刚性实体隔墙划分的四区：试剂准备区、标本制备区、扩增区、产物分析区（若采用全自动实时荧光PCR可合为三区）。严禁采用轻质矮隔断，各区必须完全独立。"
      },
      {
        "dimension": "空间模数与微观分区",
        "focus": "独立缓冲间的纵深与模数",
        "requirement": "进入实验室应通过缓冲间。缓冲间内应能容纳更衣等设备。",
        "source": "《实验室生物安全通用要求》GB 19489-2008第6.3.3条",
        "suggestion": "核心工作区与外部走廊之间必须设置缓冲间。缓冲间单间净面积不应小于3.00㎡，深度不应小于1.50m，确保两道门不会同时被打开，且能容纳洗手池、脱衣桶及隔离衣挂钩。"
      },
      {
        "dimension": "单向流线控制",
        "focus": "人流的“绝对单向不折返”",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理、洁污路线清楚。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.1条",
        "suggestion": "图纸必须画出明确的单向人流：试剂区→标本区→扩增区→分析区。人员离开高污染区（如标本区）必须通过缓冲间脱去防护服直接进入公共走廊，绝对严禁逆向返回上游洁净区。"
      },
      {
        "dimension": "单向流线控制",
        "focus": "物流传递窗的建筑互锁",
        "requirement": "实验室各区之间的传递应通过传递窗。",
        "source": "《医疗机构临床基因扩增检验实验室工作导则》",
        "suggestion": "各区共用墙体上必须设置传递窗。审查要求：1.必须是机械或电子互锁传递窗（一门开，另一门锁死）；2.严禁传递窗装在门上；3.传递方向必须且只能是顺向（试剂→标本→扩增），杜绝逆流。"
      },
      {
        "dimension": "防火分隔与应急逃生",
        "focus": "高危实验室独立防火分区",
        "requirement": "医院中的手术部、急诊部、重症监护室、贵重精密医疗设备用房等，应采用防火隔墙和不燃楼板与其他部位分隔。",
        "source": "《建筑防火通用规范》GB 55037-2022第4.3.1条",
        "suggestion": "PCR实验室作为高等级生物安全区域，其外围墙体必须为耐火极限不低于2.00h的实体防火隔墙，将其与普通门诊、办公区实施绝对的防火及防污染物理分隔。"
      },
      {
        "dimension": "防火分隔与应急逃生",
        "focus": "迷宫嵌套空间的疏散距离",
        "requirement": "建筑内安全出口、疏散门和疏散走道的布置，应满足人员安全疏散的要求。",
        "source": "《建筑防火通用规范》GB 55037-2022第7.1.1条",
        "suggestion": "PCR由于缓冲间层层嵌套，极易形成迷宫。在防火审查时，必须测量“最深处（如扩增区）内任意一点，穿过缓冲间到达外部公共安全走廊的实际步行距离”，必须严格控制在规范允许的短距离直跑范围内。"
      },
      {
        "dimension": "防火分隔与应急逃生",
        "focus": "全封闭空间的防爆排烟通道",
        "requirement": "建筑内部装修不应擅自减少、改动、拆除、遮挡消防设施。",
        "source": "《建筑防火通用规范》GB 55037-2022第6.5.1条（引申）",
        "suggestion": "既然建筑外窗被强制要求“不可开启”以保证感控密闭，那么在三级工艺图纸中，就必须预留专门的独立建筑竖井或墙体通道，专供消防排烟及事故通风排风管使用。"
      },
      {
        "dimension": "气密物理与感控边界",
        "focus": "六面体无缝隙防渗漏",
        "requirement": "实验室的墙壁、天花板和地面应平整、易清洁、不渗水、耐化学品和消毒剂的腐蚀。",
        "source": "《实验室生物安全通用要求》GB 19489-2008第6.2.2条",
        "suggestion": "整个PCR实验室（含缓冲间）必须形成“全封闭密闭舱”。吊顶必须为全密闭硬质彩钢板或抗菌树脂板（打硅酮结构胶），绝对严禁使用留有缝隙的矿棉板或铝扣板。"
      },
      {
        "dimension": "气密物理与感控边界",
        "focus": "医用气密门与自动闭门器",
        "requirement": "实验室的门应有可视窗并可锁闭，门锁及门的开启方向应不妨碍室内人员逃生。应设置闭门器。",
        "source": "《实验室生物安全通用要求》GB 19489-2008第6.2.5条及第6.3.2条",
        "suggestion": "所有的门（含走廊门、缓冲间门、主工作间门）必须配置带阻尼的机械闭门器。门扇底部必须配置下沉式自动扫地密封条，确保在机电系统建立压差时，建筑界面不漏气。"
      },
      {
        "dimension": "气密物理与感控边界",
        "focus": "全密闭防气溶胶观察窗",
        "requirement": "实验室应有可视窗。",
        "source": "《实验室生物安全通用要求》GB 19489-2008第6.2.5条",
        "suggestion": "为了减少门开启的频次，各工作区通向外走廊的隔墙上应设置大面积玻璃观察窗。窗户必须为双层中空钢化玻璃且绝对物理死封（不可开启）。"
      },
      {
        "dimension": "室内装修",
        "focus": "地材抗生物腐蚀与防静电",
        "requirement": "医疗用房的地面应平整、防滑、易清洁、耐磨、耐腐蚀、不产尘。地面不应设地垄沟。",
        "source": "《综合医院建筑设计标准》GB 51039-2014第5.1.10条",
        "suggestion": "PCR室内极易滴洒高浓度消毒液和核酸提取液。地面必须满铺2.0mm以上的同质透心抗化学腐蚀PVC卷材。接缝热熔无缝焊接，上卷上墙形成圆弧阴角。"
      },
      {
        "dimension": "室内装修",
        "focus": "洗眼器与深水池配置",
        "requirement": "实验室应配备紧急洗眼装置，应在操作区就近设置洗手池。",
        "source": "《实验室生物安全通用要求》GB 19489-2008第6.2.8条及第6.3.4条",
        "suggestion": "标本制备区和产物分析区这种高危操作区域内，必须强制配置非接触式洗手池，并在旁边或水龙头上集成“紧急洗眼器”。水槽深度需大于250mm以防飞沫溅出。"
      }
    ],
    "glbModel": "glb/mt-lab-prc.glb",
    "legacySiteModel": "models/model-real.html?space=ct",
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 45,
      "priority": "P0",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 47,
      "finalStatus": "部分完成",
      "finalRequirement": "各区设备与传递关系一一对应；补压差、门禁互锁和单向检测流程。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）",
    "glbModelDisabled": true,
    "glbModelDisabledReason": "2026-07-13 GLB 包围核查发现尺度、原点或游离构件异常；程序场景保留，清理并统一米制重导前禁用实景切换。",
    "glbAuditStatus": "隔离待重导"
  },
  {
    "id": "mt_lab_center",
    "dept": "医技",
    "name": "检验采血中心",
    "type": "lab",
    "priority": "P0",
    "summary": "检验采血中心审图重点包括医患双走廊绝对物理隔离、大空间单向不折返动线、候诊面积极限压力测试等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.4.1条；《综合医院建筑设计标准》GB 51039-2014 第5.1.1条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [],
    "rules": [
      "area",
      "child",
      "infection",
      "clean"
    ],
    "siteModel": "models/viewer.html?scene=mt-lab-center",
    "siteModelName": "3D交互信息模型（检验采血中心·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "检验采血中心审图重点包括医患双走廊绝对物理隔离、大空间单向不折返动线、候诊面积极限压力测试等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.4.1条；《综合医院建筑设计标准》GB 51039-2014 第5.1.1条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "医患双走廊绝对物理隔离：放射科、核医学科、超声科等医技科室，应设医护人员专用通道。",
      "大空间单向不折返动线：医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理、洁污路线清楚。",
      "候诊面积极限压力测试：候诊处应设面积不小于1.5㎡/人的等候区。儿科候诊区面积应按不小于2㎡/人设计。",
      "聚集极峰期的疏散走道净宽：疏散走道、疏散出口的净宽度应满足人员安全疏散的要求。走道净宽不应小于2.40m。",
      "核心检验区的高级别防火分隔：医院中的手术部、急诊部、重症监护室、贵重精密医疗设备用房等，应采用防火隔墙和不燃楼板与其他部位分隔。",
      "疏散门的无障碍平接：疏散出口门、疏散走道中的门应向疏散方向开启，且不应设置门槛。"
    ],
    "docReview": [
      "动线与分流 / 医患双走廊绝对物理隔离：必须规划清晰的“前端（采血大厅）”与“后端（检验核心试验区）”。后端必须设置医护专属的门禁入口、更衣换鞋缓冲间与内部走廊，严禁医护人员穿行拥挤的采血大厅上下班。",
      "动线与分流 / 大空间单向不折返动线：采血大厅必须设立“独立入口”与“独立出口”。图纸必须能在平面上画出一条（取号打印 → 排队等候 → 窗口采血 → 靠墙按压止血 → 顺向离开）的U型或L型单向闭环动线，严防“袋形尽端”布局导致的动线逆向对冲。",
      "动线与分流 / 候诊面积极限压力测试：必须按照“早高峰禁食采血”的极值人流进行空间测算。采血窗口前方的垂直纵深排队区，其实际净深度必须大于或等于3.00m（容纳患儿+双家长+婴儿车的复合排队单元）。",
      "防火分隔与应急疏散 / 聚集极峰期的疏散走道净宽：考虑到采血大厅存在大量推车及行动迟缓群体，其通向安全出口的主疏散走道，在剔除等候座椅、自助机柜等所有突出物后，实打实的物理净宽必须大于或等于3.00m。",
      "防火分隔与应急疏散 / 核心检验区的高级别防火分隔：检验科内部（含生化、免疫、微生物等实验室）存放有大量精密仪器与危险化学试剂。其与外部采血大厅及公共区域的物理交界面，必须为耐火极限不低于2.00h的防爆防火实体墙。",
      "防火分隔与应急疏散 / 疏散门的无障碍平接：采血大厅的所有疏散双开门或自动平移门必须向疏散方向开启。门下地面必须绝对零门槛平接，确保早高峰一旦发生突发火情，大量婴儿车能被家长推行平滑逃离。",
      "物理环境 / 大跨度空间防混响声学顶棚：采血大厅是全院哭闹声最密集的区域（极易产生“多点共振”的声学现象）。大厅吊顶必须满铺NRC（降噪系数）大于或等于0.8的A级不燃吸音材料，且墙体1.20m以上部位宜采用微孔吸音板，遏制恐慌情绪传染。",
      "物理环境 / 全明采光与自然通风边界：采血大厅作为极高密度的人员聚集区，建筑外立面设计必须保证候诊区拥有大面积的外窗。有效可开启窗地面积比不应小于1/10，以满足流感高发季的自然通风稀释要求。"
    ],
    "docReviewRows": [
      {
        "dimension": "动线与分流",
        "focus": "医患双走廊绝对物理隔离",
        "requirement": "放射科、核医学科、超声科等医技科室，应设医护人员专用通道。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.4.1条",
        "suggestion": "必须规划清晰的“前端（采血大厅）”与“后端（检验核心试验区）”。后端必须设置医护专属的门禁入口、更衣换鞋缓冲间与内部走廊，严禁医护人员穿行拥挤的采血大厅上下班。"
      },
      {
        "dimension": "动线与分流",
        "focus": "大空间单向不折返动线",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理、洁污路线清楚。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "采血大厅必须设立“独立入口”与“独立出口”。图纸必须能在平面上画出一条（取号打印 → 排队等候 → 窗口采血 → 靠墙按压止血 → 顺向离开）的U型或L型单向闭环动线，严防“袋形尽端”布局导致的动线逆向对冲。"
      },
      {
        "dimension": "动线与分流",
        "focus": "候诊面积极限压力测试",
        "requirement": "候诊处应设面积不小于1.5㎡/人的等候区。儿科候诊区面积应按不小于2㎡/人设计。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.4.1条及第5.2.6条",
        "suggestion": "必须按照“早高峰禁食采血”的极值人流进行空间测算。采血窗口前方的垂直纵深排队区，其实际净深度必须大于或等于3.00m（容纳患儿+双家长+婴儿车的复合排队单元）。"
      },
      {
        "dimension": "防火分隔与应急疏散",
        "focus": "聚集极峰期的疏散走道净宽",
        "requirement": "疏散走道、疏散出口的净宽度应满足人员安全疏散的要求。走道净宽不应小于2.40m。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.4条及GB 51039第5.1.2条",
        "suggestion": "考虑到采血大厅存在大量推车及行动迟缓群体，其通向安全出口的主疏散走道，在剔除等候座椅、自助机柜等所有突出物后，实打实的物理净宽必须大于或等于3.00m。"
      },
      {
        "dimension": "防火分隔与应急疏散",
        "focus": "核心检验区的高级别防火分隔",
        "requirement": "医院中的手术部、急诊部、重症监护室、贵重精密医疗设备用房等，应采用防火隔墙和不燃楼板与其他部位分隔。",
        "source": "《建筑防火通用规范》GB 55037-2022 第4.3.1条",
        "suggestion": "检验科内部（含生化、免疫、微生物等实验室）存放有大量精密仪器与危险化学试剂。其与外部采血大厅及公共区域的物理交界面，必须为耐火极限不低于2.00h的防爆防火实体墙。"
      },
      {
        "dimension": "防火分隔与应急疏散",
        "focus": "疏散门的无障碍平接",
        "requirement": "疏散出口门、疏散走道中的门应向疏散方向开启，且不应设置门槛。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.2.1条",
        "suggestion": "采血大厅的所有疏散双开门或自动平移门必须向疏散方向开启。门下地面必须绝对零门槛平接，确保早高峰一旦发生突发火情，大量婴儿车能被家长推行平滑逃离。"
      },
      {
        "dimension": "物理环境",
        "focus": "大跨度空间防混响声学顶棚",
        "requirement": "综合医院注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
        "source": "《综合医院建设标准》建标110-2021 第五条",
        "suggestion": "采血大厅是全院哭闹声最密集的区域（极易产生“多点共振”的声学现象）。大厅吊顶必须满铺NRC（降噪系数）大于或等于0.8的A级不燃吸音材料，且墙体1.20m以上部位宜采用微孔吸音板，遏制恐慌情绪传染。"
      },
      {
        "dimension": "物理环境",
        "focus": "全明采光与自然通风边界",
        "requirement": "医疗用房应通风良好。采取有效措施防止交叉感染。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第7.1.1条",
        "suggestion": "采血大厅作为极高密度的人员聚集区，建筑外立面设计必须保证候诊区拥有大面积的外窗。有效可开启窗地面积比不应小于1/10，以满足流感高发季的自然通风稀释要求。"
      }
    ],
    "legacySiteModel": "models/model-real.html?space=ct",
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 32,
      "priority": "P0",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 34,
      "finalStatus": "部分完成",
      "finalRequirement": "候诊退出门区；绑定两个窗口的工作人员/患者；补晕厥处置流线。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）",
    "sceneInfo": {
      "modelScope": "关系模型",
      "measurementNotice": "仅表达科室分区、邻接与流程关系，不可用于房间净距或设备安装量测。"
    }
  },
  {
    "id": "mt_microbiology",
    "dept": "医技",
    "name": "微生物实验室",
    "type": "lab",
    "priority": "P0",
    "summary": "微生物实验室审图重点包括生物安全柜（BSC）的占位与退让、结核/肠道致病菌独立接种舱、大型温控设备的散热凹槽等内容；依据《实验室 生物安全通用要求》GB 19489-2008 第6.3.3条；《综合医院建筑设计标准》GB 51039-2014 第5.1.1条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [],
    "rules": [
      "area",
      "handwash",
      "child",
      "infection"
    ],
    "siteModel": "models/viewer.html?scene=mt-microbiology",
    "siteModelName": "3D交互信息模型（微生物实验室·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "微生物实验室审图重点包括生物安全柜（BSC）的占位与退让、结核/肠道致病菌独立接种舱、大型温控设备的散热凹槽等内容；依据《实验室 生物安全通用要求》GB 19489-2008 第6.3.3条；《综合医院建筑设计标准》GB 51039-2014 第5.1.1条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "生物安全柜（BSC）的占位与退让：实验室的布局应满足操作人员的安全和设备安全运行的要求。",
      "结核/肠道致病菌独立接种舱：医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
      "大型温控设备的散热凹槽：建筑结构设计应满足医疗设备安装的要求。",
      "“原位灭菌”的物理硬隔离：实验室应设置高压蒸汽灭菌器或其他适用的消毒灭菌设备。",
      "废弃物的“不折返”污染出口：医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理、洁污路线清楚。",
      "高压灭菌室的独立防火防爆：医院中的重症监护室、贵重精密医疗设备用房等，应采用防火隔墙与其他部位分隔。"
    ],
    "docReview": [
      "空间模数与布局 / 生物安全柜（BSC）的占位与退让：BSC的建筑占位严禁正对门窗、严禁紧贴人员频繁走动的通道。BSC两侧及后方必须预留不小于0.30m的物理间距（供维修测试），上方距顶棚至少预留0.30m排风管道空间。",
      "空间模数与布局 / 结核/肠道致病菌独立接种舱：针对结核杆菌（极易气溶胶传染）与肠道粪便样本（极度恶臭），建筑平面必须在主实验室内部，硬性切割出带玻璃隔墙与闭门器的“独立接种舱”，实现物理空间与视线的“双重隔离”。",
      "空间模数与布局 / 大型温控设备的散热凹槽：微生物室四周放置着海量的恒温培养箱与超低位冰箱。平面图必须在墙体一侧规划深度大于或等于0.80m的“设备内嵌槽”，设备背后需预留0.15m散热空隙，严防设备机身凸出阻塞主走廊。",
      "动线与感控屏障 / “原位灭菌”的物理硬隔离：所有含活菌的废弃培养基必须“先灭菌、后出室”。实验室末端必须设置独立的“洗消/高压灭菌室”。该室必须与无菌准备区绝对物理隔离，防止灭菌产生的高温高湿蒸汽反噬污染洁净区。",
      "动线与感控屏障 / 废弃物的“不折返”污染出口：高压灭菌后的废弃物必须拥有一扇直接通向外部污物走廊的“专属单向出口门”。绝对严禁保洁人员推着刚出锅的废弃物原路折返，穿过主实验区或洁净走廊运出。",
      "防火分隔与逃生 / 高压灭菌室的独立防火防爆：洗消灭菌室内的高压蒸汽灭菌锅属于高压特种容器，存在物理爆炸风险。该房间的外围实体墙必须为耐火极限不低于2.00h的防爆实体墙，且门扇需向外开启。",
      "防火分隔与逃生 / 高等级感控区的逃生距离：穿越微生物室的所有废液管、通风管的穿墙及穿楼板孔洞，必须使用兼具防渗漏与阻燃功能的防火泥进行双面全密实封堵，确保生物安全屏障与防火屏障的双重完整性。",
      "室内装修 / 六面体抗腐蚀与无缝界面：地面必须满铺耐强酸碱的同质透心PVC卷材并上卷上墙。墙面与吊顶严禁使用易吸潮、易长霉的材料，必须采用抗菌涂层金属板或医用树脂板，所有板缝必须用防霉硅酮胶绝对密封，消除细菌藏匿死角。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与布局",
        "focus": "生物安全柜（BSC）的占位与退让",
        "requirement": "实验室的布局应满足操作人员的安全和设备安全运行的要求。",
        "source": "《实验室 生物安全通用要求》GB 19489-2008 第6.3.3条",
        "suggestion": "BSC的建筑占位严禁正对门窗、严禁紧贴人员频繁走动的通道。BSC两侧及后方必须预留不小于0.30m的物理间距（供维修测试），上方距顶棚至少预留0.30m排风管道空间。"
      },
      {
        "dimension": "空间模数与布局",
        "focus": "结核/肠道致病菌独立接种舱",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "针对结核杆菌（极易气溶胶传染）与肠道粪便样本（极度恶臭），建筑平面必须在主实验室内部，硬性切割出带玻璃隔墙与闭门器的“独立接种舱”，实现物理空间与视线的“双重隔离”。"
      },
      {
        "dimension": "空间模数与布局",
        "focus": "大型温控设备的散热凹槽",
        "requirement": "建筑结构设计应满足医疗设备安装的要求。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第4.3.2条",
        "suggestion": "微生物室四周放置着海量的恒温培养箱与超低位冰箱。平面图必须在墙体一侧规划深度大于或等于0.80m的“设备内嵌槽”，设备背后需预留0.15m散热空隙，严防设备机身凸出阻塞主走廊。"
      },
      {
        "dimension": "动线与感控屏障",
        "focus": "“原位灭菌”的物理硬隔离",
        "requirement": "实验室应设置高压蒸汽灭菌器或其他适用的消毒灭菌设备。",
        "source": "《实验室 生物安全通用要求》GB 19489-2008 第6.2.7条",
        "suggestion": "所有含活菌的废弃培养基必须“先灭菌、后出室”。实验室末端必须设置独立的“洗消/高压灭菌室”。该室必须与无菌准备区绝对物理隔离，防止灭菌产生的高温高湿蒸汽反噬污染洁净区。"
      },
      {
        "dimension": "动线与感控屏障",
        "focus": "废弃物的“不折返”污染出口",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理、洁污路线清楚。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "高压灭菌后的废弃物必须拥有一扇直接通向外部污物走廊的“专属单向出口门”。绝对严禁保洁人员推着刚出锅的废弃物原路折返，穿过主实验区或洁净走廊运出。"
      },
      {
        "dimension": "防火分隔与逃生",
        "focus": "高压灭菌室的独立防火防爆",
        "requirement": "医院中的重症监护室、贵重精密医疗设备用房等，应采用防火隔墙与其他部位分隔。",
        "source": "《建筑防火通用规范》GB 55037-2022 第4.3.1条",
        "suggestion": "洗消灭菌室内的高压蒸汽灭菌锅属于高压特种容器，存在物理爆炸风险。该房间的外围实体墙必须为耐火极限不低于2.00h的防爆实体墙，且门扇需向外开启。"
      },
      {
        "dimension": "防火分隔与逃生",
        "focus": "高等级感控区的逃生距离",
        "requirement": "建筑内各类管线穿过楼板的孔洞应采用防火封堵材料封堵。",
        "source": "《建筑防火通用规范》GB 55037-2022 第6.3.1条",
        "suggestion": "穿越微生物室的所有废液管、通风管的穿墙及穿楼板孔洞，必须使用兼具防渗漏与阻燃功能的防火泥进行双面全密实封堵，确保生物安全屏障与防火屏障的双重完整性。"
      },
      {
        "dimension": "室内装修",
        "focus": "六面体抗腐蚀与无缝界面",
        "requirement": "实验室的墙壁、天花板和地面应平整、易清洁、不渗水、耐化学品和消毒剂的腐蚀。",
        "source": "《实验室 生物安全通用要求》GB 19489-2008 第6.2.2条",
        "suggestion": "地面必须满铺耐强酸碱的同质透心PVC卷材并上卷上墙。墙面与吊顶严禁使用易吸潮、易长霉的材料，必须采用抗菌涂层金属板或医用树脂板，所有板缝必须用防霉硅酮胶绝对密封，消除细菌藏匿死角。"
      },
      {
        "dimension": "室内装修",
        "focus": "防溅大纵深染色水槽",
        "requirement": "医疗用房的洗手盆应采取防止污水外溅的措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第6.2.6条",
        "suggestion": "微生物室的“涂片染色区”常年使用革兰氏染液（结晶紫、碘液）。必须强制配置深度大于或等于0.30m、材质为黑色抗倍特板或316L不锈钢的加深型洗刷槽，彻底杜绝染液飞溅导致台面及地面永久性染色。"
      },
      {
        "dimension": "人机工效与安全终端",
        "focus": "物理强制洗眼器与冲淋装置",
        "requirement": "实验室应配备紧急洗眼装置，应在操作区就近设置洗手池。BSL-2实验室宜设置紧急冲淋装置。",
        "source": "《实验室 生物安全通用要求》GB 19489-2008 第6.2.8及6.3.4条",
        "suggestion": "在微生物标本处理区（如血液培养、痰液处理台）半径10米范围内，必须实打实地落地安装连通建筑给水的紧急洗眼器与全身冲淋花洒。严禁仅配置洗眼壶敷衍审查。"
      },
      {
        "dimension": "人机工效与安全终端",
        "focus": "自动闭门器与防飞沫气密门",
        "requirement": "实验室的门应有可视窗并可锁闭。应设置闭门器。",
        "source": "《实验室 生物安全通用要求》GB 19489-2008 第6.2.5条及第6.3.2条",
        "suggestion": "通向走廊及各功能分区的房门必须标配机械阻尼闭门器。门下沿必须配置自动扫地条，确保人员进出后房门自动严密闭合，防止恶臭及潜在气溶胶飘入公共办公区。"
      }
    ],
    "legacySiteModel": "models/model-real.html?space=ct",
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 38,
      "priority": "P0",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 40,
      "finalStatus": "部分完成",
      "finalRequirement": "洗手与洗眼分离；补压差、门禁、灭菌状态以及标本/废物单向流线。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "mt_mri",
    "dept": "医技",
    "name": "MRI扫描间",
    "type": "imaging",
    "priority": "P0",
    "summary": "MRI扫描间以Zone 1-4单向准入组织；3D模型已补入磁体、无磁检查床、线圈柜、5高斯警示、铁磁筛查门禁、RF观察窗、失超排放管、无磁急救车、外置医气接口、影像数据流和设备冷却/排风动画。",
    "assets": [],
    "rules": [
      "area",
      "privacy",
      "child",
      "infection"
    ],
    "siteModel": "models/viewer.html?scene=mt-mri",
    "siteModelName": "3D交互信息模型（MRI扫描间·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "MRI扫描间审图重点包括操作空间与磁体面宽、大型磁体吊装入口预留、操作视线与监控死角等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.1.1条；《综合医院建筑设计标准》GB 51039-2014 第4.3.2条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "操作空间与磁体面宽：医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
      "大型磁体吊装入口预留：建筑结构设计应满足医疗设备、悬挂装置等对荷载及安装的要求。",
      "操作视线与监控死角：医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
      "屏蔽门的断电开启与净宽：疏散出口门、疏散走道中的门应向疏散方向开启。",
      "机房独立防火分隔：医院中的手术部、急诊部、重症监护室、贵重精密医疗设备用房等，应采用防火隔墙和不燃楼板与其他部位分隔。",
      "消防灭火设施的空间排除：建筑内部装修不应擅自减少、改动、拆除、遮挡消防设施或器材及其标识。"
    ],
    "docReview": [
      "空间模数与布局 / 操作空间与磁体面宽：扫描室单间净使用面积通常不应小于35.00㎡。考虑到儿童MRI检查常需配置无磁麻醉机、无磁监护仪及陪护家属，磁体两侧必须预留大于或等于1.50m的净操作通道。",
      "空间模数与布局 / 大型磁体吊装入口预留：磁体体积巨大无法通过普通走廊。建筑平面及立面图上必须硬性规划出“设备吊装口”或“墙体预留拆卸通道”，其净宽不应小于2.50m，高不应小于2.50m。",
      "空间模数与布局 / 操作视线与监控死角：控制室与扫描室之间必须设置射频屏蔽观察窗。观察窗必须确保技师在坐姿状态下，视线能越过高耸的磁体孔径，完整观察到检查床上的患儿及床尾的麻醉设备。",
      "防火分隔与逃生 / 屏蔽门的断电开启与净宽：屏蔽门异常沉重且带有气囊密封垫。门洞开启净宽必须大于或等于1.20m。主屏蔽门必须为向外开启（外开门），并确保在断电、失超形成负压的极端情况下，人力能够通过机械把手强行推开。",
      "防火分隔与逃生 / 机房独立防火分隔：MRI机房必须采用耐火极限不低于2.00h的防爆防火实体墙与其他区域分隔。",
      "防火分隔与逃生 / 消防灭火设施的空间排除：常规的干粉灭火器及钢制消火栓箱带有强磁性，若图纸上把它们画进了扫描室内，吸入磁体将造成灾难。此类设施必须硬性规定布置在扫描室外的二区或三区，室内仅可配备专用的无磁灭火器。",
      "室内装修与防磁安全 / 绝对无磁的室内装修材料：屏蔽网内侧的所有装修基层必须使用铝合金、黄铜或木质材料，严禁图纸中出现任何包含铁磁性材质的说明。",
      "室内装修与防磁安全 / 极限噪音的吸音降噪处理：MRI扫描噪音极其剧烈，极易惊醒镇静患儿。室内墙面及吊顶必须满铺高厚度、高NRC系数的非磁性吸音材料，将混响降至最低。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与布局",
        "focus": "操作空间与磁体面宽",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "扫描室单间净使用面积通常不应小于35.00㎡。考虑到儿童MRI检查常需配置无磁麻醉机、无磁监护仪及陪护家属，磁体两侧必须预留大于或等于1.50m的净操作通道。"
      },
      {
        "dimension": "空间模数与布局",
        "focus": "大型磁体吊装入口预留",
        "requirement": "建筑结构设计应满足医疗设备、悬挂装置等对荷载及安装的要求。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第4.3.2条",
        "suggestion": "磁体体积巨大无法通过普通走廊。建筑平面及立面图上必须硬性规划出“设备吊装口”或“墙体预留拆卸通道”，其净宽不应小于2.50m，高不应小于2.50m。"
      },
      {
        "dimension": "空间模数与布局",
        "focus": "操作视线与监控死角",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "控制室与扫描室之间必须设置射频屏蔽观察窗。观察窗必须确保技师在坐姿状态下，视线能越过高耸的磁体孔径，完整观察到检查床上的患儿及床尾的麻醉设备。"
      },
      {
        "dimension": "防火分隔与逃生",
        "focus": "屏蔽门的断电开启与净宽",
        "requirement": "疏散出口门、疏散走道中的门应向疏散方向开启。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.2.1条",
        "suggestion": "屏蔽门异常沉重且带有气囊密封垫。门洞开启净宽必须大于或等于1.20m。主屏蔽门必须为向外开启（外开门），并确保在断电、失超形成负压的极端情况下，人力能够通过机械把手强行推开。"
      },
      {
        "dimension": "防火分隔与逃生",
        "focus": "机房独立防火分隔",
        "requirement": "医院中的手术部、急诊部、重症监护室、贵重精密医疗设备用房等，应采用防火隔墙和不燃楼板与其他部位分隔。",
        "source": "《建筑防火通用规范》GB 55037-2022 第4.3.1条",
        "suggestion": "MRI机房必须采用耐火极限不低于2.00h的防爆防火实体墙与其他区域分隔。"
      },
      {
        "dimension": "防火分隔与逃生",
        "focus": "消防灭火设施的空间排除",
        "requirement": "建筑内部装修不应擅自减少、改动、拆除、遮挡消防设施或器材及其标识。",
        "source": "《建筑防火通用规范》GB 55037-2022 第6.5.1条（引申至磁场安全）",
        "suggestion": "常规的干粉灭火器及钢制消火栓箱带有强磁性，若图纸上把它们画进了扫描室内，吸入磁体将造成灾难。此类设施必须硬性规定布置在扫描室外的二区或三区，室内仅可配备专用的无磁灭火器。"
      },
      {
        "dimension": "室内装修与防磁安全",
        "focus": "绝对无磁的室内装修材料",
        "requirement": "磁共振成像室（MRI）的建筑构造应符合设备对磁场屏蔽的要求。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.14条",
        "suggestion": "屏蔽网内侧的所有装修基层必须使用铝合金、黄铜或木质材料，严禁图纸中出现任何包含铁磁性材质的说明。"
      },
      {
        "dimension": "室内装修与防磁安全",
        "focus": "极限噪音的吸音降噪处理",
        "requirement": "综合医院注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
        "source": "《综合医院建设标准》建标110-2021 第五条",
        "suggestion": "MRI扫描噪音极其剧烈，极易惊醒镇静患儿。室内墙面及吊顶必须满铺高厚度、高NRC系数的非磁性吸音材料，将混响降至最低。"
      },
      {
        "dimension": "室内装修与防磁安全",
        "focus": "地材抗压与防静电平接",
        "requirement": "医疗用房的地面应平整、防滑、易清洁、耐磨、耐腐蚀、不产尘，部分医疗用房地面应防静电。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.10条",
        "suggestion": "地面必须采用防静电、高耐压的同质透心卷材。屏蔽地网的施工面极易产生高差，必须通过建筑找平，确保机房内外地面绝对平接，保证无磁推床与麻醉机平稳无震动推入。"
      },
      {
        "dimension": "物理屏蔽与建筑构造",
        "focus": "射频屏蔽（法拉第笼）边界",
        "requirement": "磁共振成像室（MRI）的建筑构造应符合设备对磁场屏蔽的要求。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.14条",
        "suggestion": "MRI不需要防辐射铅板，但必须在墙、地、顶六个面构建无缝隙的铜板/铜网“射频屏蔽层（法拉第笼）”。图纸必须标明屏蔽层的建筑预留厚度（通常需在原墙基上内退100mm-150mm）。"
      },
      {
        "dimension": "物理屏蔽与建筑构造",
        "focus": "失超管的建筑空间通道",
        "requirement": "磁共振成像室（MRI）的建筑构造应符合设备对磁场屏蔽的要求。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.14条（引申至磁体安全构造）",
        "suggestion": "超导磁体发生紧急状况（失超）时会瞬间喷出极低温液氦气体。建筑剖面图必须为“失超管”预留一条尽可能笔直、不穿越其他安全出口、直通室外安全高空的独立空间通道。"
      },
      {
        "dimension": "物理屏蔽与建筑构造",
        "focus": "地台垫层与微震动控制",
        "requirement": "建筑结构设计应满足医疗设备、悬挂装置等对荷载及安装的要求。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第4.3.2条",
        "suggestion": "磁体极重（往往超过5吨）且对震动极度敏感。机房底板必须进行特殊承重加固（承载力需达到10-15kN/㎡以上），且周围15米内建筑平面严禁布置水泵房、电梯井等振动源。"
      }
    ],
    "glbModel": "glb/mt-mri.glb",
    "legacySiteModel": "models/model-real.html?space=ct",
    "docBehaviors": [
      "患者从公共等候进入Zone 2筛查/更衣，清除铁磁物品后进入Zone 3控制边界，再进入Zone 4磁体扫描室。",
      "技师通过RF观察窗、摄像和对讲管理患者，线圈取放从线圈柜到磁体后回收，避免无磁附件与普通推车混用。",
      "无磁急救车和医用气体接口布置在Zone 3或门外可控位置，常规含铁急救设备不得进入Zone 4。",
      "失超排放管与设备冷却路径独立表达，避免把MRI只当成“不需要铅板的CT房间”。"
    ],
    "modelDetail": {
      "referenceGranularity": "参照儿童手术室模型的“洁净分区/气流/设备吊塔”表达方式，改写为MRI磁安全分区、RF屏蔽和失超安全表达。",
      "roomZones": [
        "Zone 1公共等候",
        "Zone 2筛查更衣",
        "Zone 3控制观察",
        "Zone 4磁体扫描室",
        "设备冷却/RF接口",
        "无磁准备/应急位"
      ],
      "equipment": [
        "MRI磁体与内孔",
        "无磁检查床",
        "头颈线圈",
        "线圈柜",
        "铁磁筛查门禁",
        "5高斯线标识",
        "失超排放管",
        "无磁转运车",
        "外置医气/急救接口",
        "RF观察窗"
      ],
      "animatedFlows": [
        "患者Zone 1→2→3→4",
        "技师控制→观察→扫描床",
        "无磁附件线圈柜→磁体→回收",
        "影像数据→PACS",
        "设备冷却/失超排放"
      ],
      "checkPoints": [
        "铁磁物品筛查",
        "无磁急救边界",
        "RF屏蔽连续性",
        "失超管直达室外",
        "磁体两侧操作通道"
      ]
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 44,
      "priority": "P0",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 46,
      "finalStatus": "部分完成",
      "finalRequirement": "更衣柜和陪护退出门区；补 RF/铁磁报警；GLB 重导出前以程序化场景为准。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）",
    "glbModelDisabled": true,
    "glbModelDisabledReason": "2026-07-13 GLB 包围核查发现尺度、原点或游离构件异常；程序场景保留，清理并统一米制重导前禁用实景切换。",
    "glbAuditStatus": "隔离待重导"
  },
  {
    "id": "mt_or",
    "dept": "医技",
    "name": "标准手术室",
    "type": "or",
    "priority": "P1",
    "summary": "标准手术室审图重点包括手术间面积底线与长宽比、吊顶净高与设备安装极限、大型悬挂设备的结构预埋等内容；依据《医院洁净手术部建筑技术规范》GB 50333-2013 第4.2.1条；《医院洁净手术部建筑技术规范》GB 50333-2013 第8.1.1条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/医技/CAD/标准手术室_t3_t3.dwg",
      "docs/materials/2026.7.6/医技/模型/标准手术室.skp"
    ],
    "rules": [
      "area",
      "handwash",
      "child",
      "infection"
    ],
    "siteModel": "models/viewer.html?scene=mt-or",
    "siteModelName": "3D交互信息模型（标准手术室·新版）",
    "legacySiteModel": "models/site/model-or.html",
    "docBrief": "标准手术室审图重点包括手术间面积底线与长宽比、吊顶净高与设备安装极限、大型悬挂设备的结构预埋等内容；依据《医院洁净手术部建筑技术规范》GB 50333-2013 第4.2.1条；《医院洁净手术部建筑技术规范》GB 50333-2013 第8.1.1条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "手术间面积底线与长宽比：洁净手术室的净面积不宜过大或过小。",
      "吊顶净高与设备安装极限：洁净手术室的净高不宜低于2.7m。",
      "大型悬挂设备的结构预埋：建筑结构应满足医疗设备及悬挂装置等对荷载及安装的要求。",
      "生命孤岛的独立防火墙：医院中的手术部等，应采用防火隔墙和不燃楼板与其他部位分隔。",
      "穿墙管线防烟防气双重封堵：建筑内各类管线穿过防火墙、隔墙的孔洞应采用防火封堵材料封堵。",
      "医用自动气密门与脚踏开关：洁净手术室应采用自动悬挂式平移气密门。门洞净宽不应小于1.4m。"
    ],
    "docBehaviors": [
      "家长陪同患儿在洁净入口处完成诱导麻醉后经专用通道退出",
      "外科医生在送风天花保护区内完成高精度无菌操作",
      "麻醉师在床头侧连续监测呼吸、循环、体温和麻醉废气",
      "无菌物品由洁净走廊进入，术后污物从专用污物通道密闭撤出"
    ],
    "docReview": [
      "空间模数与净空 / 手术间面积底线与长宽比：儿童标准手术室（III级）单间净面积建议控制在30.00㎡至35.00㎡。平面长宽比不宜大于1.2，确保手术床位于送风天花正下方且周边留有大于或等于1.20m的医护循环通道。",
      "空间模数与净空 / 吊顶净高与设备安装极限：考虑到手术无影灯及双悬臂吊塔的旋转半径与机械臂高度，室内吊顶完成面净高必须严格控制在2.80m至3.00m之间。过低会导致设备碰头，过高会导致层流送风衰减。",
      "空间模数与净空 / 大型悬挂设备的结构预埋：建筑与结构图纸必须联动审查。手术床正上方的混凝土楼板内，必须提前规划并预埋用于承载无影灯及麻醉/外科吊塔的重型钢结构转换层（受力骨架），严禁后期用膨胀螺栓直接打在空心楼板上。",
      "防火分隔与封堵 / 生命孤岛的独立防火墙：整个手术部外围及各手术间之间的隔墙，必须为耐火极限不低于2.00h的实体防火隔墙，且墙面电解钢板及内部龙骨必须为A级不燃材料。",
      "防火分隔与封堵 / 穿墙管线防烟防气双重封堵：手术室内密布麻醉废气管、氧气管、IT弱电线缆。所有穿透墙板的管线缝隙，必须使用高弹性防火密封胶进行全密实封堵，确保火灾时不漏烟气，平时不漏无菌冷气。",
      "气密边界与门窗 / 医用自动气密门与脚踏开关：主出入口必须配置带防夹功能的电动平移气密门。开门开关必须是墙面底部的“非接触式脚踏开关”或“近距离感应开关”，严防洗手后的外科医生用手触碰污染。门扇底部必须有下沉式密封胶条。",
      "气密边界与门窗 / 标本与污物互锁传递窗：在手术室通向污物走廊的后墙上，必须嵌入安装机械互锁式双扉传递窗。用于术中快速递出病理冰冻标本或术后递出污染敷料，减少主门开启频次。",
      "室内装修 / 六面体无缝抗菌电解钢板：手术室墙面及吊顶严禁使用常规腻子涂料或普通板材。必须满铺定制拼接的“防菌电解钢板”或“医疗级抗倍特板”。所有拼缝必须采用抗氧化硅酮结构胶绝对密封，实现墙顶地一体化的“气密舱”。"
    ],
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "手术间面积底线与长宽比",
        "requirement": "洁净手术室的净面积不宜过大或过小。",
        "source": "《医院洁净手术部建筑技术规范》GB 50333-2013 第4.2.1条",
        "suggestion": "儿童标准手术室（III级）单间净面积建议控制在30.00㎡至35.00㎡。平面长宽比不宜大于1.2，确保手术床位于送风天花正下方且周边留有大于或等于1.20m的医护循环通道。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "吊顶净高与设备安装极限",
        "requirement": "洁净手术室的净高不宜低于2.7m。",
        "source": "《医院洁净手术部建筑技术规范》GB 50333-2013 第8.1.1条",
        "suggestion": "考虑到手术无影灯及双悬臂吊塔的旋转半径与机械臂高度，室内吊顶完成面净高必须严格控制在2.80m至3.00m之间。过低会导致设备碰头，过高会导致层流送风衰减。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "大型悬挂设备的结构预埋",
        "requirement": "建筑结构应满足医疗设备及悬挂装置等对荷载及安装的要求。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第4.3.2条",
        "suggestion": "建筑与结构图纸必须联动审查。手术床正上方的混凝土楼板内，必须提前规划并预埋用于承载无影灯及麻醉/外科吊塔的重型钢结构转换层（受力骨架），严禁后期用膨胀螺栓直接打在空心楼板上。"
      },
      {
        "dimension": "防火分隔与封堵",
        "focus": "生命孤岛的独立防火墙",
        "requirement": "医院中的手术部等，应采用防火隔墙和不燃楼板与其他部位分隔。",
        "source": "《建筑防火通用规范》GB 55037-2022 第4.3.1条",
        "suggestion": "整个手术部外围及各手术间之间的隔墙，必须为耐火极限不低于2.00h的实体防火隔墙，且墙面电解钢板及内部龙骨必须为A级不燃材料。"
      },
      {
        "dimension": "防火分隔与封堵",
        "focus": "穿墙管线防烟防气双重封堵",
        "requirement": "建筑内各类管线穿过防火墙、隔墙的孔洞应采用防火封堵材料封堵。",
        "source": "《建筑防火通用规范》GB 55037-2022 第6.3.1条",
        "suggestion": "手术室内密布麻醉废气管、氧气管、IT弱电线缆。所有穿透墙板的管线缝隙，必须使用高弹性防火密封胶进行全密实封堵，确保火灾时不漏烟气，平时不漏无菌冷气。"
      },
      {
        "dimension": "气密边界与门窗",
        "focus": "医用自动气密门与脚踏开关",
        "requirement": "洁净手术室应采用自动悬挂式平移气密门。门洞净宽不应小于1.4m。",
        "source": "《医院洁净手术部建筑技术规范》GB 50333-2013 第8.3.1条及8.3.2条",
        "suggestion": "主出入口必须配置带防夹功能的电动平移气密门。开门开关必须是墙面底部的“非接触式脚踏开关”或“近距离感应开关”，严防洗手后的外科医生用手触碰污染。门扇底部必须有下沉式密封胶条。"
      },
      {
        "dimension": "气密边界与门窗",
        "focus": "标本与污物互锁传递窗",
        "requirement": "洁净区与非洁净区之间应设传递窗。",
        "source": "《医院洁净手术部建筑技术规范》GB 50333-2013 第5.2.5条",
        "suggestion": "在手术室通向污物走廊的后墙上，必须嵌入安装机械互锁式双扉传递窗。用于术中快速递出病理冰冻标本或术后递出污染敷料，减少主门开启频次。"
      },
      {
        "dimension": "室内装修",
        "focus": "六面体无缝抗菌电解钢板",
        "requirement": "洁净手术室的墙面和天花板应平整、光滑、无裂隙、防眩光、防霉、防潮、易清洁。",
        "source": "《医院洁净手术部建筑技术规范》GB 50333-2013 第8.2.2条",
        "suggestion": "手术室墙面及吊顶严禁使用常规腻子涂料或普通板材。必须满铺定制拼接的“防菌电解钢板”或“医疗级抗倍特板”。所有拼缝必须采用抗氧化硅酮结构胶绝对密封，实现墙顶地一体化的“气密舱”。"
      },
      {
        "dimension": "室内装修",
        "focus": "地材抗静电与导电网预埋",
        "requirement": "洁净手术室地面应平整、防滑、防静电、耐磨、耐腐蚀。",
        "source": "《医院洁净手术部建筑技术规范》GB 50333-2013 第8.2.4条",
        "suggestion": "地面必须采用2.0mm以上的同质透心防静电PVC或橡胶卷材。在铺设地材前，建筑垫层内必须预埋“导电铜箔网”并直接接入建筑接地系统，消除高频电刀使用时的静电电火花风险。"
      },
      {
        "dimension": "室内装修",
        "focus": "极限R角与暗装工艺",
        "requirement": "墙体转角和门的竖向边缘宜为圆角。",
        "source": "《医院洁净手术部建筑技术规范》GB 50333-2013 第8.2.2条",
        "suggestion": "室内所有阴阳角（墙与墙、墙与地、墙与顶）必须全部执行R≥30mm的圆弧过渡。情报面板、观片灯、医用气体终端盒必须与墙面齐平“绝对暗装”，严禁任何凸出墙面的积尘死角。"
      }
    ],
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 28,
      "priority": "P1",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 30,
      "finalStatus": "部分完成",
      "finalRequirement": "明确刷手/更衣边界；吊塔、无影灯、器械台与输液架增加状态；补麻醉废气排放。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "mt_or_center",
    "dept": "医技",
    "name": "洁净手术中心",
    "type": "or",
    "priority": "P0",
    "summary": "洁净手术中心审图重点包括三区划分与物理边界、医/患/物三流线分明、麻醉诱导与家长陪护空间等内容；依据《洁净手术部建筑技术规范》GB 50333-2013 第5.1.1/5.1.3条；《综合医院建筑设计标准》GB 51039-2014 第5.4.2条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [],
    "rules": [
      "area",
      "handwash",
      "child",
      "infection"
    ],
    "siteModel": "models/viewer.html?scene=mt-or-center",
    "siteModelName": "3D交互信息模型（洁净手术中心·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "洁净手术中心审图重点包括三区划分与物理边界、医/患/物三流线分明、麻醉诱导与家长陪护空间等内容；依据《洁净手术部建筑技术规范》GB 50333-2013 第5.1.1/5.1.3条；《综合医院建筑设计标准》GB 51039-2014 第5.4.2条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "三区划分与物理边界：洁净手术部应分为洁净区与非洁净区。洁净手术部平面布置应符合功能流程、洁污分明。",
      "医/患/物三流线分明：洁净手术部的功能流程应符合人流、物流分开和洁污分明的原则。",
      "麻醉诱导与家长陪护空间：综合医院注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
      "患儿换车/换床换鞋缓冲：洁净手术部内应设人流和物流缓冲室。",
      "强制性单向更衣动线：医务人员入口应设换鞋、更衣、淋浴及卫生间。",
      "刷手位视线与空间预留：刷手间不应设门。刷手池应紧邻手术室入口。"
    ],
    "docReview": [
      "分区与屏障 / 三区划分与物理边界：必须明确限制区（手术间、洁净走廊）、半限制区（洗手、更衣、库房）与非限制区（家属等候、办公）的界限。各区交界处必须设置物理屏障（门或气锁）。",
      "分区与屏障 / 医/患/物三流线分明：必须在平面图上清晰勾勒出医护、患儿、洁净物品、污物四条独立动线，严禁在限制区内发生交叉或逆流。",
      "患儿与家属流线 / 麻醉诱导与家长陪护空间：必须在限制区入口处设置独立的“适儿化麻醉诱导间”。需预留家属换鞋后进入陪护的空间，确保患儿在熟悉的人安抚下完成麻醉，降低术前应激。",
      "患儿与家属流线 / 患儿换车/换床换鞋缓冲：患儿由病房进入手术部必须经过“换车/换床”或“轮椅转换”环节。平面图应标示出明确的转运车停靠位及脚踏式自动感应门的缓冲区。",
      "医护人员流线（流程放最前面） / 强制性单向更衣动线：医护入口必须设计为“单向强迫式流线”：换鞋 → 一更（脱私服） → 淋浴/卫生间 → 二更（穿手术服） → 缓冲/洗手。严禁不经过二更直接进入洁净走廊。",
      "医护人员流线（流程放最前面） / 刷手位视线与空间预留：刷手位宜设在洁净走廊内手术室门侧。每间手术室应对应至少2个刷手位。刷手区地面应做防滑处理并设医疗专用排水槽，严禁积水。",
      "防火分隔与应急 / 手术部独立防火分区：洁净手术部必须作为独立的防火分区。其围护墙体必须为耐火极限不低于2.00h的防火隔墙，且跨越防火分区的管线必须实施全密实封堵。",
      "防火分隔与应急 / 大纵深走廊的疏散净宽：洁净走廊与污物走廊作为生命通道，其物理净宽在剔除消火栓、洗手台突出物后，必须实打实地大于或等于2.40m，建议3.00m以满足平车错车需求。"
    ],
    "docReviewRows": [
      {
        "dimension": "分区与屏障",
        "focus": "三区划分与物理边界",
        "requirement": "洁净手术部应分为洁净区与非洁净区。洁净手术部平面布置应符合功能流程、洁污分明。",
        "source": "《洁净手术部建筑技术规范》GB 50333-2013 第5.1.1/5.1.3条",
        "suggestion": "必须明确限制区（手术间、洁净走廊）、半限制区（洗手、更衣、库房）与非限制区（家属等候、办公）的界限。各区交界处必须设置物理屏障（门或气锁）。"
      },
      {
        "dimension": "分区与屏障",
        "focus": "医/患/物三流线分明",
        "requirement": "洁净手术部的功能流程应符合人流、物流分开和洁污分明的原则。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.4.2条",
        "suggestion": "必须在平面图上清晰勾勒出医护、患儿、洁净物品、污物四条独立动线，严禁在限制区内发生交叉或逆流。"
      },
      {
        "dimension": "患儿与家属流线",
        "focus": "麻醉诱导与家长陪护空间",
        "requirement": "综合医院注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
        "source": "《综合医院建设标准》建标110-2021 第五条",
        "suggestion": "必须在限制区入口处设置独立的“适儿化麻醉诱导间”。需预留家属换鞋后进入陪护的空间，确保患儿在熟悉的人安抚下完成麻醉，降低术前应激。"
      },
      {
        "dimension": "患儿与家属流线",
        "focus": "患儿换车/换床换鞋缓冲",
        "requirement": "洁净手术部内应设人流和物流缓冲室。",
        "source": "《洁净手术部建筑技术规范》GB 50333-2013 第5.2.2条",
        "suggestion": "患儿由病房进入手术部必须经过“换车/换床”或“轮椅转换”环节。平面图应标示出明确的转运车停靠位及脚踏式自动感应门的缓冲区。"
      },
      {
        "dimension": "医护人员流线（流程放最前面）",
        "focus": "强制性单向更衣动线",
        "requirement": "医务人员入口应设换鞋、更衣、淋浴及卫生间。",
        "source": "《洁净手术部建筑技术规范》GB 50333-2013 第5.2.1条",
        "suggestion": "医护入口必须设计为“单向强迫式流线”：换鞋 → 一更（脱私服） → 淋浴/卫生间 → 二更（穿手术服） → 缓冲/洗手。严禁不经过二更直接进入洁净走廊。"
      },
      {
        "dimension": "医护人员流线（流程放最前面）",
        "focus": "刷手位视线与空间预留",
        "requirement": "刷手间不应设门。刷手池应紧邻手术室入口。",
        "source": "《洁净手术部建筑技术规范》GB 50333-2013 第5.2.3条及第8.2.3条",
        "suggestion": "刷手位宜设在洁净走廊内手术室门侧。每间手术室应对应至少2个刷手位。刷手区地面应做防滑处理并设医疗专用排水槽，严禁积水。"
      },
      {
        "dimension": "防火分隔与应急",
        "focus": "手术部独立防火分区",
        "requirement": "手术部应采用防火隔墙和不燃楼板与其他部位分隔。",
        "source": "《建筑防火通用规范》GB 55037-2022 第4.3.1条",
        "suggestion": "洁净手术部必须作为独立的防火分区。其围护墙体必须为耐火极限不低于2.00h的防火隔墙，且跨越防火分区的管线必须实施全密实封堵。"
      },
      {
        "dimension": "防火分隔与应急",
        "focus": "大纵深走廊的疏散净宽",
        "requirement": "疏散走道、疏散出口的净宽度应满足人员安全疏散的要求。走道净宽不应小于2.40m。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.4条",
        "suggestion": "洁净走廊与污物走廊作为生命通道，其物理净宽在剔除消火栓、洗手台突出物后，必须实打实地大于或等于2.40m，建议3.00m以满足平车错车需求。"
      },
      {
        "dimension": "防火分隔与应急",
        "focus": "防烟与正压控制逻辑",
        "requirement": "洁净手术部应设防烟感应及排烟系统。",
        "source": "《洁净手术部建筑技术规范》GB 50333-2013 第12.0.1条",
        "suggestion": "且火灾时防排烟系统必须确保洁净区相对于非洁净区仍保持一定的正压，防止烟气涌入手术间。"
      }
    ],
    "legacySiteModel": "models/model-real.html?space=or",
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 33,
      "priority": "P0",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 35,
      "finalStatus": "未修改到位",
      "finalRequirement": "明确关系模型或建立真实洁净/污物走廊及门禁；污物流线远离 PACU，补床位关系。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "建立实体洁净/污物分区与门禁关系，缩窄污物走廊以消除 PACU 墙体重叠。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）",
    "sceneInfo": {
      "modelScope": "关系模型",
      "measurementNotice": "仅表达科室分区、邻接与流程关系，不可用于房间净距或设备安装量测。"
    }
  },
  {
    "id": "mt_recovery",
    "dept": "医技",
    "name": "麻醉复苏区",
    "type": "ward",
    "priority": "P3",
    "summary": "麻醉复苏区审图重点包括FCC床旁陪护极限模数、抢救车与仪器专属壁龛、护士站无死角全景视野等内容；依据《综合医院建筑设计标准》GB 51039第5.3.11条及建标110-2021第五条；《综合医院建筑设计标准》GB 51039-2014 第5.1.1条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/医技/术后恢复_t3.dwg"
    ],
    "rules": [
      "area",
      "handwash",
      "privacy",
      "child"
    ],
    "siteModel": "models/viewer.html?scene=mt-recovery",
    "siteModelName": "3D交互信息模型（麻醉复苏区·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "麻醉复苏区审图重点包括FCC床旁陪护极限模数、抢救车与仪器专属壁龛、护士站无死角全景视野等内容；依据《综合医院建筑设计标准》GB 51039第5.3.11条及建标110-2021第五条；《综合医院建筑设计标准》GB 51039-2014 第5.1.1条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "FCC床旁陪护极限模数：抢救床净间距不应小于1.20m。综合医院注重改善患者的就医环境。充分考虑使用人群的生理特点。",
      "抢救车与仪器专属壁龛：医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
      "护士站无死角全景视野：护理单元应设护士站……护士站应与治疗室、办公用房邻近。",
      "大纵深连床疏散净宽：疏散走道、疏散出口的净宽度应满足人员安全疏散的要求。走道净宽不应小于2.40m。",
      "主出入口的零门槛感应门：通向推床的门净宽不应小于1.10m，疏散出口门应为平开门或在火灾时具有平开功能的门，且不应设置门槛。",
      "高等级装修阻燃标准：医疗建筑内部装修材料的燃烧性能等级不应低于A级，部分部位不应低于B1级。"
    ],
    "docReview": [
      "空间模数与阵列 / FCC床旁陪护极限模数：为满足FCC理念（允许双家长在床旁安抚），单床净使用面积必须放大至15.00㎡至18.00㎡。相邻病床间距必须大于或等于1.50m，确保放置探视椅后不阻挡医护抢救操作。",
      "空间模数与阵列 / 抢救车与仪器专属壁龛：平面图纸必须在非承重墙体或柱间缝隙，向内退让设计深度大于或等于0.60m的“抢救车、除颤仪及移动超声专属壁龛”，严禁重型仪器占用PACU疏散主通道。",
      "空间模数与阵列 / 护士站无死角全景视野：PACU护士站必须采用中心岛式或半岛式布局。台面高度必须保证护士在坐姿状态下，视线能无物理死角地覆盖室内所有的复苏床位，以便第一时间发现患儿呕吐或窒息。",
      "防火分隔与应急疏散 / 大纵深连床疏散净宽：PACU内主通道必须满足两辆带有输液架的手术平车同时全速错车。剔除所有墙面突出物（如洗手池、护士台挑檐）后，实际物理净宽必须大于或等于2.40m（建议按3.00m控制）。",
      "防火分隔与应急疏散 / 主出入口的零门槛感应门：通向PACU的主门及通向家属等候区的双开大门，净宽必须大于或等于1.50m。门下地面必须绝对零门槛平接处理，确保术后患儿平稳推入时不发生颠簸惊跳。",
      "防火分隔与应急疏散 / 高等级装修阻燃标准：PACU内含氧量高且有大量电气设备，吊顶及墙面基层必须全部采用A级不燃材料。床位间的隐私隔帘必须出具B1级以上的阻燃洗涤检测报告（洗涤多次后仍阻燃）。",
      "感控边界与物理隔离 / 单间隔离复苏室（接触/飞沫）：针对患有流感、水痘或多重耐药菌的需手术患儿，PACU内部必须硬性切分出至少1间（或按比例配置）带有全玻璃物理隔断及自动闭门器的“独立隔离复苏间”。",
      "感控边界与物理隔离 / 洗消终端与防溅屏障：开敞式大空间PACU必须按每4至6床配置一个独立的非接触式洗手池。水池必须加装防溅侧板，并在侧墙预留感应式手部消毒液与擦手纸的建筑挂点。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与阵列",
        "focus": "FCC床旁陪护极限模数",
        "requirement": "抢救床净间距不应小于1.20m。综合医院注重改善患者的就医环境。充分考虑使用人群的生理特点。",
        "source": "《综合医院建筑设计标准》GB 51039第5.3.11条及建标110-2021第五条",
        "suggestion": "为满足FCC理念（允许双家长在床旁安抚），单床净使用面积必须放大至15.00㎡至18.00㎡。相邻病床间距必须大于或等于1.50m，确保放置探视椅后不阻挡医护抢救操作。"
      },
      {
        "dimension": "空间模数与阵列",
        "focus": "抢救车与仪器专属壁龛",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "平面图纸必须在非承重墙体或柱间缝隙，向内退让设计深度大于或等于0.60m的“抢救车、除颤仪及移动超声专属壁龛”，严禁重型仪器占用PACU疏散主通道。"
      },
      {
        "dimension": "空间模数与阵列",
        "focus": "护士站无死角全景视野",
        "requirement": "护理单元应设护士站……护士站应与治疗室、办公用房邻近。",
        "source": "《儿童医院建设标准》建标174-2016 第28条",
        "suggestion": "PACU护士站必须采用中心岛式或半岛式布局。台面高度必须保证护士在坐姿状态下，视线能无物理死角地覆盖室内所有的复苏床位，以便第一时间发现患儿呕吐或窒息。"
      },
      {
        "dimension": "防火分隔与应急疏散",
        "focus": "大纵深连床疏散净宽",
        "requirement": "疏散走道、疏散出口的净宽度应满足人员安全疏散的要求。走道净宽不应小于2.40m。",
        "source": "《建筑防火通用规范》GB 55037-2022 第7.1.4条及GB 51039第5.1.2条",
        "suggestion": "PACU内主通道必须满足两辆带有输液架的手术平车同时全速错车。剔除所有墙面突出物（如洗手池、护士台挑檐）后，实际物理净宽必须大于或等于2.40m（建议按3.00m控制）。"
      },
      {
        "dimension": "防火分隔与应急疏散",
        "focus": "主出入口的零门槛感应门",
        "requirement": "通向推床的门净宽不应小于1.10m，疏散出口门应为平开门或在火灾时具有平开功能的门，且不应设置门槛。",
        "source": "《综合医院建筑设计标准》第5.1.4条及《建筑防火通用规范》第7.2.1条",
        "suggestion": "通向PACU的主门及通向家属等候区的双开大门，净宽必须大于或等于1.50m。门下地面必须绝对零门槛平接处理，确保术后患儿平稳推入时不发生颠簸惊跳。"
      },
      {
        "dimension": "防火分隔与应急疏散",
        "focus": "高等级装修阻燃标准",
        "requirement": "医疗建筑内部装修材料的燃烧性能等级不应低于A级，部分部位不应低于B1级。",
        "source": "《建筑防火通用规范》GB 55037-2022 第6.1.1条",
        "suggestion": "PACU内含氧量高且有大量电气设备，吊顶及墙面基层必须全部采用A级不燃材料。床位间的隐私隔帘必须出具B1级以上的阻燃洗涤检测报告（洗涤多次后仍阻燃）。"
      },
      {
        "dimension": "感控边界与物理隔离",
        "focus": "单间隔离复苏室（接触/飞沫）",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理、洁污路线清楚。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "针对患有流感、水痘或多重耐药菌的需手术患儿，PACU内部必须硬性切分出至少1间（或按比例配置）带有全玻璃物理隔断及自动闭门器的“独立隔离复苏间”。"
      },
      {
        "dimension": "感控边界与物理隔离",
        "focus": "洗消终端与防溅屏障",
        "requirement": "医疗用房的洗手盆应采用非手动开关，水龙头不应采取充气式，并应采取防止污水外溅的措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第6.2.5及6.2.6条",
        "suggestion": "开敞式大空间PACU必须按每4至6床配置一个独立的非接触式洗手池。水池必须加装防溅侧板，并在侧墙预留感应式手部消毒液与擦手纸的建筑挂点。"
      },
      {
        "dimension": "室内声光与心理干预",
        "focus": "抗苏醒躁动的声学顶棚",
        "requirement": "综合医院注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
        "source": "《综合医院建设标准》建标110-2021 第五条",
        "suggestion": "患儿全麻苏醒期极易发生谵妄哭闹（导致声场共振）。吊顶必须满铺NRC（降噪系数）大于或等于0.8的微孔吸音抗菌板，隔墙必须砌筑至楼板底，切断哭闹声波的跨房间穿透。"
      },
      {
        "dimension": "室内声光与心理干预",
        "focus": "防眩光漫反射苏醒照明",
        "requirement": "医疗用房应采用高显色照明光源，显色指数应大于或等于80。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第8.6.2条",
        "suggestion": "处于半梦半醒状态的患儿对光线极度敏感。复苏床正上方绝对严禁设置直射点光源，必须采用向上打光或带防眩光罩的漫反射照明系统；且必须支持无极调光（苏醒期极暗，抢救时极亮）。"
      },
      {
        "dimension": "室内声光与心理干预",
        "focus": "天轨隔帘的U型隐私闭环",
        "requirement": "检查、治疗用房应满足使用人群的隐私要求。房间内宜设置隔帘或屏风。",
        "source": "《综合医院建设标准》建标110-2021 第三十九条（八）",
        "suggestion": "每张复苏床天花板必须预埋受力构件并安装全包围U型隔帘轨道。提供哺乳、换尿布或极度焦躁患儿所需的隐私屏障。隔帘底部必须离地0.20m以上，确保护士巡视时能看见患儿脚部。"
      },
      {
        "dimension": "室内装修与防撞防护",
        "focus": "地材抗静电与耐推床碾压",
        "requirement": "洁净手术部地面应平整、防滑、防静电、耐磨、耐腐蚀。",
        "source": "《医院洁净手术部建筑技术规范》GB 50333-2013 第8.2.4条（引申适用区域）",
        "suggestion": "PACU地面必须采用厚度大于或等于2.0mm的同质透心防静电PVC卷材（铺设防静电铜网），上卷上墙15cm形成圆弧阴角。要求具备极高的抗轮压性能，防止重型麻醉床长期停放产生压痕。"
      },
      {
        "dimension": "室内装修与防撞防护",
        "focus": "阴阳角防撞与设备带背板",
        "requirement": "其阴阳角宜做成圆角。有推床或推车通过的门和墙面，应采取防碰撞措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.12条及第39条（三）",
        "suggestion": "室内所有墙角必须执行半径大于或等于30mm的强化圆角工艺。床头墙面（医用气体设备带下方）必须满铺高强度抗撞击医用树脂板，防止推床撞碎墙面基层。"
      }
    ],
    "legacySiteModel": "models/model-real.html?space=ward",
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 34,
      "priority": "P3",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 36,
      "finalStatus": "部分完成",
      "finalRequirement": "隔离床位形成围护；补护士与抢救人员；监护/气体仅保留合理设备接触。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "mt_section",
    "dept": "医技",
    "name": "切片室",
    "type": "lab",
    "priority": "P3",
    "summary": "病理切片或实验处理空间，关注通风、污染控制、样本路径和设备台面。",
    "assets": [
      "docs/materials/医技/切片_t3.dwg"
    ],
    "rules": [
      "infection",
      "construction",
      "handwash"
    ],
    "siteModel": "models/viewer.html?scene=mt-section",
    "siteModelName": "3D交互信息模型（切片室·新版）",
    "legacySiteModel": "models/model-real.html?space=ct",
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 35,
      "priority": "P3",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 37,
      "finalStatus": "部分完成",
      "finalRequirement": "分开取材与包埋；补洗眼/应急设施、设备检修外廓与信息。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "mt_specimen",
    "dept": "医技",
    "name": "标本接收窗口",
    "type": "lab",
    "priority": "P2",
    "summary": "标本接收窗口审图重点包括血、尿、便窗口的物理分流、操作台面进深与置物退让、自动化物流系统的建筑占位等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.1.1条；《综合医院建筑设计标准》GB 51039-2014 第4.3.2条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [],
    "rules": [
      "handwash",
      "child",
      "infection",
      "nursing"
    ],
    "siteModel": "models/viewer.html?scene=mt-specimen",
    "siteModelName": "3D交互信息模型（标本接收窗口·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "标本接收窗口审图重点包括血、尿、便窗口的物理分流、操作台面进深与置物退让、自动化物流系统的建筑占位等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.1.1条；《综合医院建筑设计标准》GB 51039-2014 第4.3.2条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "血、尿、便窗口的物理分流：医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理、洁污路线清楚。",
      "操作台面进深与置物退让：医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
      "自动化物流系统的建筑占位：建筑结构设计应满足医疗设备安装的要求。",
      "高等级防火物理边界：医院中的重症监护室、贵重精密医疗设备用房等，应采用防火隔墙和其他部位分隔。",
      "气动管网的穿墙/穿板防火封堵：建筑内各类管线穿过防火墙、防火隔墙、楼板的孔洞应采用防火封堵材料封堵。",
      "全封闭防飞沫气溶胶屏障：实验室的布局应满足操作人员的安全和设备安全运行的要求。"
    ],
    "docReview": [
      "空间模数与阵列 / 血、尿、便窗口的物理分流：建筑平面必须将“血液标本接收”与“尿便体液接收”在物理空间上拉开距离（建议相隔2米以上或设转角）。严禁混合在同一长条窗口，防止排泄物异味引发排队家属及患儿的反胃呕吐。",
      "空间模数与阵列 / 操作台面进深与置物退让：接收台面宽度不应小于0.60m（以容纳试管架与扫码枪）。面向患儿家属的外侧，必须在台面下方0.15m处，外挑设置宽度约0.25m的“置物板/放包台”，方便家长放置沉重的母婴包后腾出手递交标本。",
      "空间模数与阵列 / 自动化物流系统的建筑占位：接收窗口内侧必须为“气动传输系统（PTS）”或“轨道物流”的接收工作站预留建筑平面占位（通常需预留1.0m x 1.0m的落地或台面空间），严防物流机柜侵占检验员的坐姿退让空间。",
      "防火分隔与封堵 / 高等级防火物理边界：标本接收窗口所在的墙体，本质上是“公共大厅”与“核心检验区（精密设备与危化品库区）”的物理分界线。该墙体必须为实体防火墙（耐火极限不低于2.00h），镶嵌的玻璃也必须提供同等耐火极限的防火检测报告。",
      "防火分隔与封堵 / 气动管网的穿墙/穿板防火封堵：气动物流传输管道（直径通常约110mm-160mm）穿过楼板或防火隔墙进入接收站时，其建筑开孔缝隙必须使用阻火圈及防火膨胀模块进行全密实封堵，严防火灾时的烟囱效应。",
      "物理边界与感控 / 全封闭防飞沫气溶胶屏障：接收窗口的台面以上至吊顶区间，必须采用全封闭钢化玻璃进行物理隔断，严禁采用敞开式或半敞开式柜台。切断内外气流交换，保护检验员免受飞沫及气溶胶感染。",
      "物理边界与感控 / 弧形传递槽与互锁传递窗：玻璃隔断上严禁直接开大孔。递交零散采血管必须通过台面下凹的“U型或弧形防风传递槽”；递交大件标本转运箱，必须通过嵌在墙体或玻璃上的“机械互锁双扉传递窗”。",
      "物理边界与感控 / 无孔化双向语音对讲预留：既然玻璃是全封闭的，建筑图纸（弱电配合）就必须在玻璃两侧的墙体或台面上预留“双向语音对讲系统”的安装暗盒与走线管。严禁在防护玻璃上打“百叶孔”用来传声（会漏气）。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与阵列",
        "focus": "血、尿、便窗口的物理分流",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理、洁污路线清楚。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "建筑平面必须将“血液标本接收”与“尿便体液接收”在物理空间上拉开距离（建议相隔2米以上或设转角）。严禁混合在同一长条窗口，防止排泄物异味引发排队家属及患儿的反胃呕吐。"
      },
      {
        "dimension": "空间模数与阵列",
        "focus": "操作台面进深与置物退让",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程，应做到功能分区合理。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "接收台面宽度不应小于0.60m（以容纳试管架与扫码枪）。面向患儿家属的外侧，必须在台面下方0.15m处，外挑设置宽度约0.25m的“置物板/放包台”，方便家长放置沉重的母婴包后腾出手递交标本。"
      },
      {
        "dimension": "空间模数与阵列",
        "focus": "自动化物流系统的建筑占位",
        "requirement": "建筑结构设计应满足医疗设备安装的要求。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第4.3.2条",
        "suggestion": "接收窗口内侧必须为“气动传输系统（PTS）”或“轨道物流”的接收工作站预留建筑平面占位（通常需预留1.0m x 1.0m的落地或台面空间），严防物流机柜侵占检验员的坐姿退让空间。"
      },
      {
        "dimension": "防火分隔与封堵",
        "focus": "高等级防火物理边界",
        "requirement": "医院中的重症监护室、贵重精密医疗设备用房等，应采用防火隔墙和其他部位分隔。",
        "source": "《建筑防火通用规范》GB 55037-2022 第4.3.1条",
        "suggestion": "标本接收窗口所在的墙体，本质上是“公共大厅”与“核心检验区（精密设备与危化品库区）”的物理分界线。该墙体必须为实体防火墙（耐火极限不低于2.00h），镶嵌的玻璃也必须提供同等耐火极限的防火检测报告。"
      },
      {
        "dimension": "防火分隔与封堵",
        "focus": "气动管网的穿墙/穿板防火封堵",
        "requirement": "建筑内各类管线穿过防火墙、防火隔墙、楼板的孔洞应采用防火封堵材料封堵。",
        "source": "《建筑防火通用规范》GB 55037-2022 第6.3.1条",
        "suggestion": "气动物流传输管道（直径通常约110mm-160mm）穿过楼板或防火隔墙进入接收站时，其建筑开孔缝隙必须使用阻火圈及防火膨胀模块进行全密实封堵，严防火灾时的烟囱效应。"
      },
      {
        "dimension": "物理边界与感控",
        "focus": "全封闭防飞沫气溶胶屏障",
        "requirement": "实验室的布局应满足操作人员的安全和设备安全运行的要求。",
        "source": "《实验室 生物安全通用要求》GB 19489-2008 第6.3.3条",
        "suggestion": "接收窗口的台面以上至吊顶区间，必须采用全封闭钢化玻璃进行物理隔断，严禁采用敞开式或半敞开式柜台。切断内外气流交换，保护检验员免受飞沫及气溶胶感染。"
      },
      {
        "dimension": "物理边界与感控",
        "focus": "弧形传递槽与互锁传递窗",
        "requirement": "实验室各区之间的传递应通过传递窗。",
        "source": "《医疗机构临床基因扩增检验实验室工作导则》（引申至高危标本接收）",
        "suggestion": "玻璃隔断上严禁直接开大孔。递交零散采血管必须通过台面下凹的“U型或弧形防风传递槽”；递交大件标本转运箱，必须通过嵌在墙体或玻璃上的“机械互锁双扉传递窗”。"
      },
      {
        "dimension": "物理边界与感控",
        "focus": "无孔化双向语音对讲预留",
        "requirement": "综合医院注重改善患者的就医环境。充分考虑使用人群的生理特点及心理特点。",
        "source": "《综合医院建设标准》建标110-2021 第五条",
        "suggestion": "既然玻璃是全封闭的，建筑图纸（弱电配合）就必须在玻璃两侧的墙体或台面上预留“双向语音对讲系统”的安装暗盒与走线管。严禁在防护玻璃上打“百叶孔”用来传声（会漏气）。"
      },
      {
        "dimension": "室内装修",
        "focus": "台面的极限抗污与防溢水构造",
        "requirement": "实验室的墙壁、天花板和地面应平整、易清洁、不渗水、耐化学品和消毒剂的腐蚀。",
        "source": "《实验室 生物安全通用要求》GB 19489-2008 第6.2.2条",
        "suggestion": "接收台面必须采用无缝拼接的医用级人造石或高密度抗倍特板。台面靠墙侧及临边必须做一体成型的“防溢水挡水条”，彻底防止标本漏液、血液滴洒后顺着台面缝隙流到下方的暗柜里发臭。"
      },
      {
        "dimension": "室内装修",
        "focus": "洗消终端与紧急洗眼器",
        "requirement": "实验室应配备紧急洗眼装置，应在操作区就近设置洗手池。",
        "source": "《实验室 生物安全通用要求》GB 19489-2008 第6.2.8条及第6.3.4条",
        "suggestion": "在接收窗口内侧检验员的步行安全距离内（通常为半径5米），必须硬性规划洗手池，并在水槽边固定安装连接建筑给水的紧急洗眼器（应对标本喷溅事故）。"
      }
    ],
    "legacySiteModel": "models/model-real.html?space=ct",
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 27,
      "priority": "P2",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 29,
      "finalStatus": "未修改到位",
      "finalRequirement": "重建三个独立窗口，名称、热点、排队线和标本台面一一对应。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "建立三个独立窗口，并将名称、热点、排队线和标本台面逐一对应。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "mt_sterile_dressing",
    "dept": "医技",
    "name": "无菌敷料间",
    "type": "clinic",
    "priority": "P2",
    "summary": "无菌敷料间审图重点包括无菌车回旋与取物通道净宽、嵌入式无菌柜的建筑退让、高火灾荷载的独立防火舱等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.1.1条；《医院洁净手术部建筑技术规范》GB 50333-2013 第8.2.6条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [],
    "rules": [
      "area",
      "child",
      "infection",
      "clean"
    ],
    "siteModel": "models/viewer.html?scene=mt-sterile-dressing",
    "siteModelName": "3D交互信息模型（无菌敷料间·新版）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "无菌敷料间审图重点包括无菌车回旋与取物通道净宽、嵌入式无菌柜的建筑退让、高火灾荷载的独立防火舱等内容；依据《综合医院建筑设计标准》GB 51039-2014 第5.1.1条；《医院洁净手术部建筑技术规范》GB 50333-2013 第8.2.6条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "无菌车回旋与取物通道净宽：医疗各项功能用房的设置应符合医疗工艺流程。",
      "嵌入式无菌柜的建筑退让：洁净手术部内的储物柜宜嵌入暗装。",
      "高火灾荷载的独立防火舱：医院中的手术部等，应采用防火隔墙和不燃楼板与其他部位分隔。",
      "防紫外线衰老与无紫外线冷光源：照明光源的显色指数应大于或等于90。",
      "六面体零缝隙与绝对防产尘：洁净手术部的墙面和天花板应平整、光滑、无裂隙、防霉、防潮、易清洁。",
      "非接触式感应气密门：洁净手术部内与室内洁净度级别相同的房间，其门应能自动关闭。"
    ],
    "docReview": [
      "空间模数与阵列 / 无菌车回旋与取物通道净宽：室内必须为“无菌物品转运推车”预留足够的操作空间。两排无菌储物架之间的物理净通道宽度必须大于或等于1.20m，确保护士在打开柜门取物时，推车能顺畅通行而不发生无菌包磕碰。",
      "空间模数与阵列 / 嵌入式无菌柜的建筑退让：建筑平面图必须在墙体上规划深度为0.45m至0.60m的“建筑壁龛（凹槽）”。无菌储物柜必须与墙面平齐嵌入安装，绝对严禁采用外凸式的独立家具柜，消除柜顶与柜背后的卫生死角。",
      "防火分隔与照明 / 高火灾荷载的独立防火舱：无菌敷料间内存放着大量全棉纱布、无纺布手术衣等极易燃物资，是手术部内火灾荷载最大的区域之一。其外围包裹墙体必须为耐火极限不低于2.00h的实体防火隔墙，且内部装修材料必须全部为A级不燃。",
      "防火分隔与照明 / 防紫外线衰老与无紫外线冷光源：敷料和一次性医疗耗材的塑料外包装在长期强光或紫外线照射下极易老化变脆甚至破损（导致无菌失效）。室内严禁设计可引入太阳直射光的自然外窗，人工照明必须采用低发热、无紫外线辐射的LED冷光源冷光面板。",
      "物理界面与感控 / 六面体零缝隙与绝对防产尘：敷料极易吸附空气中的微尘。该房间墙顶地必须视为“大号保温盒”，墙面宜采用无缝拼接的电解钢板或医用抗菌板，拼缝打胶密封。绝对严禁使用普通乳胶漆或容易掉粉的矿棉板吊顶。",
      "物理界面与感控 / 非接触式感应气密门：通向洁净走廊的门必须为带有下沉式扫地条的气密门，且必须配置防夹自动闭门器。开门开关必须为“非接触式红外感应”或“脚踏开关”，确保护士双手抱满无菌敷料时无需用手推门。",
      "室内装修与防渗漏 / 阴阳角极限圆弧收口：室内所有墙角（墙与墙、墙与地、墙与顶）必须全部执行R≥30mm的圆弧过渡。无菌柜与地面、墙面交接处必须用防霉硅酮胶绝对封死，不留任何可通过抹布擦拭察觉的锐角缝隙。",
      "室内装修与防渗漏 / 抗静电与耐磨导电地坪：敷料摩擦及推车移动极易产生静电。地面必须满铺带有导电网的同质透心防静电PVC卷材，上卷上墙形成踢脚。材料需具备抗推车高频碾压的耐磨等级（T级）。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与阵列",
        "focus": "无菌车回旋与取物通道净宽",
        "requirement": "医疗各项功能用房的设置应符合医疗工艺流程。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.1条",
        "suggestion": "室内必须为“无菌物品转运推车”预留足够的操作空间。两排无菌储物架之间的物理净通道宽度必须大于或等于1.20m，确保护士在打开柜门取物时，推车能顺畅通行而不发生无菌包磕碰。"
      },
      {
        "dimension": "空间模数与阵列",
        "focus": "嵌入式无菌柜的建筑退让",
        "requirement": "洁净手术部内的储物柜宜嵌入暗装。",
        "source": "《医院洁净手术部建筑技术规范》GB 50333-2013 第8.2.6条",
        "suggestion": "建筑平面图必须在墙体上规划深度为0.45m至0.60m的“建筑壁龛（凹槽）”。无菌储物柜必须与墙面平齐嵌入安装，绝对严禁采用外凸式的独立家具柜，消除柜顶与柜背后的卫生死角。"
      },
      {
        "dimension": "防火分隔与照明",
        "focus": "高火灾荷载的独立防火舱",
        "requirement": "医院中的手术部等，应采用防火隔墙和不燃楼板与其他部位分隔。",
        "source": "《建筑防火通用规范》GB 55037-2022 第4.3.1条",
        "suggestion": "无菌敷料间内存放着大量全棉纱布、无纺布手术衣等极易燃物资，是手术部内火灾荷载最大的区域之一。其外围包裹墙体必须为耐火极限不低于2.00h的实体防火隔墙，且内部装修材料必须全部为A级不燃。"
      },
      {
        "dimension": "防火分隔与照明",
        "focus": "防紫外线衰老与无紫外线冷光源",
        "requirement": "照明光源的显色指数应大于或等于90。",
        "source": "《医院洁净手术部建筑技术规范》GB 50333-2013 第10.2.2条（引申）",
        "suggestion": "敷料和一次性医疗耗材的塑料外包装在长期强光或紫外线照射下极易老化变脆甚至破损（导致无菌失效）。室内严禁设计可引入太阳直射光的自然外窗，人工照明必须采用低发热、无紫外线辐射的LED冷光源冷光面板。"
      },
      {
        "dimension": "物理界面与感控",
        "focus": "六面体零缝隙与绝对防产尘",
        "requirement": "洁净手术部的墙面和天花板应平整、光滑、无裂隙、防霉、防潮、易清洁。",
        "source": "《医院洁净手术部建筑技术规范》GB 50333-2013 第8.2.2条",
        "suggestion": "敷料极易吸附空气中的微尘。该房间墙顶地必须视为“大号保温盒”，墙面宜采用无缝拼接的电解钢板或医用抗菌板，拼缝打胶密封。绝对严禁使用普通乳胶漆或容易掉粉的矿棉板吊顶。"
      },
      {
        "dimension": "物理界面与感控",
        "focus": "非接触式感应气密门",
        "requirement": "洁净手术部内与室内洁净度级别相同的房间，其门应能自动关闭。",
        "source": "《医院洁净手术部建筑技术规范》GB 50333-2013 第8.3.1条",
        "suggestion": "通向洁净走廊的门必须为带有下沉式扫地条的气密门，且必须配置防夹自动闭门器。开门开关必须为“非接触式红外感应”或“脚踏开关”，确保护士双手抱满无菌敷料时无需用手推门。"
      },
      {
        "dimension": "室内装修与防渗漏",
        "focus": "阴阳角极限圆弧收口",
        "requirement": "墙体转角和门的竖向边缘宜为圆角。",
        "source": "《医院洁净手术部建筑技术规范》GB 50333-2013 第8.2.2条",
        "suggestion": "室内所有墙角（墙与墙、墙与地、墙与顶）必须全部执行R≥30mm的圆弧过渡。无菌柜与地面、墙面交接处必须用防霉硅酮胶绝对封死，不留任何可通过抹布擦拭察觉的锐角缝隙。"
      },
      {
        "dimension": "室内装修与防渗漏",
        "focus": "抗静电与耐磨导电地坪",
        "requirement": "洁净区地面应平整、防滑、防静电、耐磨、耐腐蚀。",
        "source": "《医院洁净手术部建筑技术规范》GB 50333-2013 第8.2.4条",
        "suggestion": "敷料摩擦及推车移动极易产生静电。地面必须满铺带有导电网的同质透心防静电PVC卷材，上卷上墙形成踢脚。材料需具备抗推车高频碾压的耐磨等级（T级）。"
      }
    ],
    "legacySiteModel": "models/model-real.html?space=clinic",
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 39,
      "priority": "P2",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 41,
      "finalStatus": "未修改到位",
      "finalRequirement": "推车移至侧墙并退出门区；补拣选人员、库存与效期管理。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "推车移至侧墙，补拣选位、库存与效期终端，并校正工作位接触关系。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "wd_admission",
    "dept": "住院",
    "name": "出入院手续室",
    "type": "clinic",
    "priority": "P3",
    "summary": "出入院手续室审图重点包括手续室使用面积、办理窗口间距与通道、室内净高控制等内容；依据《综合医院建筑设计标准》GB 51039-2014 第 5.3.4 条；《综合医院建筑设计标准》GB 51039-2014 第 5.1.9 条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/住院/CAD/住院病房重绘_t3.dwg"
    ],
    "rules": [
      "area",
      "handwash",
      "privacy",
      "child"
    ],
    "siteModel": "models/viewer.html?scene=wd-admission",
    "siteModelName": "3D交互信息模型（出入院手续室 · 住院部）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "出入院手续室审图重点包括手续室使用面积、办理窗口间距与通道、室内净高控制等内容；依据《综合医院建筑设计标准》GB 51039-2014 第 5.3.4 条；《综合医院建筑设计标准》GB 51039-2014 第 5.1.9 条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "手续室使用面积：出入院手续室使用面积不应小于 15.00㎡。",
      "办理窗口间距与通道：服务窗口间距不应小于 1.20m，窗口前通道净宽不应小于 1.50m。",
      "室内净高控制：公共区域室内净高不宜低于 2.70m。",
      "手卫生设施配置：公共服务区域应设置非接触式手卫生设施，满足感控要求。",
      "通风与消毒条件：公共区域应具备良好的通风条件，便于清洁消毒。",
      "污物收集设施：公共区域应设置分类污物收集容器，存放生活垃圾与废弃单据。"
    ],
    "docReview": [
      "空间模数与净空 / 手续室使用面积：考虑儿童住院手续办理流程与家长等候需求，建议使用面积扩大至 18.00㎡至 20.00㎡，分设办理区与等候区。",
      "空间模数与净空 / 办理窗口间距与通道：服务窗口间距≥1.50m，窗口前通道净宽≥1.80m，预留轮椅停放与回转空间（≥1.2m×1.2m）。",
      "空间模数与净空 / 室内净高控制：为提升空间舒适度与通风效果，室内吊顶净高建议设定为 2.80m。",
      "感控要求与设施 / 手卫生设施配置：手续室角落配置感应洗手池与手消毒液分配器，窗口台面采用耐消毒抗菌材料，每日定时擦拭消毒。",
      "感控要求与设施 / 通风与消毒条件：采用自然通风与机械通风结合，换气次数≥6 次 / 小时；地面、墙面采用易清洁材料，无卫生死角，支持高频次消杀。",
      "感控要求与设施 / 污物收集设施：设置带盖分类垃圾桶（可回收物、其他垃圾），位置靠近出口，便于清运；配备碎纸机，废弃单据及时粉碎处理，保护隐私。",
      "室内装修与防护 / 墙地顶易洁与防撞：地面采用防滑耐磨的同质透心 PVC 卷材，墙面 1.2m 以下设防撞墙裙；所有阳角执行 R≥20mm 圆角工艺，避免儿童磕碰。",
      "室内装修与防护 / 服务窗口适配性：设置高低位服务窗口（高位 0.9m、低位 0.75m），低位窗口适配儿童与残障人士；窗口配备双向对讲系统与隐私保护屏。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "手续室使用面积",
        "requirement": "出入院手续室使用面积不应小于 15.00㎡。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.3.4 条",
        "suggestion": "考虑儿童住院手续办理流程与家长等候需求，建议使用面积扩大至 18.00㎡至 20.00㎡，分设办理区与等候区。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "办理窗口间距与通道",
        "requirement": "服务窗口间距不应小于 1.20m，窗口前通道净宽不应小于 1.50m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.3.4 条",
        "suggestion": "服务窗口间距≥1.50m，窗口前通道净宽≥1.80m，预留轮椅停放与回转空间（≥1.2m×1.2m）。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "室内净高控制",
        "requirement": "公共区域室内净高不宜低于 2.70m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.1.9 条",
        "suggestion": "为提升空间舒适度与通风效果，室内吊顶净高建议设定为 2.80m。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "手卫生设施配置",
        "requirement": "公共服务区域应设置非接触式手卫生设施，满足感控要求。",
        "source": "GB/T 39498-2020《医疗机构感染预防与控制基本准则》",
        "suggestion": "手续室角落配置感应洗手池与手消毒液分配器，窗口台面采用耐消毒抗菌材料，每日定时擦拭消毒。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "通风与消毒条件",
        "requirement": "公共区域应具备良好的通风条件，便于清洁消毒。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.1.10 条",
        "suggestion": "采用自然通风与机械通风结合，换气次数≥6 次 / 小时；地面、墙面采用易清洁材料，无卫生死角，支持高频次消杀。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "污物收集设施",
        "requirement": "公共区域应设置分类污物收集容器，存放生活垃圾与废弃单据。",
        "source": "《儿童医院建设标准》建标 174-2016 第 47 条",
        "suggestion": "设置带盖分类垃圾桶（可回收物、其他垃圾），位置靠近出口，便于清运；配备碎纸机，废弃单据及时粉碎处理，保护隐私。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "墙地顶易洁与防撞",
        "requirement": "公共区域的地面、墙面、顶棚应便于清扫；儿童区域应采取防撞措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.1.12 条",
        "suggestion": "地面采用防滑耐磨的同质透心 PVC 卷材，墙面 1.2m 以下设防撞墙裙；所有阳角执行 R≥20mm 圆角工艺，避免儿童磕碰。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "服务窗口适配性",
        "requirement": "服务窗口应设置高低位，满足不同人群使用需求。",
        "source": "《无障碍设计规范》GB 50763-2012 第 3.5.1 条",
        "suggestion": "设置高低位服务窗口（高位 0.9m、低位 0.75m），低位窗口适配儿童与残障人士；窗口配备双向对讲系统与隐私保护屏。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "等候区设施配置",
        "requirement": "公共服务区域应设置等候座椅，满足人员休息需求。",
        "source": "《综合医院建设标准》建标 110-2021 专项要求",
        "suggestion": "等候区配置儿童友好型座椅（圆角设计、高度适配），设置 2-3 组等候椅，配备小桌板与充电接口；墙面张贴手续办理流程图（图文结合）。"
      },
      {
        "dimension": "安全出口与疏散门",
        "focus": "门洞净宽与无障碍",
        "requirement": "房间门净宽不应小于 1.00m；疏散出口门不应设置门槛。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.1.4 条、《建筑防火通用规范》GB 55037-2022 第 7.2.1 条",
        "suggestion": "房间门采用双扇门，净宽≥1.2m，门下无门槛，便于轮椅与人员通行；门体设观察窗，避免开门碰撞。"
      },
      {
        "dimension": "安全出口与疏散门",
        "focus": "疏散路径畅通",
        "requirement": "房间内疏散路径无障碍物，便于紧急情况下快速撤离。",
        "source": "《建筑防火通用规范》GB 55037-2022 第 7.1.4 条",
        "suggestion": "办理区、等候区家具布置不遮挡疏散通道，通道净宽≥1.5m；紧急情况下可快速清空等候区，确保疏散顺畅。"
      },
      {
        "dimension": "建筑防火",
        "focus": "材料燃烧性能",
        "requirement": "医疗建筑内部装修材料的燃烧性能等级不应低于 A 级，部分部位不应低于 B1 级。",
        "source": "《建筑防火通用规范》GB 55037-2022 第 6.1.1 条",
        "suggestion": "顶棚、墙面、地面采用 A 级不燃材料，等候座椅、窗帘等软装选用 B1 级阻燃材料；严禁使用易燃装饰材料。"
      },
      {
        "dimension": "建筑防火",
        "focus": "消防设施配置",
        "requirement": "房间应按规范配置消防设施，避免遮挡与误触。",
        "source": "《建筑防火通用规范》GB 55037-2022 第 6.5.1 条",
        "suggestion": "房间内配置灭火器，位置醒目且便于取用；烟感探测器、喷淋头无遮挡，消防标识清晰可见，严禁遮挡。"
      }
    ],
    "legacySiteModel": "models/model-real.html?space=clinic",
    "sceneInfo": {
      "area": "5.40 × 4.20 m 一站式办理 + 家属等候 · 净高 3.00m（≈22.7㎡）",
      "dims": {
        "def": [
          5.4,
          4.2,
          3
        ],
        "min": [
          4.8,
          3.6,
          2.8
        ],
        "sugg": [
          6,
          4.8,
          3.1
        ],
        "minLabel": "模型紧凑",
        "suggLabel": "建议优化"
      },
      "markers": 6,
      "source": "2026.7.6 住院CAD/SKP + AusHFG住院/儿少/标准组件比对",
      "norms": [
        "规范底线：面积≥15㎡",
        "窗口间距≥1.20m",
        "窗口前通道≥1.50m",
        "净高≥2.70m"
      ],
      "compliance": [
        "面积差值：模型示范约22.7㎡，规范底线≥15㎡，高出约7.7㎡。",
        "口径说明：规范底线用于审图合规判断，模型示范尺寸用于表达陪护、设备、活动和维护余量，不应写成规范最低值。"
      ]
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 48,
      "priority": "P3",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 50,
      "finalStatus": "部分完成",
      "finalRequirement": "座椅与访谈桌分离；校正桌体；低位终端膝部空间退出门区。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "wd_aus",
    "dept": "住院",
    "name": "澳洲双人病房参考",
    "type": "ward",
    "priority": "P3",
    "summary": "外部参考型双人病房资料，可作为尺度、陪护与家具布置比较样本。",
    "assets": [
      "docs/materials/住院/住院病房重绘.dwg",
      "docs/materials/住院/澳洲双人病房.dwg"
    ],
    "rules": [
      "nursing",
      "accessible",
      "child"
    ],
    "siteModel": "models/viewer.html?scene=wd-aus",
    "siteModelName": "3D交互信息模型（澳洲双人病房参考 · 住院部）",
    "video": "docs/materials/住院/双人病房_2.mp4",
    "legacySiteModel": "models/model-real.html?space=ward",
    "sceneInfo": {
      "area": "7.20 × 5.40 m 双床 + 家属过夜 + 套内卫生间 · 净高 3.00m（≈38.9㎡）",
      "dims": {
        "def": [
          7.2,
          5.4,
          3
        ],
        "min": [
          6.6,
          4.8,
          2.8
        ],
        "sugg": [
          7.8,
          6,
          3.1
        ],
        "minLabel": "紧凑双床",
        "suggLabel": "陪护优化"
      },
      "markers": 5,
      "source": "2026.7.6 住院CAD/SKP + AusHFG住院/儿少/标准组件比对",
      "norms": [
        "国内复核：双人病房≥24㎡",
        "床间净距≥1.20m",
        "病房净高≥2.60m",
        "本项为澳洲参考示范"
      ],
      "compliance": [
        "面积差值：模型示范约38.9㎡，规范底线≥24㎡，高出约14.9㎡。",
        "口径说明：规范底线用于审图合规判断，模型示范尺寸用于表达陪护、设备、活动和维护余量，不应写成规范最低值。"
      ]
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 46,
      "priority": "P3",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 48,
      "finalStatus": "部分完成",
      "finalRequirement": "社交桌退出门区；补两名陪护状态；GLB 重导出前以程序化场景为准。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "wd_baby_bath",
    "dept": "住院",
    "name": "婴儿洗澡间",
    "type": "toilet",
    "priority": "P3",
    "summary": "婴儿洗澡间审图重点包括洗澡间使用面积、操作空间与间距、室内净高控制等内容；依据《儿童医院建设标准》建标 174-2016 专项要求；《综合医院建筑设计标准》GB 51039-2014 第 5.3.6 条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/住院/CAD/住院病房重绘_t3.dwg"
    ],
    "rules": [
      "area",
      "handwash",
      "privacy",
      "child"
    ],
    "siteModel": "models/viewer.html?scene=wd-baby-bath",
    "siteModelName": "3D交互信息模型（婴儿洗澡间 · 住院部）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "婴儿洗澡间审图重点包括洗澡间使用面积、操作空间与间距、室内净高控制等内容；依据《儿童医院建设标准》建标 174-2016 专项要求；《综合医院建筑设计标准》GB 51039-2014 第 5.3.6 条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "洗澡间使用面积：婴儿洗澡间使用面积不应小于 10.00㎡。",
      "操作空间与间距：婴儿洗澡池之间净距不应小于 0.80m，洗澡池与墙面净距不应小于 0.60m。",
      "室内净高控制：医疗用房室内净高不宜低于 2.60m。",
      "温湿度控制：新生儿区域应保持恒温、恒湿环境，温度 24-26℃，湿度 50%-60%。",
      "消毒设施配置：婴儿洗澡间应配备必要的消毒设施，对洗澡池、抚触台等进行消毒。",
      "手卫生与污物处理：操作区域应设置非接触式手卫生设施，污物分类收集。"
    ],
    "docReview": [
      "空间模数与净空 / 洗澡间使用面积：考虑新生儿洗澡与家长学习护理需求，建议使用面积扩大至 12.00㎡至 14.00㎡，预留家长操作与休息空间。",
      "空间模数与净空 / 操作空间与间距：洗澡池之间净距≥1.0m，洗澡池与墙面净距≥0.8m，每个洗澡池周边预留≥1.2m 操作空间，满足医护与家长协同操作。",
      "空间模数与净空 / 室内净高控制：为保障通风与减少压抑感，同时容纳顶部恒温设备与照明，室内吊顶净高建议设定为 2.80m。",
      "感控要求与设施 / 温湿度控制：配置独立恒温恒湿空调系统，实时监控温湿度并自动调节；洗澡池水温控制在 38-40℃，配备智能水温计，防止烫伤。",
      "感控要求与设施 / 消毒设施配置：配备紫外线消毒灯、物体表面消毒机，每日对环境与设备消毒；洗澡池使用后即时清洁消毒，采用一次性消毒垫，避免交叉感染。",
      "感控要求与设施 / 手卫生与污物处理：洗手池采用双高度设计（0.6m/0.85m），配置感应水龙头与手消毒液；设置密闭分类垃圾桶，收集废弃消毒垫、湿巾等污物。",
      "室内装修与防护 / 墙地顶防水易洁：地面采用防滑等级≥R11 的防滑瓷砖，墙面满铺防水瓷砖（高度至顶）；墙角做圆弧处理，避免积水与积污。",
      "室内装修与防护 / 防撞与安全防护：洗澡池、抚触台边缘做圆角处理（R≥20mm），墙面 1.5m 以下采用软包防护；所有设备固定安装，防止倾倒。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "洗澡间使用面积",
        "requirement": "婴儿洗澡间使用面积不应小于 10.00㎡。",
        "source": "《儿童医院建设标准》建标 174-2016 专项要求",
        "suggestion": "考虑新生儿洗澡与家长学习护理需求，建议使用面积扩大至 12.00㎡至 14.00㎡，预留家长操作与休息空间。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "操作空间与间距",
        "requirement": "婴儿洗澡池之间净距不应小于 0.80m，洗澡池与墙面净距不应小于 0.60m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.3.6 条",
        "suggestion": "洗澡池之间净距≥1.0m，洗澡池与墙面净距≥0.8m，每个洗澡池周边预留≥1.2m 操作空间，满足医护与家长协同操作。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "室内净高控制",
        "requirement": "医疗用房室内净高不宜低于 2.60m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.1.9 条",
        "suggestion": "为保障通风与减少压抑感，同时容纳顶部恒温设备与照明，室内吊顶净高建议设定为 2.80m。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "温湿度控制",
        "requirement": "新生儿区域应保持恒温、恒湿环境，温度 24-26℃，湿度 50%-60%。",
        "source": "《儿童医院建设标准》建标 174-2016 第 33 条",
        "suggestion": "配置独立恒温恒湿空调系统，实时监控温湿度并自动调节；洗澡池水温控制在 38-40℃，配备智能水温计，防止烫伤。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "消毒设施配置",
        "requirement": "婴儿洗澡间应配备必要的消毒设施，对洗澡池、抚触台等进行消毒。",
        "source": "GB/T 39498-2020《医疗机构感染预防与控制基本准则》",
        "suggestion": "配备紫外线消毒灯、物体表面消毒机，每日对环境与设备消毒；洗澡池使用后即时清洁消毒，采用一次性消毒垫，避免交叉感染。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "手卫生与污物处理",
        "requirement": "操作区域应设置非接触式手卫生设施，污物分类收集。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 6.2.5 条",
        "suggestion": "洗手池采用双高度设计（0.6m/0.85m），配置感应水龙头与手消毒液；设置密闭分类垃圾桶，收集废弃消毒垫、湿巾等污物。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "墙地顶防水易洁",
        "requirement": "洗澡间地面、墙面应防水、防滑、易清洁，无卫生死角。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.1.10 条",
        "suggestion": "地面采用防滑等级≥R11 的防滑瓷砖，墙面满铺防水瓷砖（高度至顶）；墙角做圆弧处理，避免积水与积污。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "防撞与安全防护",
        "requirement": "儿童区域应采取防撞措施，避免尖锐棱角。",
        "source": "《儿童医院建设标准》建标 174-2016 第 37 条",
        "suggestion": "洗澡池、抚触台边缘做圆角处理（R≥20mm），墙面 1.5m 以下采用软包防护；所有设备固定安装，防止倾倒。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "声光环境控制",
        "requirement": "新生儿区域应保持安静，避免声光刺激。",
        "source": "《儿童医院建设标准》建标 174-2016 第 33 条",
        "suggestion": "室内采用柔光照明（照度 200-300lx），避免直射新生儿眼部；配置吸音材料，环境噪音控制在 40dB 以内，减少新生儿应激反应。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "家长观察与学习区",
        "requirement": "应设置家长观察与学习区域，便于医护指导家庭护理。",
        "source": "《儿童医院建设标准》建标 174-2016 第 38 条",
        "suggestion": "设独立家长观察区（≥2㎡），通过透明玻璃观察操作；配备座椅与讲解台，医护可现场指导家长洗澡、抚触、脐带护理等技能。"
      },
      {
        "dimension": "安全出口与疏散门",
        "focus": "门洞净宽与无障碍",
        "requirement": "房间门净宽不应小于 0.90m；疏散出口门不应设置门槛。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.1.4 条",
        "suggestion": "门洞净宽设计为 1.0m 单扇门，门下无门槛，便于婴儿车与急救设备通行；门体设观察窗，避免开门碰撞。"
      },
      {
        "dimension": "安全出口与疏散门",
        "focus": "应急设施配置",
        "requirement": "房间应配备应急照明与通讯设备，应对突发情况。",
        "source": "《建筑防火通用规范》GB 55037-2022 第 10.1.8 条",
        "suggestion": "配置应急照明（照度≥10.0lx），持续供电≥90min；设置应急呼叫按钮，与护士站联动，确保突发情况快速响应。"
      },
      {
        "dimension": "建筑防火",
        "focus": "材料燃烧性能",
        "requirement": "医疗建筑内部装修材料的燃烧性能等级不应低于 A 级，部分部位不应低于 B1 级。",
        "source": "《建筑防火通用规范》GB 55037-2022 第 6.1.1 条",
        "suggestion": "顶棚、墙面、地面采用 A 级不燃材料，软包防护采用 B1 级阻燃材料；所有装修材料无毒、无异味，符合新生儿环保要求。"
      },
      {
        "dimension": "建筑防火",
        "focus": "消防设施适配",
        "requirement": "消防设施应适应儿童区域特点，避免误触与遮挡。",
        "source": "《建筑防火通用规范》GB 55037-2022 第 6.5.1 条",
        "suggestion": "喷淋头、烟感探测器位置避开操作区域，消防栓采用隐蔽式设计并加防护盖；严禁用装饰材料遮挡消防设施与标识。"
      }
    ],
    "legacySiteModel": "models/model-real.html?space=toilet",
    "sceneInfo": {
      "area": "5.40 × 4.20 m 洗浴 + 暖台 + 洁污分离 · 净高 3.00m（≈22.7㎡）",
      "dims": {
        "def": [
          5.4,
          4.2,
          3
        ],
        "min": [
          5.2,
          3.8,
          2.8
        ],
        "sugg": [
          6,
          4.8,
          3.1
        ],
        "minLabel": "模型紧凑",
        "suggLabel": "双盆优化"
      },
      "markers": 6,
      "source": "2026.7.6 住院CAD/SKP + AusHFG住院/儿少/标准组件比对",
      "norms": [
        "规范底线：面积≥10㎡",
        "洗澡池间距≥0.80m",
        "池墙净距≥0.60m",
        "净高≥2.60m"
      ],
      "compliance": [
        "面积差值：模型示范约22.7㎡，规范底线≥10㎡，高出约12.7㎡。",
        "口径说明：规范底线用于审图合规判断，模型示范尺寸用于表达陪护、设备、活动和维护余量，不应写成规范最低值。"
      ]
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 57,
      "priority": "P3",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 59,
      "finalStatus": "已完成",
      "finalRequirement": "保留防滑示意，补水温和紧急状态。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "wd_child",
    "dept": "住院",
    "name": "儿童病房",
    "type": "ward",
    "priority": "P3",
    "summary": "三级儿童医院儿童单床病房模块，按最新2026.7.6住院SKP/DWG与规范复核；模型示范控制在规范底线以上，突出陪护床、学习活动、防撞、分类污物与床头呼叫。",
    "assets": [
      "docs/materials/2026.7.6/住院/CAD/住院病房重绘_t3.dwg",
      "docs/materials/2026.7.6/住院/模型/住院2.skp"
    ],
    "rules": [
      "nursing",
      "child",
      "gas"
    ],
    "siteModel": "models/viewer.html?scene=wd-child",
    "siteModelName": "3D交互信息模型（儿童病房 · 住院部）",
    "legacySiteModel": "models/model-real.html?space=ward",
    "sceneInfo": {
      "area": "5.40 × 4.60 m 儿童单床 + 陪护床 + 学习活动角 + 分类污物 · 净高 3.00m（≈24.8㎡）",
      "dims": {
        "def": [
          5.4,
          4.6,
          3
        ],
        "min": [
          5.2,
          4.4,
          2.8
        ],
        "sugg": [
          5.8,
          4.8,
          3.1
        ],
        "minLabel": "模型紧凑",
        "suggLabel": "儿童友好"
      },
      "markers": 8,
      "source": "2026.7.6/住院 最新SKP（住院2.skp）+ CAD（住院病房重绘_t3.dwg）+ 建标174-2016/GB51039复核",
      "norms": [
        "规范底线：单人病房≥18㎡",
        "病房净高≥2.60m",
        "需陪护空间",
        "需学习/活动空间"
      ],
      "compliance": [
        "面积差值：模型示范约24.8㎡，规范底线≥18㎡，高出约6.8㎡。",
        "差值来源：儿童陪护床、学习活动角、床头设备、分类污物和防撞界面；这些是三级儿童医院的示范余量，不是规范最低面积。"
      ]
    },
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "儿童病房按三级儿童医院住院模块复核：在GB 51039-2014单人病房底线基础上，叠加建标174-2016关于儿童学习活动、亲属陪护、分类污物和儿童防撞的要求；模型不再只是成人病房缩小版。",
    "docFacts": [
      "单床儿童病房：以单人病房18.00㎡底线为基础，按三级儿童医院陪护与儿童活动需求示范为约24.8㎡。",
      "陪护空间：病房应预留亲属陪护空间，宜设置陪护床或陪护椅；模型已改为可展开陪护床而非普通座椅。",
      "儿童学习活动：病房区域应配套设置儿童学习、活动空间；单床病房设置可看护学习活动角。",
      "儿童安全防护：儿童区域应采取防撞措施，模型增加1.2m以下防撞墙裙、低位软垫和圆角安全界面。",
      "分类污物：病房内医疗废物与生活垃圾分类收集，污物点靠近门口/卫生间回收短线。",
      "床头呼叫：病房应设呼叫信号系统，模型显式增加床头呼叫/应急照明面板并与护士站响应逻辑对应。",
      "最新素材：按2026.7.6/住院目录内住院2.skp与住院病房重绘_t3.dwg核对，发布系统副本哈希一致。"
    ],
    "docReview": [
      "空间模数 / 儿童单床病房面积：模型改为5.40×4.60m，保留床旁护理、陪护床和学习活动角，避免按成人单床病房压缩。",
      "儿童友好 / 学习活动空间：在病房左侧设置软垫学习活动角，放置低位绘本/玩具柜，并保持护士与家属可观察。",
      "陪护需求 / 亲属陪护位：将普通陪护沙发替换为可展开陪护床，位置避开床旁护理通道。",
      "感控与污物 / 分类污物收集：在门口/卫生间回收短线设置医疗/生活垃圾双分类带盖容器，不穿越儿童活动区。",
      "安全防护 / 防撞与圆角：增加1.2m以下防撞墙裙、活动区软垫和低位护栏，材料口径保持易清洁、耐消毒、阻燃。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数",
        "focus": "儿童单床病房面积",
        "requirement": "单人病房使用面积不应小于18.00㎡，儿童病房需叠加陪护与活动需求。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.3.2条；《儿童医院建设标准》建标174-2016 第35、36条",
        "suggestion": "模型改为5.40×4.60m，保留床旁护理、陪护床和学习活动角；规范底线18㎡另列，不把示范尺寸写成规范值。"
      },
      {
        "dimension": "儿童友好",
        "focus": "学习活动空间",
        "requirement": "病房区域应配套设置儿童学习、活动空间；多人病房应预留公共活动区域。",
        "source": "《儿童医院建设标准》建标174-2016 第35条",
        "suggestion": "在病房左侧设置软垫学习活动角，放置低位绘本/玩具柜，并保持护士与家属可观察。"
      },
      {
        "dimension": "陪护需求",
        "focus": "亲属陪护位",
        "requirement": "病房应预留亲属陪护空间，宜设置陪护床或陪护椅。",
        "source": "《儿童医院建设标准》建标174-2016 第36条",
        "suggestion": "将普通陪护沙发替换为可展开陪护床，位置避开床旁护理通道。"
      },
      {
        "dimension": "感控与污物",
        "focus": "分类污物收集",
        "requirement": "病房应设置独立污物收集容器，分类存放医疗废物与生活垃圾。",
        "source": "《儿童医院建设标准》建标174-2016 第47条",
        "suggestion": "在门口/卫生间回收短线设置医疗/生活垃圾双分类带盖容器，不穿越儿童活动区。"
      },
      {
        "dimension": "安全防护",
        "focus": "防撞与圆角",
        "requirement": "儿童区域应采取防撞措施，医疗用房墙地顶应便于清扫。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.1.12条；建标174-2016 儿童安全条目",
        "suggestion": "增加1.2m以下防撞墙裙、活动区软垫和低位护栏，材料口径保持易清洁、耐消毒、阻燃。"
      }
    ],
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 50,
      "priority": "P3",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 52,
      "finalStatus": "未修改到位",
      "finalRequirement": "活动区和玩具分离并远离入口；修正踢脚线穿门；陪护与卫生间门区不冲突。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "分离活动区与玩具，玩具柜移至东墙并校正方向，清除陪护位及门区冲突。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "wd_child_three",
    "dept": "住院",
    "name": "三人儿童病房",
    "type": "ward",
    "priority": "P1",
    "summary": "三级儿童医院三人儿童病房模块，按最新2026.7.6住院SKP/DWG与规范复核；模型示范高于多床病房底线，重点表达床间护理净距、公共活动区、陪护收纳、防撞与分类污物。",
    "assets": [
      "docs/materials/2026.7.6/住院/CAD/住院病房重绘_t3.dwg",
      "docs/materials/2026.7.6/住院/模型/住院2.skp"
    ],
    "rules": [
      "nursing",
      "child",
      "gas",
      "accessible"
    ],
    "siteModel": "models/viewer.html?scene=wd-child-three",
    "siteModelName": "3D交互信息模型（三人儿童病房 · 住院部）",
    "glbModel": "glb/iw-triple-child-ward.glb",
    "legacySiteModel": "models/model-real.html?space=ward",
    "sceneInfo": {
      "area": "7.80 × 5.40 m 三床儿童病房 + 公共活动区 + 陪护储物 · 净高 3.00m（≈42.1㎡）",
      "dims": {
        "def": [
          7.8,
          5.4,
          3
        ],
        "min": [
          7.4,
          5.2,
          2.8
        ],
        "sugg": [
          8.4,
          6,
          3.1
        ],
        "minLabel": "模型紧凑",
        "suggLabel": "护理优化"
      },
      "markers": 8,
      "source": "2026.7.6/住院 最新SKP（住院2.skp）+ CAD（住院病房重绘_t3.dwg）+ 建标174-2016/GB51039复核",
      "norms": [
        "规范参照：多床病房≥32㎡",
        "床间净距≥1.20m",
        "需公共活动区",
        "病房净高≥2.60m"
      ],
      "compliance": [
        "面积差值：模型示范约42.1㎡，规范参照底线≥32㎡，高出约10.1㎡。",
        "差值来源：三床床间护理净距、公共活动区、陪护储物和儿童安全界面；用于示范，不作为规范最低值。"
      ]
    },
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "三人儿童病房按多床儿童病房复核：使用面积高于四人病房32㎡底线，设置床间护理净距、公共活动软垫区、陪护储物、分类污物和床头呼叫，避免多床房只剩床位堆叠。",
    "docFacts": [
      "多床病房面积：综合医院标准中四人病房使用面积不应小于32.0㎡；三人儿童病房模型调整为约42.1㎡，预留陪护与公共活动空间。",
      "床间净距：病床净间距不应小于1.2m，儿童病房建议按1.5m及以上控制，便于医护与家属同时通行。",
      "公共活动区域：多人病房应预留公共活动区域，模型加入软垫活动区和低位绘本/玩具柜。",
      "儿童安全防护：活动区增加软垫、低位护栏和防撞墙裙，避开床旁护理线。",
      "分类污物与呼叫：病房内设置双分类污物容器，床头设置呼叫/应急面板。",
      "最新素材：按2026.7.6/住院目录内住院2.skp与住院病房重绘_t3.dwg核对，发布系统副本哈希一致。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数",
        "focus": "三人儿童病房面积",
        "requirement": "多床病房需满足病床净距与儿童陪护活动需求。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.3.2条；《儿童医院建设标准》建标174-2016 第35条",
        "suggestion": "模型改为7.80×5.40m，床位之外保留公共活动软垫区与陪护储物；规范参照底线另列，不把示范尺寸写成规范值。"
      },
      {
        "dimension": "护理净距",
        "focus": "床间与床尾通道",
        "requirement": "病床净间距不应小于1.20m，病床端部与墙面需保留护理通行。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第5.3.2条",
        "suggestion": "三床沿床头设备带布置，中央护理通道连续，床尾不被陪护床和玩具柜截断。"
      },
      {
        "dimension": "儿童友好",
        "focus": "多人病房公共活动区",
        "requirement": "多人病房应预留公共活动区域，满足儿童互动需求。",
        "source": "《儿童医院建设标准》建标174-2016 第35条",
        "suggestion": "在病房侧向设置约2.05×1.48m活动软垫区，并以低位护栏和固定玩具柜限定边界。"
      },
      {
        "dimension": "感控与污物",
        "focus": "分类污物收集",
        "requirement": "病房应设置分类污物收集容器，集中存放医疗废物与生活垃圾。",
        "source": "《儿童医院建设标准》建标174-2016 第47条",
        "suggestion": "污物点靠近回收短线，避免穿越公共活动区。"
      },
      {
        "dimension": "弱电应急",
        "focus": "床头呼叫系统",
        "requirement": "门诊、急诊、病房等应设呼叫信号系统。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第9.3.1条",
        "suggestion": "每床床头增加呼叫/应急照明面板，与护士站观察逻辑一致。"
      }
    ],
    "docReview": [
      "空间模数 / 三人儿童病房面积：模型改为7.80×5.40m，床位之外保留公共活动软垫区与陪护储物。",
      "护理净距 / 床间与床尾通道：三床沿床头设备带布置，中央护理通道连续，床尾不被陪护床和玩具柜截断。",
      "儿童友好 / 多人病房公共活动区：在病房侧向设置约2.05×1.48m活动软垫区，并以低位护栏和固定玩具柜限定边界。",
      "感控与污物 / 分类污物收集：污物点靠近回收短线，避免穿越公共活动区。",
      "弱电应急 / 床头呼叫系统：每床床头增加呼叫/应急照明面板，与护士站观察逻辑一致。"
    ],
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 51,
      "priority": "P1",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 53,
      "finalStatus": "部分完成",
      "finalRequirement": "逐床绑定陪护；活动区与玩具分离。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）",
    "glbModelDisabled": true,
    "glbModelDisabledReason": "2026-07-13 GLB 包围核查发现尺度、原点或游离构件异常；程序场景保留，清理并统一米制重导前禁用实景切换。",
    "glbAuditStatus": "隔离待重导"
  },
  {
    "id": "wd_dirty_laundry",
    "dept": "住院",
    "name": "污物洗涤室",
    "type": "clinic",
    "priority": "P3",
    "summary": "污物洗涤室审图重点包括洗涤室使用面积、操作间距与通道、室内净高控制等内容；依据《综合医院建筑设计标准》GB 51039-2014 第 5.3.5 条；《综合医院建筑设计标准》GB 51039-2014 第 5.1.9 条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/住院/CAD/住院病房重绘_t3.dwg"
    ],
    "rules": [
      "area",
      "privacy",
      "child",
      "infection"
    ],
    "siteModel": "models/viewer.html?scene=wd-dirty-laundry",
    "siteModelName": "3D交互信息模型（污物洗涤室 · 住院部）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "污物洗涤室审图重点包括洗涤室使用面积、操作间距与通道、室内净高控制等内容；依据《综合医院建筑设计标准》GB 51039-2014 第 5.3.5 条；《综合医院建筑设计标准》GB 51039-2014 第 5.1.9 条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "洗涤室使用面积：污物洗涤室使用面积不应小于 12.00㎡。",
      "操作间距与通道：洗涤池之间净距不应小于 0.80m，室内主通道净宽不应小于 1.20m。",
      "室内净高控制：医疗用房室内净高不宜低于 2.60m。",
      "洁污分区隔离：污物洗涤室应与清洁区域严格物理隔离，流线不交叉。",
      "消毒设施配置：应配备必要的消毒设施，对污物与洗涤设备进行消毒。",
      "通风与防异味：污物洗涤室应具备良好的通风条件，防止异味溢出。"
    ],
    "docReview": [
      "空间模数与净空 / 洗涤室使用面积：考虑儿童住院污物量与分类洗涤需求，建议使用面积扩大至 15.00㎡至 18.00㎡，分设洗涤区、消毒区、暂存区。",
      "空间模数与净空 / 操作间距与通道：洗涤池之间净距≥1.0m，主通道净宽≥1.5m，预留清洁车通行与回转空间（≥1.2m×1.2m）。",
      "空间模数与净空 / 室内净高控制：为容纳洗涤设备、通风管道与储物架，室内吊顶净高建议设定为 2.80m。",
      "感控要求与设施 / 洁污分区隔离：洗涤室设独立出入口，与护理单元清洁通道无交叉；内部划分洗涤区、消毒区、暂存区，设置明显标识，流线单向不可逆。",
      "感控要求与设施 / 消毒设施配置：配备高温高压消毒锅、含氯消毒剂配比器、紫外线消毒灯；洗涤池配备热水供应系统（水温≥80℃），满足污物消毒洗涤要求。",
      "感控要求与设施 / 通风与防异味：配置独立机械排风系统，排风次数≥12 次 / 小时，排风口远离清洁区域与室外活动场所；室内设置防臭地漏与密封式排水管道，避免异味回流。",
      "室内装修与防护 / 墙地顶防水耐污：地面采用防滑耐腐的陶瓷地砖（防滑等级≥R10），墙面满铺防水瓷砖（高度至顶）；墙角做圆弧处理，无卫生死角，支持高压水枪冲洗。",
      "室内装修与防护 / 洗涤设备适配：配置 3 个专用洗涤池（分别用于感染性、损伤性、生活垃圾容器洗涤），池体采用耐腐材质，带防溅挡板；配备污物分类存放架，离地≥15cm。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "洗涤室使用面积",
        "requirement": "污物洗涤室使用面积不应小于 12.00㎡。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.3.5 条",
        "suggestion": "考虑儿童住院污物量与分类洗涤需求，建议使用面积扩大至 15.00㎡至 18.00㎡，分设洗涤区、消毒区、暂存区。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "操作间距与通道",
        "requirement": "洗涤池之间净距不应小于 0.80m，室内主通道净宽不应小于 1.20m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.3.5 条",
        "suggestion": "洗涤池之间净距≥1.0m，主通道净宽≥1.5m，预留清洁车通行与回转空间（≥1.2m×1.2m）。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "室内净高控制",
        "requirement": "医疗用房室内净高不宜低于 2.60m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.1.9 条",
        "suggestion": "为容纳洗涤设备、通风管道与储物架，室内吊顶净高建议设定为 2.80m。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "洁污分区隔离",
        "requirement": "污物洗涤室应与清洁区域严格物理隔离，流线不交叉。",
        "source": "GB/T 39498-2020《医疗机构感染预防与控制基本准则》",
        "suggestion": "洗涤室设独立出入口，与护理单元清洁通道无交叉；内部划分洗涤区、消毒区、暂存区，设置明显标识，流线单向不可逆。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "消毒设施配置",
        "requirement": "应配备必要的消毒设施，对污物与洗涤设备进行消毒。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.3.5 条",
        "suggestion": "配备高温高压消毒锅、含氯消毒剂配比器、紫外线消毒灯；洗涤池配备热水供应系统（水温≥80℃），满足污物消毒洗涤要求。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "通风与防异味",
        "requirement": "污物洗涤室应具备良好的通风条件，防止异味溢出。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 7.1.1 条",
        "suggestion": "配置独立机械排风系统，排风次数≥12 次 / 小时，排风口远离清洁区域与室外活动场所；室内设置防臭地漏与密封式排水管道，避免异味回流。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "墙地顶防水耐污",
        "requirement": "地面、墙面应防水、防污、易清洁，耐腐蚀。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.1.10 条",
        "suggestion": "地面采用防滑耐腐的陶瓷地砖（防滑等级≥R10），墙面满铺防水瓷砖（高度至顶）；墙角做圆弧处理，无卫生死角，支持高压水枪冲洗。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "洗涤设备适配",
        "requirement": "应配置专用洗涤设备，满足不同污物洗涤需求。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.3.5 条",
        "suggestion": "配置 3 个专用洗涤池（分别用于感染性、损伤性、生活垃圾容器洗涤），池体采用耐腐材质，带防溅挡板；配备污物分类存放架，离地≥15cm。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "安全防护设施",
        "requirement": "应采取必要的安全防护措施，避免人员受伤。",
        "source": "《综合医院建设标准》建标 110-2021 第三十九条",
        "suggestion": "墙面设置耐腐蚀防撞板，洗涤池边缘做圆角处理；配备防割手套、防护口罩、护目镜等防护用品，存放于易取用位置。"
      },
      {
        "dimension": "安全出口与疏散门",
        "focus": "门洞净宽与密封",
        "requirement": "房间门净宽不应小于 0.90m；门应具备密封功能，防止异味溢出。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.1.4 条",
        "suggestion": "房间门采用密闭式单扇门，净宽≥1.0m，配备闭门器与密封条，防止异味溢出；门下设置防鼠挡板，高度≥20cm。"
      },
      {
        "dimension": "安全出口与疏散门",
        "focus": "疏散路径畅通",
        "requirement": "房间内疏散路径无障碍物，便于紧急情况下快速撤离。",
        "source": "《建筑防火通用规范》GB 55037-2022 第 7.1.4 条",
        "suggestion": "洗涤设备、储物架布置不遮挡疏散通道，通道净宽≥1.2m；紧急情况下可快速清空暂存区，确保疏散顺畅。"
      },
      {
        "dimension": "建筑防火",
        "focus": "材料燃烧性能",
        "requirement": "医疗建筑内部装修材料的燃烧性能等级不应低于 A 级。",
        "source": "《建筑防火通用规范》GB 55037-2022 第 6.1.1 条",
        "suggestion": "顶棚、墙面、地面全部采用 A 级不燃材料，严禁使用易燃、易腐装饰材料；洗涤设备、储物架采用阻燃、耐腐蚀材质。"
      },
      {
        "dimension": "建筑防火",
        "focus": "消防设施配置",
        "requirement": "房间应按规范配置消防设施，避免腐蚀与遮挡。",
        "source": "《建筑防火通用规范》GB 55037-2022 第 6.5.1 条",
        "suggestion": "房间内配置耐腐蚀灭火器，位置醒目且便于取用；烟感探测器、喷淋头做防腐蚀处理，无遮挡，确保感应灵敏。"
      }
    ],
    "legacySiteModel": "models/model-real.html?space=clinic",
    "sceneInfo": {
      "area": "5.40 × 4.80 m 污物暂存 + 洗涤消毒 + 负压排风 · 净高 3.00m（≈25.9㎡）",
      "dims": {
        "def": [
          5.4,
          4.8,
          3
        ],
        "min": [
          4.8,
          4.2,
          2.8
        ],
        "sugg": [
          6,
          5.4,
          3.1
        ],
        "minLabel": "模型紧凑",
        "suggLabel": "分区优化"
      },
      "markers": 6,
      "source": "2026.7.6 住院CAD/SKP + AusHFG住院/儿少/标准组件比对",
      "norms": [
        "规范底线：面积≥12㎡",
        "洗涤池间距≥0.80m",
        "主通道≥1.20m",
        "净高≥2.60m"
      ],
      "compliance": [
        "面积差值：模型示范约25.9㎡，规范底线≥12㎡，高出约13.9㎡。",
        "口径说明：规范底线用于审图合规判断，模型示范尺寸用于表达陪护、设备、活动和维护余量，不应写成规范最低值。"
      ]
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 56,
      "priority": "P3",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 58,
      "finalStatus": "已完成",
      "finalRequirement": "保留现状并补充厂家检修净距校核。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "wd_double",
    "dept": "住院",
    "name": "双人病房",
    "type": "ward",
    "priority": "P1",
    "summary": "双人病房审图重点包括病房使用面积、病床间距与操作空间、室内净高控制等内容；依据《综合医院建筑设计标准》GB 51039-2014 第 5.3.2 条；《综合医院建筑设计标准》GB 51039-2014 第 5.1.9 条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/住院/CAD/住院病房重绘_t3.dwg",
      "docs/materials/住院/双人病房_2.mp4",
      "docs/materials/住院/双人病房_03.mp4"
    ],
    "video": "docs/materials/住院/双人病房_2.mp4",
    "rules": [
      "area",
      "handwash",
      "privacy",
      "child"
    ],
    "siteModel": "models/viewer.html?scene=wd-double",
    "siteModelName": "3D交互信息模型（双人病房 · 住院部）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "双人病房审图重点包括病房使用面积、病床间距与操作空间、室内净高控制等内容；依据《综合医院建筑设计标准》GB 51039-2014 第 5.3.2 条；《综合医院建筑设计标准》GB 51039-2014 第 5.1.9 条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "病房使用面积：双人病房使用面积不应小于 24.00㎡。",
      "病床间距与操作空间：病床净间距不应小于 1.20m，病床与墙面净距不应小于 0.60m。",
      "室内净高控制：病房室内净高不宜低于 2.60m。",
      "手卫生设施配置：病房应设置非接触式手卫生设施，满足感控要求。",
      "通风与消毒条件：病房应具备良好的通风条件，墙面、地面应便于清洁消毒。",
      "污物收集设施：病房应设置独立的污物收集容器，分类存放医疗废物与生活垃圾。"
    ],
    "docReview": [
      "空间模数与净空 / 病房使用面积：考虑儿童陪护与设备摆放需求，建议使用面积扩大至 26.00㎡至 28.00㎡，提升居住舒适度。",
      "空间模数与净空 / 病床间距与操作空间：病床净间距≥1.50m，病床与墙面净距≥0.80m，每张病床周边预留≥0.9m 操作通道，满足医护护理与家长陪护。",
      "空间模数与净空 / 室内净高控制：为容纳医疗设备带、隔帘轨道及改善空间压抑感，室内吊顶净高建议设定为 2.80m。",
      "感控要求与设施 / 手卫生设施配置：病房卫生间内配置感应水龙头与手消毒液分配器，病床旁增设移动手消液架，实现 “床旁手卫生” 便捷化。",
      "感控要求与设施 / 通风与消毒条件：采用自然通风与机械通风结合，换气次数≥6 次 / 小时；地面、墙面采用耐消毒材料，无卫生死角，支持高频次消杀。",
      "感控要求与设施 / 污物收集设施：病房内设置双分类密闭垃圾桶（医疗废物、生活垃圾），带盖设计，位置隐蔽且便于取用；卫生间设专用污水排放口，防异味溢出。",
      "室内装修与防护 / 墙地顶易洁与防撞：地面采用同质透心抗菌 PVC 卷材，上卷上墙 15cm；墙面 1.2m 以下设防撞墙裙，所有阳角执行 R≥20mm 圆角工艺，避免磕碰。",
      "室内装修与防护 / 家具安全与固定：病床、储物柜、陪护椅等全部固定安装，无尖锐边角；儿童病床带可调节护栏，床高适配护理操作（0.6-0.7m）。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "病房使用面积",
        "requirement": "双人病房使用面积不应小于 24.00㎡。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.3.2 条",
        "suggestion": "考虑儿童陪护与设备摆放需求，建议使用面积扩大至 26.00㎡至 28.00㎡，提升居住舒适度。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "病床间距与操作空间",
        "requirement": "病床净间距不应小于 1.20m，病床与墙面净距不应小于 0.60m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.3.2 条",
        "suggestion": "病床净间距≥1.50m，病床与墙面净距≥0.80m，每张病床周边预留≥0.9m 操作通道，满足医护护理与家长陪护。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "室内净高控制",
        "requirement": "病房室内净高不宜低于 2.60m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.1.9 条",
        "suggestion": "为容纳医疗设备带、隔帘轨道及改善空间压抑感，室内吊顶净高建议设定为 2.80m。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "手卫生设施配置",
        "requirement": "病房应设置非接触式手卫生设施，满足感控要求。",
        "source": "GB/T 39498-2020《医疗机构感染预防与控制基本准则》",
        "suggestion": "病房卫生间内配置感应水龙头与手消毒液分配器，病床旁增设移动手消液架，实现 “床旁手卫生” 便捷化。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "通风与消毒条件",
        "requirement": "病房应具备良好的通风条件，墙面、地面应便于清洁消毒。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.3.2 条、第 5.1.10 条",
        "suggestion": "采用自然通风与机械通风结合，换气次数≥6 次 / 小时；地面、墙面采用耐消毒材料，无卫生死角，支持高频次消杀。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "污物收集设施",
        "requirement": "病房应设置独立的污物收集容器，分类存放医疗废物与生活垃圾。",
        "source": "《儿童医院建设标准》建标 174-2016 第 47 条",
        "suggestion": "病房内设置双分类密闭垃圾桶（医疗废物、生活垃圾），带盖设计，位置隐蔽且便于取用；卫生间设专用污水排放口，防异味溢出。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "墙地顶易洁与防撞",
        "requirement": "医疗用房的地面、墙面、顶棚应便于清扫；儿童区域应采取防撞措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.1.12 条",
        "suggestion": "地面采用同质透心抗菌 PVC 卷材，上卷上墙 15cm；墙面 1.2m 以下设防撞墙裙，所有阳角执行 R≥20mm 圆角工艺，避免磕碰。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "家具安全与固定",
        "requirement": "儿童诊疗区域的家具应采取固定措施，防止倾倒伤人。",
        "source": "《综合医院建设标准》建标 110-2021 第三十九条",
        "suggestion": "病床、储物柜、陪护椅等全部固定安装，无尖锐边角；儿童病床带可调节护栏，床高适配护理操作（0.6-0.7m）。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "声光环境控制",
        "requirement": "医院建筑应注重改善患者的就医环境，减少噪音干扰。",
        "source": "《综合医院建设标准》建标 110-2021 第五条",
        "suggestion": "墙面、顶棚采用吸音材料，降低环境噪音（控制在 45dB 以内）；照明采用柔光设计，避免眩光，配置床头独立照明开关。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "陪护空间适配",
        "requirement": "病房应预留亲属陪护空间，宜设置陪护床或陪护椅。",
        "source": "《儿童医院建设标准》建标 174-2016 第 36 条",
        "suggestion": "每床配置可折叠陪护椅（夜间展开尺寸≥1.8m×0.6m），病房角落预留陪护休息区域，避免占用通道空间。"
      },
      {
        "dimension": "安全出口与疏散门",
        "focus": "门洞净宽与无障碍",
        "requirement": "病房门净宽不应小于 0.90m；疏散出口门不应设置门槛。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.1.4 条、《建筑防火通用规范》GB 55037-2022 第 7.2.1 条",
        "suggestion": "病房门采用子母门，净宽≥1.0m，门下无门槛，便于轮椅、平车通行；门体设观察窗，避免开门碰撞。"
      },
      {
        "dimension": "安全出口与疏散门",
        "focus": "隐私与隔断保护",
        "requirement": "病房床间应设置隔帘或屏风，保障患者隐私。",
        "source": "《综合医院建设标准》建标 110-2021 第三十九条",
        "suggestion": "床间设置可移动隔断帘，轨道覆盖全床范围；病房门开启方向避免走廊直视病床，保护诊疗与休息隐私。"
      },
      {
        "dimension": "建筑防火",
        "focus": "材料燃烧性能",
        "requirement": "医疗建筑内部装修材料的燃烧性能等级不应低于 A 级，部分部位不应低于 B1 级。",
        "source": "《建筑防火通用规范》GB 55037-2022 第 6.1.1 条",
        "suggestion": "顶棚、墙面、地面采用 A 级不燃材料，陪护椅、窗帘等软装选用 B1 级阻燃材料；严禁使用易燃、易挥发有害物质的装修材料。"
      },
      {
        "dimension": "建筑防火",
        "focus": "消防设施配置",
        "requirement": "病房应按规范配置消防设施，避免遮挡与误触。",
        "source": "《建筑防火通用规范》GB 55037-2022 第 6.5.1 条",
        "suggestion": "病房内配置灭火器，位置醒目且便于取用；烟感探测器、喷淋头避开家具与设备遮挡，与医疗设备带保持安全距离。"
      }
    ],
    "glbModel": "glb/iw-double-ward.glb",
    "legacySiteModel": "models/model-real.html?space=ward",
    "sceneInfo": {
      "area": "6.60 × 4.80 m 双床病房 + 陪护 + 床头设备 · 净高 3.00m（≈31.7㎡）",
      "dims": {
        "def": [
          6.6,
          4.8,
          3
        ],
        "min": [
          6,
          4.2,
          2.8
        ],
        "sugg": [
          7.2,
          5.4,
          3.1
        ],
        "minLabel": "紧凑双床",
        "suggLabel": "护理优化"
      },
      "markers": 6,
      "source": "2026.7.6 住院CAD/SKP + AusHFG住院/儿少/标准组件比对",
      "norms": [
        "规范底线：双人病房≥24㎡",
        "床间净距≥1.20m",
        "床墙净距≥0.60m",
        "净高≥2.60m"
      ],
      "compliance": [
        "面积差值：模型示范约31.7㎡，规范底线≥24㎡，高出约7.7㎡。",
        "口径说明：规范底线用于审图合规判断，模型示范尺寸用于表达陪护、设备、活动和维护余量，不应写成规范最低值。"
      ]
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 52,
      "priority": "P1",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 54,
      "finalStatus": "已完成",
      "finalRequirement": "保留两名陪护动态与担架通行状态。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）",
    "glbModelDisabled": true,
    "glbModelDisabledReason": "2026-07-13 GLB 包围核查发现尺度、原点或游离构件异常；程序场景保留，清理并统一米制重导前禁用实景切换。",
    "glbAuditStatus": "隔离待重导"
  },
  {
    "id": "wd_double_alt",
    "dept": "住院",
    "name": "双人病房（方案比较）",
    "type": "ward",
    "priority": "P3",
    "summary": "双人病房（方案比较）审图重点包括病房使用面积、病床间距与操作空间、室内净高控制等内容；依据《综合医院建筑设计标准》GB 51039-2014 第 5.3.2 条；《综合医院建筑设计标准》GB 51039-2014 第 5.1.9 条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/住院/CAD/住院病房重绘_t3.dwg",
      "docs/materials/住院/双人病房.mp4",
      "docs/materials/住院/双人病房_2.mp4"
    ],
    "video": "docs/materials/住院/双人病房.mp4",
    "rules": [
      "nursing",
      "gas",
      "child"
    ],
    "siteModel": "models/viewer.html?scene=wd-double-alt",
    "siteModelName": "3D交互信息模型（双人病房（方案比较） · 住院部）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "病房使用面积",
        "requirement": "双人病房使用面积不应小于 24.00㎡。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.3.2 条",
        "suggestion": "考虑儿童陪护与设备摆放需求，建议使用面积扩大至 26.00㎡至 28.00㎡，提升居住舒适度。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "病床间距与操作空间",
        "requirement": "病床净间距不应小于 1.20m，病床与墙面净距不应小于 0.60m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.3.2 条",
        "suggestion": "病床净间距≥1.50m，病床与墙面净距≥0.80m，每张病床周边预留≥0.9m 操作通道，满足医护护理与家长陪护。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "室内净高控制",
        "requirement": "病房室内净高不宜低于 2.60m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.1.9 条",
        "suggestion": "为容纳医疗设备带、隔帘轨道及改善空间压抑感，室内吊顶净高建议设定为 2.80m。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "手卫生设施配置",
        "requirement": "病房应设置非接触式手卫生设施，满足感控要求。",
        "source": "GB/T 39498-2020《医疗机构感染预防与控制基本准则》",
        "suggestion": "病房卫生间内配置感应水龙头与手消毒液分配器，病床旁增设移动手消液架，实现 “床旁手卫生” 便捷化。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "通风与消毒条件",
        "requirement": "病房应具备良好的通风条件，墙面、地面应便于清洁消毒。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.3.2 条、第 5.1.10 条",
        "suggestion": "采用自然通风与机械通风结合，换气次数≥6 次 / 小时；地面、墙面采用耐消毒材料，无卫生死角，支持高频次消杀。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "污物收集设施",
        "requirement": "病房应设置独立的污物收集容器，分类存放医疗废物与生活垃圾。",
        "source": "《儿童医院建设标准》建标 174-2016 第 47 条",
        "suggestion": "病房内设置双分类密闭垃圾桶（医疗废物、生活垃圾），带盖设计，位置隐蔽且便于取用；卫生间设专用污水排放口，防异味溢出。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "墙地顶易洁与防撞",
        "requirement": "医疗用房的地面、墙面、顶棚应便于清扫；儿童区域应采取防撞措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.1.12 条",
        "suggestion": "地面采用同质透心抗菌 PVC 卷材，上卷上墙 15cm；墙面 1.2m 以下设防撞墙裙，所有阳角执行 R≥20mm 圆角工艺，避免磕碰。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "家具安全与固定",
        "requirement": "儿童诊疗区域的家具应采取固定措施，防止倾倒伤人。",
        "source": "《综合医院建设标准》建标 110-2021 第三十九条",
        "suggestion": "病床、储物柜、陪护椅等全部固定安装，无尖锐边角；儿童病床带可调节护栏，床高适配护理操作（0.6-0.7m）。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "声光环境控制",
        "requirement": "医院建筑应注重改善患者的就医环境，减少噪音干扰。",
        "source": "《综合医院建设标准》建标 110-2021 第五条",
        "suggestion": "墙面、顶棚采用吸音材料，降低环境噪音（控制在 45dB 以内）；照明采用柔光设计，避免眩光，配置床头独立照明开关。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "陪护空间适配",
        "requirement": "病房应预留亲属陪护空间，宜设置陪护床或陪护椅。",
        "source": "《儿童医院建设标准》建标 174-2016 第 36 条",
        "suggestion": "每床配置可折叠陪护椅（夜间展开尺寸≥1.8m×0.6m），病房角落预留陪护休息区域，避免占用通道空间。"
      },
      {
        "dimension": "安全出口与疏散门",
        "focus": "门洞净宽与无障碍",
        "requirement": "病房门净宽不应小于 0.90m；疏散出口门不应设置门槛。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.1.4 条、《建筑防火通用规范》GB 55037-2022 第 7.2.1 条",
        "suggestion": "病房门采用子母门，净宽≥1.0m，门下无门槛，便于轮椅、平车通行；门体设观察窗，避免开门碰撞。"
      },
      {
        "dimension": "安全出口与疏散门",
        "focus": "隐私与隔断保护",
        "requirement": "病房床间应设置隔帘或屏风，保障患者隐私。",
        "source": "《综合医院建设标准》建标 110-2021 第三十九条",
        "suggestion": "床间设置可移动隔断帘，轨道覆盖全床范围；病房门开启方向避免走廊直视病床，保护诊疗与休息隐私。"
      },
      {
        "dimension": "建筑防火",
        "focus": "材料燃烧性能",
        "requirement": "医疗建筑内部装修材料的燃烧性能等级不应低于 A 级，部分部位不应低于 B1 级。",
        "source": "《建筑防火通用规范》GB 55037-2022 第 6.1.1 条",
        "suggestion": "顶棚、墙面、地面采用 A 级不燃材料，陪护椅、窗帘等软装选用 B1 级阻燃材料；严禁使用易燃、易挥发有害物质的装修材料。"
      },
      {
        "dimension": "建筑防火",
        "focus": "消防设施配置",
        "requirement": "病房应按规范配置消防设施，避免遮挡与误触。",
        "source": "《建筑防火通用规范》GB 55037-2022 第 6.5.1 条",
        "suggestion": "病房内配置灭火器，位置醒目且便于取用；烟感探测器、喷淋头避开家具与设备遮挡，与医疗设备带保持安全距离。"
      }
    ],
    "docFacts": [
      "病房使用面积：双人病房使用面积不应小于 24.00㎡。",
      "病床间距与操作空间：病床净间距不应小于 1.20m，病床与墙面净距不应小于 0.60m。",
      "室内净高控制：病房室内净高不宜低于 2.60m。",
      "手卫生设施配置：病房应设置非接触式手卫生设施，满足感控要求。",
      "通风与消毒条件：病房应具备良好的通风条件，墙面、地面应便于清洁消毒。",
      "污物收集设施：病房应设置独立的污物收集容器，分类存放医疗废物与生活垃圾。"
    ],
    "docReview": [
      "空间模数与净空 / 病房使用面积：考虑儿童陪护与设备摆放需求，建议使用面积扩大至 26.00㎡至 28.00㎡，提升居住舒适度。",
      "空间模数与净空 / 病床间距与操作空间：病床净间距≥1.50m，病床与墙面净距≥0.80m，每张病床周边预留≥0.9m 操作通道，满足医护护理与家长陪护。",
      "空间模数与净空 / 室内净高控制：为容纳医疗设备带、隔帘轨道及改善空间压抑感，室内吊顶净高建议设定为 2.80m。",
      "感控要求与设施 / 手卫生设施配置：病房卫生间内配置感应水龙头与手消毒液分配器，病床旁增设移动手消液架，实现 “床旁手卫生” 便捷化。",
      "感控要求与设施 / 通风与消毒条件：采用自然通风与机械通风结合，换气次数≥6 次 / 小时；地面、墙面采用耐消毒材料，无卫生死角，支持高频次消杀。",
      "感控要求与设施 / 污物收集设施：病房内设置双分类密闭垃圾桶（医疗废物、生活垃圾），带盖设计，位置隐蔽且便于取用；卫生间设专用污水排放口，防异味溢出。",
      "室内装修与防护 / 墙地顶易洁与防撞：地面采用同质透心抗菌 PVC 卷材，上卷上墙 15cm；墙面 1.2m 以下设防撞墙裙，所有阳角执行 R≥20mm 圆角工艺，避免磕碰。",
      "室内装修与防护 / 家具安全与固定：病床、储物柜、陪护椅等全部固定安装，无尖锐边角；儿童病床带可调节护栏，床高适配护理操作（0.6-0.7m）。"
    ],
    "docBrief": "双人病房（方案比较）审图重点包括病房使用面积、病床间距与操作空间、室内净高控制等内容；依据《综合医院建筑设计标准》GB 51039-2014 第 5.3.2 条；《综合医院建筑设计标准》GB 51039-2014 第 5.1.9 条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "legacySiteModel": "models/model-real.html?space=ward",
    "sceneInfo": {
      "area": "6.60 × 4.80 m 双床病房对比方案 · 净高 3.00m（≈31.7㎡）",
      "dims": {
        "def": [
          6.6,
          4.8,
          3
        ],
        "min": [
          6,
          4.2,
          2.8
        ],
        "sugg": [
          7.2,
          5.4,
          3.1
        ],
        "minLabel": "紧凑双床",
        "suggLabel": "对比优化"
      },
      "markers": 5,
      "source": "2026.7.6 住院CAD/SKP + AusHFG住院/儿少/标准组件比对",
      "norms": [
        "规范底线：双人病房≥24㎡",
        "床间净距≥1.20m",
        "床墙净距≥0.60m",
        "净高≥2.60m"
      ],
      "compliance": [
        "面积差值：模型示范约31.7㎡，规范底线≥24㎡，高出约7.7㎡。",
        "口径说明：规范底线用于审图合规判断，模型示范尺寸用于表达陪护、设备、活动和维护余量，不应写成规范最低值。"
      ]
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 53,
      "priority": "P3",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 55,
      "finalStatus": "部分完成",
      "finalRequirement": "隐私设施退出通道；页面明确对比量测指标。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "wd_four",
    "dept": "住院",
    "name": "四人病房",
    "type": "ward",
    "priority": "P1",
    "summary": "四人病房审图重点包括病房使用面积、病床间距与通道、室内净高控制等内容；依据《综合医院建筑设计标准》GB 51039-2014；GB/T 39498-2020《医疗机构感染预防与控制基本准则》复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/住院/CAD/住院病房重绘_t3.dwg"
    ],
    "rules": [
      "area",
      "handwash",
      "privacy",
      "child"
    ],
    "siteModel": "models/viewer.html?scene=wd-four",
    "siteModelName": "3D交互信息模型（四人病房 · 住院部）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "四人病房审图重点包括病房使用面积、病床间距与通道、室内净高控制等内容；依据《综合医院建筑设计标准》GB 51039-2014；GB/T 39498-2020《医疗机构感染预防与控制基本准则》复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "病房使用面积：四人病房使用面积不应小于 32.00㎡。",
      "病床间距与通道：病床净间距不应小于 1.20m，病房内主通道净宽不应小于 1.40m。",
      "室内净高控制：病房室内净高不宜低于 2.60m。",
      "手卫生设施配置：病房应设置足够的非接触式手卫生设施，满足感控要求。",
      "通风与消毒条件：病房应具备良好的通风条件，墙面、地面应便于清洁消毒。",
      "污物收集设施：病房应设置分类污物收集容器，集中存放医疗废物与生活垃圾。"
    ],
    "docReview": [
      "空间模数与净空 / 病房使用面积：考虑儿童陪护与群体康复需求，建议使用面积扩大至 35.00㎡至 38.00㎡，预留公共活动与设备摆放空间。",
      "空间模数与净空 / 病床间距与通道：病床净间距≥1.50m，主通道净宽≥1.60m，床周预留≥0.8m 操作空间，确保医护巡回护理与家长陪护无拥挤。",
      "空间模数与净空 / 室内净高控制：为改善多人居住空间压抑感，同时容纳顶部设备与照明，室内吊顶净高建议设定为 2.80m。",
      "感控要求与设施 / 手卫生设施配置：病房两端各配置 1 组感应洗手池与手消毒液分配器，每张病床旁增设移动手消液架；配备 2 台空气消毒机，轮换对不同区域消毒。",
      "感控要求与设施 / 通风与消毒条件：采用机械通风为主、自然通风为辅，换气次数≥8 次 / 小时；地面、墙面采用无缝耐消毒材料，墙角做圆弧处理，无卫生死角。",
      "感控要求与设施 / 污物收集设施：病房中部设置双分类密闭垃圾桶（医疗废物、生活垃圾），带盖设计；卫生间设专用污物通道，与清洁区域物理隔离。",
      "室内装修与防护 / 墙地顶易洁与防撞：地面采用防滑等级≥R10 的同质透心 PVC 卷材，上卷上墙 15cm；墙面 1.2m 以下设防撞墙裙，所有阳角执行 R≥20mm 圆角工艺。",
      "室内装修与防护 / 家具安全与固定：病床、储物柜、公共座椅等全部固定安装，无尖锐边角；儿童病床带可调节护栏，床高统一为 0.65m，适配护理操作。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "病房使用面积",
        "requirement": "四人病房使用面积不应小于 32.00㎡。",
        "source": "《综合医院建筑设计标准》GB 51039-2014",
        "suggestion": "考虑儿童陪护与群体康复需求，建议使用面积扩大至 35.00㎡至 38.00㎡，预留公共活动与设备摆放空间。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "病床间距与通道",
        "requirement": "病床净间距不应小于 1.20m，病房内主通道净宽不应小于 1.40m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014",
        "suggestion": "病床净间距≥1.50m，主通道净宽≥1.60m，床周预留≥0.8m 操作空间，确保医护巡回护理与家长陪护无拥挤。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "室内净高控制",
        "requirement": "病房室内净高不宜低于 2.60m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014",
        "suggestion": "为改善多人居住空间压抑感，同时容纳顶部设备与照明，室内吊顶净高建议设定为 2.80m。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "手卫生设施配置",
        "requirement": "病房应设置足够的非接触式手卫生设施，满足感控要求。",
        "source": "GB/T 39498-2020《医疗机构感染预防与控制基本准则》",
        "suggestion": "病房两端各配置 1 组感应洗手池与手消毒液分配器，每张病床旁增设移动手消液架；配备 2 台空气消毒机，轮换对不同区域消毒。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "通风与消毒条件",
        "requirement": "病房应具备良好的通风条件，墙面、地面应便于清洁消毒。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.3.2 条、第 5.1.10 条",
        "suggestion": "采用机械通风为主、自然通风为辅，换气次数≥8 次 / 小时；地面、墙面采用无缝耐消毒材料，墙角做圆弧处理，无卫生死角。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "污物收集设施",
        "requirement": "病房应设置分类污物收集容器，集中存放医疗废物与生活垃圾。",
        "source": "《儿童医院建设标准》建标 174-2016 第 47 条",
        "suggestion": "病房中部设置双分类密闭垃圾桶（医疗废物、生活垃圾），带盖设计；卫生间设专用污物通道，与清洁区域物理隔离。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "墙地顶易洁与防撞",
        "requirement": "医疗用房的地面、墙面、顶棚应便于清扫；儿童区域应采取防撞措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.1.12 条",
        "suggestion": "地面采用防滑等级≥R10 的同质透心 PVC 卷材，上卷上墙 15cm；墙面 1.2m 以下设防撞墙裙，所有阳角执行 R≥20mm 圆角工艺。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "家具安全与固定",
        "requirement": "儿童诊疗区域的家具应采取固定措施，防止倾倒伤人。",
        "source": "《综合医院建设标准》建标 110-2021 第三十九条",
        "suggestion": "病床、储物柜、公共座椅等全部固定安装，无尖锐边角；儿童病床带可调节护栏，床高统一为 0.65m，适配护理操作。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "声光环境控制",
        "requirement": "医院建筑应注重改善患者的就医环境，减少噪音干扰。",
        "source": "《综合医院建设标准》建标 110-2021 第五条",
        "suggestion": "墙面、顶棚采用吸音材料，降低环境噪音（控制在 45dB 以内）；照明采用分区柔光设计，避免眩光，每张病床配置独立照明开关。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "公共活动空间",
        "requirement": "多人病房应预留公共活动区域，满足儿童互动需求。",
        "source": "《儿童医院建设标准》建标 174-2016 第 35 条",
        "suggestion": "病房中部预留≥4㎡公共活动区，配备小型安全玩具与绘本架；活动区地面铺防滑软垫，周边无硬质障碍物。"
      },
      {
        "dimension": "安全出口与疏散门",
        "focus": "门洞净宽与无障碍",
        "requirement": "病房门净宽不应小于 1.00m；疏散出口门不应设置门槛。",
        "source": "《综合医院建筑设计标准》GB 51039-2014《建筑防火通用规范》GB 55037-2022",
        "suggestion": "病房门采用双扇门，净宽≥1.2m，门下无门槛，便于多人同时疏散与平车通行；门体设观察窗与防撞条。"
      },
      {
        "dimension": "安全出口与疏散门",
        "focus": "隐私与隔断保护",
        "requirement": "病房床间应设置隔帘，保障患者隐私。",
        "source": "《综合医院建设标准》建标 110-2021 第三十九条",
        "suggestion": "每张病床配置独立隔断帘，轨道覆盖全床范围；隔断帘采用阻燃、易清洗材质，定期更换消毒。"
      },
      {
        "dimension": "建筑防火",
        "focus": "材料燃烧性能",
        "requirement": "医疗建筑内部装修材料的燃烧性能等级不应低于 A 级，部分部位不应低于 B1 级。",
        "source": "《建筑防火通用规范》GB 55037-2022 第 6.1.1 条",
        "suggestion": "顶棚、墙面、地面采用 A 级不燃材料，窗帘、隔断帘等软装选用 B1 级阻燃材料；公共活动区玩具、绘本采用无毒阻燃材质。"
      },
      {
        "dimension": "建筑防火",
        "focus": "消防设施配置",
        "requirement": "病房应按规范配置消防设施，避免遮挡与误触。",
        "source": "《建筑防火通用规范》GB 55037-2022 第 6.5.1 条",
        "suggestion": "病房内均匀配置 2 组灭火器，位置醒目且便于取用；烟感探测器、喷淋头避开设备与家具遮挡，确保感应灵敏。"
      }
    ],
    "legacySiteModel": "models/model-real.html?space=ward",
    "sceneInfo": {
      "area": "8.40 × 6.00 m 四床病房 + 中央护理通道 · 净高 3.00m（≈50.4㎡）",
      "dims": {
        "def": [
          8.4,
          6,
          3
        ],
        "min": [
          7.8,
          5.6,
          2.8
        ],
        "sugg": [
          9,
          6.6,
          3.1
        ],
        "minLabel": "紧凑四床",
        "suggLabel": "护理优化"
      },
      "markers": 6,
      "source": "2026.7.6 住院CAD/SKP + AusHFG住院/儿少/标准组件比对",
      "norms": [
        "规范底线：四人病房≥32㎡",
        "床间净距≥1.20m",
        "主通道≥1.40m",
        "净高≥2.60m"
      ],
      "compliance": [
        "面积差值：模型示范约50.4㎡，规范底线≥32㎡，高出约18.4㎡。",
        "口径说明：规范底线用于审图合规判断，模型示范尺寸用于表达陪护、设备、活动和维护余量，不应写成规范最低值。"
      ]
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 55,
      "priority": "P1",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 57,
      "finalStatus": "部分完成",
      "finalRequirement": "三号座椅退出入口；四床隔帘均可运动；床头设备带贴墙。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "wd_nurse_station",
    "dept": "住院",
    "name": "病房护士站",
    "type": "ward",
    "priority": "P3",
    "summary": "病房护士站审图重点包括护士站使用面积、服务半径与视野、室内净高控制等内容；依据《综合医院建筑设计标准》GB 51039-2014 第 5.3.3 条；《儿童医院建设标准》建标 174-2016 第 28 条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/住院/CAD/住院病房重绘_t3.dwg"
    ],
    "rules": [
      "area",
      "handwash",
      "privacy",
      "child"
    ],
    "siteModel": "models/viewer.html?scene=wd-nurse-station",
    "siteModelName": "3D交互信息模型（病房护士站 · 住院部）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "病房护士站审图重点包括护士站使用面积、服务半径与视野、室内净高控制等内容；依据《综合医院建筑设计标准》GB 51039-2014 第 5.3.3 条；《儿童医院建设标准》建标 174-2016 第 28 条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "护士站使用面积：病房护士站使用面积不应小于 20.00㎡。",
      "服务半径与视野：护士站应位于护理单元中心，视野覆盖全病房区。",
      "室内净高控制：公共区域室内净高不宜低于 2.70m。",
      "手卫生设施配置：护士站应设置非接触式手卫生设施，满足医护人员手卫生需求。",
      "物资分类存放：医疗物资应分类存放，清洁物品与污染物品严格分离。",
      "消毒设施配置：护士站应配备必要的消毒设施，定期对工作区域进行消毒。"
    ],
    "docReview": [
      "空间模数与净空 / 护士站使用面积：考虑儿童住院护理工作量大，建议使用面积扩大至 22.00㎡至 25.00㎡，预留教学与物资存放空间。",
      "空间模数与净空 / 服务半径与视野：护士站采用岛式或半开放式布局，服务半径≤30m，确保护士能快速响应各床位呼叫；通过透明玻璃观察窗，实现对病房区 100% 无死角监控。",
      "空间模数与净空 / 室内净高控制：为容纳顶部监控设备、照明与机电管线，室内吊顶净高建议设定为 2.80m。",
      "感控要求与设施 / 手卫生设施配置：护士站工作台旁配置感应式洗手池与手消毒液分配器，确保医护人员诊疗前后快速完成手卫生；洗手池设防溅挡板，避免污水外溢。",
      "感控要求与设施 / 物资分类存放：护士站设置双层储物柜，上层存放清洁医疗物资，下层存放常用器械与文件；配置密闭污物盒，分类收集医疗废物与生活垃圾。",
      "感控要求与设施 / 消毒设施配置：配备紫外线消毒灯或空气消毒机，每日定时对护士站区域消毒；工作台面采用耐消毒抗菌材料，支持高频次擦拭消毒。",
      "室内装修与防护 / 墙地顶易洁与防撞：地面采用同质透心防滑 PVC 卷材，墙面 1.2m 以下设防撞墙裙；护士站转角做 R≥20mm 圆角处理，避免推床与人员碰撞。",
      "室内装修与防护 / 工作台适配性：工作台高度设高低位（0.75m/0.9m），适配坐姿与站姿操作；台面预留电脑、打印机、呼叫系统等设备接口，布线整洁有序。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "护士站使用面积",
        "requirement": "病房护士站使用面积不应小于 20.00㎡。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.3.3 条",
        "suggestion": "考虑儿童住院护理工作量大，建议使用面积扩大至 22.00㎡至 25.00㎡，预留教学与物资存放空间。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "服务半径与视野",
        "requirement": "护士站应位于护理单元中心，视野覆盖全病房区。",
        "source": "《儿童医院建设标准》建标 174-2016 第 28 条",
        "suggestion": "护士站采用岛式或半开放式布局，服务半径≤30m，确保护士能快速响应各床位呼叫；通过透明玻璃观察窗，实现对病房区 100% 无死角监控。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "室内净高控制",
        "requirement": "公共区域室内净高不宜低于 2.70m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.1.9 条",
        "suggestion": "为容纳顶部监控设备、照明与机电管线，室内吊顶净高建议设定为 2.80m。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "手卫生设施配置",
        "requirement": "护士站应设置非接触式手卫生设施，满足医护人员手卫生需求。",
        "source": "GB/T 39498-2020《医疗机构感染预防与控制基本准则》",
        "suggestion": "护士站工作台旁配置感应式洗手池与手消毒液分配器，确保医护人员诊疗前后快速完成手卫生；洗手池设防溅挡板，避免污水外溢。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "物资分类存放",
        "requirement": "医疗物资应分类存放，清洁物品与污染物品严格分离。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.3.3 条",
        "suggestion": "护士站设置双层储物柜，上层存放清洁医疗物资，下层存放常用器械与文件；配置密闭污物盒，分类收集医疗废物与生活垃圾。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "消毒设施配置",
        "requirement": "护士站应配备必要的消毒设施，定期对工作区域进行消毒。",
        "source": "GB/T 39498-2020《医疗机构感染预防与控制基本准则》",
        "suggestion": "配备紫外线消毒灯或空气消毒机，每日定时对护士站区域消毒；工作台面采用耐消毒抗菌材料，支持高频次擦拭消毒。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "墙地顶易洁与防撞",
        "requirement": "医疗用房的地面、墙面、顶棚应便于清扫；有推床通过的区域应采取防撞措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.1.12 条",
        "suggestion": "地面采用同质透心防滑 PVC 卷材，墙面 1.2m 以下设防撞墙裙；护士站转角做 R≥20mm 圆角处理，避免推床与人员碰撞。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "工作台适配性",
        "requirement": "护士站工作台应符合人体工程学要求，便于医护操作。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.3.3 条",
        "suggestion": "工作台高度设高低位（0.75m/0.9m），适配坐姿与站姿操作；台面预留电脑、打印机、呼叫系统等设备接口，布线整洁有序。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "声光环境控制",
        "requirement": "护士站应保持相对安静，避免噪音干扰工作。",
        "source": "《综合医院建设标准》建标 110-2021 第五条",
        "suggestion": "墙面、顶棚采用吸音材料，降低环境噪音（控制在 50dB 以内）；呼叫系统音量可调节，避免噪音引发患儿焦虑。"
      },
      {
        "dimension": "安全出口与疏散门",
        "focus": "疏散路径畅通",
        "requirement": "护士站周边疏散路径无障碍物，便于紧急情况下快速撤离。",
        "source": "《建筑防火通用规范》GB 55037-2022 第 7.1.4 条",
        "suggestion": "护士站与疏散通道保持畅通，无杂物堆放；工作台布置不遮挡疏散门，确保紧急情况下医护人员快速响应。"
      },
      {
        "dimension": "安全出口与疏散门",
        "focus": "应急设施配置",
        "requirement": "护士站应配备应急呼叫系统、应急照明与通讯设备。",
        "source": "《儿童医院建设标准》建标 174-2016 第 28 条",
        "suggestion": "配置紧急呼叫主机，与各病房呼叫按钮联动，30 秒内响应；配备应急手电筒、对讲机，确保突发情况下通讯畅通；应急照明持续供电≥90min。"
      },
      {
        "dimension": "建筑防火",
        "focus": "材料燃烧性能",
        "requirement": "医疗建筑内部装修材料的燃烧性能等级不应低于 A 级，部分部位不应低于 B1 级。",
        "source": "《建筑防火通用规范》GB 55037-2022 第 6.1.1 条",
        "suggestion": "顶棚、墙面、地面采用 A 级不燃材料，工作台、储物柜采用阻燃环保材质；严禁使用易燃装饰材料，减少火灾荷载。"
      },
      {
        "dimension": "建筑防火",
        "focus": "消防设施保护",
        "requirement": "建筑内部装修不应擅自减少、改动、拆除、遮挡消防设施或器材及其标识。",
        "source": "《建筑防火通用规范》GB 55037-2022 第 6.5.1 条",
        "suggestion": "护士站内烟感探测器、喷淋头无遮挡，消防栓位置醒目且便于取用；严禁用文件、设备遮挡消防标识与设施。"
      }
    ],
    "legacySiteModel": "models/model-real.html?space=ward",
    "sceneInfo": {
      "area": "7.20 × 4.80 m 开放护士站 + 药品/洁物 + 观察面 · 净高 3.00m（≈34.6㎡）",
      "dims": {
        "def": [
          7.2,
          4.8,
          3
        ],
        "min": [
          6,
          4.2,
          2.8
        ],
        "sugg": [
          8.4,
          5.4,
          3.1
        ],
        "minLabel": "SSTN-10扩展",
        "suggLabel": "SSTN-20"
      },
      "markers": 6,
      "source": "2026.7.6 住院CAD/SKP + AusHFG住院/儿少/标准组件比对",
      "norms": [
        "规范底线：护士站≥20㎡",
        "位于护理单元中心",
        "视野覆盖病房区",
        "公共区净高≥2.70m"
      ],
      "compliance": [
        "面积差值：模型示范约34.6㎡，规范底线≥20㎡，高出约14.6㎡。",
        "口径说明：规范底线用于审图合规判断，模型示范尺寸用于表达陪护、设备、活动和维护余量，不应写成规范最低值。"
      ]
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 47,
      "priority": "P3",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 49,
      "finalStatus": "部分完成",
      "finalRequirement": "护士站后退；呼叫屏点击可高亮床位；椅子与人员绑定。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "wd_single",
    "dept": "住院",
    "name": "单人病房",
    "type": "ward",
    "priority": "P3",
    "summary": "单人病房审图重点包括病房使用面积、病床操作空间、室内净高控制等内容；依据《综合医院建筑设计标准》GB 51039-2014 第 5.3.2 条；《综合医院建筑设计标准》GB 51039-2014 第 5.1.9 条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/住院/CAD/住院病房重绘_t3.dwg"
    ],
    "rules": [
      "area",
      "handwash",
      "privacy",
      "child"
    ],
    "siteModel": "models/viewer.html?scene=wd-single",
    "siteModelName": "3D交互信息模型（单人病房 · 住院部）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "单人病房审图重点包括病房使用面积、病床操作空间、室内净高控制等内容；依据《综合医院建筑设计标准》GB 51039-2014 第 5.3.2 条；《综合医院建筑设计标准》GB 51039-2014 第 5.1.9 条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "病房使用面积：单人病房使用面积不应小于 18.00㎡。",
      "病床操作空间：病床与墙面净距不应小于 0.60m，病床端部与墙面净距不应小于 1.00m。",
      "室内净高控制：病房室内净高不宜低于 2.60m。",
      "手卫生设施配置：病房应设置非接触式手卫生设施，满足感控要求。",
      "通风与消毒条件：病房应具备良好的通风条件，墙面、地面应便于清洁消毒。",
      "污物收集设施：病房应设置独立的污物收集容器，分类存放医疗废物与生活垃圾。"
    ],
    "docReview": [
      "空间模数与净空 / 病房使用面积：考虑儿童陪护与特殊治疗需求，建议使用面积扩大至 20.00㎡至 22.00㎡，预留设备与陪护休息空间。",
      "空间模数与净空 / 病床操作空间：病床与墙面净距≥0.80m，端部净距≥1.20m，床周预留≥1.0m 全周操作通道，满足医护多方向护理与设备摆放。",
      "空间模数与净空 / 室内净高控制：为容纳医疗设备带、隔帘轨道及改善空间压抑感，室内吊顶净高建议设定为 2.80m。",
      "感控要求与设施 / 手卫生设施配置：独立卫生间内配置感应水龙头与手消毒液分配器，病床旁增设移动手消液架，实现 “床旁手卫生” 便捷化；配备空气消毒机，每日定时消毒。",
      "感控要求与设施 / 通风与消毒条件：采用自然通风与机械通风结合，换气次数≥8 次 / 小时；地面、墙面采用耐消毒抗菌材料，无卫生死角，支持高频次消杀。",
      "感控要求与设施 / 污物收集设施：病房内设置双分类密闭垃圾桶（医疗废物、生活垃圾），带盖设计；卫生间设专用污水排放口与防臭装置，避免异味溢出。",
      "室内装修与防护 / 墙地顶易洁与防撞：地面采用同质透心抗菌 PVC 卷材，上卷上墙 15cm；墙面 1.2m 以下设防撞墙裙，所有阳角执行 R≥20mm 圆角工艺，避免磕碰。",
      "室内装修与防护 / 家具安全与固定：病床、储物柜、陪护沙发等全部固定安装，无尖锐边角；儿童病床带可调节护栏（高度≥0.6m），床高适配护理操作（0.6-0.7m）。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "病房使用面积",
        "requirement": "单人病房使用面积不应小于 18.00㎡。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.3.2 条",
        "suggestion": "考虑儿童陪护与特殊治疗需求，建议使用面积扩大至 20.00㎡至 22.00㎡，预留设备与陪护休息空间。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "病床操作空间",
        "requirement": "病床与墙面净距不应小于 0.60m，病床端部与墙面净距不应小于 1.00m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.3.2 条",
        "suggestion": "病床与墙面净距≥0.80m，端部净距≥1.20m，床周预留≥1.0m 全周操作通道，满足医护多方向护理与设备摆放。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "室内净高控制",
        "requirement": "病房室内净高不宜低于 2.60m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.1.9 条",
        "suggestion": "为容纳医疗设备带、隔帘轨道及改善空间压抑感，室内吊顶净高建议设定为 2.80m。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "手卫生设施配置",
        "requirement": "病房应设置非接触式手卫生设施，满足感控要求。",
        "source": "GB/T 39498-2020《医疗机构感染预防与控制基本准则》",
        "suggestion": "独立卫生间内配置感应水龙头与手消毒液分配器，病床旁增设移动手消液架，实现 “床旁手卫生” 便捷化；配备空气消毒机，每日定时消毒。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "通风与消毒条件",
        "requirement": "病房应具备良好的通风条件，墙面、地面应便于清洁消毒。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.3.2 条、第 5.1.10 条",
        "suggestion": "采用自然通风与机械通风结合，换气次数≥8 次 / 小时；地面、墙面采用耐消毒抗菌材料，无卫生死角，支持高频次消杀。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "污物收集设施",
        "requirement": "病房应设置独立的污物收集容器，分类存放医疗废物与生活垃圾。",
        "source": "《儿童医院建设标准》建标 174-2016 第 47 条",
        "suggestion": "病房内设置双分类密闭垃圾桶（医疗废物、生活垃圾），带盖设计；卫生间设专用污水排放口与防臭装置，避免异味溢出。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "墙地顶易洁与防撞",
        "requirement": "医疗用房的地面、墙面、顶棚应便于清扫；儿童区域应采取防撞措施。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.1.12 条",
        "suggestion": "地面采用同质透心抗菌 PVC 卷材，上卷上墙 15cm；墙面 1.2m 以下设防撞墙裙，所有阳角执行 R≥20mm 圆角工艺，避免磕碰。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "家具安全与固定",
        "requirement": "儿童诊疗区域的家具应采取固定措施，防止倾倒伤人。",
        "source": "《综合医院建设标准》建标 110-2021 第三十九条",
        "suggestion": "病床、储物柜、陪护沙发等全部固定安装，无尖锐边角；儿童病床带可调节护栏（高度≥0.6m），床高适配护理操作（0.6-0.7m）。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "声光环境控制",
        "requirement": "医院建筑应注重改善患者的就医环境，减少噪音干扰。",
        "source": "《综合医院建设标准》建标 110-2021 第五条",
        "suggestion": "墙面、顶棚采用吸音材料，降低环境噪音（控制在 40dB 以内）；照明采用柔光设计，避免眩光，配置床头独立照明与呼叫系统音量调节功能。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "陪护空间适配",
        "requirement": "病房应预留亲属陪护空间，宜设置陪护床或陪护椅。",
        "source": "《儿童医院建设标准》建标 174-2016 第 36 条",
        "suggestion": "配置可折叠陪护沙发床（展开尺寸≥1.8m×0.7m），病房角落规划独立陪护休息区，配备充电接口与小桌板，提升陪护舒适度。"
      },
      {
        "dimension": "安全出口与疏散门",
        "focus": "门洞净宽与无障碍",
        "requirement": "病房门净宽不应小于 0.90m；疏散出口门不应设置门槛。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.1.4 条、《建筑防火通用规范》GB 55037-2022 第 7.2.1 条",
        "suggestion": "病房门采用子母门，净宽≥1.0m，门下无门槛，便于轮椅、平车通行；门体设观察窗与防撞条，避免开门碰撞。"
      },
      {
        "dimension": "安全出口与疏散门",
        "focus": "隐私与隔断保护",
        "requirement": "病房应保障患者隐私，设置隔帘或屏风。",
        "source": "《综合医院建设标准》建标 110-2021 第三十九条",
        "suggestion": "天花板预留 U 型隔帘轨道，覆盖全床范围；病房门开启方向避免走廊直视病床，保护诊疗与休息隐私。"
      },
      {
        "dimension": "建筑防火",
        "focus": "材料燃烧性能",
        "requirement": "医疗建筑内部装修材料的燃烧性能等级不应低于 A 级，部分部位不应低于 B1 级。",
        "source": "《建筑防火通用规范》GB 55037-2022 第 6.1.1 条",
        "suggestion": "顶棚、墙面、地面采用 A 级不燃材料，陪护沙发、窗帘等软装选用 B1 级阻燃材料；严禁使用易燃、易挥发有害物质的装修材料。"
      },
      {
        "dimension": "建筑防火",
        "focus": "消防设施配置",
        "requirement": "病房应按规范配置消防设施，避免遮挡与误触。",
        "source": "《建筑防火通用规范》GB 55037-2022 第 6.5.1 条",
        "suggestion": "病房内配置灭火器，位置醒目且便于取用；烟感探测器、喷淋头避开家具与设备遮挡，与医疗设备带保持安全距离（≥0.5m）。"
      }
    ],
    "legacySiteModel": "models/model-real.html?space=ward",
    "sceneInfo": {
      "area": "5.40 × 4.20 m 单床病房 + 陪护 + 卫生间接口 · 净高 3.00m（≈22.7㎡）",
      "dims": {
        "def": [
          5.4,
          4.2,
          3
        ],
        "min": [
          4.8,
          3.8,
          2.8
        ],
        "sugg": [
          6,
          4.8,
          3.1
        ],
        "minLabel": "模型紧凑",
        "suggLabel": "陪护优化"
      },
      "markers": 6,
      "source": "2026.7.6 住院CAD/SKP + AusHFG住院/儿少/标准组件比对",
      "norms": [
        "规范底线：单人病房≥18㎡",
        "床墙净距≥0.60m",
        "床端净距≥1.00m",
        "净高≥2.60m"
      ],
      "compliance": [
        "面积差值：模型示范约22.7㎡，规范底线≥18㎡，高出约4.7㎡。",
        "口径说明：规范底线用于审图合规判断，模型示范尺寸用于表达陪护、设备、活动和维护余量，不应写成规范最低值。"
      ]
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 49,
      "priority": "P3",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 51,
      "finalStatus": "已完成",
      "finalRequirement": "保留陪护动态与担架转运状态。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "wd_unit",
    "dept": "住院",
    "name": "住院单元",
    "type": "ward",
    "priority": "P1",
    "summary": "三级儿童医院36床护理单元关系模型，按最新2026.7.6住院SKP/DWG与规范复核，表达35-45床单元规模、中心护士站、病房组团、洁污支持、家属等候与儿童学习活动。",
    "assets": [
      "docs/materials/2026.7.6/住院/CAD/住院病房重绘_t3.dwg",
      "docs/materials/2026.7.6/住院/模型/住院2.skp"
    ],
    "rules": [
      "area",
      "handwash",
      "privacy",
      "child"
    ],
    "siteModel": "models/viewer.html?scene=wd-unit",
    "siteModelName": "3D交互信息模型（住院单元 · 住院部）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "住院单元按儿童医院护理单元复核：建标174-2016要求儿童医院病房护理单元一般宜按35-45床设置，并配置儿童学习活动、亲属陪护与污物收集；模型以36床关系模型表达，而非6床房间拼贴。",
    "docFacts": [
      "护理单元规模：儿童医院病房的护理单元床位数一般宜按照35张～45张设置；模型以36床抽象关系表达。",
      "护士站与支持用房：护理单元应设护士站、治疗室、处置室、洗消间、更衣室、值班室等，护士站应与治疗室、办公用房邻近。",
      "通道尺度：住院部走廊净宽不应小于2.4m，模型主走廊以平车通行标注。",
      "儿童学习活动：病房区域应配套设置儿童学习、活动空间，护理单元设置家属等候/儿童学习活动区。",
      "陪护需求：病房应预留亲属陪护空间，宜设置陪护床或陪护椅。",
      "医疗废物处理：护理单元与病房均需配置医疗废物与生活垃圾分类收集、密闭转运逻辑。",
      "最新素材：按2026.7.6/住院目录内住院2.skp与住院病房重绘_t3.dwg核对，发布系统副本哈希一致。"
    ],
    "docReview": [
      "空间尺度 / 护理单元规模：护理单元床位数控制在 35-40 张，避免规模过大导致护理效率下降；每个护理单元设单人间、双人间、多人间，满足不同需求。",
      "空间尺度 / 病房面积与间距：双人病房使用面积≥26.0㎡，病床净间距≥1.5m；单人病房净面积≥18.0㎡，四人病房≥35.0㎡，VIP 病房≥25.0㎡，预留陪护与设备空间。",
      "空间尺度 / 通道与电梯配置：病房走廊净宽≥2.6m，满足推床与陪护人员并行；每护理单元配置不少于 2 台病床梯，电梯门净宽≥1.5m，适配急救转运。",
      "感控要求 / 三级感控分区：病房、护士站为清洁区，治疗室为半污染区，污物间、洗涤间为污染区；各区物理隔离，设置明显标识，流线单向不可逆。",
      "感控要求 / 医疗废物处理：每个护理单元设密闭污物暂存间，医疗废物按分类收集 - 密闭转运 - 集中暂存闭环处理；污物通道独立，与清洁通道无交叉，远离诊疗区。",
      "感控要求 / 病房感控配置：病房采用自然通风与机械通风结合，换气次数≥6 次 / 小时；床单元一用一消毒，高频接触表面采用耐消毒材料，配置非接触式手卫生设施。",
      "流线效率 / 医患分流完整性：医护通道与患者通道物理分隔，医护可通过专用通道直达病房、治疗室，净宽≥1.2m；患者流线形成 “入院 - 诊疗 - 护理 - 康复 - 出院” 闭环，无交叉折返。",
      "流线效率 / 出入院动线便捷性：出入院办理区紧邻住院部入口，与病房流线无交叉；整合登记、缴费、医保结算功能，实现 “一站式” 服务，减少家长往返。"
    ],
    "docReviewRows": [
      {
        "dimension": "模型表达",
        "focus": "模型表达口径",
        "requirement": "儿童医院护理单元宜按35张～45张设置。",
        "source": "《儿童医院建设标准》建标174-2016 第35条",
        "suggestion": "当前3D模型为36床护理单元关系模型，床位构件为抽象示意，重点表达护士站居中、病房组团、洁污支持、家属等候与儿童活动之间的组织关系。"
      },
      {
        "dimension": "空间尺度",
        "focus": "护理单元规模",
        "requirement": "儿童医院病房的护理单元床位数一般宜按照 35 张～45 张设置。",
        "source": "《儿童医院建设标准》建标 174-2016 第 35 条",
        "suggestion": "护理单元床位数控制在 35-40 张，避免规模过大导致护理效率下降；每个护理单元设单人间、双人间、多人间，满足不同需求。"
      },
      {
        "dimension": "空间尺度",
        "focus": "病房面积与间距",
        "requirement": "双人病房使用面积不应小于 24.0㎡，病床净间距不应小于 1.2m；四人病房使用面积不应小于 32.0㎡。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.3.2 条",
        "suggestion": "双人病房使用面积≥26.0㎡，病床净间距≥1.5m；单人病房净面积≥18.0㎡，四人病房≥35.0㎡，VIP 病房≥25.0㎡，预留陪护与设备空间。"
      },
      {
        "dimension": "空间尺度",
        "focus": "通道与电梯配置",
        "requirement": "住院部走廊净宽不应小于 2.4m；四层及以上医疗用房应设电梯且不少于两台。",
        "source": "《儿童医院建设标准》建标 174-2016 第 31 条、第 48 条",
        "suggestion": "病房走廊净宽≥2.6m，满足推床与陪护人员并行；每护理单元配置不少于 2 台病床梯，电梯门净宽≥1.5m，适配急救转运。"
      },
      {
        "dimension": "感控要求",
        "focus": "三级感控分区",
        "requirement": "医疗用房应按清洁区、半污染区、污染区划分，分区明确，流线不交叉。",
        "source": "GB/T 39498-2020《医疗机构感染预防与控制基本准则》",
        "suggestion": "病房、护士站为清洁区，治疗室为半污染区，污物间、洗涤间为污染区；各区物理隔离，设置明显标识，流线单向不可逆。"
      },
      {
        "dimension": "感控要求",
        "focus": "医疗废物处理",
        "requirement": "医院应设置医疗废物收集、暂存设施，处理流程符合规范。",
        "source": "《儿童医院建设标准》建标 174-2016 第 47 条",
        "suggestion": "每个护理单元设密闭污物暂存间，医疗废物按分类收集 - 密闭转运 - 集中暂存闭环处理；污物通道独立，与清洁通道无交叉，远离诊疗区。"
      },
      {
        "dimension": "感控要求",
        "focus": "病房感控配置",
        "requirement": "病房应具备良好的通风、采光条件，满足消毒隔离要求。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.3.2 条",
        "suggestion": "病房采用自然通风与机械通风结合，换气次数≥6 次 / 小时；床单元一用一消毒，高频接触表面采用耐消毒材料，配置非接触式手卫生设施。"
      },
      {
        "dimension": "流线效率",
        "focus": "医患分流完整性",
        "requirement": "医院建筑应做到功能分区合理，洁污路线清楚，医患分流明确。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.1.1 条",
        "suggestion": "医护通道与患者通道物理分隔，医护可通过专用通道直达病房、治疗室，净宽≥1.2m；患者流线形成 “入院 - 诊疗 - 护理 - 康复 - 出院” 闭环，无交叉折返。"
      },
      {
        "dimension": "流线效率",
        "focus": "出入院动线便捷性",
        "requirement": "住院部应设置独立的出入院办理区，位置靠近住院入口。",
        "source": "《儿童医院建设标准》建标 174-2016 专项要求",
        "suggestion": "出入院办理区紧邻住院部入口，与病房流线无交叉；整合登记、缴费、医保结算功能，实现 “一站式” 服务，减少家长往返。"
      },
      {
        "dimension": "流线效率",
        "focus": "辅助功能邻近性",
        "requirement": "住院部应邻近医技科室、手术部、急诊部，便于患者转运。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 4.2.1 条",
        "suggestion": "护理单元内辅助治疗室、处置室紧邻病房布置；住院部与核心医技部（影像、检验）通过专用通道或电梯联动，转运距离≤30m。"
      },
      {
        "dimension": "协作配套",
        "focus": "亲子陪护设施",
        "requirement": "病房应预留亲属陪护空间，宜设置陪护床或陪护椅。",
        "source": "《儿童医院建设标准》建标 174-2016 第 36 条",
        "suggestion": "双人及以上病房每床配置可折叠陪护椅（夜间展开为床），单人病房设固定陪护沙发床；护理单元设亲子活动区，配备简易玩具与休息设施。"
      },
      {
        "dimension": "协作配套",
        "focus": "生活配套服务",
        "requirement": "住院部应配置食堂、商店、洗衣房等生活服务设施，满足患者与家属需求。",
        "source": "《综合医院建设标准》建标 110-2021 专项要求",
        "suggestion": "每层设置饮水间、微波炉（专用区域），配置儿童专用饮水设施；设母婴室、儿童专用卫生间、临时哺乳角，满足特殊需求。"
      },
      {
        "dimension": "协作配套",
        "focus": "康复与活动空间",
        "requirement": "病房区域应配套设置儿童学习、活动空间。",
        "source": "《儿童医院建设标准》建标 174-2016 第 35 条",
        "suggestion": "每个护理单元设儿童康复活动区（≥15㎡），按年龄段配置安全玩具、绘本、学习桌；院区设室外活动场所，绿化覆盖率≥35%。"
      },
      {
        "dimension": "无障碍与应急疏散",
        "focus": "儿童安全防护",
        "requirement": "儿童诊疗区域的门窗、家具和楼地面等应采取必要的安全保护措施。",
        "source": "《综合医院建设标准》建标 110-2021 第三十九条",
        "suggestion": "病房内所有阳角执行 R≥20mm 圆角工艺，窗台高度≥0.9m，阳台设防护栏杆（高度≥1.1m）；电源插座高度≥1.5m 或加装防护盖。"
      },
      {
        "dimension": "无障碍与应急疏散",
        "focus": "无障碍全流程适配",
        "requirement": "医院建筑应符合现行国家标准《无障碍设计规范》的规定。",
        "source": "《儿童医院建设标准》建标 174-2016 第 32 条",
        "suggestion": "病房、走廊、电梯预留轮椅回转空间（≥1.5m×1.5m），房门净宽≥0.9m；护士站、服务台设低位服务窗口，无障碍设施全程无高差。"
      },
      {
        "dimension": "无障碍与应急疏散",
        "focus": "疏散能力与路线",
        "requirement": "疏散出口门、疏散走道的净宽度应满足安全疏散要求，疏散路线清晰。",
        "source": "《建筑防火通用规范》GB 55037-2022 第 7.1.4 条",
        "suggestion": "疏散通道净宽≥2.0m，楼梯间净宽≥1.6m；疏散路线结合亲子动线设计，设置临时避险区，配备应急医疗设施与饮用水。"
      },
      {
        "dimension": "无障碍与应急疏散",
        "focus": "平急转换能力",
        "requirement": "医院建筑应具备平急转换能力，可快速应对突发公共卫生事件。",
        "source": "《儿童医院建设标准》建标 174-2016 专项要求",
        "suggestion": "普通病房可快速改造为应急隔离病房，预留独立通风与负压接口；护理单元预留备用床位与物资储存空间，满足应急扩容需求。"
      }
    ],
    "legacySiteModel": "models/model-real.html?space=ward",
    "sceneInfo": {
      "area": "18.00 × 12.00 m 36床护理单元关系模型画布 · 净高 3.20m（≈216㎡，非真实护理单元面积）",
      "dims": {
        "def": [
          18,
          12,
          3.2
        ],
        "min": [
          15.6,
          10.8,
          3
        ],
        "sugg": [
          21,
          13.2,
          3.4
        ],
        "minLabel": "紧凑护理单元",
        "suggLabel": "扩展护理单元"
      },
      "markers": 6,
      "source": "2026.7.6/住院 最新SKP（住院2.skp）+ CAD（住院病房重绘_t3.dwg）+ 建标174-2016/GB51039复核",
      "norms": [
        "规范底线：护理单元35-45床",
        "住院走廊≥2.40m",
        "护士站邻近治疗/处置",
        "需儿童活动/陪护支持"
      ],
      "compliance": [
        "护理单元口径：模型为36床关系模型；18.00×12.00m 是信息模型画布尺度，不作为真实护理单元建筑面积指标。",
        "规范底线：儿童医院病房护理单元一般宜按35-45床设置，住院部走廊净宽不应小于2.4m。"
      ],
      "modelScope": "关系模型",
      "measurementNotice": "仅表达科室分区、邻接与流程关系，不可用于房间净距或设备安装量测。"
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 58,
      "priority": "P1",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 60,
      "finalStatus": "部分完成",
      "finalRequirement": "明确关系模型；进入审图前重建可量测真实平面。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "wd_vip",
    "dept": "住院",
    "name": "VIP 病房",
    "type": "ward",
    "priority": "P3",
    "summary": "VIP 病房审图重点包括病房使用面积、功能分区与操作空间、室内净高控制等内容；依据《综合医院建筑设计标准》GB 51039-2014 第 5.3.2 条；《综合医院建筑设计标准》GB 51039-2014 第 5.1.9 条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/住院/CAD/住院病房重绘_t3.dwg"
    ],
    "rules": [
      "area",
      "handwash",
      "privacy",
      "child"
    ],
    "siteModel": "models/viewer.html?scene=wd-vip",
    "siteModelName": "3D交互信息模型（VIP 病房 · 住院部）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "VIP 病房审图重点包括病房使用面积、功能分区与操作空间、室内净高控制等内容；依据《综合医院建筑设计标准》GB 51039-2014 第 5.3.2 条；《综合医院建筑设计标准》GB 51039-2014 第 5.1.9 条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "病房使用面积：VIP 病房使用面积不应小于 25.00㎡。",
      "功能分区与操作空间：病房应划分清晰功能分区，病床周边预留足够操作空间。",
      "室内净高控制：病房室内净高不宜低于 2.60m。",
      "手卫生设施配置：病房应设置非接触式手卫生设施，满足感控要求。",
      "通风与消毒条件：病房应具备良好的通风条件，墙面、地面应便于清洁消毒。",
      "污物收集设施：病房应设置隐蔽式污物收集容器，分类存放医疗废物与生活垃圾。"
    ],
    "docReview": [
      "空间模数与净空 / 病房使用面积：打造家庭化高端住院环境，建议使用面积扩大至 30.00㎡至 35.00㎡，分设诊疗区、陪护休息区、独立卫生间与储物区。",
      "空间模数与净空 / 功能分区与操作空间：病床与墙面净距≥1.0m，端部净距≥1.5m，床周预留≥1.2m 全周操作通道；陪护休息区面积≥8㎡，配置独立沙发床与茶几。",
      "空间模数与净空 / 室内净高控制：为提升空间舒适度与高端氛围，室内吊顶净高建议设定为 3.00m。",
      "感控要求与设施 / 手卫生设施配置：独立卫生间内配置高端感应水龙头与手消毒液分配器，病床旁增设隐藏式手消液架；配备智能空气消毒机，自动监测并调节空气质量。",
      "感控要求与设施 / 通风与消毒条件：采用新风系统与自然通风结合，换气次数≥10 次 / 小时；地面、墙面采用进口耐消毒抗菌材料，无卫生死角，支持高频次消杀。",
      "感控要求与设施 / 污物收集设施：卫生间内设置隐藏式双分类密闭垃圾桶，带盖设计且自动感应开合；医疗废物与生活垃圾分区存放，每日专人上门清运。",
      "室内装修与防护 / 墙地顶高端适配：地面采用高端防滑地板，墙面采用环保耐擦洗壁纸（局部软包），顶棚做简约造型吊顶；所有阳角执行 R≥20mm 圆角工艺，兼顾美观与安全。",
      "室内装修与防护 / 家具安全与品质：配置高端儿童专用病床（带可调节护栏与减震功能）、实木储物柜、布艺沙发床等，全部固定安装；家具无尖锐边角，环保达标。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "病房使用面积",
        "requirement": "VIP 病房使用面积不应小于 25.00㎡。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.3.2 条",
        "suggestion": "打造家庭化高端住院环境，建议使用面积扩大至 30.00㎡至 35.00㎡，分设诊疗区、陪护休息区、独立卫生间与储物区。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "功能分区与操作空间",
        "requirement": "病房应划分清晰功能分区，病床周边预留足够操作空间。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.3.2 条",
        "suggestion": "病床与墙面净距≥1.0m，端部净距≥1.5m，床周预留≥1.2m 全周操作通道；陪护休息区面积≥8㎡，配置独立沙发床与茶几。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "室内净高控制",
        "requirement": "病房室内净高不宜低于 2.60m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.1.9 条",
        "suggestion": "为提升空间舒适度与高端氛围，室内吊顶净高建议设定为 3.00m。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "手卫生设施配置",
        "requirement": "病房应设置非接触式手卫生设施，满足感控要求。",
        "source": "GB/T 39498-2020《医疗机构感染预防与控制基本准则》",
        "suggestion": "独立卫生间内配置高端感应水龙头与手消毒液分配器，病床旁增设隐藏式手消液架；配备智能空气消毒机，自动监测并调节空气质量。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "通风与消毒条件",
        "requirement": "病房应具备良好的通风条件，墙面、地面应便于清洁消毒。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.3.2 条、第 5.1.10 条",
        "suggestion": "采用新风系统与自然通风结合，换气次数≥10 次 / 小时；地面、墙面采用进口耐消毒抗菌材料，无卫生死角，支持高频次消杀。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "污物收集设施",
        "requirement": "病房应设置隐蔽式污物收集容器，分类存放医疗废物与生活垃圾。",
        "source": "《儿童医院建设标准》建标 174-2016 第 47 条",
        "suggestion": "卫生间内设置隐藏式双分类密闭垃圾桶，带盖设计且自动感应开合；医疗废物与生活垃圾分区存放，每日专人上门清运。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "墙地顶高端适配",
        "requirement": "装修应体现高端化、家庭化，同时满足医疗使用要求。",
        "source": "《综合医院建设标准》建标 110-2021 专项要求",
        "suggestion": "地面采用高端防滑地板，墙面采用环保耐擦洗壁纸（局部软包），顶棚做简约造型吊顶；所有阳角执行 R≥20mm 圆角工艺，兼顾美观与安全。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "家具安全与品质",
        "requirement": "家具应选用高端环保材质，采取固定措施，防止倾倒伤人。",
        "source": "《综合医院建设标准》建标 110-2021 第三十九条",
        "suggestion": "配置高端儿童专用病床（带可调节护栏与减震功能）、实木储物柜、布艺沙发床等，全部固定安装；家具无尖锐边角，环保达标。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "声光环境控制",
        "requirement": "营造安静、舒适的休息环境，减少噪音与眩光干扰。",
        "source": "《综合医院建设标准》建标 110-2021 第五条",
        "suggestion": "墙面、顶棚采用高端吸音材料，降低环境噪音（控制在 38dB 以内）；照明采用分层柔光设计，配置智能调光系统，避免眩光。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "生活配套设施",
        "requirement": "配备完善的生活配套设施，满足患者与家属长期陪护需求。",
        "source": "《儿童医院建设标准》建标 174-2016 第 36 条",
        "suggestion": "独立卫生间配备淋浴、浴缸、智能马桶与婴儿整理台；陪护休息区配备冰箱、微波炉、咖啡机等生活电器；设置独立储物间，存放个人物品。"
      },
      {
        "dimension": "安全出口与疏散门",
        "focus": "门洞净宽与无障碍",
        "requirement": "病房门净宽不应小于 1.00m；疏散出口门不应设置门槛。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.1.4 条、《建筑防火通用规范》GB 55037-2022 第 7.2.1 条",
        "suggestion": "病房门采用高端隔音子母门，净宽≥1.2m，门下无门槛，便于轮椅、平车通行；门体设观察窗与防撞条，兼顾隐私与安全。"
      },
      {
        "dimension": "安全出口与疏散门",
        "focus": "隐私与隔断保护",
        "requirement": "病房应保障患者隐私，设置高端隔帘或屏风。",
        "source": "《综合医院建设标准》建标 110-2021 第三十九条",
        "suggestion": "天花板预留 U 型高端隔帘轨道，配置阻燃、隔音、易清洗的隔帘；病房门开启方向避免走廊直视病床，保护诊疗与休息隐私。"
      },
      {
        "dimension": "建筑防火",
        "focus": "材料燃烧性能",
        "requirement": "医疗建筑内部装修材料的燃烧性能等级不应低于 A 级，部分部位不应低于 B1 级。",
        "source": "《建筑防火通用规范》GB 55037-2022 第 6.1.1 条",
        "suggestion": "顶棚、地面采用 A 级不燃材料，墙面软包、窗帘等软装选用 B1 级阻燃高端材质；所有装修材料无毒、环保，符合高端住院环境要求。"
      },
      {
        "dimension": "建筑防火",
        "focus": "消防设施配置",
        "requirement": "病房应按规范配置消防设施，兼顾美观与实用性。",
        "source": "《建筑防火通用规范》GB 55037-2022 第 6.5.1 条",
        "suggestion": "病房内配置隐藏式灭火器，位置隐蔽且便于取用；烟感探测器、喷淋头采用美观造型，与装修风格协调，无遮挡且感应灵敏。"
      }
    ],
    "legacySiteModel": "models/model-real.html?space=ward",
    "sceneInfo": {
      "area": "7.80 × 5.80 m 家庭化套间 + 会客/陪护 · 净高 3.10m（≈45.2㎡）",
      "dims": {
        "def": [
          7.8,
          5.8,
          3.1
        ],
        "min": [
          7.2,
          5.2,
          2.9
        ],
        "sugg": [
          8.4,
          6.4,
          3.2
        ],
        "minLabel": "紧凑套间",
        "suggLabel": "家庭化套间"
      },
      "markers": 6,
      "source": "2026.7.6 住院CAD/SKP + AusHFG住院/儿少/标准组件比对",
      "norms": [
        "规范底线：VIP病房≥25㎡",
        "功能分区清晰",
        "床周操作空间足够",
        "净高≥2.60m"
      ],
      "compliance": [
        "面积差值：模型示范约45.2㎡，规范底线≥25㎡，高出约20.2㎡。",
        "口径说明：规范底线用于审图合规判断，模型示范尺寸用于表达陪护、设备、活动和维护余量，不应写成规范最低值。"
      ]
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 59,
      "priority": "P3",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 61,
      "finalStatus": "部分完成",
      "finalRequirement": "桌体退出入口/床位通道；补陪护动态与夜间路线。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },
    "sourceRevision": "2026-07-13 门急诊与手册更新（递归核查 63 个业务文件）"
  },
  {
    "id": "wd_water_treatment",
    "dept": "住院",
    "name": "水处理间",
    "type": "clinic",
    "priority": "P3",
    "summary": "水处理间审图重点包括处理间使用面积、设备间距与通道、室内净高控制等内容；依据《综合医院建筑设计标准》GB 51039-2014 第 5.3.7 条；《综合医院建筑设计标准》GB 51039-2014 第 5.1.9 条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "assets": [
      "docs/materials/2026.7.6/住院/CAD/住院病房重绘_t3.dwg"
    ],
    "rules": [
      "area",
      "privacy",
      "child",
      "infection"
    ],
    "siteModel": "models/viewer.html?scene=wd-water-treatment",
    "siteModelName": "3D交互信息模型（水处理间 · 住院部）",
    "docSource": "7.13_医疗工艺标准图则及审图要点.docx（内部核查源，不公开下载）",
    "docBrief": "水处理间审图重点包括处理间使用面积、设备间距与通道、室内净高控制等内容；依据《综合医院建筑设计标准》GB 51039-2014 第 5.3.7 条；《综合医院建筑设计标准》GB 51039-2014 第 5.1.9 条复核规范要求，并结合儿童医院陪护、感控、净距、设备接口和运营组织进行优化。",
    "docFacts": [
      "处理间使用面积：水处理间使用面积应根据设备规模确定，不应小于 15.00㎡。",
      "设备间距与通道：设备与墙面净距不应小于 0.80m，设备之间净距不应小于 1.00m，室内主通道净宽不应小于 1.50m。",
      "室内净高控制：设备机房室内净高不宜低于 2.80m。",
      "水质达标控制：医疗用水应符合现行国家标准《医院消毒供应中心 第 1 部分：管理规范》要求。",
      "防交叉污染：不同用途的供水管道应分开设置，避免交叉污染。",
      "排水与防回流：排水系统应畅通，设置防回流装置，防止污水回流污染。"
    ],
    "docReview": [
      "空间模数与净空 / 处理间使用面积：考虑儿童住院用水需求量与设备维护空间，建议使用面积扩大至 18.00㎡至 22.00㎡，分设设备区、操作区、检修区。",
      "空间模数与净空 / 设备间距与通道：设备与墙面净距≥1.0m，设备之间净距≥1.2m，主通道净宽≥1.8m，预留设备搬运与检修空间（≥2.0m×2.0m）。",
      "空间模数与净空 / 室内净高控制：为容纳水处理设备、管道与检修平台，室内吊顶净高建议设定为 3.00m。",
      "感控要求与设施 / 水质达标控制：配置水质在线监测系统，实时监测 pH 值、细菌总数等指标；配备软水器、活性炭过滤器、紫外线消毒器，确保水质达标。",
      "感控要求与设施 / 防交叉污染：医疗用水、生活用水管道分开铺设，标识清晰；管道采用食品级不锈钢材质，接口密封严密，定期清洗消毒。",
      "感控要求与设施 / 排水与防回流：配置防回流阀与水封装置，排水管道采用耐腐蚀材质，坡度≥3‰；设置集水坑与潜水泵，确保排水畅通，无积水。",
      "室内装修与防护 / 墙地顶耐腐易洁：地面采用防滑耐腐的工业地砖（防滑等级≥R10），墙面满铺防水防腐瓷砖（高度至顶）；顶棚采用轻钢龙骨吊顶，便于管道检修。",
      "室内装修与防护 / 设备固定与防护：所有水处理设备固定在混凝土基础上，设置减震垫；设备周边设置防护栏，高度≥0.8m，避免人员碰撞；管道做保温与防结露处理。"
    ],
    "docReviewRows": [
      {
        "dimension": "空间模数与净空",
        "focus": "处理间使用面积",
        "requirement": "水处理间使用面积应根据设备规模确定，不应小于 15.00㎡。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.3.7 条",
        "suggestion": "考虑儿童住院用水需求量与设备维护空间，建议使用面积扩大至 18.00㎡至 22.00㎡，分设设备区、操作区、检修区。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "设备间距与通道",
        "requirement": "设备与墙面净距不应小于 0.80m，设备之间净距不应小于 1.00m，室内主通道净宽不应小于 1.50m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.3.7 条",
        "suggestion": "设备与墙面净距≥1.0m，设备之间净距≥1.2m，主通道净宽≥1.8m，预留设备搬运与检修空间（≥2.0m×2.0m）。"
      },
      {
        "dimension": "空间模数与净空",
        "focus": "室内净高控制",
        "requirement": "设备机房室内净高不宜低于 2.80m。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.1.9 条",
        "suggestion": "为容纳水处理设备、管道与检修平台，室内吊顶净高建议设定为 3.00m。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "水质达标控制",
        "requirement": "医疗用水应符合现行国家标准《医院消毒供应中心 第 1 部分：管理规范》要求。",
        "source": "WS 310.1-2016《医院消毒供应中心 第 1 部分：管理规范》",
        "suggestion": "配置水质在线监测系统，实时监测 pH 值、细菌总数等指标；配备软水器、活性炭过滤器、紫外线消毒器，确保水质达标。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "防交叉污染",
        "requirement": "不同用途的供水管道应分开设置，避免交叉污染。",
        "source": "《综合医院建筑设计标准》GB 51039-2014",
        "suggestion": "医疗用水、生活用水管道分开铺设，标识清晰；管道采用食品级不锈钢材质，接口密封严密，定期清洗消毒。"
      },
      {
        "dimension": "感控要求与设施",
        "focus": "排水与防回流",
        "requirement": "排水系统应畅通，设置防回流装置，防止污水回流污染。",
        "source": "《综合医院建筑设计标准》GB 51039-2014",
        "suggestion": "配置防回流阀与水封装置，排水管道采用耐腐蚀材质，坡度≥3‰；设置集水坑与潜水泵，确保排水畅通，无积水。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "墙地顶耐腐易洁",
        "requirement": "地面、墙面应防水、防腐、易清洁，适应设备运行环境。",
        "source": "《综合医院建筑设计标准》GB 51039-2014",
        "suggestion": "地面采用防滑耐腐的工业地砖（防滑等级≥R10），墙面满铺防水防腐瓷砖（高度至顶）；顶棚采用轻钢龙骨吊顶，便于管道检修。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "设备固定与防护",
        "requirement": "水处理设备应固定安装，设置必要的防护措施。",
        "source": "《综合医院建设标准》建标 110-2021 专项要求",
        "suggestion": "所有水处理设备固定在混凝土基础上，设置减震垫；设备周边设置防护栏，高度≥0.8m，避免人员碰撞；管道做保温与防结露处理。"
      },
      {
        "dimension": "室内装修与防护",
        "focus": "电气安全防护",
        "requirement": "设备机房应采取必要的电气安全防护措施，防止触电。",
        "source": "《建筑电气工程施工质量验收规范》GB 50303-2015",
        "suggestion": "所有电气设备与插座采用防水防爆型，安装高度≥1.5m；设置接地与漏电保护系统，电线电缆穿管保护，避免受潮短路。"
      },
      {
        "dimension": "安全出口与疏散门",
        "focus": "门洞净宽与无障碍",
        "requirement": "房间门净宽不应小于 1.00m；门应向疏散方向开启。",
        "source": "《综合医院建筑设计标准》GB 51039-2014 第 5.1.4 条、《建筑防火通用规范》GB 55037-2022 第 7.2.1 条",
        "suggestion": "房间门采用双扇门，净宽≥1.2m，向疏散方向开启，无门槛；门体设观察窗，便于观察设备运行情况。"
      },
      {
        "dimension": "安全出口与疏散门",
        "focus": "应急设施配置",
        "requirement": "机房应配备应急照明与通讯设备，应对突发情况。",
        "source": "《建筑防火通用规范》GB 55037-2022 第 10.1.8 条",
        "suggestion": "配置应急照明（照度≥5.0lx），持续供电≥90min；设置应急呼叫按钮与对讲机，确保突发故障时快速联系维修人员。"
      },
      {
        "dimension": "建筑防火",
        "focus": "材料燃烧性能",
        "requirement": "设备机房内部装修材料的燃烧性能等级不应低于 A 级。",
        "source": "《建筑防火通用规范》GB 55037-2022 第 6.1.1 条",
        "suggestion": "顶棚、墙面、地面全部采用 A 级不燃材料，严禁使用易燃、易腐装饰材料；设备与管道保温材料采用阻燃型。"
      },
      {
        "dimension": "建筑防火",
        "focus": "消防设施配置",
        "requirement": "机房应按规范配置消防设施，避免遮挡与腐蚀。",
        "source": "《建筑防火通用规范》GB 55037-2022 第 6.5.1 条",
        "suggestion": "机房内配置耐腐蚀灭火器与消防沙箱，位置醒目且便于取用；烟感探测器、喷淋头做防腐蚀处理，无遮挡，确保火灾时有效响应。"
      }
    ],
    "legacySiteModel": "models/model-real.html?space=clinic",
    "sceneInfo": {
      "area": "6.00 × 4.80 m RO水处理 + 储水/加压 + 取样排水 · 净高 3.00m（≈28.8㎡）",
      "dims": {
        "def": [
          6,
          4.8,
          3
        ],
        "min": [
          5.4,
          4.2,
          2.8
        ],
        "sugg": [
          7.2,
          5.4,
          3.1
        ],
        "minLabel": "模型紧凑",
        "suggLabel": "检修优化"
      },
      "markers": 6,
      "source": "2026.7.6 住院CAD/SKP + AusHFG住院/儿少/标准组件比对",
      "norms": [
        "规范底线：面积≥15㎡",
        "设备墙距≥0.80m",
        "设备间距≥1.00m",
        "机房净高≥2.80m"
      ],
      "compliance": [
        "面积差值：模型示范约28.8㎡，规范底线≥15㎡，高出约13.8㎡。",
        "口径说明：规范底线用于审图合规判断，模型示范尺寸用于表达陪护、设备、活动和维护余量，不应写成规范最低值。"
      ]
    },
    "modelAudit": {
      "source": "核查_59房间_预设与模型_2026-07-13(1).xlsx",
      "sheet": "三维模型",
      "row": 54,
      "priority": "P3",
      "scope": "预设参数、门区、实体碰撞、人物承托、流线、GLB导出",
      "finalSource": "核查_59间模型最终复核结果_2026-07-14(1).xlsx",
      "finalRow": 56,
      "finalStatus": "已完成",
      "finalRequirement": "保留分区关系图与漏水报警状态。",
      "finalVerifiedAt": "2026-07-15",
      "finalResolution": "既有场景按最终复核要求完成运行时校核；语义设计结论仍以规范原文和人工审图为准。",
      "runtimeValidation": {
        "candidate": "20260715e",
        "desktop": "pass",
        "mobile": "pass",
        "checks": [
          "墙体几何与单层标高",
          "家具碰撞与房间边界",
          "门区与流线净宽",
          "人物承托、朝向与工作目标",
          "内隔墙实体性与相机透明规则",
          "画布非空与页面横向溢出"
        ]
      }
    },